LANTRONIX MGE-PSW-PSE-01 Gigabit Ethernet Poe Media Converter Instruction Manual
- June 15, 2024
- LANTRONIX
Table of Contents
- Intellectual Property
- Warranty
- Contacts
- Disclaimer
- Revision History
- Product Description
- Ordering Information
- Features
- Feature Descriptions
- Auto Power Reset
- Specifications and Standards
- Installation
- Cautions and Warnings
- Installation Overview
- Mounting Options
- Operation’
- LED Descriptions
- Compliance Information
- Product Views
- Power Supply
- Features
- Specifications
- Input Specifications
- Output Specifications
- Protection
- Environmental Specifications
- General Specifications
- Physical Specifications
- Power Supply
- Power Supply Specifications
- Power Supply Dimensions
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LANTRONIX MGE-PSW-PSE-01 Gigabit Ethernet Poe Media Converter Instruction
Manual
Intellectual Property
© 2022 Lantronix, Inc. All rights reserved. No part of the contents of this
publication may be transmitted or
reproduced in any form or by any means without the written permission of
Lantronix. Lantronix is a registered trademark of Lantronix, Inc. in the
United States and other countries. All other trademarks and trade names are
the property of their respective holders. Patented: patents.lantronix.com;
additional patents pending.
Warranty
For details on the Lantronix warranty policy, please go to our web site at http://www.lantronix.com/support/warranty.
Contacts
Lantronix Corporate Headquarters
7535 Irvine Center Drive
Suite: 100
Irvine, CA 92618, USA
Toll Free : 800-526-8766
Phone: 949-453-3990
Fax: 949-453-3995
Technical Support
Phone: +1.952.358.3601 or 1.800.260.1312
Email: techsupport@transition.com
Sales Offices
For a current list of our domestic and international sales offices, go to the
Lantronix web site at
www.lantronix.com/about/contact.
Disclaimer
All information contained herein is provided “AS IS.” Lantronix undertakes no obligation to update the information in this publication. Lantronix does not make, and specifically disclaims, all warranties of any kind (express, implied or otherwise) regarding title, non-infringement, fitness, quality, accuracy, completeness, usefulness, suitability or performance of the information provided herein. Lantronix shall have no liability whatsoever to any user for any damages, losses and causes of action (whether in contract or in tort or otherwise) in connection with the user’s access or usage of any of the information or content contained herein. The information and specifications contained in this document are subject to change without notice.
Revision History
Date | Rev | Notes |
---|---|---|
5/6/21 | A | Initial release at FW 24228A_RC1, PCB 11639 Rev 1A, 11638 Rev1A and |
power supply 25173.
5/19/21| B| Update power supply connector information and remove powered
chassis references.
2/24/22| C| Initial Lantronix re-brand. Update power supply information.
Product Description
The Lantronix M/GE-PSW-PSE-01 Gigabit Ethernet Stand-alone Mini Media Converter provides cost effective media conversion between 10/100/1000Base-T ports and 100/1000Base-SX/LX ports. With its fixed configuration, deployments are just plug-and-play, and its small size makes it ideal for locations where space is limited. Operating at Layer 2, the data link layer, this converter not only converts copper to fiber, but it also provides rate conversion allowing legacy 10/100 copper devices to connect to 1000Base-SX/LX fiber.
In addition to providing copper to fiber conversion, this converter is also classified as Power Sourcing Equipment (PSE), meaning it combines data received over the fiber optic link with 56VDC input power to provide power and data to a Powered Device (PD) over the twisted Pair cable, while complying with the IEEE 802.3af and IEEE 802.3at PoE+ standards. This allows the user to take advantage of the benefits of fiber cabling, along with the benefits of Power-over-Ethernet (PoE) technology.
Supporting PoE allows this converter to send data and power to devices like
VoIP Phones, Security Cameras, and Wireless Access Points, especially if they
must be located in remote areas of your network that can only be
reached with fiber optic cabling.
Ordering Information
SKU | Description |
---|---|
M/GE-PSW-PSE-01 | (1) 10/100/1000Base-T PoE+ RJ-45 port [100 m/ 328 ft.] |
to (1) 100/1000Base-X SFP slot (empty). Includes Power Supply. Note :
Cannot be used with M-MCR-01 or E-MCR-05 Racks due to power limitations.
