ROE DEER CARDIFF-006 Stove Oven and BBQ Fire Place Instruction Manual
- June 15, 2024
- ROE DEER
Table of Contents
ROE DEER CARDIFF-006 Stove Oven and BBQ Fire Place
Product Information
Specifications
- Model : Cardiff A000006A/A000006B
- Brand : Roe Deer
- Version : 1.0 / November 2022
Installation of the Stove
-
Assembly
Our stove offers multiple installation options thanks to the chimney outlets located in its upper and rear compartment. You can determine the chimney outlet that you will install according to the area of use. -
Regulations
All national and local regulations need to be complied with when installing the stove. -
Installation
The stove must be installed by a registered installer or approved by your local building control officer. -
Safety Clearances
The stove must be installed on a solid, level non-combustible hearth and with a gap of at least 600mm from any combustible material such as beams or skirting. When installing a stove, hearths should have a sufficiently flat surface to allow a firm seating surface for the stove body to be positioned during its installation. The appliance should be sited in a properly constructed brick fireplace or recess allowing a gap of 100mm all round, at the rear and both sides.
Operating Instructions
-
Health and Safety
Follow all health and safety guidelines provided in this manual to ensure safe operation of the stove. -
Smoke control areas
(The Clean Air Act 1993 & Smoke Control Areas) Ensure compliance with smoke control regulations in your area when operating the stove. -
Fuel
Use only approved fuel for the stove as specified in the manual. -
Before Lighting
Before lighting the stove, ensure all safety precautions are in place and the stove is properly cleaned and maintained. -
Lighting
Follow the specific lighting instructions provided in the manual to safely ignite the stove. -
De-ashing the Stove
Regularly remove ashes from the stove as instructed in the manual to maintain optimal performance.
Safe Operation Guidance
-
Caution Hot
Be cautious as the outer casing, front, and glass panel of the stove become extremely hot during operation. -
Over Firing
Avoid over firing the stove to prevent damage and ensure safe operation. -
Chimney Fire
Take necessary precautions to prevent chimney fires, such as regular cleaning and maintenance. -
Fumes
Avoid inhaling fumes from the stove by ensuring proper ventilation and following safety guidelines. -
Aerosol Spray
Avoid using aerosol sprays near the stove to prevent potential hazards. -
Fire Guard
Use a fireguard complying with BS 8423:2002 in the presence of young children, the elderly, or infirm. -
Use of Operating Tools
Follow the manufacturer’s instructions when using operating tools for the stove. -
Adverse Weather Conditions
Take necessary precautions during adverse weather conditions to ensure safe operation of the stove.
Maintenance
-
Before Use
Perform necessary pre-use checks and maintenance as outlined in the manual. -
General Cleaning
Clean the stove regularly to remove dust and debris using appropriate cleaning methods. -
Cleaning Glass
Follow the recommended procedures for cleaning the glass panel of the stove to maintain visibility. -
Chimney
Maintain the chimney by regularly cleaning and inspecting it for any blockages or damage. -
Troubleshooting and Fault Finding
Refer to the troubleshooting section of the manual for assistance in identifying and resolving common issues with the stove. -
Further Resources / Information
Contact the retailer in your area or visit the Roe Deer website at www.roe- deer.co.uk for more information on their stove range.
FAQ
Can I burn rubbish in this stove?
No, it is not recommended to burn rubbish in this appliance.
How hot does the outer casing, front, and glass panel get during operation?
The outer casing, front, and glass panel become extremely hot during
operation and can cause serious injury and burns if touched.
Can I install the stove myself?
The stove must be installed by a registered installer or approved by your
local building control officer to ensure proper installation and safety.
ROE DEER – Stove Instructions
Congratulations on the purchase of your new stove!
We have 18 years of experience developing the stoves to ensure the ultimate
performance and years of trouble-free use. Being carefully designed and
engineered, our stoves are manufactured to the highest standarts with the best
materials and the most modern equipment. For more information on our stove
range, please contact the retailer in your area or visit our website www.roe-
deer.co.uk The purpose of this manual is to
familiarise you with your stove, and give guidelines for its installation,
operation and maintenance. Please take time to read this manual and follow the
guidelines on how to operate your new stove.
