Putogesafe ZA208B Photoelectric Smoke Alarm User Manual

June 1, 2024
Putogesafe

Putogesafe ZA208B Photoelectric Smoke Alarm

Putogesafe-ZA208B-Photoelectric-Smoke-Alarm-product

Product Information

  • Model: Putogesafe Photoelectric Smoke Alarm ZA208B
  • Power Supply: 1PC DC3V built-in lithium battery (Pairdeer CR123A-I / Huiderui CR123A) with 10-year lifetime (included & not replaceable)
  • Operation Current: [specify the value here]
  • Compliance: EN 14604:2005/AC:2008

Product Usage Instructions

  1. Installation: Place the smoke alarm on the ceiling or high on the wall, following the manufacturer’s guidelines for optimal placement.
  2. Testing: Test the smoke alarm regularly by pressing the test button to ensure it is functioning correctly.
  3. Maintenance: Clean the smoke alarm regularly to remove dust and debris that may affect its performance. Do not paint over the smoke alarm.
  4. Battery Replacement: The built-in lithium battery has a 10-year lifetime and is not replaceable. Replace the entire smoke alarm unit after the battery life is depleted.
  5. Alarm Response: In case of a fire emergency, the smoke alarm will emit a loud sound to alert you. Evacuate the premises immediately and call emergency services.

Frequently Asked Questions (FAQ)

  • Q: How often should I test my smoke alarm?
    A: It is recommended to test your smoke alarm at least once a month to ensure it is working correctly.

  • Q: Can I paint over the smoke alarm?
    A: No, painting over the smoke alarm can interfere with its sensors and reduce its effectiveness. Do not paint over the smoke alarm.

  • Q: What should I do if the smoke alarm goes off?
    A: If the smoke alarm sounds, evacuate the building immediately, call emergency services, and do not re-enter until it is declaredsafe.

User Manual
Putogesafe Photoelectric Smoke Alarm ZA208B

Thank you for purchasing our smoke alarm. Please take a few minutes to read the user’s manual thoroughly and familiarize yourself and your family with its opera on. Please keep the user manual for the en re life me of the product. Putogesafe-ZA208B-Photoelectric-Smoke-Alarm- \(1\)

Product Specifications

  • Power supply : 1PC DC3V built-in lithium battery (Pairdeer CR123A-I /
  • Huiderui CR123A ) with 10-year lifetime (included & not replaceable)
  • Operation current :<5uA(standby), <100mA(alarm)
  • Alarm volume : > 85 dB (A) at 3 meters
  • Alarm sensitivity : 0,100 – 0,160 dB/m
  • Operating temperature : 0 °C – 40 °C
  • Operating humidity : < 93 %
  • Individual alarm indicator : Yes
  • Alarm silence facility : Yes | Hush time: approx 10minutes
  • Low battery & fault warning : Yes
  • SOUND PATTERN: BI 0.5s – pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s – pause 1.5s, with the red LED ash, repeat this alarm pattern.
  • COMPLY WITH STANDARD: EN14604:2005/AC:2008

Description
The unit is a photoelectric smoke alarm. With the photoelectric technology, it is more sensible to detect ng slow smolder res which is generally thick and black smoke along with a li le heat and may smolder for hours before
burs ng into ames. The smoke alarm does not contain the radioactive material, which is harmless to the environment.

