Product Information
Specifications
- Model: 120 x 220 cm
- Max. clearance distance (W x H): 116 x 214 cm
- Installation depth: 11 mm
Product Usage Instructions
Introduction
To ensure the most seamless assembly possible, read the following safety
information and assembly instructions carefully and keep the manual handy for
future reference. The manual is part of the product and takes you step by step
to the finished insect screen. Please include when passing the product on to
third parties.
Safety Information
WARNING! The signal word is used for medium-risk danger, which, when not
avoided, can lead to death or heavy injury.
ATTENTION! The signal word is used for low risk danger, which, when not
avoided, can lead to light or moderate injury.
ATTENTION! There is a risk of injury through improper assembly and use of
tools. Use work gloves, if necessary. Incomplete assembly kits or damaged
parts may, under no circumstances, be used for assembly. Function and safety
can thus be impacted. Protect the product and any flammable parts from heat
waves and fire.
Installation
Consider the safety information and follow assembly steps 1 to 20. Use the
required tools carefully to avoid injuring yourself or others.
Cleaning
Clean your insect screen regularly with a damp fibre cloth. Only use mild
cleaning products, if required, to avoid damaging the product.
Disposal
Dispose of the packaging material (boxes, foils, etc.) separately through a
recycling collection point. The disused product can also be disposed of
through a collection point. Information on this matter can be obtained from
your local authority or city administration.
Contact Information
If you have any questions regarding the product or assembly, please contact
us:
- Germany: 0800 6161 123 / germany@windhager.eu
- Austria: 0800 080 616 / austria@windhager.eu
- Switzerland: +41 4176 6054-0 / swiss@windhager.eu
- France: +33 390 6459 79 / france@windhager.eu
FAQ
What should I be aware of when cutting?
Shorten the aluminum sections with a metal saw. A mitre box will ensure an
exact cut. If necessary, attach the parts which are to be shortened via a
screw clamp in the mitre box, without squashing it.
CONTENTS
REQUIRED TOOL
OVERVIEW
INTRODUCTION
To ensure the most seamless assembly possible, read the following safety
information and assembly instructions carefully and keep the manual handy for
future reference. The manual is part of the product and takes you step by step
to the finished insect screen. Please include when passing the product on to
third parties.
PROPER USE
The product protects the user from flying insects in living areas by attaching the former to window and door frames. Application of the product for other purposes, as well as changes to the product are prohibited and can cause personal injuries, and damage the product. The manufacturer takes no responsibility for ensuing damages to the product as well as general damages through assembly. The product is not intended for commercial use. Use during freezing temperatures can damage the product.
LEGEND
WARNING! The signal word is used for medium-risk danger, which, when not
avoided, can lead to death or heavy injury.
ATTENTION! The signal word is used for low-risk danger, which, when not
avoided, can lead to light or moderate injury.
SAFETY INSTRUCTIONS
WARNING! Potentially life-threatening risk of injury to children and
babies! The product is not a toy. Never leave your child alone or unattended
with the product. The packaging and contents pose a risk of suffocation,
strangulation and injury. Children are not aware of these dangers. Due to the
danger of falling, only attach the product to windows and doors which can be
accessed from outside without risk. When attaching or removing the product,
please don’t lean out of the window and don’t press against the insect screen
from inside.
ATTENTION! There is a risk of injury through improper assembly and use of
tools. Use work gloves, if necessary. Incomplete assembly kits or damaged
parts may, under no circumstances, be used for assembly. Function and safety
can thus be impacted. Protect the product and any flammable parts from heat
waves and fire.
TECHNICAL DATA
- Model: 120 x 220 cm
- Max. clearance distance (W x H): 116 x 214 cm
- Installation depth: 11 mm
SCOPE OF DELIVERY
Check the scope of deliver directly after unpacking to ensure everything has been included and there are no faults. Begin the assembly only when you are sure that all parts are present and undamaged. Do not accidentally dispose of assembly materials when disposing of the packaging material.
INSTALLATION
Consider the safety information and follow assembly steps 1 to 20. Use the required tools carefully, to avoid injuring yourself or others.
-
Measure the clearance width measurement B, by measuring the horizontal inner distance to the open window. Measure the clearance height measurement H, by measuring the vertical inner distance to the open window.
Attention: You will need a contact area of at least. 23 mm to the sides, 36 mm above, and 30 mm below the window, in order to mount the insect screen frame.
Notice: Take care to take the measurements in millimeters. 1 cm = 10 mm -
Mark both sections 1 with measurement B minus 26 mm. Shorten both sections 1 at the marked point with a metal saw.
Example: Measured clearance width B = 1100 mm – 26 mm = 1074 mm
Attention: Risk of injury! Use the saw with caution. -
A. Mark both sections 2a with measurement H minus 1033 mm. Shorten both sections 2a at the marked point with a metal saw.
Example: Measured clearance height H = 1800 – 1033 mm = 767 mm. Both lower height sections 2b (1009 mm section length) are not to be shortened!
Attention: Risk of injury! Use the saw with caution.
B. For windows with a rain guard (e. g. wooden windows), the frame must align with the rain guard in order to seal the window. To do this, mark both sections 2a with measurement H + z – 1063 mm. Shorten both sections at the
marked point with a metal saw.
Example: Measured clearance height H = 1800 mm, z = 50 mm (distance of lower frame part to the rain guard) >>> 1800 mm + 50 mm – 1063 mm = 787 mm.
