MS3 Thermal Imager
Product Information
Specifications:
- Visible light assembly or laser assembly mounting thread
- Eyepiece
- Laser component interface
- Photo key
- Battery cover
- Laser indicator
- Visible light module interface
- Roller
- Power key
- Camera Lens
- Diopter adjustment
- Visible light module
- Tripod threaded hole
- Laser components (optional)
- Memory capacity
- Scene mode
- Pseudo-color mark
- Image Zoom Wire System time
- Battery level
Product Usage Instructions
Main Interface Key Operations:
Power Key:
Press and hold to turn on/off the thermal imager, and the green
indicator of the instrument will be on after the thermal imager is
turned on.
Photo Key:
Short press to take photo/stop recording, long press to start
recording.
Middle Key of the Scroll Wheel:
Short press to toggle the color scale. Press and hold to enter
the user menu.
Scroll Wheel:
Roll left to reduce electronic variable magnification by 0.1.
Roll right to increase electronic variable magnification by
0.1.
Key Combination – Camera Key and Power Key:
Press and hold the Photo key and the Power key at the same time
to manually correct the image.
User Menu Key Operations:
Middle Wheel Key:
Short press OK to enter the next menu.
Photo Key:
Short press to return to the previous menu. Press and hold to
exit the user menu and return to the main interface.
Scroll Wheel:
Roll left to rotate the user menu counterclockwise and turn down
the parameters. Roll right to rotate the user menu clockwise and
adjust the parameters.
Introduction to Menu Functions
Function Menu:
-
Laser Ranging: It can be used only when the laser component is
connected. After opening, aim the instrument at a target, and the
main interface will display the distance of laser ranging. -
Crosspoint: Enter with the middle key of the scroll wheel, set
the cursor type/color of the cross division, and adjust the cursor
position. You can select three cursor styles (style 1, style 2,
style 3), three cursor colors (red, yellow, green), cursor X-axis
movement, cursor Y-axis movement. -
File: Enter by pressing the middle key of the scroll wheel to
view/delete the photos and videos taken by the instrument. -
Probabilistic Ranging: When enabled, automatically displays the
distance of a specific target object on the ruler. -
Hotspot Track: After starting, the cursor will automatically
track the highest temperature point on the display screen on the
main interface. -
PIP: Turn PIP on/off to magnify the center area by 2x.
-
Compass: After opening, the main interface will display the
information of the electronic compass. -
Wi-Fi Mode: In the hotspot mode, the mobile phone can be
connected to the instrument hotspot to operate the instrument. The
WLAN mode instrument can be connected to the router, and the mobile
phone connected to the same router at the same time can operate the
instrument and other functions through the mobile phone client
software. The WiFi name and password can be customized on the
client after connection. Note: Turn on WIFI for a long time to
increase the power consumption of the instrument and shorten the
standby time of the instrument. Please turn off this function when
not in use.
FAQ
Q: How do I turn on/off the thermal imager?
A: Press and hold the Power key to turn on/off the thermal
imager. The green indicator of the instrument will be on after
turning on the thermal imager.
Q: How do I take a photo or start/stop recording?
A: Short press the Photo key to take a photo or stop recording.
Long press the Photo key to start recording.
Q: How do I toggle the color scale?
A: Short press the Middle key of the Scroll Wheel to toggle the
color scale.
Q: How do I enter the user menu?
A: Press and hold the Middle key of the Scroll Wheel to enter
the user menu.
Q: How do I rotate the user menu and adjust parameters?
A: Roll the Scroll Wheel left to rotate the user menu
counterclockwise and turn down the parameters. Roll the Scroll
Wheel right to rotate the user menu clockwise and adjust the
parameters.
Q: How do I view/delete photos and videos taken by the
instrument?
A: Press the Middle key of the Scroll Wheel to enter the File
menu. From there, you can view and delete the photos and videos
taken by the instrument.
Q: How do I enable laser ranging?
A: Laser ranging can only be used when the laser component is
connected. After opening, aim the instrument at a target, and the
main interface will display the distance of laser ranging.
