Product introduction

This product is suitable for 12V/24V automotive air conditioning system, with refrigeration energy saving, automatic temperature control, high and low speed automatic frequency conversion, under voltage and overpressure automatic warning and protection functions, can automatically protect the battery, controller, compressor and so on when the air conditioning system is working abnormally; The air conditioner panel is used with the compressor controller.

Control panel description

Control board model: FLY-DCP-Q1B

  1. Key description
    Control panel description
    Key function : On key The power on is on, and the power off is off.
    Mode/Setting key Short press: Switch modes, including power, energy saving, heating, and air supply. The corresponding light is on.
    Press and hold to enter the setting state. For details, see the Display Setting description.
    Wind speed + Adjust the wind speed increase, 1-5 corresponding to the display of F-1 to F-5.
    Wind speed – Adjust wind speed reduction.
    Temperature setting temperature increase, 3-30 degrees corresponding to display 03P to 30P. Cooling The setting temperature decreases.

  2. Display the setting instructions
    Switch on the power supply and the display is all bright; Then display the version number; Then display the speed control signal type, such as: 5V-9V/9V- 19V, 5V-9V/9V-19V speed control signal output; Normal state: digital tube displays the detected temperature; When heating and cooling, 03P to 30P is displayed; If the wind speed is + or -, F-1 to F-5 is displayed.

Panel fault status: The fault code is displayed as follows:

Fault code Fault name Fault description
b2 under voltage When the power supply voltage is detected below  the set

under voltage point, enter the under voltage protection, digital Tube display b2 (enter standby mode)
b3| overvoltage| When the power supply voltage is detected to be higher than the set overvoltage     point,     enter     the overvoltage protection, digital Tube display b3 (enter standby state)
EC| Temperature sensor fault| Panel can’t detect temperature, nixie display Er6, check sensor.

Controller upload failure: the controller light flashes several times, and the digital tube displays the corresponding number. If the controller failure light blinks 3 times,
Display: E3, fault definition refer to the fault description of each controller manufacturer *.

Description of controller faults:

Controller failure light| fault code| Controller state| Fault description
---|---|---|---
The fault light blinks twice| E2| Compressor protection overcurrent|

  1. refrigerant charging too much, external heat dissipation is not good (condenser needs to be cleaned or electronic fan does not work);
  2. compressor reverse, switch any two motor lines;

The fault light blinks times 3| E3| Compressor protection locked-rotor|

  1. compressor card cylinder;
  2. the system pressure is too large, check the external machine heat dissipation is good;

The fault light blinks 4times| E4| Controller protection under voltage|

  1. the controller power supply voltage is too low (low battery power);
  2. the power cable is not connected properly (check whether the positive and negative terminals are virtual);

The fault light blinks 5 times| E5| Controller protection short circuit|

  1. compressor motor line short circuit;
  2. the controller is damaged;

The fault light blinks 6 times| E6| Controller protection overpressure| The power supply voltage of the controller is

higher than 16V or 32V

The fault light blinks 7 times| E7| The compressor fails to start continuously| The system pressure is too high, and the external heat dissipation is poor
The fault light blinks 12 times| E12| Compressor phase loss protection| Check whether the compressor motor cable is properly connected
The fault light blinks 13 times| E13| Controller high temperature protection|

  1. the  controller  installation  location ventilation is not good;
  2. long time high load operation, check the heat dissipation of the external machine;

Long press the mode key to enter the setting mode. 2F is displayed for the first time. Then, short press the mode key to display the under voltage value, as shown in the table:

Display code| Set name| Default value| Setting instructions
---|---|---|---
2F| Under voltage value| 10.5V/21V| Set the under voltage protection point, temperature and temperature keys can be adjusted, the range is 9V-10.5V/18V- 23V.
After pressing the “Cool Down” button for 8 consecutive times, the under voltage value can be changed
3F| Overpressure value| 16V/32V| Set the overpressure protection point, the temperature and temperature keys are adjustable, the range is 15V-16V/28V-32V. After pressing the “Cool Down” key for 8 consecutive times, the overpressure value can be changed.
4F| Voltage value| | The current voltage detected is not adjustable.
5F| Ambient temperature| | The detected ambient temperature is not adjustable.
6F| Anti-icing

