VACUUM OIL & FLUID EXTRACTOR
& DISCHARGE 6LTR & 18LTR
MODEL NO’S: TP6905.V2, TP6906.V2
TP6905.V2 Vacuum Oil and Fluid Extractor and Discharge
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND
WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE
INSTRUCTIONS SAFE FOR FUTURE USE.
|
---|---
Refer to instruction manual| Wear protective gloves
|
Wear face shield| Wear protective clothing
SAFETY
‰ WARNING! Ensure Health & Safety, local authority, and general workshop
practice regulations are strictly adhered to when using this equipment.
IMPORTANT! Ensure that you wear protective clothing, gloves, goggles,
face mask as appropriate for the fluid being extracted.
Keep the extractor clean and
maintain it in good condition (use an authorised service agent).
Replace or repair damaged parts.
Use genuine parts only. Unauthorised parts may be dangerous and will
invalidate the warranty.
Check extractor connections and
fittings before use. When the unit is in use check that there are no leaks.
Ensure that the extractor’s tank
capacity exceeds the amount of fluid to be collected.
Ensure that the end of the
suction tube is fully submerged in the fluid before operating.
When not in use store in a safe,
dry, childproof area.
Keep the work area clean,
uncluttered and ensure there is adequate lighting.
Maintain correct balance and
footing. Ensure the floor is not slippery and wear non-slip shoes.
Keep children and unauthorised
persons away from the working area.
Dispose of waste fluids in
accordance with local authority regulations.
‰ WARNING! DO NOT allow uncontrolled discharge of fluids thus
polluting the environment.
9 Use only to extract engine or transmission oils, or similar NON-corrosive
fluids. Unit may also be used for the transfer of water.
DO NOT use to extract hazardous or harmful chemicals, solvents, petrol,
diesel, kerosene, alkaline or acids. If by chance such fluids are used in the
unit, it must be immediately drained and thoroughly cleaned. Use with
prohibited fluids will invalidate your warranty.
DO NOT store fluids in the extractor’s tank. After extracting fluid, it must
be emptied into an approved receptacle as soon as possible.
DO NOT dismantle, tamper or adapt the extractor for any purpose other than for
which it is designed.
DO NOT store in areas of high temperature, direct sunlight, rain or snow.
DO NOT connect these units to an air compressor.
DO NOT dismantle these units.
DO NOT leave these units in a pressurised state.
‰ WARNING! When the extractor’s tank contains liquid that is under
pressure DO NOT remove or insert the extension tube connector into the
inlet/outlet fitting as this may result in a sudden discharge of liquid that
could be dangerous.
Always press the pressure relief
button before connecting or disconnecting the extension tube.
INTRODUCTION
6ltr (TP6905) or 18ltr (TP6906) capacity device constructed from composite materials and suitable for extraction of all types of engine, transmission and lubricating oils from cars, motorcycles, marine engines, stationary engines and industrial machinery. Features a controlled discharge function for emptying the unit. Suitable also for low viscosity fluids such as water. Supplied with Ø5.8, Ø6.7mm suction probes and a 1.1m extension tube. Uses probes to drain engine oil through the dipstick hole. Also suitable for draining fish tanks, basins and sinks.
SPECIFICATION
Model No: | TP6905.V2 | TP6906.V2 |
---|---|---|
Capacity | 6L | 18L |
Suction probes | Ø5.8 x 870mm, Ø6.7 x 870mm | Ø5.8 x 870mm, Ø6.7 x 870mm |
Extension tube | Ø9.8 x 1010mm No | Ø9.8 x 1010mm, |
Wheels | No | Yes |
MAIN FEATURES
Refer to fig.1
4.1. OUTLET BUNG
The outlet bung is inserted into a small spout in the top of the unit which
is used to manually empty oil out of the tank. The bung has an integral
pressure relief button built into it. Press the button downwards into the bung
and hold it there until the pressure has equalised.
4.2. BUNG RELEASE RING
To remove the bung take hold of the bung release ring and turn the bung anti-
clockwise until it stops. Pull upwards to remove the bung. To lock the bung in
place insert it into the spout and turn it clockwise until it stops. The hooks
on either side of the bung should now be trapped under the flanges on either
side of the spout.
4.3. IN/OUT VALVE LEVER
When the valve lever is moved to the ‘IN’ position, operating the pump handle
creates a vacuum, causing fluid to be sucked into the tank via the
probe/extension tube. When the valve lever is moved to the ‘OUT’ position,
operating the pump handle pressurises the tank causing fluid to be expelled
from the tank.
4.4. TANK
After the unit has been used the tank should not be left in either a vacuum or
pressurised state. Push in the pressure relief button and hold it down until
the pressure has equalised.
4.5. BASE
The base should be placed on a smooth level surface during operation.
4.6. FOOTREST
When extra stability is required during pumping fold out the footrest from
underneath the base.
4.7. PROBE Ø6.7
This is the larger of the two probes provided and is intended for insertion
into the dipstick tube of vehicles where an oil change is required. The red
plastic fitting on this tube is a push fit onto the extension tube.
4.8. PROBE Ø5.8
This is the smaller of the two probes provided and is intended for
insertion into the dipstick tube of vehicles where an oil change is required.
The black plastic fitting on this tube is a push fit onto the extension tube.
4.9. EXTENSION TUBE Ø9.8
The fitting at one end of this tube fits directly into the Fluid
inlet/outlet ‘13’. One of the probes will be a push fit onto the other end of
this tube.