Quick Start Guide
1. Appearance key and composition
Visible light assembly or laser assembly mounting thread
Eyepi ece
Laser component interface
Photo key
Battery cover
Laser indicati
Visible
light
module interface
Rolle r
Power key
Camera Lens
Diopter adjustment
Visible light module
Tripod threaded hole
Laser components (optional)
Memory capacity
Scen e mode
Pseud o-colo r mark
Imag Zoom Wir System time
e
in
eles
mod status s
e
hot
spo
t
Figure 1. Main interface
Batte ry level
2. Key operation on the main interface:
Power key
Press and hold to turn on/off the thermal imager, and the green indicator of
the instrument will be on after the thermal imager is turned on.
Short press after startup to turn on the laser lamp and cross dividing cursor.
Photo key
Short press to take photo/stop recording, long press to start recording
Middle key of the scroll wheel
Short press to toggle the color scale.
Press and hold to enter the user menu
The scroll wheel rolls left
Electronic variable magnification reduces 0.1.
Scroll the wheel to the right
Lectronic variable magnification increases 0.1.
Key combination: camera key and power key
Press and hold the “Photo
correct the image.
” key and the “Power
” key at the same time to manually
3. User menu key operation:
Figure 2. User Menu Interface Figure
Middle wheel key: Short press OK to enter the next menu
Photo key:
Short press to return to the previous menu Press and hold to exit the user
menu and return to the main interface
The scroll wheel rolls left The user menu rotates counterclockwise and turns
down the parameters.
Scroll the wheel to the right
Figure 3. Function Menu Clockwise rotation of user menu and parameter
adjustment
4. Introduction to menu functions
4.1 Function menu * Laser ranging: It can be used only when the laser
component is connected.
After opening, aim the instrument at a target, and the main interface will
display the distance of laser ranging.
Crosspoint: enter with the middle key of the scroll wheel, set the cursor
type/color of the cross division and adjust the cursor position. You can
select three
cursor styles
(style 1, style 2, style 3), three cursor colors
(red, yellow,
green), cursor X-axis movement , cursor Y-axis movement .
File: Enter by pressing the middle key of the scroll wheel to view/delete the
photos and videos taken by the instrument
Probabilistic Ranging: When enabled, automatically displays the distance of a specific target object on the ruler
Hotspot Track: After starting, the cursor will automatically track the highest temperature point on the display screen on the main interface.
PIP: Turn PIP on/off to magnify the center area by 2x.
Compass: After opening, the main interface will display the information of the
electronic compass.
Wi-Fi Mode: In the hotspot mode, the mobile phone can be connected to the
instrument
hotspot to operate the instrument; The WLAN mode instrument can be connected
to the router, and the mobile phone connected to the same router at the same
time can operate the instrument.
WiFi: Turn on/off WiFi Android system can download the mobile client program “IR-TRACKER V” from the official website, install and run the mobile client program, and find the instrument hotspot “MS3.xxxxxxx” (WiFi name is “model _ serial number”) in the mobile WIFI for the first time, and the initial password is “12345678”. After successful connection, open the mobile phone “IR-TRACKER V” software, click the software “Connect” to see the image, and realize the image shooting, video recording, playback, storage and
other functions through the mobile phone client software. The WiFi name and
password can be customized on the client after connection. Note: Turn on WIFI
for a long time to increase the power consumption of the instrument and
shorten the standby time of the instrument. Please turn off this function when
not in use.
4.2 System Menu
Figure 4. System Menu
Auto Sleep: The optional automatic sleep time is 0 min, 5 min, 30 min and 60
min. If there is no operation during this period, the eyepiece will be
automatically
turned off. The low-power standby of the instrument increases the endurance.
Press any key to restore the standby sleep state.
System Information: display information such as instrument model/software
version.
System Upgrade: the version can be upgraded. The version upgrade operation is
as follows: Preparation: Download the version upgrade program file through the
PC (contact the manufacturer’s after-sales technical support for details), and
copy the “bin” upgrade program to the root directory of the local storage
space of the instrument. Instrument upgrade: Click this function in the
instrument and select upgrade. After the instrument is upgraded, press and
hold the “power button” to read the bar and shut down the machine. After the
machine is turned on and restarted, the upgrade is completed.
Format: The memory card can be formatted, and a prompt will appear at the top
after successful formatting. Note: After formatting, all files in the built-in
memory card will be deleted. Please operate with caution.
Recover Default: All parameters will be restored to the default values after
being turned on. It will automatically shut down after the restore is
complete.
Screen Brightness: support 5-gear eyepiece display screen brightness
adjustment.