Important Safety Information

  1. Press the test button to test smoke alarm function. Do not use any other test method. Test smoke alarm weekly to ensure proper operation.
  2. When the smoke alarm is alarming, if you’re sure it isn’t a really alarm, open windows or fan the air around smoke alarm to silence it. Do not remove or disconnect battery. This will take your protection away.
  3. Observe and follow all local and national electrical and building codes for installation.
  4. This smoke alarm is designed to be used inside a single family only. In multifamily buildings, each individual living unit should have its own smoke alarms. Do not install in non-residential buildings. And this smoke alarm is not a substitute for a complete alarm system.
  5. Install a smoke alarm in every room and on every level of the house. Smoke may not reach the smoke alarm for many reasons. For example, if a fire starts in a remote part of the house, on another floor, in a chimney, or on the other side of a closed door, wall or roof, smoke may not reach the smoke alarm in time to alert household members. A smoke alarm will not promptly detect a fire except in the area or room in which it is installed.
  6. Smoke alarm may not alert every household member every time. The alarm horn is loud in order to alert individuals to a potential danger. However, there may be some circumstances where a household member may not hear the alarm (i.e. outdoor or indoor noise, sound sleepers, drug or alcohol usage, bad hearing, etc.). If you suspect that this smoke alarm may not alert a household member, install and maintain specialty smoke alarms. Household member must hear the alarm and quickly respond to it to reduce the risk of damage, injury or death that may result from fire. If a household member is with bad hearing, install special smoke alarms with lights or vibrating devices to alert occupants.
  7. Smoke alarms can only alarm when they detect smoke or combustion particles in the air. They do not sense heat, flame or gas. This smoke alarm is designed to give audible warning of a developing fire. However, many fires are fast – burning, explosive, intentional or caused by carelessness or safety hazards. In this circs, smoke may not remake the unit alarm QUICKLY ENOUGH to ensure safe escape.
  8. Smoke alarms have limitations. This smoke alarm is not foolproof and is not warranted to protect lives or property from fire. Smoke alarms are not a substitute for insurance. Homeowners and renters should insure their lives and property. In addition, it is possible for the smoke alarm to fail at any time. For this reason, you must test the smoke alarm weekly and replace the unit every 10 years.

Indication of Different Status

  • Standby Status: red LED flashes once every 40 seconds indicating the smoke alarm is operating properly.
  • Alarm & Test Status: when the test button is pressed or when the smoke alarm senses particles of combustion and goes into alarm (constant pulsed sound), the red LED will flash once per second. The flashes of LED and pulsating alarm will continue until the air is cleared or the test button is release. Low Battery Voltage Status: An intermittent chirp with red LED flashes once every 40 seconds.
  • Fault Status : 16 seconds after the alarm chirps every 40 seconds, the red light flashes once
  • Silence Mode Status : the red LED will flash once every 8 seconds after pressing the test button in alarm status
  • do not disturb function: 10 hours do not disturb function

Operation

Before commissioning the smoke alarm, it is important to activate it and test it for correct operation.

Activation Press the test button and hold it for approximately 3 seconds until the LED indicator lights up and then release the test button immediately. The smoke alarm will generate a beep to indicate that it’s activated. Note: If no sound is generated, the smoke alarm is not activated properly and should not be used! The unit are not allowed to deactivation!

Test
Right after activation, test is necessary. Test the unit to ensure proper operation by pressing the test button for at least 5 seconds, which will trigger alarm if the electronic circuitry, horn and battery are working properly. If no alarm, the unit has a defective battery or other failure. Refer to “Trouble Shooting” section for a solution.

DO NOT use an open flame to test your alarm, you could damage the alarm or ignite combustible materials and start a fire.

CAUTION: Due to the sound volume (85 decibels) of the alarm, always stand an-arm-length away from the unit when testing. Erratic or low sound volume coming from your alarm may indicate a defective alarm, you can refer to Trouble Shooting section for solution.
NOTE: WEEKLY TEST IS REQUIRED.

Silence Mode (Hush Mode)
The Silence Mode has the capability of temporarily forbidding the alarm circuit to detect smoke for about 10 minutes. This feature is to be used to minimize nuisance alarms only when a known alarm condition, such as smoke from cooking activates the alarm. Press the test button on the top cover for at least 5 seconds (or until the unit sounds) to active Silence Mode, if the smoke is not too dense, the alarm will enter into Silence Mode for approx 10 minutes and the alarm is temporarily in desensitized condition. The smoke alarm will automatically reset after approximately 10 minutes. If particles of combustion still exists after this period, the smoke alarm will alarm again. The Silence Mode can be repeated until the air has been cleared. Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area. Using a fan on a range hood venting to outside (non- recirculation type) will help remove these combustible particles from the kitchen. So the Silence Mode is extremely useful in a kitchen area or other areas prone to nuisance alarms.

