Putogesafe GS535 Small Smoke Detector Alarm User Manual
- June 15, 2024
- Putogesafe
Table of Contents
- GS535 Small Smoke Detector Alarm
- Product description and intended use
- Product specifications
- Where to install a smoke alarm
- Where not to install a smoke alarm
- Activation
- Mounting
- Alarm silence facility
- Low battery mode
- Fault warning mode
- Maintenance
- Recycling and disposal
- Overview LED & acoustic signaling
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SMOKE ALARM
GS535 USER MANUAL
GS535 Small Smoke Detector Alarm
Thank you for purchasing our smoke alarm!
Please read these instructions carefully and store them in a safe place
where you can access them easily.
Product description and intended use
This is a smoke alarm with an optical sensor for installation in residential buildings, apartments and rooms with residential-like use. Smoke alarms are designed to provide an early warning of fire smoke and fires to persons present, so that these persons can react appropriately to the hazardous event. Always consult local regulations for smoke alarms.
Product specifications
Detection method : | Optical |
---|---|
Power supply : | Sealed battery |
Battery lifetime : | 10 years |
Alarm volume : | > 85 dB (A) at 3 meters |
Alarm sensitivity : | 0,094 – 0,149 dB/m |
Monitored area : | 20-40 m² |
Operating temperature : | > 0°C- 40°C |
Operating humidity : | < 93% |
Date of replacement : | See product label |
Individual alarm indicator : | Yes |
Alarm silence facility : | Yes |
Low battery warning : | Yes |
Low battery silence facility : | Yes |
Installation in leisure accommodation vehicles : | Yes |
Mounting location : | Ceiling |
Interconnectable : | No |
Warnings:
- To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installation instructions.
- Batteries should not be exposed to excessive heat such as sunshine, fire or the like.
- Do not paint or cover the smoke alarm.
Where to install a smoke alarm
Smoke alarms must be installed in such a way that they can be reached unhindered by the fire smoke so that fires can be reliably detected during the development phase.
- Install at least in in sleeping areas (especially children’s rooms);
- Install at least in escape rooms;
- In the middle of the ceiling of a room;
- At least 50 cm away from the wall and other objects;
- Maximum installation height of 6 meter.
Where to install a smoke alarm in rooms with special geometries
-
Corridors with a maximum width of 3m: Max. 15m between 2 smoke alarms. Max. 7,5m to the front side of the gallery and smoke alarms at edges/crossings of corridors.
-
Rooms with sloping ceilings:
– If the ceiling inclination is > 20° to the horizontal: Smoke alarms must be installed at least 0.5 m and at most 1m from the ceiling top.
– Partial roof slopes: If the flat ceiling is ≤ 1m wide, consider as ceiling inclination is of > 20°. If the flat ceiling is >1m wide, consider as flat ceiling. -
Rooms with subdivided ceilings:
– Height of the subdivisions is ≤ 0.2 m: Beams without consideration; smoke alarm may be installed on the beams as well as on the ceiling.
– Height of subdivisions is > 0.2 m and area of ceiling panels > 36 m² : Smoke alarm should be installed in each ceiling panel.
– Height of subdivisions > 0.2 m and area of ceiling panels < 36 m² : Individual ceiling without consideration.
Where not to install a smoke alarm
- In an environment with a high risk of draught (e.g. close to air conditioning, fans and ventilation outlets). The movement of air can impair the penetration of fire smoke into the smoke alarm.
- Areas where combustions regularly occurs, such as kitchens.
- Areas with high humidity such as bathrooms, or close to devices such as dish washers or washing machines.
Activation
Before commissioning the smoke alarm, it is important to activate it and test it for correct operation.
- Place the mounting plate on the smoke alarm and secure it by turning it clockwise. When it’s properly tightened, the smoke alarm is activated by the activation switch and generates a loud beep.
- Test the correct activation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not activated properly and should not be used!
Mounting
- Remove the mounting plate from the smoke alarm;
- Place the mounting plate on the desired installation location and mark where the holes should be drilled;
- Drill two holes with a diameter of 5 millimetres;
- Push the plastic plugs into the holes;
- Insert the screws into the mounting plate, and tighten them firmly into the plugs;
- Place the smoke alarm on the mounting bracket and secure it by turning it clockwise;
- When it’s properly tightened, the smoke alarm generates a beep;
- Test the correct operation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not functioning properly and should not be used!
Alarm silence facility
When the smoke alarm has detected smoke and turns into the alarm mode, you can
mute the alarm for a minimum of 5 minutes and a maximum 15 minutes by pressing
the test button. After that, the smoke alarm automatically resets and returns
into the normal operation mode.
If there are still particles of combustion in the air, the smoke alarm will
turn into the alarm mode again.
WARNING: Before using the alarm silence facility, always identify the
cause of the alarm and make sure that the circumstances are safe.
Low battery mode
When the battery is running low, the smoke alarm will indicate this with a
repetitive beep and flash for approximately 30 days.
WARNING: This smoke alarm is equipped with a non-replaceable battery.
When this warning occurs, replace the device as soon as possible! The acoustic
low battery warning signal can be muted for ten hours by pressing the test
button. The smoke alarm is still functioning and able to detect smoke when
it’s in this mode.
Fault warning mode
When the smoke alarm is not functioning properly, it will turn into the fault warning mode. Try cleaning the smoke alarm (see paragraph maintenance) or replace the smoke alarm!
Maintenance
- Test this smoke alarm weekly for correct by operation using the test facility. If the smoke alarm functions correctly, it will generate a loud beep. Due to the loudness of the alarm, make sure that you always stand at arm’s length distance from the unit when you are testing. If the smoke alarm does not generate an acoustic signal, the smoke alarm must be replaced immediately!
- Clean the smoke alarm at least once per month to remove dirt, dust or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke alarm. Do not remove the top cover of the smoke alarm to clean it inside.
- Do not attempt to repair this smoke alarm. If the smoke alarm shows a damage related to its functionality, it must be replaced!
- Trouble shooting: False alarm is often caused by dust or steam.
Recycling and disposal
**** The WEEE symbol means that this product and batteries ps4 must be
disposed separately from other household waste.
When they reach their end of life, take them to a designated waste collection
point in your area to guarantee a safe disposal or recycling. Protect the
environment, human health and natural resources!
Overview LED & acoustic signaling
Operating mode| LED signal (flash)| Acoustic signal (beep)|
Description mode
---|---|---|---
Normal| 1 x per 40 seconds| None| Device is functioning properly
Test| 1 x per second (3 x) /
pause of 1,5 seconds| 1 x per second (3 x) /
pause of 1,5 seconds| Device is being tested
Alarm| 1 x per second (3 x) /
pause of 1,5 seconds| 1 x per second (3 x) /
pause of 1,5 seconds| Device has detected smoke
Alarm silence| 1 x per 8 seconds| None| Smoke alarm is muted
Low battery| 1 x per 40 seconds
(simultaneously with beep)| 1 x per 40 seconds
(simultaneously with flash)| Battery is running low
Low battery silence| 1 x per 40 seconds| None| Low battery warning is muted
Fault warning| 1 x per 40 seconds
(alternating with beep)| 1 x per 40 seconds
(alternating with flash)| Device is not functioning properly