ALLEGION LCN 4031 Series Relcross Door controls User Guide
- June 15, 2024
- Allegion
Table of Contents
LCN 4031 Series Relcross Door controls
User Guide
LCN 4031 Series Relcross Door controls
The 4031 Series is a non-handed, surface mounted closer. The choice of three
mountings, installation accessories and ease of installation offer a versatile
solution to door control in moderate traffic applications.
The 4031 Series has been designed to be used on aluminum, hollow metal or
timber swinging commercial interior/exterior doors and is ideally suited for
apartment entrance, office, storeroom or toilet doors.
Features
-
Universal, fully reversible, non-handed door closer
-
Closer cylinder constructed of high strength cast iron for increased durability
-
Tested to 1,500,000 cycles
-
Fully adjustable 1-4 strength
-
Factory set to strength 3
-
Standard closer offers 3 installation options
– Regular (pull side)
– Top jamb (push side)
– Parallel arm (push side) -
Independent adjustment valves for backcheck, closing and latching speeds
-
All adjustment valves are concealed behind the cover to prevent tampering
-
Closers installed according to LCN installation instructions require minimal periodic maintenance or adjustments.
Specification guide
Warranties
Mechanical| 30 years
Series
CN 4031 Series | LLCN4031 |
---|
Function
Regular | R |
---|---|
Hold open | HO |
Finish
Aluminum | ALUM |
---|---|
Dark Bronze | DBZ |
1. Series Select the desired series e.g. LCN 4031 Series | LCN4031 |
--- | --- |
2. Function Select the required function | LCN4031HO |
3. Finish Select the desired finish e.g. Aluminum | LCN4031HOALUM |
Finishes
*Additional custom colours available using the RAL colouring system
**LCN also offers a special rust inhibiting process (SRI) as required
Specifications
Door type` | Timber or metal |
---|---|
Door size | External door 660mm – 914mm Internal door 660mm – 1219mm |
Applications | Regular – pull side mount Parallel arm – push side mount Top |
jamb – push side mount
Adjustment controls| Closing speed Latching speed Backcheck
Strength| 1-4 adjustable
Options| Hold open arm Adaptor plate Parallel arm drop plate Square metal
cover
SRI| For installations where a higher level of protection against weather
conditions, or the effects of a potentially corrosive atmosphere is required,
LCN offers a special rust inhibiting (SRI) process. Ferrous metal components
receive an SRI pretreatment and a standard powder coat finish of your choice,
or a custom powder coat finish for a nominal additional cost. Closers treated
with the SRI process exceed the 100 hour protection level available with
standard LCN powder coated finishes.
Testing and Compliance
Fire Rating:
Successfully tested on fire door assemblies in accordance with AS1905 Part1:
Fire resistance doorsets. Check with fire door manufacturer prior to
installation.
Accessibility:
Compliant to the AS 1428:1-2009 Design for Access and Mobility
Caution:
When door closers are installed and adjusted to meet reduced opening force
requirements, there may be insufficient power to reliably close and latch the
door, depending on prevailing operating conditions.
Note:
In areas of high wind pressure and/or air conditioning pressures, the LCN
Automatic Door Operators are recommended.
Selection chart
Select strength based on width of door
Strength | Exterior door | Interior door |
---|---|---|
1 – 2 | NA | 660mm – 864mm |
3 | 660mm – 762mm | 864mm – 965mm |
4 | 762mm – 914mm | 965mm – 1219mm |
Regulating controls
The LCN 4031 has independent regulators to control:
Closing speed| Adjustment to increase or decrease the speed at which the door
closes. This allows the appropriate momentum to
close the door in a safe and secure manner. Closing speed adjustment operates
from the maximum opening to 15°
---|---
Latching speed| The latching speed allows the door to close quietly and
firmly. It can be adjusted to increase or decrease the speed
at which the door finally closes. This assists the final stage of the closing
cycle to help overcome stubborn latch bolts or air pressure conditions.
Alternatively the latching speed can be decreased to cushion the door into the
frame. The latching speed adjustment operates from 15° to closing. A further
option to increase the latching power is to reverse the arm bracket shoe
Backcheck| Adjustable hydraulic backcheck provides a cushioning effect when
the door is forcibly thrown open to prevent damage to the closer, door and
frame. The backcheck adjustment allows the level of resistance in the latter
stage of opening to be set at the level required. Backcheck is effective from
75° . Backcheck is a requirement for all fire rated closers
Power adjustment| Spring strength may be increased or decreased by turning the
allen head screw located in the end of the door closer body
Functions
Regular | For applications where the door must fully close after each opening |
---|---|
Hold open | Suitable for doors where the door may need to be left in a hold |
open position. The hold open function can be set to stay open at a single point. Hold open closers can not be used on fire doors
Mounting details
Regular (pull side) mounting
Templating allows a maximum opening of 180° . The hold open arm allows the
door to be set at a given hold open point up to the maximum opening. The
reveal should not exceed 6mm for both regular and hold open arms. A top rail
less than 60mm requires adaptor plate. The adaptor plate requires a top rail
of 44mm. A clearance of 41mm behind the door is required for 180°
installations Top jamb (push side) mounting
Templating allows a maximum opening of 180° . The hold open arm allows the
door to be set at a given hold open point up to the maximum opening. A reveal
up to 102mm allows 180° opening. A top rail of 38mm is required for top jamb
mounting. For situations where the head frame is less than 57mm, an adaptor
plate is required. The adaptor plate requires a 38mm minimum head frame
Parallel arm (push side) mounting
Templating allows a maximum opening of 180°. The hold open arm allows the door
to be set at a given hold open point up to the maximum opening. Clearance for
the PA Shoe is 102mm from door face. A top rail less than 114mm measured from
the stop requires a drop plate. The drop plate requires a 44mm top rail.
Minimum stop width is 25mm
4031 Series accessories
Regular arm 4030-3077
Standard, non-handed arm for regular and top jamb mounting configurations. For
parallel arm mounting, a PA Shoe is also required
Finish: Aluminum Hold open arm 4030-3049
Non-handed, hold open arm for regular and top jamb mounting configurations.
For parallel arm mounting, a PA Shoe is also required. Hold open adjustable at
shoe
Finish: Aluminum PA shoe 4030-62PA
Required for parallel arm mounting configurations Metal cover 4030-72
Standard, non-handed cover, providing complete enclosure of closer body.
Finish: Aluminum Square metal cover 4030-MC
Non-handed cover, providing complete enclosure of closer body.
Finishes: Polished stainless steel, satin stainless steel Adaptor plate
4030-18
Mounting plate required for top jamb mounting where headframe is less than
60mm or a flush ceiling condition exists Drop plate 4030-18PA
Mounting plate required for parallel arm mounting configuration where top rail
is less than 114mm, measured from the stop. A drop plate requires a 44mm
minimum top rail © Allegion 2021. All rights reserved. Material and design
specifications subject to change without notice. Product colour reproduction
is as near to actual product colour as production methods allow. Warning:
Products in this brochure are the subject of registered designs and patents.
This brochure relates to Australian and New Zealand products only and some
product, design or specifications may differ in other countries.
Read User Manual Online (PDF format)