IMPORTANT
The outer casing, front and glass panel become extremely hot during operati-on
and will result in serious injury and burns if touched. It is therefore recom-
mended that a fireguard, complying with BS 8423:2002 is used in the presence
of young children, the elderly or infirm. Do not attempt to burn rubbish in
this appliance. Please read these instructi-ons carefully before installation
or use.
ROE DEER Stove Instructions
IMPORTANT INFORMATION
- Before installation and/or use of this appliance please read these instructions fully and carefully to ensure that you have fully understood their requirements.
- All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.
- The appliance must be installed by a registered installer, or approved by your local building control officer.
- Only use for domestic heating in accordance with these operating instructions. You must burn only approved fuels.
- This stove will become very hot whilst in operation and due care should be taken. Use only the appropriate tool to operate the hot door handles and ash pan.
- Extra fuel should not be stored on or next to the appliance. Do not place flammable objects on or near the stove.
- The stove must NOT be installed into a chimney that serves any other appliance and is suitable for intermittent burning.
- Do not obstruct inside or outside ventilation required for the safe use of this appliance. There must be a suitable air supply into the room where the stove is installed and care should be taken so it is not possible to block the front or back air inlets to the stove.
- Extractor fans or cooker hoods must not be placed in the same room or space as this can cause appliance to emit fumes into the room.
- Do not make unauthorised changes to the appliance.
- The stove and chimney must be regularly cleaned. It is especially important to check for blockages following a prolonged shutdown period. It is recommended that the stove and chimney flue is regularly maintained by a competent engineer.
- CO Alarms: Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a dwelling, a carbon monoxide alarm conforming to the latest edition of BSEN50292 must be fitted in the same room as the appliance. The existence of an alarm must not be considered a substitute for ensuring regular servicing and maintenance of the appliance and chimney system.
- Under NO circumstances should the stove be operated for extended periods with the main fire door open. This will result in an over firing situation and will lead to severe damage to the stove and flue system.
- Ignoring the warnings could lead to damage/injury to persons and/or property. Any manufacturer instructions must not be taken as overriding statutory require-ments.
- ROE DEER will not be responsible for any consequential or incidental loss or injury however caused.
INSTALLATION OF THE STOVE
PLEASE READ THESE INSCTRUCTIONS CAREFULLY
For your safety it is very important that your stove is correctly installed.
Our stoves cannot accept any responsibility for any fault arising through the
incorrectly practiced installations or use.
Assembly
Our stove offers multiple installation options thanks to the chimney outlets
located in its upper and rear compartment. You can determine the chimney
outlet that you will install according to the area of use.
Regulations
All national and local regulations need to be complied with when installing
the stove.
Installation
The stove must be installed by a registered installer or approved by your
local building control officer.
Safety Clearances
The stove must be installed on a solid, level non-combustible hearth and with
a gap of at least 600mm from any combustible material such as beams or
skirting. When installing a stove, hearths should have a sufficiently flat
surface to allow a firm seating surface for the stove body to be positioned
during its installation. The appliance should be sited in a properly
constructed brick fireplace or recess allowing a gap of 100mm all round, at
the rear and both sides.
IMPORTANT : INSTALLATION MUST COMPLY WITH CURRENT BUILDING REGULA-TIONS ENSURE THAT SUFFICIENT CLEARANCES ARE PROVIDED BETWEEN THE FLUE PIPE AND ANY COMBUSTIBLE MATERIALS IN THE FIREPLACE IN ACCORDAN-CE WITH THE RULES IN FORCE.
Floor
National and local building regulations must be complied with when considering
the floor where the stove is to be installed. The stove should be installed on
a non-combustible surface not less than 12mm thick (conforming to Building
Regulations unless otherwise specified) of suitable load bearing capacity and
heat resistance. The hearth should be level and the appliance fitted at right
angles to it. The hearth has to be able to support the weight of the appliance
and any flue bearing down upon it. The clearance distances to combustible
material beneath, surrounding or upon the hearth and walls adjacent to the
hearth should comply with Building Regulations rules in force.
Combustion Air Supply
All stoves require ventilation to burn safely and correctly. In order for the
stove to perform efficiently and safely there should be an adequate air supply
into the room in which the stove is installed to provide combustion air. Air
starvation will result in poor flue draw and may cause smoke to leak into the
room. There must not be an extractor fan fitted in the same room as the stove
as this can cause the stove to emit fumes into the room. For more detailed
guidelines on required ventilation sizes please refer to Building Regulations
in force.