CAUTION: Before activating the Silence Mode, identify the source of the smoke and be certain the condition is safe.
DANGER: If the detector pulsed alarms constantly and not because of test, the unit is sensing smoke, THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.

Trouble Shooting

Problem Method of Disposal

Smoke alarm does not sound when testing

NOTE: Press test bu on for at least 5 seconds while testing.

| Please replace a new smoke alarm.
The alarm chirps with red LED ashing once every 40 seconds.| Please replace a new smoke alarm.
16 seconds are the alarm chirps every 40 seconds, the red light ashes once (The alarm goes into fault mode)| Clean smoke alarm referring to the Maintenance and Cleaning sec on. Change a new smoke alarm if the problem still exists.
** Smoke alarm sounds unwanted alarms intermittently or when residents are cooking, taking showers, etc.| Press test button to pause alarm. Clean smoke alarm. Please refer to the Maintenance and Cleaning** sec on.

Move smoke alarm to new location and press test bu on.

---|---
** The alarm sounds different from it is used to. It starts and stops.| Clean smoke alarm. Please refer to the
Maintenance and Cleaning** sec on.

  • If there are s ll failures during warranty, you can return to your retailer.
  • If the unit is out of warranty, please replace a new alarm.

Installation

The smoke alarm should be installed in every room (except the bathroom and kitchen) and every other area of the home, making sure the people in the home will be able to hear and respond to the alarm. For minimum protection you should fit an alarm in the hallway between the living areas and sleeping areas. Place the unit near the living areas as possible and ensure the alarm is audible in bedrooms.

Recommendation on typical single storey dwelling
Install a smoke alarm on the ceiling of each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 30 feet long, install a smoke alarm at each end. If there is a basement: install a smoke alarm on the basement ceiling at the bottom of the stairwell.
Recommendation on typical multi-storey dwelling
Install a smoke alarm on the ceiling of each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 30 feet long, install a smoke alarm at each end. Install a smoke alarm at the top of a first – to- second floor stairwell.

Don’t install smoke alarms in the following places

  1. Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, water heaters). Use special smoke alarm with unwanted alarm to control for this areas.
  2. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 10 feet away from these areas.
  3. Near return air or heating and cooling vents. Install at least 3 feet away from these areas. The air could blow smoke away from the detector and interrupting its alarm.
  4. In rooms where temperatures may fall below 0°C or rise above 40°C, or in humidity higher than 93%. These conditions will reduce battery life or cause fault alarm.
  5. In extremely dusty, dirty, or insect-infested areas, influence particles can interfere with smoke alarm operation.

Where is the best installation place

  • At first you need install an alarm in the bedroom and route way. In the case of several bedrooms, you shall install an alarm in every bedroom.
  • Install it in the stairway and in every floor. Smoke, heat and burning things spread horizontally after rising to the ceiling, so install the alarm on middle of the ceiling of ordinary structure house.
  • If alarm couldn’t be installed in the middle of the ceiling for some reasons, the distance which the alarm from the wall corner should be beyond 50cm. (See Diagram 1). Putogesafe-ZA208B-Photoelectric-Smoke-Alarm- \(2\)
  • If the length of the room or the hall is beyond 30 feet, you need install several alarms in the hall.
  • Smoke alarms in rooms with ceiling slopes higher than 1m in 8m horizontally shall be located on the high side of the room. Install a smoke alarm on sloping, peak or cathedral ceiling between 500mm and 1500mm from the highest point of the ceiling. (See Diagram 2).Putogesafe-ZA208B-Photoelectric-Smoke-Alarm- \(3\)
  • For single story dwellings and multiple storey dwellings, please refer to Diagram 3Putogesafe-ZA208B-Photoelectric-Smoke-Alarm- \(4\) Installation Steps (Please refer to Diagram 4)
  • Remove the fixing plug from the mounting plate (if necessary, use a screw driver for this);
  • Place the bracket on the desired installation place and mark the installation holes on the wall with pencil.
  • Bore two installation holes with diameter 5mm with electric drill.
  • Strike the two plastic plugs into holes with hammer.
  • Insert the screws into bracket and tighten them firmly into plastic plugs
  • Fit the alarm on the bracket and turn the alarm body clockwise, until matching well on the bracket.
    • Insert the fixing plug into the hole between the mounting plate and the smoke alarm to fix your alarm.
    • Press the button for test. If no sound, please replace a new one. If you have any questions on installation, you can contact your retailer.