Compass Calibrate: After entering the compass correction, rotate the
instrument according to the prompt to correct the electronic compass.
Distance Unit: meter/yard. Select the unit for the laser range distance
display. Laser Indication: If the laser indication is turned off, the laser
lamp will not be turned on by pressing the power button for a short time. On
by factory default. 4.3 Infrared Menu
Figure 5. Infrared Menu
Brightness: 0 ~ 100% adjustable, can be adjusted according to the site
environment by the left and right rollers.
Contrast Ratio: 0 ~ 100% adjustable, can be adjusted according to the scene
environment by the left and right wheel.
Red Trigger: -100 ~ 100 adjustable, which can be adjusted according to the
site environment.
Image Mode: Natural/Enhanced/Highlight, can be used for rainy, foggy and other
special scenes. Note: In Enhance/Highlight mode, the contrast and brightness
cannot be adjusted. * 4.4 Fusion Menu (this menu function can only be used
after the visible light module is connected)
Figure 6. Fusion Menu
Fusion Switch: After the fusion switch is turned on, the color code can be
switched to the fusion mode (ocean, forest, desert) and low-light mode through
the middle of the roller in the main interface. When the fusion switch is
turned off, the color scale switching will be switched in the color scale of
the infrared mode.
Fusion Parameters: The fusion image is a visible image superimposed with an
infrared image. Adjust the fusion parameters to set the relative position and
width
of the visible image, so that it overlaps with the infrared image to achieve
the best fusion effect.
Fusion Scene: day/night can be adjusted, and the fusion scene can be adjusted
according to the use time to obtain better image effect.
USB charging/data interface
When charging, open the Type-C interface cover of the instrument and plug in
the USB charging cable (voltage DC5V/2A) for charging.
Open the interface cover of the instrument, connect the USB cable to the
computer, and copy the photos and video data files.
Real-time video output
When using, pull out the cover of the Type-C interface of the instrument and
insert the configured cable to access the display on the monitor or other
long-distance transmission.
Precautions
Because the uncooled infrared telescope uses a very sensitive thermal sensor,
under no circumstances (power on or off) should the lens be directly aimed at
a strong radiation source (such as the sun, laser beam direct or reflection,
etc.), otherwise it will cause permanent damage to the uncooled infrared
telescope!
Use lens cloth and clean water to gently wipe clean, do not use organic
solvents or sharp hard objects to clean the infrared lens, so as not to cause
the lens film to fall off and so on!
After the laser ranging function is turned on, do not irradiate the eyes to
avoid injury!
Please check the power when using the instrument for the first
time. If necessary, charge the instrument for three hours before use. When
charging the USB, please place the instrument at room temperature. Do not open
the enclosure or modify it without authorization, and the maintenance can only
be carried out by the authorized personnel of the company.
FCC Statement This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna. – Increase the separation
between the equipment and receiver. – Connect the equipment into an outlet on
a circuit different from that to which the receiver is connected. – Consult
the dealer or an experienced radio/TV technician for help. To assure continued
compliance, any changes or modifications not expressly approved by the party.
Responsible for compliance could void the user’s authority to operate this
equipment. (Example- use only shielded interface cables when connecting to
computer or peripheral devices). This equipment complies with Part 15 of the
FCC rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that
may cause undesired operation. Any Changes or modifications not expressly
approved by the party responsible
for compliance could void the user’s authority to operate the equipment. The
SAR limit adopted by USA and Canada is 1.6 watts/kilogram (W/kg)
averaged over one gram of tissue. The highest SAR value reported to the
Federal Communications Commission (FCC) the Industry Canada (IC) for this
device type when it is tested for the properly worn on the body is under 1g
1.6W/Kg.
The device complies with the RF specifications when the device is used near
your at a distance of 0 mm from your body. Ensure that the device accessories
such as a device case and a device holster are not composed of metal
components. Keep your device away from your body to meet the requirement
earlier mentioned.
This device was tested for typical body-worn operations. To comply with RF
exposure requirements, a minimum separation distance of 0 mm must be
maintained between the user’s body and the product, including the antenna.
Third-party belt-clips, holsters, and similar accessories used by this device
should not contain any metallic components. Body-worn accessories that do not
meet these requirements may not comply with RF exposure requirements and
should be avoided. Use only the supplied or an approved antenna.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>