Optional Accessories (sold separately)
SFP/SFP+ Modules| See our SFP Products page (sold separately)
WMBM| Wall Mount Bracket for Mini Converters (sold separately)
DRBM| DIN Rail Mount Bracket; fits all “Mini” Media Converters
RMBM| Rack Mount Bracket for Mini Converters, use with RMS19-SA4-02 (sold
separately)
Power Supply included: to order the corresponding country specific power supply, add the extension below to the end of the SKU. M/GE-PSW-PSE-01-NA = North America, -LA = Latin America, -EU = Europe, -UK = United Kingdom, -SA = South Africa, -JP = Japan, -OZ = Australia, and -BR = Brazil.
Features
- Wall mount, DIN Rail, or tabletop installation
- External AC/DC power supply included with country specific power cord
- 2-port 10/100/1000 copper to fiber media conversion with IEEE 802.3at PoE+ on the copper port
- Supports full 30 Watts of power to the twisted pair port
- SFP slots can support any 100Base-FX or 1000Base-X fiber SFP module
- Supports Auto-Negotiation and Auto-MDI/MDIX
- Supports Active Link Pass Through (ALPT)
- Supports Auto Power Reset
- Jumbo frame support
- 8K MAC address table
- LEDs indicators for power status, Link/Activity per port, PoE status/classification, APR state
- Plug-and-Play fixed configuration, no DIP switches
- Over-current protection, Under-current protection, and Fault protection input
Feature Descriptions
Active Link Pass Through (ALPT)
The ALPT (Active Link Pass Through) function is a feature that disables
Link Pass Through after the device has first powered up. ALPT allows the user
to see the link status with only one media connected (either the Fiber or the
Copper link). Once both media ports have established link or are active at the
same time, the converter will automatically enable its Link Pass Though
feature. The LPT feature now enabled will monitor the link status of each
port. If either port’s link status changes to down, the converter will disable
the other port to indicate to the end device that the link partner is no
longer communicating. The ALPT feature is permanently enabled. A power cycle
to the device will disable the LPT feature again until both links are
established.
Auto Power Reset
The Automatic Power Reset (APR) feature is enabled after the device has been powered for one minute and the ALPT feature is enabled. When both of these conditions are met, whenever the fiber link goes down due to the fiber partner link status or the ALPT forwarded copper link partner status, the converter will detect that the fiber link is down, disable the POE power for 5 seconds, and then allow the PSE to re-start power negotiation with a PD (powered device).
After an APR event the converter will lock out the power reset feature for five minutes to allow time for the PD device to fully boot and re-establish link. When the five minute timeout is complete and the Fiber link has been reestablished, the APR functions will begin monitoring for the next fiber link down event.
Circled in red above is the location of LED 4 that can be seen inside the metal. LED 4 will turn solid green when the APR function is enabled and is monitoring the fiber link.
Auto-Negotiation
The Auto-Negotiation feature is permanently enabled.
Auto-MDI/MDIX
The Auto-MDI/MDIX feature is permanently enabled.
Specifications and Standards
Spec | Description |
---|---|
Standards | IEEE 802.3-2012, IEEE 802.3af/at PSE-PoE, IEEE 802.3ab, IEEE |
802.3z, IEEE 802.3x, IEEE 802.3az
Switch Features| Max Packet Size 10,000 bytes Max MAC Addresses 8k1Mbit
shared buffer memory
Dimensions| Width: 1.8” [46 mm] x Height: 0.85″ [22 mm] x Depth: 3.3”
[85 mm]
Power Consumption| 34W with full IEEE 802.3at 30 Watt load
Power Supply Connector| Standard 2.5 mm barrel
Power-over-Ethernet| Max PoE Budget: 30 Watts
Environment| Operating Temp: 0°C to +40°C (with included power supply)
Storage Temp: -40°C to +85°COperating Humidity: 5% to 95% (non-
condensing)Altitude: 0 – 10,000 ft.
Weight| 2 lbs. (0.9 kg) (complete package)4.17 oz. (118 g) (converter
alone)
MTBF| M/GE-PSW-PSE-01 only: 2,941,024 hours (Telcordia SR-332)
Certifications| EN55032-2012 Class A, IEC 61850-3:2002,EN55024-2010, CE
Mark, Power Supply is UL listed
Warranty| Lifetime
Data speed| TP: 10/100/1000MbpsSFP: 100FX/1000X. SGMII not supported on
this product
DIP Switches and Jumpers| None; all features are permanently enabled
Certifications| EN55032-2012 Class A, IEC 61850-3:2002,EN55024-2010, CE
Mark, Power Supply is UL listed
The M/GE-PSW-PSE-01 is an 802.3at device; it will only provide power on one pair. Highlighted in yellow below is the M/GE-PSW-PSE-01 pinout.