Note: Risk of injury! Use the saw with caution. -
Mark the middle section 4 with measurement B minus 26 mm.
Example: Measured clearance width B = 1100 mm – 26 mm = 1074 mm. Shorten the middle section at the marked sections with a metal saw.
Note: Risk of injury! Use the saw with caution. -
Deburr the cut surfaces between sections 1, 2a, and 4 with a file.
-
A. Calculate the blind frame thickness X (the outermost part of the window frame) of your window using a tape measure. Bend the four fastening springs 5a and 5b using the bending device 5c to the calculated dimension and add 3mm. For this purpose put the fastening springs 5a and 5b into the bending device 5c as shown and bend them to a 90-degree angle. The scale of the dimension to be bent is located at the inner edge of the fastening spring.
Example: Measured blind frame thickness X = 14 mm + 3 mm = 17 mm .
B. For windows with a rain guard (e. g. wooden windows) measure the blind frame strength X1 (above) and X2 (below) of the window frame with measuring tape. The blind frame is the outermost frame section when the window is open. Mark the upper blind frame measurement X1 plus 3 mm from the fastening springs 5a and the lower blind frame measurement X2 plus 3 mm from the fastening springs 5b. Bend the fastening springs 5a and 5b using the bending device 5c. For this purpose put the fastening springs 5a and 5b into the bending device 5c as shown and bend them to a 90-degree angle. The scale of the dimension to be bent is located at the inner edge of the fastening spring. -
Connect vertical profiles 2a and 2b via the central connector 12a. Use a rubber mallet.
-
Insert the suspension springs 5b into the dedicated recess in the middle corner 12a. Connect the middle corners 12a with the middle section 4. Use a rubber mallet.
-
Attach the covering caps 12b to the central connector 12a.
-
Connect the sections 1 and 2a/2b with corner connectors 3 to a frame.
-
Place the sealing brush 9 on the outward upper groove of sections 1 and 2a/2b and press it with the thin tip B of the welt tool 8 in the die groove.
-
Shorten the sealing brush 9 with scissors to match the recess length. Roll the material 11 over the frame.
-
Attach material 11 with a rubber welt 10 to the welt grooves 1, 2a/2b, and 4. Use the wide side A of the welt tool 8 to do this. Shorten the welt 10 with scissors after you have attached it all around.
-
Shorten the material 11 outside along the welt 10 with a cutter.
-
Attach the upper suspension springs 5a 36 mm away from the frame with the screws 6. Careful: do not over-tighten the screws.
-
A. Attach the lower suspension springs 5b 30 mm away from the frame with the screws 6. Careful: do not over-tighten the screws.
B. Attach the lower suspension springs 5b with the determined distance z (e.g. 50 mm) to the frame with the screws 6. Careful: do not over-tighten the screws. -
Link the left and right grip elements to units 7a and 7b and insert the metal pins 7c into the recesses to connect.
-
Screw the grips 7a and 7b left and right with screws 7d into the screw groove of the frame sections 2b.
-
The insect screen is now ready for mounting. Open your window and place your insect screen frame. Guide the upper suspension hooks 5a into the blind frames from outside. Pull the frames in and push them out so the the lower suspension springs 5b attach behind the blind frame. Stay safe and do not lean out of the window – danger of falling!
-
Push the fixation springs 5b outwards in the middle connectors 12a and thus fix the window in the middle.
INSTALLATION VIDEO
Assembly videos for this product can be viewed on
windhager.eu as well as via a QR code (see bottom
right)
CLEANING
Clean your insect screen regularly with a damp fiber cloth. Only use mild cleaning products, if required, to avoid damaging the product.
DISPOSAL
Dispose of the packaging material (boxes, foils, etc.) separately through a recycling collection point. The disused product can also be disposed of through a collection point. Information on this matter can be obtained from your local authority or city administration.
MANUFACTURER/SERVICE
Do you have questions about the product or assembly?
Contact us:
FROM GERMANY: 0800 6161 123
FROM AUSTRIA: 0800 080 616
germany@windhager.eu
austria@windhager.eu
FROM SWITZERLAND: +41 4176 6054-0
FROM FRANCE: +33 390 6459 79
swiss@windhager.eu
france@windhager.eu
FAQ
-
What do I do if the delivery is missing some parts?
Only begin assembling the product when a replacement part has been delivered. If the scope of delivery is missing some parts or contains damaged parts, then you will receive a replacement free of charge. Send us your purchase receipt and article number via email. Should parts be lost or damaged by improper use, then they can be purchased through our spare part and accessory range. Contact us! -
Where can the product be attached?
The frame is attached to the outside of the window frame via suspension springs and can be dismantled at any time. You can also permanently attach the frame to the window frame using accessories. -
What should I be aware of when cutting?
Shorten the aluminium sections with a metal saw. A mitre box will ensure an exact cut. If necessary, attach the parts which are to be shortened via a screw clamp in the mitre box, without squashing it. -
What should I be aware of when attaching the material?
Refrain from additionally stretching the material when sliding on the rubber welt to avoid warping the frame. The welt is best attached when tensioned.
Note: Subject to mistakes, changes and setting errors. Current version of the manual as a PDF download on windhager.eu Date of information: 03/2022
Windhager Handelsgesellschaft m.b.H.
Industriestraße 2, A-5303 Thalgau
+43 6235 6161-0, windhager.eu