ganiza Z200 Ultrasonic Cool Mist Humidifier User Manual
- June 15, 2024
- GANIZA
Table of Contents
User Manual
Z200
Ultrasonic Cool Mist Humidifier
IMPORTANT SAFETY INSTRUCTIONS
Please read these IMPORTANT SAFETY INSTRUCTIONS before using the humidifier.
Some issues could be avoided by doing so during the use of the product, but it
is not necessary to follow these instructions completely for operating the
humidifier.
BEFORE USING THE HUMIDIFIER
- Check the Power Cord for any signs of damage. If yes, please do not use the humidifier.
- DO NOT place the humidifier in a wet environment.
- Please always keep the humidifier out of the reach of patients, children, and pets.
- Please always place the humidifier on a smooth, flat, lint-free, non-metallic, waterproof and level surface; avoid the direct sunlight
- DO NOT place the humidifier near open flames or heat sources, such as stoves, ovens, radiators or computers.
WHEN USING THE HUMIDIFIER
- DO NOT plug the power cord into an outlet with wet hands.
- DO NOT make the Nozzle facing towards the wall or curtains.
- DO NOT cover the Nozzle with your hand or any other objects when the humidifier is working to avoid damage to the humidifier or injury.
- DO NOT clean the humidifier when it is connected to a power source or when it turned on.
- DO NOT move or tilt the humidifier during operation.
- The recommended ideal humidity is between 40% – 60%. Please adjust the mist as needed.
AFTER USING THE HUMIDIFIER
- Always disconnect the Power Cord by unplugging it when the humidifier is not in use.
- The humidifier requires regular cleaning. Please refer to the instructions mentioned in the section of Maintenance and Care.
- DO NOT clean the humidifier immediately after turning it off. Allow the humidifier to cool down completely before cleaning.
- DO NOT attempt to repair, or adjust any electrical/mechanical functions of the humidifier by yourself.Ganiza will accept no liability or responsibility for fires, explosions or electrical shocks caused by improper operation, dismantling the humidifier or by not adhering to the above safety instructions.
WHAT’S INCLUDED
SPECIFICATIONS
Model | Ganiza Z200 |
---|---|
Operating Voltage | AC 100-240V; 50/60Hz |
Rated Power | 30w |
Water Tank Capacity | 40L/106Gal |
Net Weight | 138kg / 47607 |
Dimensions | 258 x164x338mm /10.2×6.5×13.3in |
Atomization Amount | 60-300ml/h |
PRODUCT OVERVIEW
OPERATION GUIDE
ADD WATER
- Remove the Nozzle first. Separate the Water Tank from the Base, turn the Water Tank upside down 1, loosen the Tank Cap 2, 3, then fill the tank with clean and cool water(@).
- Tighten the Tank Cap(5), then turn the Water Tank upright and put it back on the Base(6)
Tips:
- Make sure that the Water Tank and the Base are well fitted so that the water can go to the Water Reservoir.
- Please make sure that the sealing ring is well installed on the Tank Cap.
Important:
- If the tap water is too hard, we recommend using the filtered or distilled water to avoid white dust. DO NOT use hot water.
- DO NOT add any essential oils or medicinal tablets into the Water Tank.
- DO NOT add water into the Base or through the Nozzle.
- DO NOT move the humidifier while the Water Tank is full of water to avoid leakage or Base overfilling
POWER ON/OFF AND MIST CONTROL
Step:
Plug the Power Cord into a socket
Step 2:
Rotate the Control Knob clockwise to the ON position. The white LED indicator
will light up indicating the humidifier has been turned on to a minimum mist
level.
Step 3:
- Rotate the Control Knob clockwise to increase the intensity of mist.
- Rotate the Control Knob clockwise to reduce the intensity of mist.
Step 4:
Rotate the Control Knob clockwise to the OFF position to turn off the
humidifier. The LED indicator will turn off.
LOW WATER PROTECTION
When there is not enough water inside the water reservoir, the humidifier will
stop misting and the LED indicator will become red.
It is designed for safety to prevent the humidifier from possibly overheating
and damaging the atomizer.
MAINTENANCE AND CARE
Important:
- DO NOT submerge the Base in the water.
- DO NOT wash any parts of this humidifier in the dishwasher; otherwise, it will damage the humidifier.
- Make sure the water does not enter the Base through the Air Outlet, Air Inlet or Multi-function Control.
DAILY MAINTENANCE
Step 1: Turn off the humidifier and unplug the Power Cord from the socket
Step 2: Drain water from the Water Tank, Water Reservoir, and Base.
WEEKLY MAINTENANCE
- To properly clean your humidifier, we recommend that you remove scale and disinfect the humidifier separately.
- DO NOT mix vinegar and bleach solution. To avoid damage to the humidifier, do not use more than 1teaspoon of bleach per gallon of water.
- Please make sure the white sealing ring on the Tank Cap is installed correctly after cleaning to avoid water leakage.
Scale Removal Instructions
Step:
Turn off and unplug the humidifier.
Step 2:
-
Separate the Water Tank from the Base, then remove the Tank Cap.
