Teleflex CAN-42703-HUQ Incorporated Vascular Access Product Catalog
Product Information
- Specifications
- Product Name: CAN-42703-HUQ
- Product Type: Central Venous Catheter
- Kit Contents: 3L 7 FR X 16CM AGB+
- Antimicrobial: Arrowg+ard Blue Plus* Sharps Safety
- Sales Quantity/Case: 5 Components
- Spring-Wire Guide, Nitinol, Marked: .032 (0.81 mm) dia. x 23-5/8 (60 cm)
- Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- Filter Needle: 18 Ga. TW x 1-1/2 (3.81 cm) with Blunt Fill Tip
- Injection Needle: 25 Ga. x 1-1/2 (3.81 cm)
- Syringe (2x): 5 mL Luer-Lock
- Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
- SecondSiteTM Adjustable Hub: Fastener
- SecondSiteTM Adjustable Hub: Catheter Clamp
- Drape: 29 x 18 (74 cm x 46 cm) with adhesive Towel
- Safety Scalpel: #11
- Gauze Pad (2x): 2 x 2 (5 cm x 5 cm)
- Gauze Pad (10x): 4 x 4 (10 cm x 10 cm)
- Dressing: I.V. Advanced 8.5 cm x 11.5 cm
- Transducer Cover: 14 cm x 147 cm
- Suture: 3-0 Nylon with Straight Needle
- Valve: MicroCLAVETM2 Neutral Displacement Connector
- Documents
- The products in this catalog may not be available in all countries.
- Please contact your local representative. Indications, contraindications, warnings, and instructions for use can be foundin the Product Instructions for Use available under the Documents section on this page, where an IFU is available.
Product Usage Instructions
- Preparation
- Ensure a sterile environment for the procedure.
- Gather all the components from the kit.
- Inspect each component for any damage or defects.
- Prepare the patient’s skin by cleaning the insertion site.
- Insertion Process
- Locate the appropriate insertion site and mark it.
- Anesthetize the insertion site if necessary.
- Using the Spring-Wire Guide, insert it into the marked site with the straight soft tip leading.
- Advance the guide until the J tip emerges.
- Remove the introducer needle from the kit and insert it over the guide wire until it reaches the desired depth.
- Withdraw the guide wire carefully, leaving the introducer needle in place.
- Attach the syringe to the filter needle and fill it with the required solution.
- Insert the filter needle into the introducer needle and inject the solution.
- Remove the filter needle and introducer needle, leaving the catheter in place.
- Secure the catheter using the SecondSiteTM Adjustable Hub and Catheter Clamp.
- Post-Procedure Care
- Cover the insertion site with the provided drape and secure it with adhesive.
- Apply a dressing over the site to protect it.
- Dispose of all used components properly.
- Product Maintenance
- There is no specific maintenance required for this product. Follow standard medical device cleaning and sterilization protocols when necessary.
- FAQ
- Q: Are the components in the kit sterile?
- A: Yes, all components in the kit are sterile and ready for use.
- Q: Can I reuse any of the components?
- A: No, all components are for single-use only. Dispose of them properly after each procedure.
- Q: Where can I find the detailed instructions for use?
- A: The detailed instructions for use can be found in the Product Instructions for Use available under the Documents section on this page.
Representative photo(s): actual product specifications may vary from that shown in the photo.
Home / Central Venous Catheter / CAN-42703-HUQ
- Pressure Injectable Arrowg+ard Blue
- Plus Three-Lumen CVC Kit
- PI CVC KIT: 3L 7 FR X 16CM AGB+
- SKU / Article #: CAN-42703-HUQ
Highlights
- Antimicrobial: Arrowg+ard Blue Plus* Sharps Safety
Considerations
- Chlorhexidine
- Not made with natural rubber latex.
- Precaution: Contains Phthalate: DEHP
- Sales Quantity/Case: 5
Pressure Injectable
Pressure Injectable Arrowg+ard Blue Plus ® Three-Lumen CVC Kit **SKU / Article #: CAN-42703-HUQ**
Quantity| Component Description
1| Arrowg+ard Blue Plus ®1 Three-Lumen Catheter:
7 Fr. (2.5 mm OD) x 16 cm, Pressure Injectable
1| Spring-Wire Guide, Nitinol, Marked: .032″ (0.81 mm) dia. x 23-5/8″
(60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow
® GlideWheel ™ Wire Advancer
1| Catheter: 18 Ga. x 2-1/2″ (6.35 cm)
Radiopaque over 20 Ga. RW Introducer Needl e
1| Filter Needle: 18 Ga. TW x 1-1/2″ (3.81 cm) with
Blunt Fill Tip
1| Injection Needle: 25 Ga. x 1-1/2″ (3.81
cm )
1| Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL
Arrow ® Raulerson Spring-Wire Introductio n Syringe
2| Syringe: 5 mL Luer-Lock
1| Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
1| SecondSite ™ Adjustable Hub: Fastene r
1| SecondSite ™ Adjustable Hub: Catheter Clamp
1| SharpsAway ® II Locking Disposal Cu p
1| SharpsAway ® Disposal Cu p
4| Drape: 29″ x 18″ (74 cm x 46 cm) with adhesiv e
1| Towe l
1| Safety Scalpel: #11
2| Gauze Pad: 2″ x 2″ (5 cm x 5 cm )
10| Gauze Pad: 4″ x 4″ (10 cm x 10 cm )
1| Dressing: I.V. Advanced 8.5 cm x 11.5 cm
1| Transducer Cover: 14 cm x 147 cm
1| Suture: 3-0 Nylon with Straight Needl e
1| Tubing±: 20″ (50 cm) Extension
3| Valve: MicroCLAVE ™2 Neutral Displacement
Connecto r
1| HemoHopper ® Fluid Receptacl e
- Licensed under US Patent No. 7,329,412.
- A trademark of ICU Medical, Inc.
Documents
- The products in this catalog may not be available in all countries. Please contact your local representative.
- Indications, contraindications, warnings and instructions for use can be found in the Product Instructions for Use available under the Documents section on this page, where an IFU is available.
- © 2023 Teleflex Incorporated. All Rights Reserved.
Read User Manual Online (PDF format)