temperature

| | The detected anti-icing temperature is not adjustable.
7F| KP/LED  terminal function selection| OPE| Display OPE: KP terminal output 12V24V voltage signal when cooling. Display LED: KP/LED socket can be connected to 12V24V1W LED Light bulb, press the remote control light button, can be turned on and off.
Display Hot: mode The heating function is added. During heating, the KP terminal outputs a 12V24V voltage signal. (This terminal has a small current and can only have relay coils). You can change the type after pressing the “Cool Down” key for 8 consecutive times.
8F| Displays the type of the current speed control signal| 5V-9V/ 9-19V| The model is displayed as follows:

2d two file
1.5 1-5V signal output
5.9 5-9V Signal Output
9.19 9-19V signal output
1.10 1-10V signal Output
185 18.0-20.5V signal output
After pressing the “Cool Down” button for 8 consecutive times, the signal type can be changed

9F| Current speed signal output electricity pressure| | Display the current output voltage of the speed control signal, which is convenient to check whether the panel has an output signal and troubleshoot.
10F| Input voltage type| Aut| Display Aut: Input voltage 12V/24V automatic recognition. If 12u is displayed, the input voltage is 12V. Display 24u: The input voltage is 24V. You can change the type after pressing the “Cool Down” key for 8 consecutive times.
15F| Display temperature selection when turning on| JF| The default temperature type displayed during startup can be set:

JF Displays the temperature of the air inlet sensor
cF Indicates the temperature of the anti-icing temperature sensor
0 Displays the configured temperature
You can change the type after pressing the “Cool Down” key for 8 consecutive times.

Control logic

The working mode of the control system is divided into refrigeration, energy saving, sleep and air supply mode, which is freely chosen by the user; The control system collects two sensor temperature values, one is the air outlet temperature of the inner machine, and the other is the air intake temperature.
Cooling mode: The cooling mode is opened by the cooling button and the M key of the remote control.
According to the air inlet temperature and the set temperature difference, the output voltage is automatically adjusted and the compressor speed is adjusted, which is divided into 6 grades.

Gear position| Temperature (e.g. 16 ° C)| 12V/24Vair conditioner parameters
---|---|---
6| >21℃| 9.5/20.5
5| 20~21℃| 9/19.6
4| 19~20℃| 8/19.2
3| 18~19℃| 7/18.7
2| 16~18℃| 6/18.1
1| 14~16℃| 5/17.9
0| <14℃| 0

When the air outlet temperature sensor can be placed in a position that is easy to freeze, when the temperature is detected below 2 degrees, the compressor speed regulation signal output 2 voltage signals (18-20.5 output 18.1V).
Energy saving mode: In energy saving mode, the air conditioner compressor can be adjusted only in 1 or 2 gears. The other logic is the same as the cooling logic.
Air supply mode: Only the internal fan works, and the compressor does not work.
Heating mode: (when the setting item 7F is Hot, there is a heating function, as a heating indicator), less than the set temperature on, greater than (set temperature +2) stop heating. For example, when the ambient temperature exceeds 28 degrees, the heating signal stops output. When the ambient temperature is lower than 26 degrees, the heating signal starts.

Wiring

Speed control signal: Connect the controller speed control cable, output voltage signal (such as: 4V-9V.9V~19V, etc.), the controller adjusts the compressor speed.
Fault signal: Connect the controller fault line and receive the fault signal of the compressor controller.
Temperature sensor: When connecting two temperature probes, plug the inlet air probe into the inlet air display socket, and plug the outlet air probe into the outlet air anti-icing socket. When only one temperature probe is connected, fix the temperature probe in the core position and plug it into the air inlet display socket.

Precautions

  1. Power-on is powered off by default, the first startup is powered on by default in cooling mode, the internal wind speed is high-speed by default, the under voltage is 4V-9V.19V–21.5V, and the overvoltage is powered on by default 16V/32V. If the power is not powered off, the mode and internal wind speed after power-on are powered off by default.
  2. Under voltage and overpressure protection, the internal and external fans and compressors will stop working. After troubleshooting, you need to shut down and restart to restore normal.