PSE Pinout Alternatives
Conductor| Alternative A (MDI-X)| Alternative A (MDI)|
Alternative B (All)
---|---|---|---
1| Negative VPSE| Positive VPSE|
2| Negative VPSE| Positive VPSE|
3| Positive VPSE| Negative VPSE|
4| | | Positive VPSE
5| | | Positive VPSE
6| Positive VPSE| Negative VPSE|
7| | | Negative VPSE
8| | | Negative VPSE
Note: All PD devices must accept power on either pair (Alternative A or Alternative B).
Installation
Warning : Do not attempt to open the enclosure or service the power supply. Opening the enclosure may causeserious injury or death. There are no user replaceable or serviceable part in this device.
Cautions and Warnings
Cautions indicate that there is the possibility of poor equipment performance or potential damage to the equipment. Warnings indicate that there is the possibility of injury to person. Cautions and Warnings appear here and may appear throughout this manual where appropriate. Failure to read and understand the information identified by this symbol could result in poor equipment performance, damage to the equipment, or injury to persons.
Caution : While installing or servicing the power module, wear a grounding device and observe all electrostatic discharge precautions. Failure to observe this caution could result in damage to, or failure of the power module.
Warning : Do not connect the power module to an external power source before installing it into the chassis. Failure to observe this warning could result in an electrical shock, even death.
WARNING: Equipment grounding is vital to ensure safe operation. The installer must ensure that the power module is properly grounded during and after installation. Failure to observe this warning could result in an electric shock, even death.
WARNING: A readily accessible, suitable National Electrical Code (NEC) or local electrical code approved disconnect device and branch-circuit protector must be part of the building’s installed wiring to accommodate permanently connected equipment. Failure to observe this warning could result in an electric shock, even death.
WARNING : Turn any external power source OFF and ensure that the power module is disconnected from the external power source before performing any maintenance. Failure to observe this warning could result in an electrical shock, even death.
WARNING : Ensure that the disconnect device for the external power source is OPEN (turned OFF) before disconnecting or connecting the power leads to the power module. Failure to observe this warning could result in an electric shock, even death. See Electrical Safety Warnings for Electrical Safety Warnings translated into multiple languages.
Installation Overview
- Mount the Media Converter in its final location; see ‘Mounting Options’ below.
- Perform Grounding procedure.
- Insert SFP.
- Install and connect the fiber cable.
- Install and connect the copper cable.
- Power up the media converter.
- Check LED status.
Mounting Options
W MBM: 3.3” Wall Mount Bracket for Mini Media Converters.}
DRBM : 3.3” DIN Rail Mount Bracket for Mini Media Converters.
RMBM: Rack mount bracket for Mini Media Converters, used with
RMS19-SAA-02.
Operation’
Status LEDs
When the module has been installed and configured, verify the converter is
operational by viewing the LEDs.
-
The Power LED indicates the module is receiving power.
-
The Fiber status LED indicates the fiber optic connection has been established.
-
The RJ-45 TP status LEDs indicate the speed of the RJ-45 port connection.
-
The PoE status LED indicates the module has established a successful detection of a PD and is supplying
Power over E theme.
-
LED 4 can be seen inside the metal. LED 4 will turn solid green when the APR function is enabled and is monitoring the fiber link. LED 4 is circled in red below. See the Auto Power Reset description above.
LED Descriptions
LED | Description |
---|---|
Two-up Bi-Color LEDs | Top LED – TP Status: |
- Green = Gigabit
- Yellow = 100 or 10 speeds.
- Off = no link
- There is no indication for duplex
Bottom LED – Fiber Status:
- 100FX TP Link/Activity: Yellow On = Link. Yellow Blinking = Activity·
- 1000X TP Link/Activity: Green On = Link. Green Blinking = Activity
Power LED| Green ON = power applied to board
PoE Status LED| When powering an 802.3af PD: Yellow = On When powering an
802.3af PD over-load or short: Yellow Blinking at 1Hz Vin under-voltage or IC
over-temp: Yellow Blinking at 4HzWhen powering an 802.3at PD: Green = On When
powering an 802.3aftPD over-load or short: Green Blinking at 1Hz
APR Status LED inside enclosure|
- Solid green: APR is armed and ready to reset power to the PSE port when the fiber link status goes to the down state.
- Blinking green: APR is not ready; waiting for timeout or fiber link to be re- established.
Note: The TP-L/A Act 1000 and SFP-L/A Act 1000 flash green because this
converter has MAC Learning disabled,
so whenever a packet is received on one port, that packet will always be
repeated on the other port. This
functionality causes the Activity LED for BOTH ports to ALWAYS flash in
unison, even for unidirectional traffic.