WARNING: To prevent injury, this unit must be securely attached to the ceiling in accordance with the installation instructions. Installation Sketch Map

Putogesafe-ZA208B-Photoelectric-Smoke-Alarm- \(5\)

Maintenance and Cleaning

In addition to weekly testing, the alarm requires periodic clean to remove dust, dirt and debris. Clean the alarm at least once a month. Vacuum all sides of smoke alarm by a vacuum cleaner with the soft brush. Be sure all the vents are free of debris. Use a damp cloth to clean the alarm’s cover. This alarm has a low battery voltage monitor which will cause the alarm to chirp and at the same time the red LED flashes approx every 40 seconds for a minimum of 30 days when the battery voltage gets low. Replace a new smoke alarm

IMPORTANT: Do not attempt to remove the cover to clean inside. This will affect warranty.

Repair
DO NOT attempt to repair the alarm. It will affect your warranty. If the alarm is not operating properly and is still under warranty, return it to the original place you bought by packing it in a well-padded carton. If the alarm is no longer under warranty, replace it immediately with a comparable alarm.

Practice Fire Safety
If the detector pulsed alarms constantly and you have not pushed the test button, it is warning of a dangerous situation, your immediate response is necessary. Please prepare for such occurrences by developing family escape plans with all household members and practice them regularly.

  1. Expose everyone to the sound of a smoke alarm and explain what the sound means.
  2. Determine two exits of each room and an escape route to the outside from each exit.
  3. Teach all household members to touch the doors before opening them. Instruct them not to open the door and use an alternate exit when the door is hot.
  4. Teach household members to crawl along the floor to stay below dangerous smoke, fumes and gases. 5: Determine a safe meeting place for all members outside the building.

What to do in case of fire

  1. Do not be panic and stay calm.
  2. Leave the building as quickly as possible. Touch doors to feel if they are hot before opening them. Use an alternate exit if necessary. Crawl along the floor and do stop to collect anything.
  3. Meet at a pre-arranged meeting place outside the building.
  4. Call the fire department from outside the building.
  5. Do not go back inside a burning building. Wait for the fire department to arrive.

Note: These guidelines will assist you in the event of a fire, however, to rise the rate of safe escape, please practice fire safety rules and prevent hazardous situations.

Warranty Information

Company warrants to the original consumer. New smoke alarm free from defects in material and workmanship and under correct operation has a period of 3-year warranty from the date of purchase. This warranty does not cover damage resulting from accident, misuse, abuse or lack of reasonable care of the product. In no case shall company be liable for any incidental or consequential damages by breach of this or any other warranty expressed or implied, whatsoever. The bad product can be mailed to the following address with a detail explanation of problem.

Manufacturer: NINGBO EVERSAFE ELECTRONICS CO.,LTD Address: NO. 1 Jiangjia, Dali Village, Shenzhen Town, Ninghai County, Ningbo City, Zhejiang Province 315614 P.R. China
E-mail: [email protected]

MAGNET INSTALLATION METHOD

  1. Remove the 3M film from any of the two sides of the magnetic sheet.
  2. Stick the peeled side to the back cover of the detector.
  3. Remove the other side film from them agnet sheet.
  4. Stick the detector where you need it.

Putogesafe-ZA208B-Photoelectric-Smoke-Alarm- \(6\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Putogesafe User Manuals

Related Manuals