4.10. SUCTION TUBE HOLDER
The extension tube and the two probes can be stored here when not required.
4.11. CARRYING HANDLE
The pump handle should be in the down position to use the carrying handle.
4.12. PRESSURE GAUGE
The needle moves anti-clockwise from zero when a vacuum is created to suck
fluid into the tank. The needle moves clockwise from zero when the tank is
pressurised to expel fluid from the tank. If the needle moves into the red
zone the excess pressure will be automatically released.
4.13. FLUID INLET OUTLET
This fitting has a sliding sleeve which has to be pulled downwards before
the fitting on the end of the extension tube will go in.
4.14. PUMP HANDLE
The pump handle should be moved up and down through its full stroke for most
efficient operation of the pump. If the pump handle locks up this means the
tank is full. Press the pressure relief button to free the handle.
OPERATION
5.1. SET UP FOR OIL CHANGE
NOTE: Ensure you read, understand and apply the Section 1 Safety
Instructions and consult manufacturer’s workshop manual for any specific
procedures.
5.1.1. Ensure that the vehicle is level. Run the engine for approximately
five minutes to ensure that the oil is warm. Switch off engine.
5.1.2. Remove the oil dipstick from the engine.
5.1.3. Insert the appropriate extracting probe into the dipstick tube
making sure it reaches the bottom of the sump. Connect the extracting probe to
the extension tube using the black or red soft plastic adaptor. The tubes are
a push fit into the adaptor (fig.2).
5.1.4. Position the extractor close to the front or side of the vehicle.
Plug the extension tube fitting into the fluid inlet/outlet fitting on top of
the extractor (see fig.1-13).
5.2. DRAWING FLUID INTO THE EXTRACTOR
5.2.1. Before operating the extractor you must press the pressure release
button (see fig.1-1) to dissipate any vacuum or pressure remaining in the tank
from previous use. The pressure gauge needle should return to the zero
position.
NOTE: The extractor should never be stored with any vacuum or pressure
left within the tank.
5.2.2. Set up the unit for oil extraction as described in Sections 5.1.1
to 5.1.4 so that the extractor probe is inserted into the vehicle’s dipstick
tube. The other end of the extractor probe should be joined to the extension
tube with the adaptor provided and the extension tube should be connected to
the inlet/outlet coupling (See fig.1-13).
NOTE: Extraction via the dipstick tube should only be done whilst the oil
is warm.
5.2.3. Move the IN/OUT valve lever to the IN position as shown in fig.4.
5.2.4. Fold out rod foot rest as shown in fig.1-6. (not applicable on
TP6905.V2).
5.2.5. To commence suction place your foot over the foot rest to steady
the unit and start to pump the handle up and down through its full travel. The
needle on the gauge should move anti-clockwise from the zero position as shown
in fig.3.
5.2.6. As you pump up and down, the tank will begin to fill. When the
tank is full the auto shut off mechanism will operate and the pump handle will
lock up. To return the handle to the down position hold down the pressure
relief button and push the handle down.
5.2.7. Remove the extractor probe from the dipstick tube and replace the
dipstick.
5.3. EXPELLING FLUID FROM THE EXTRACTOR
5.3.1. Place the end of the extension tube into a suitable container
ensuring that it is large enough to hold the volume of liquid in the
extractor’s tank.
5.3.2. Move the IN/OUT valve lever to the OUT position as shown in fig.6.
5.3.3. Fold out rod foot rest as shown in fig.1-6.
5.3.4. To empty the extractor’s tank place your foot over the foot rest
to steady the unit and start to pump the handle up and down through its full
travel. The needle on the gauge should move clockwise from the zero position
as shown in fig.5. If excess pressure is created the needle will move into the
red zone and the pressure will be automatically relieved.
5.3.5. As you pump up and down, the tank will begin to empty.
Continue pumping until all fluid has been expelled.
When the tank is empty, press the pressure relief button to dissipate any
residual pressure remaining in the tank. If extracted oil has cooled down and
thickened we recommend that it should be poured from the extractor tank.
5.3.6. Remove the outlet bung from the pouring spout as described in
Sections 4.1 and 4.2.
5.3.7. Pour the oil from the tank as shown below (fig.7). DO NOT over tip
the unit as this will result in inconsistent flow form the tank.
5.3.8. Insert the bung into the spout and turn fully anti-clockwise to
lock in position for future use.
‰ WARNING! When the extractor’s tank contains liquid that is under
pressure DO NOT remove or insert the extension tube connector into the
inlet/outlet fitting as this may result in a sudden discharge of liquid that
could be dangerous. Always press the pressure relief button before connecting
or disconnecting the extension tube.
Parts support is available for this product. Please email
sales@sealey.co.uk or telephone 01284 757500
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
REGISTER YOUR PURCHASE HERE
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. If you require documentation for alternative versions, please
email or call our technical team on
technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way,
Suffolk Business Park, Bury St Edmunds,
Suffolk. IP32 7AR
01284 757500
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
TP6905.V2, TP6906.V2
Issue:5 (3) 04/05/23
Documents / Resources
|
SEALEY TP6905.V2 Vacuum Oil and Fluid Extractor and
Discharge
[pdf] Instructions
TP6905.V2 Vacuum Oil and Fluid Extractor and Discharge, TP6905.V2, Vacuum Oil
and Fluid Extractor and Discharge, Fluid Extractor and Discharge, Extractor
and Discharge
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>