Compliance Information
Product Views
Power Supply
The M/GE-PSW-PSE-01 uses Power Supply 25173 for all country bundles except -JP. (See 25188 bundle specs for the -JP bundle.)
25173 Commercial Power Supply
The 25173 AC/DC desktop power supply offers 40 watts of output power with
an IEC-320-C8 AC inlet.
The 25173 has a rated input voltage of 100-240VAC, and is designed to meet Energy Star Ver. 2.0, DoE Level VI, and ErP STEP2. It has over-voltage and over-current protection and UL, cUL, CB, CE, FCC, RCM, BSMI, IRAM, and CCC safety approvals.
Features
- Rated Input Voltage 100-240 VAC
- 40 Watts Max
- Single Output
- Designed to meet Energy Star Ver. 2.0, DoE Level VI, and ErP STEP2
- IEC 320-C8 AC inlet
- ROHS Compliant
- Over-voltage and over-current protection
- UL, cUL, CB, CE, FCC, RCM, BSMI, IRAM, and CCC Safety Approvals
Specifications
All specifications are based on 25⁰C, Nominal input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technical advances.
Dimensions: 4.45 in. x 1.93 in. x 1.38 in. (113 mm x 49 mm x 35 mm)
Input Specifications
Specification | Min. | Typ. | Max. | Unit of Measure |
---|---|---|---|---|
Rated Input Voltage | 100 | 240 | VAC | |
Normal Line Input | 115VAC/60Hz, 220VAC/50Hz | |||
Input Frequency | 47 | 63 | Hz | |
Input Current (full load) | 2.0 | A | ||
Input Fuse (Input Hot line side must be fused) | Rating (3.15A/250V) | |||
Inrush Current @ 110VAC, cold start, max load | < or = 80 | A | ||
Inrush Current @ 220VAC, cold start, max load | < or = 160 | A |
Output Specifications
Specification | Min. | Typ. | Max. | Unit of Measure |
---|---|---|---|---|
Output Voltage | 56 | VDC | ||
Regulation | 53.2 | 58.8 | VDC | |
Line Regulation | ± 1 | % | ||
Dynamic Load Regulation | ± 5 | % | ||
Voltage Tolerance | ± 5 | % | ||
Output Power | 40 | W | ||
Output Current | 0 | 0.71 | A | |
Ripple and Noise | 720 | mV | ||
No Load Power Consumption | 0.1 | W | ||
Hold-Up Time | ≥ 8.3 | mSec. | ||
Rise Time | ≤ 50 | mSec. | ||
Turn-On Time | 3 | Seconds |
Protection
Specification | Min. | Typ. | Max. | Unit of Measure |
---|---|---|---|---|
Over Current Protection | 110 | 200 | % | |
Over Voltage Protection | 175 | % |
Environmental Specifications
Specification | Min. | Typ. | Max. | Unit of Measure |
---|---|---|---|---|
Operating Temperature | 0 | 40 | ⁰C | |
Storage Temperature | -20 | 85 | ⁰C | |
Operating Humidity | 10 | 90 | % | |
Storage Humidity | 5 | 90 | % | |
Temperature Rise (Optional) | 45 | ⁰C | ||
Altitude (Operation and Non-operation) | Sea Level | 5000 | M | |
Stability | 2 | % | ||
MTBF (MIL-HDBK-217F, 25⁰C) | 100,000 | Hours |
General Specifications
Specification | Min. | Typ. | Max. | Unit of Measure |
---|---|---|---|---|
Efficiency | ≥ 87.59 | % | ||
IR | ≥ 50 | MΩ | ||
Leakage Current | ≥ 500 | uA |
Voltage Isolation: DC ground may be separated from AC neutral and AC
line.
Insulation Test : Between primary and secondary circuit: 500VDC, 2 Sec.
Configuration: Line, Neutral: 2-Wire, AC Input.
Hi-Pot Test: Between primary and secondary circuit: 3000VAC/4242VDC, 3mA
2 Sec.
Drop Out: Output voltage should remain in specified range, through the
absence of line input during ½ cycle, at full load and normal AC line input.
Physical Specifications
Weight: 10.58 Oz (300 Gr.)
Dimensions: 4.45 in x 1.93 In. x 1.38 In. (113mm x 49mm x 35mm)
Enclosure Material: 94V-0 Minimum
Output Cable: UL2468#20
Safety Characteristics
Safety Approvals| UL, CUL, CB, CE, FCC, RCM, BSMI, IRAM, CCC|
---|---|---
EMI| CISPR 32, EN 55032FCCP Part 15| Class B Class B
ESD| IEC 61-000-4-2| Contact: ±4kV Air: ±8kV
RS| IEC 61-000-4-3| Frequency: 80~1000MHzField Strength: 3V/M, 80%
AM (1KHz)
EFT| IEC 61-000-4-4| 1.0KV on Input Power Ports
Surge| IEC 61-000-4-5| Line to Line: ±1kV (peak)
**** Efficiency| | Energy Star Ver. 2.0, DoE Level VI, ErP STEP2
Note: Specifications subject to change without notice.