Make sure that the white sealing ring does not come off. -
Drain water from the Water Tank and Base, then remove all accessories and set aside.
Step 3:
- Fill the Water Tank halfway. Add in 1teaspoon of undiluted distilled white vinegar.
- Attach the Tank Cap and shake for 15 seconds,
Step 4:
Place the Water Tank back to the Base. The vinegar solution will enter the
Water Reservoir to loosen mineral scale on the Atomizer, Water Floater and the
bottom of the Water Tank. Leave it for 15-20minutes.
Steps:
- Uncap the Tank Cap and drain the solution.
- Wipe the Atomizer and floater with a soft cloth to removeloose mineral deposits.
Step 6:
Wosh both the Water Reservoir and Water Tank until the smell of vinegar (for
scale removal) or bleach solution ( for disinfection, see below) is gone.
Disinfection Instructions
Step 1:
Follow steps 1to 2 of the scale removal instructions in the previous
section. Step2:
- Fill the Water Tank halfway. Add 7% teaspoon of bleach into the Water Tank
- Attach the Tank Cap and shake for 15 seconds.
Step 3:
Place the Water Tank back to the Base. The bleach solution will enter and
disinfect the Water Reservoir and the other components. Leave it for 15-20
minutes. Step 4:
Follow steps 4 to 6 of the previous section for scale removal to complete the
disinfection of the humidifier.
DUSTPROOF SPONGE CLEANING
Clean the Dustproof Sponge (located on the back of the Base) with water or
detergent monthly, then put it back in place. END-OF-SEASON CARE AND STORAGE
- Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season. Remove all accessories from the humidifier, and allow the humidifier and accessories to dry completely before storing it.
- DO NOT store water in the Base, Water Reservoir or Water Tank
- Pack the humidifier safely and store it in a cool, dry place.
TROUBLESHOOTING GUIDE
- If you need any further assistance, please feel free to contact us at service@ganiza.com.
- Failure to keep the humidifier clean and free of mineral deposits may affect the operation of it
Q1. There is no or little mist produced.
Possible Cause | Solution |
---|---|
Not enough water inside the tank | Refill and place the Water Tank back in |
place.
Mist level is set too low.| Adjust the humidifier to the maximum mist.
Mineral buildup on the Atomizer.| Check if any air comes out from the Nozzle
If not, clean water scale on the Atomizer as instructed.
The Base might be overfilled.| Remove the tank, empty the Base, then place the
filled tank on the empty Base
Q2. Tank leakage.
Possible Cause | Solution |
---|---|
Tank may be damaged | Check for possible cracks in the tank. If yes,please |
replace it.
Tank Cap is not tightened securely.| Tighten the Tank Cap.
1 Spring was stuck| Make sure the 2 Spring is fixed correctly to the bottom of
the tank so that water can pass through to the Base,
2 Sealing Ring was not installed on Tank Cap.| Make sure the MSealing Ring has
been installed on the Tank Cap. Please contact us if itis lost
Q3. The mist makes the surrounding around humidifier or on windows; tables or floors damp. Condensation occurs/walls.
Possible Cause | Solution |
---|---|
Mist level is set too high for the room size. | 1. Check if the room is too |
humid and adjust the humidifier to a lower mist. 40%-60%
works best
2. Open door and windows, or change to a larger room,
Air Inlet wos blocked.| Make sure the humidifier is placed =12 inches away
from the wall. Make sure the Nozzle is nat facing the wall or window,
Low indoor temperature leads to liquefaction.| Adjust the room temperature to
25°C / 77°F.
Q4. The humidification is too poor.
Possible Cause | Solution |
---|---|
Mist level is set too low for the room size. | 1. Adjust the humidifier to the |
maximum mist.
2. Close door or windows to reduce air ventilation, or change to a smaller
room.
Air Inlet was blocked.| Make sure the humidifier is placed 212 inches away
from the wall. Make sure the Nozzle is not facing the wall or window.
Low indoor temperature leads to liquefaction.| Adjust the room temperature to
25°C / 77°F.
Q5. White dust appears o the black coating on the Base flakes off.
Possible Cause | Solution |
---|---|
The tap water may contain too much minerals. | Please replace it with filtered |
or distilled water.
Q6. Strange odor.
Possible Cause | Solution |
---|---|
The humifier needs to be cleaned. | 1. Please make sure to clean the |
huridifier according to the instructions,
2. Leave the empty Water Tank in a cool place for 12 hours without covering
Tank Cap
Q7. Strange water noise.
Possible Cause | Solution |
---|---|
Water is going down to the Water Reservoir. | This is normal while it is |
working
Q8. Humidifier is getting too hot.
Possible Cause | Solution |
---|---|
The humidifier works for too long | Please power it off and put it in a well- |
ventilated place for 10 minutes.
CAUTION
Users should only operate the humidifier once they have understood all the
following important safety instructions.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experi ence and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Unplug the appliance during filling and cleaning.
- Please confirm the composition and quantity of solution to be used during mainte nance. If salt is included, it is recommended not to use excessive amounts of solution. The appliance is not to be operated from ad.c supply – If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
CUSTOMER SUPPORT
service@ganiza.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>