Access for Cleaning
Consideration must be given to installing extra access in the flue system to
ensure all sections can be cleared and maintained. Only clean the stove when
cold. To clean the glass, either use an oven cleaning fluid or dip a wet cloth
in the wood ash and gently rub clean. The outside can be cleaned with a soft
brush. Do not use abrasive cleaners as this will remove the paint. If the
stove has a period of non‐use leave the primary and secondary air controls in
the open position to allow ventilation through the stove.
OPERATING INSTRUCTIONS
Health and Safety
Please consult health and safety guidelines for advice on handling heavy
and/or large items
Smoke Control Areas (The Clean Air Act 1993 & Smoke Control Areas)
Under the Clean Air Act local authorities may declare the whole or part of the
district of the authority to be a smoke control area. It is an offence to emit
smoke from a chimney of a building, from a furnace or from any fixed boiler if
located in a designa-ted smoke control area. It is also an offence to acquire
an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted” from the controls which generally apply
in the smoke control area). Your local authority is responsible for
implementing the Clean Air Act 1993 including designation and supervision of
smoke control areas and you can contact them for details of Clean Air Act
requirements. Further information on the requirements of the Clean Air Act can
be found here: https://www.gov.uk/smoke-control-area-rules
Fuel
Wood
Any type of wood is suitable (though hardwood is preferable) provided it is
well seasoned and has a moisture content below 20%. Typically this means wood
which has been cut and stored in an open dry shelter for between one and two
years. We recommend that for general burning, wood should be split into logs
of no more than 100mm (4 inches) diameter.
-
DO NOT BURN:
wet or unseasoned wood, painted, impregnated / treated wood, manufactured board products or pallet wood. Doing so will result in the wood burning inefficiently and excess smoke, soot or tar will be produced. This will coat and damage the internal components of the stove and flue and could result in a chimney fire. If, when burning wood, you see signs of sticky tar inside the appliance or chimney, your wood is ‘green’ or too wet and requires further seasoning. -
DO NOT BURN:
bituminous coal, any petroleum based products or any liquid fuels. DO NOT BURN Any form of plastics in this appliance.
Before Lighting
If using for the first time or following a long period out of use check that
the flue is clear and unobstructed. Check that the ash pan is empty and in
position.
WARNING
During the first few times the stove is used, the heat resistant paint will be
curing and may give off small amounts of smoke and odours. This is completely
normal for this type of appliance and we recommend that you light a small fire
for the first few days of use to cure the paint and allow the castings to
relax, not fired vigorously. You may hear your stove produce clicking or
ticking noises whilst it heats up or cools down. This is completely normal and
is produced by the expansion and contraction of the steel components in your
stove when its temperature changes.
BDS Stoves are designed to be operated with the fire door(s) closed at all times, apart from refuelling (when alight) or cleaning (when cold).
Prior to lighting the stove for the first time, please check that Installation and all building work is complete, Building Regulations and any local by-laws have been followed during installation, Carbon Monoxide detector is correctly installed in the same room as the appliance, Suitable provision for combustion and ventilation air, depending upon building regulations have been undertaken. Ensure that you have read and understood these instructions before lighting the fire.
Lighting
Please check whether your dwelling is located in a smoke control area
before installation or use. Please check with your local authority or
https://www.gov.uk/smoke-control-arearules
- Operation with the door open can cause excess smoke. The appliance MUST NOT be operated with the appliance door left open except as directed in the instructions.
- The procedure adopted for ignition is to build a bed in stages and to warm the body of the appliance and the chimney as quickly as practicable.
- Firstly kindling, weighing approximately 1 kg will need to be lit (using a chemical firelighter is recommended) with the air control fully open. When the firelighters or newspaper are burning, leave the door ajar about 1 to 2 cm to achieve a good draw and avoid condensation. Allow the burning kindling to warm up the chimney.