**Mechanical Drawing
**
Power Supply
The M/GE-PSW-PSE-01 uses Power Supply 25188 for the -JP country bundle. The 25188 Power Supply is an external (desktop) power adapter with a 2-Pin barrel connector. Warning: You must either use the provided external AC-DC adapter or you must ensure that the alternate power source meets the IEEE 802.3at isolation requirements. The 25188 Power supply features include:
- Universal AC input/ Full Range
- Energy Efficiency Level VI
- ErP Step 2 Compliant
- NRCan and GEMS Compliant
- Output Protections: OVP/SCP/OCP
- No Load Power Consumption <0.21W
Power Supply Specifications
Output Characteristics
DC Output: 56V; Sufficient to support two RJ-45 PoE+ Powered Devices
(PDs)
Rated Current : 1.17A
Ripple and Noise: ±2% Vo @ Rated Load
Load Regulation (Typ.): ±5%
Transient Response (Typ.): 0.5mS for 50% Load Change
Hold-up Time (Typ.): 10mS @ Rated Load
Output Protection: Short Circuit, Over Voltage, Over Current protection
Input Characteristics
Voltage Range : 100VAC~240VAC
Frequency Range : 50Hz-60Hz
Efficiency: DoE Level VI, Energy Star, ErP Step 2, NRCan & GEMS Level VI
Certified
AC Current (max): 1.4A
Input Protection: Internal Primary Current Fuse, Inrush Limiting
Leakage Current: 0.25mA (2 Conductor), 3.5mA (3 Conductor)
Environmental Characteristics
Operating Temperature: 0°C~40°C
Operating Relative Humidity : 20% RH to 80% RH
Storage Temperature : -20°C~80°C, 10% RH to 90% RH
Topology: Switching Flyback
Dielectric Withstand: 3000VAC Primary-Secondary
EMI Conduction & Radiation: Compliance to EN55022 Class B
Harmonic Current: Compliance to EN61000-3-2, 3
EMS Immunity: IEC61000-4-2, 3, 4, 5, 6, 8, 11
Other Characteristics
MTBF : 300,000Hrs (25°C, Telcordia SR-332)
Dimensions (LxWxH): 115 x 53 x 38 mm (4.52 x 2.08 x 1.49 inches)
Weight: 310g (0.68 lbs.)
Power Supply Dimensions
The 25188 Power Supply dimensions are given below (in mm).
Troubleshooting
- Make sure the function you are trying to perform is supported on this device; see “Features” on page 4.
- Verify the install procedure was followed properly; see “Installation” on page 7.
- Check the front panel LEDs; see “Status LEDs” on page 9 and “LED Descriptions” on page 8.
- Ensure that the proper power supply is correctly connected; see “Power Supply” on page 12. If the power LED is blinking, it may indicate incorrect or faulty power supply, or that the power adapter is not the proper type of voltage and cycle frequency for the AC outlet.
- Make sure attached devices (SFP, WAP, IP camera, etc.) are installed properly and operating correctly; see the attached device’s documentation.
- Verify that the TX and RX cables on the converter are connected to the RX and TX ports, respectively, on the other device.
- Record device information.
- Contact Technical Support.
Problem: The Auto Power Reset feature only works once after cold boot;
subsequent tries to get the feature to power-cycle a PD fail to cut the PD’s
power.
Description: There is about a 5 minute time out set on this feature to
prevent constant power cycling of the PD, due to the boot time of some PD
devices taking a couple of minutes.
Solution: Wait for a couple of minutes for the PD device to boot.
Lantronix Corporate Headquarters
7535 Irvine Center Drive Suite100 Irvine, CA 92618, USA
Toll Free: 800-526-8766
Phone: 949-453-3990
Fax: 949-453-3995
Technical Support
+1.952.358.3601, 1.800.260.1312, or
techsupport@transition.com
Sales Offices
For a current list of our domestic and international sales offices, go to
www.lantronix.com/about/contact.
References
- Patents | Lantronix
- Contact Us | Lantronix
- Small Form-factor Pluggable (SFP) Transceivers | Lantronix
- Intelligent IoT Solutions - Connect, Compute, Comprehend, Control