Notice
Receiver category according to EN 300220: category 2. This product fulfills the requirements of the norm 2014/53/EU. The Declaration of Conformity is available on request.
Federal Communications Commission
FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. Usually this is followed by the following FCC caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Safety instructions
CAUTION!
- Please also refer to the instruction leaflet for your WERMA signal tower
- The system is not suitable for safety-relevant applications.
- For use with 24 V signal towers only.
- Cannot be used with 641.X00.00 and 840.X00.XX.
- Please note that this version is only approved for use in all EU member countries, the USA and Canada. Further countries upon request.
- The device must not be used in connection with devices that may directly or indirectly serve health- or life-saving purposes or cause hazards by an operation to human beings, animals or asset values.
- The described products have been developed in order to assume safety functions as part of an entire plant or machine. The responsibility taken by the manufacturer of a plant or machine implies safeguarding of correct general function. Moreover, WERMA does not assume any liability for recommendations made or implied by this description. From this description new claims for the guarantee, warranty or liability cannot be derived beyond the general terms and conditions of delivery.
Specifications
Note: To pair the product with WERMA Andon wireless solutions please refer to the WERMA AndonWire-lessBOX manual.
- Dimensions: 70 mm x 65 mm
- Operating voltage: 24 V DC ±10%ES1 PS2, LPS acc IEC/UL/CSA 62368-1
- Current: 60 mA (max. 1200 mA)
- An internal connector for firmware update and configuration: 60 mA (max. 1200 mA)
- A number of signal elements: max. 5
- SRD-frequency: 868,0 … 868,6 MHz
- Transmission range: 500 m (Freifeld) 500 m (unobstructed line of sight) 500 m (sans obstacles)
- ISM-frequency: 921,0 … 922,0 MHz
- Reichweite Transmission range: 500 m (unobstructed line of sight)
Installation
Active power supply: The system requires a permanent operating volt-age (24 VDC ES1 PS2, LPS acc IEC/UL/CSA 62368-1), which should be connected to pin 0 and pin 5 in the terminal element of the signal tower.(see drawing).
Mounting
Position the Transceiver as the first element of your signal tower. Observe the markings on the housing to connect the element correctly.
LED status
LED / Meaning
- red, flashing: Searching the wireless network
- red, blinking: Firmware error
- green, on: Connect to the wireless network
- blue, blinking: Firmware update is being installed