- After 2 to 5 minutes the chimney should be warm enough create a good draw and the door can be closed. Once the kindling has formed a good bed of glowing embers, two small logs can be added. When these are alight and fully blackened, the door can be closed. This, typically, takes approximately a further five minutes. (Do not be tempted to overfill the firebox and risk fuel falling onto the glass or out the fire as the door is opened) Under normal chimney draft conditions expect to refuel the stove every 46 to 60 minutes.
WARNING
- When opening the door, always open gently for the first 2 to 3 cm to allow the pressure to equalise and stop smoke from escaping.
- The stove should not be operated with either door left open for long periods.
- The stove door should never be left open when the stove is in use. Do not leave the fire unattended after refuelling until flames are well‐established on the newly charged logs
De-ashing the Stove
WARNING
Take great care when removing and emptying the ash pan. Ash can remain hot
long after appliance has been in use. Ash can be very hot! Care must be taken
not to burn hands or household objects with falling embers
ALWAYS USE THE GLOVE SUPPLIED.
- Do not allow ash to build up as it may cause damage and adversely effect the perfor-mance of the appliance.
- Warning : Ash can remain hot long after appliance has been in use.
- Before de-ashing the stove, make sure that all the fuel has burned out and the ashes has cool down, then use a brush let the ash fall from bed of the fire into the ash pan underneath. Then take out of the ash pan.
- Do not place hot ash in any container made from plastic or any other combustible material. Empty only into a metal container.
- Even if the ash appears cold, red hot embers maybe concealed and could easily start a fire or cause an injury.
- If the stove still burning when you want to de-ashing the stove, please make sure that you take a Fire-retardant glove and use special tools for cleaning. Brush and vacuum cleaner are not suitable in this case.
SAFE OPERATION GUIDANCE
Caution: HOT
During operation, the stove and all the fittings (door handles and controls)
get very hot.
Over-Firing
Do not over-fill with fuel or run at high temperatures for long periods or
over-firing can occur. Look out for parts of the stove or flue glowing red
hot. lf such a situation occurs adjust the air supply accordingly to reduce
the burning rate.
Chimney Fire
- If the chimney is thoroughly and regularly swept, chimney fires should not occur. However if a chimney fire occurs;
- Shut all air controls immediately.
- Evacuate the building.
- Call the fire brigade.
- Do not re-enter the building until it is confirmed safe
- Do not use the appliance after a chimney fire until it has been inspected by a registe-red installer, confirming the appliance is safe to use.
Fumes
If installed, operated and maintained correctly the stove will not emit fumes
into the room other than occasionally well small amounts when re-fulling and
de-ashing. However persistent fume emission is potentially dangerous and must
not be ignored. If fume emission does persist, the following immediate actions
should be taken;
- Open doors and windows to ventilate the room
- Leave the room
- Let the fire burn out
- Check the stove, flue and chimney for blockages
- Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary, seek expert advice.
Aerosol Sprays
Do not use an aerosol spray on or near the stove when it is alight
Use of Fireguard
When using the stove in situations where children, aged and/or infirm persons
are present a fireguard must be used to prevent accidental contact with the
stove. The fireguard should be manufactured in accordance with BS 8423:2002,
Fireguards for use with solid fuel appliances
Use of Operating Tools
Always use the operating tools provided when handling parts likely to be hot
when the stove is in use.
Adverse Weather Conditions:
In a small number of installations, very occasionally in specific weather
conditions (direction of the wind) the draw of the chimney may be affected
causing a downdrau-ght and fumes to be emitted into the room. If this is the
case the stove should not be used and advice sought from a professional flue
installer who would be able to advise on possible solutions such as an anti-
downdraught cowl.
MAINTENANCE
PLEASE ENSURE THAT THE STOVE IS UNLIT AND COLD BEFORE ANY MAINTENANCE The need for regular maintenance on your stove will ensure, safe and efficient use of your appliance
Before use
It is good practice to keep ash and debris to a minimum. Especially empty the
ash pan section. Remember that if only burning wood it is recommended to keep
a bed of ash about 1 cm thick on the grate.
General Cleaning
- Clean and inspect the appliance regularly, especially in periods of heavy use. Regular cleaning and maintenance will help give many years of safe use.
- Check internal components for damage and for obvious build up of soot, ash or debris above the flue baffle.
Clean the outside of the stove with a soft brush. An annual service by a competent engineer is recommended to keep your stove in the best possible condition.
Cleaning Glass
Before applying a cleaning agent remove any dust and loose soot with a damp
cloth. Clean the stove glass only when cool with a specialist glass cleaner.
Use of any abrasive cleaner will scratch the glass and make subsequent
cleaning more difficult. Before relighting the appliance ensure the glass is
fully dried.
Chimney
- It is important to have the chimney cleaned at least once a year.
- It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period.
- Regular inspection and cleaning of the internal components of the stove can indicate if the chimney requires more frequent cleaning.
- If the stove has been unused for an extended period (during summer) the chimney should be checked by a competent person before use.
Note
All parts that are in direct contact with the fire (grate, buffle,back and
aside air boxes) are considered as normal wear parts. Their life will be
dependant on how vigorously the stove is operated and they must be inspected
and maintained on a regular basis. If they become worn, damaged or not
positioned correctly, non wear parts such as the stove top and sides will be
exposed to excessive heat and may be damaged.
TROUBLE‐SHOOTING AND FAULT FINDING
The Stove does not produce the expected heat into the room:
- The fuel is too wet and not suitable.
- Air inlets to the stove are blocked.
- Inadequate air supply into the room
- Has the flue pipe been sealed to the chimney to prevent heat being drawn up the chimney to waste?
- For the maximum efficiency of heat transference into the room the stove should be sited on the hearth of the fireplace rather than recessed.
The Stove burns too fast
- The chimney has excessive draw (seek installers advice on this point).
- The wood being used may be generally too small.
- The glass is not sealed, gently tighten glass retaining clips. Do not over tighten as this will stress or break the glass.
- Use whole logs rather than split ones.
Soot build up on glass when
- Fuel is too wet
- Fuel pieces are too large and
smouldering
rather than burning - The stove operating temperature is too low
- The stove is being run too slow with not enough air
- Poor chimney draft
Excessive wear on internal parts when
- Stove fired too vigorously
- Too little air passing through the bottom grate
- Use of wood that is too dry (eg: wood from old furniture)
FURTHER RESOURCES INFORMATION
For further information please visit the following resources.
- Competent Person Schemes https://www.gov.uk/guidance/competent-person-scheme-current-schemes-and-howschemes-are-authorised
- Document J Building Regulations (Combustion Appliances) – www.planningportal.gov.uk
- The National Association of Chimney Sweeps (NACS) – www.nacs.org.uk/
- Smoke Control Areas—The Rules – www.gov.uk/smoke-control-area-rules Organisations authorised to certify competence in the installation of domestic solid fuel appliances
(Competent Persons Scheme):
- APHC – Association of Plumbing and Heating Contractors (Certification) Ltd. www.aphc.co.uk
- BESCA – Building Engineering Services Competence Accreditation Ltd. www.besca.org.uk
- HETAS – Heating Equipment Testing and Approval Scheme Ltd. – www.hetas.co.uk
- NAPIT – National Association of Professional Inspectors and Testers Ltd. www.napit.org.uk NICEIC
- NICEIC Group Ltd. – www.niceic.org.uk
All local regulations, including those referring to National & European standards, need to be complied with during the installation, operation and maintenance of the appliance. Before any installation work is undertaken consideration must be given to the Health and Safety at Work Act 1974. Safe working practices should be followed at all times. It is a LEGAL REQUIREMENT that the installation of all new or replacement, wood or solid fuel heating appliance, obtain building control approval from your local authority or the installation work must be carried out through a government approved competent persons scheme.
EN 13240:2006
MODEL CARDIFF| CODE A000006A
A000006B
| Rated Heating Capacity 13 kW
---|---|---
EFFICIENCY 76%| CO RATE0.13%| Dimensions 700x420x750 mm
Place of testing: ITEM Consult Ltd – Testing laboratory Sofia 1220, 8 Istoria Slavianobulgarska Blvd
References
- Support for Plumbing and Heating Contractors | APHC
- Building Engineering Services Competent Assessment (BESCA)
- Smoke control areas: the rules - GOV.UK
- HETAS | Working together for a cleaner safer environment
- Home - The National Association of Chimney Sweeps (NACS)
- Home
- Planning permission: When you need it - GOV.UK
- RoeDeer - Fireplace, Stove, Oven & BBQ
- Smoke control areas: the rules - GOV.UK
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>