Installation, Operation, and Maintenance Guide
SeltzaHub/ SeltzaTap/ SeltzaTap Compact
1700346343 Chilled Sparkling Water Kitchen Tap
Tecnical Specifications
Voltage | 120V 60Hz |
---|---|
Current | 4A |
Chilled still water capacity | 3 litre/ hour |
Soda water capacity | 4-6 litre/ hour |
Refrigerant Type and Charge | R134a 55grams |
Cooling temperature | 2-12°C |
CO2 inlet pressure | 65-80 psi |
Water inlet pressure | 29 – 60 psi |
A-Weighted Sound Pressure Level | 40 to 50 dB |
SeltzaHub only weight | 17.5kg (38.6 lbs) |
Packaging weight | 20.0kg (44.1 lbs) |
What’s included?
- SeltzaHub
- CO2 Regulator with TR21-4 threads (Soda Stream style cartridge)
- Regulator adapter to CGA-320 (Larger style CO2 Tanks 5, 10, 20 lbs)
- T-Stop Valve
- Tubing as per below
- Power Cord
Installation
Overall view of installation
- Ensure the SeltzaHub is put into the proposed installation location 24hours before starting up. This ensures there will be no issues with refrigerant system.
- Turn off cold water from existing valve under the sink.
- Disconnect existing cold water lines from existing valve.
- Install T-Stop Valve in existing cold water line.
- Connect cold water faucet hose to the T-Stop valve.
Sample image under the sink
Check for leaks. Ensure T-Stop Valve is turned off. Turn on Main Cold Water supply and check for any leaks. (Show picture of T-Stop valve off and Main water on)
How To Use Quick Connect Fittings
-
Cut the tube square and push into the tube stop. For metal tube, remove burrs and chamfer tube end to prevent O-ring seal from being damaged.
-
Fitting grips before it seals. Ensure tube is pushed into the tube stop.
-
Tube is secured in position
-
DISCONNECTION PROCEDURE Push collet against body and slide tube out fitting.
-
Disassemble the blue safety clip and take out the plug. (if applicable).
-
Connect the 1/4” diameter water pipe to the T-stop valve or the filter system and the SeltzaHub water inlet.
-
Connect the chilled sparkling, chilled still, and ambient still 5/16” tubing from SeltzaHub to SeltzaTap.
For third party faucets modify connections to work with the SeltzaHub -
Check for water leaks in the system.
a) Ensure all the valves on the side of the machine are off.
b) Turn on Main water valve. Check for leaks
c) Turn on T-Stop valve Check for leaks
d) Turn on Each valve on the side of SeltzaHub and wait for 5 seconds. Check each valve for leaks.
e) Leave valves open -
Take the 5/16” gas tubing, cut as needed and assemble the tubing to the pressure reducer.
-
Connect 5/16” tube in the back of the SeltzaHub to CO2 inlet.
-
Assemble the pressure reducer to the CO2 cylinder. Ensure regulator is off. Turn counter-clockwise till it stops.
-
Plug in and turn on power. Let the cooling system inside the SeltzaHub cool and carbonate for 20 minutes. You should hear the pump feed water into the machine and the compressor start up.
-
10 minutes after turning power on adjust the CO2 pressure regulator to 75 psi. Ensure no CO2 leaks
-
20 minutes after operation open the faucet valve and let 500ml (16 oz) of sparkling water.
-
Wait 20 minutes to let the system re-cool and then tap 500cc of sparkling water.
-
Let system cool for 20 minutes.
Operation
Button functions
No | Name and function | Comments |
---|---|---|
1 | LED Lamp — status of the cooling system | Show temperature of the cooling |
Error: Fault of the machine (see detail below)
2| Temperature adjustments| Press 2 for five seconds, button 3 and
4 will start to shine, then adjust the temperature (from 2-12 )
press 3 , temperature goes up.
press 4 , temperature goes down.
Back side of the machine
No | Name and function | Comments |
---|---|---|
3 | Operational buttons | ON – OFF button |
4 | CO2 inlet (5/16” = 7.95mm) | CO2 gas to be 65-80 Psi |
5 | Water inlet (1/4” = 6.35mm) | Water pressure to be 29-65 Psi |
SeltzaHub Maintenance
Replacing the temperature sensor.
The temperature sensor has a limited life span.
A new one is included inside the top of the machine.
- Turn off SeltzaHub.
- Remove 2 screws at the back and top of the SeltzaHub.
- Remove plastic cover.
- Remove elastic band around temperature sensor.
- Pull temperature out of well.
- Follow the wire back and remove from connect marked CN 16 on board.
- Install in reverse.
Flow Rate Adjustment
It is possible to adjust the flow rate up or down inside the SeltzaHub. This
may increase the instance of E4 error codes and is not detrimental to the
machine.
- Turn off SeltzaHub
- Remove 2 screws in the back top of the SeltzaHub
- Remove the top cover
- Locate the flow regulator. Mark the current screw location with a marker in case you want to go back to the factory setting of 15 mL/second.
- Turn flow regulator screw counter clockwise for increased flow. Turn clockwise for decreased flow.
Potential faults and actions to be taken
No | Fault | Actions to be taken | Comments |
---|---|---|---|
1 | When using the Soda water, gas comes out of the Seltzer Tap. | Recommended | |
to wait a little, then problem will be solve by itself. | This happens when |
taking to much soda water at one time.
2| Machine is not working properly| Recommended to shutdown the machine and
re-operate it after 30 seconds.|
3| SeltzaHub display error| E1| NTC connection is open.| Replace temperature
sensor as per maintenance instructions
E2| NTC is short-circuited.| Replace temperature sensor as per maintenance
instructions
E3| Temperature is too low.| Shut down the machine, restart after 30 seconds.
E4| Pump Protection as the pump is working to long.| Shut down the machine,
restart after 30 seconds.
E5| Compressor protection, the compressor works too long time| 1. Check for
proper ventilation under the counter.
2. Check that fan is operational and that is not blocked.
3. Check the temperature shown on the front of the display. If it shows 35 or
more than the temperature sensor needs replacement. See maintenance
requirements below.
4. Room temperature may be to high.
4| Soda not working or flat| CO2 bottle is empty.| Replace CO2 bottle.
Power is off.| Turn on the power switch.
Not enough bar pressure.| Slightly increase CO2 bar pressure.
5| Noise| If there are any unusual NOISE, shutdown the SeltzaHub, close the
water inlet and gas inlets.| Do not try to fix the machine. Shutdown the
machine and contact Seltzer customer support.
6|
| This marking indicates that this product should not be disposed with other
household wastes.
To prevent possible harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable reuse of
material resources.| Correct Disposal of this product.
WARRANTY
Any claim under this warranty must be made within 1 year of the date of
purchase of the product. This product is warranted to be free of defect of
material and workmanship for 1 year from date of purchase. To make claim under
warranty, take the product and proof of purchase to place where you purchased
the product, and they will lodge a Warranty Request Seltzer.
The warranty only applies if the product was used and/ or installed in
accordance with the user guide and/or installation instructions. This warranty
is given in lieu of all other express or implied warranties and manufacturer
shall in no circumstance be held liable for damages consequential or
otherwise or delays caused or faulty manufacturing except as excluded by law.
Applicable to all above, is that the warranties need to be approved by Seltzer
to ensure product was not incorrectly used, installed or claimed. False and
incorrect claims will be pursued at Seltzer discretion, including chargeable
inspection and Labour costs incurred.
Technical Specifications
Countertop hole and thickness requirements
90 cm long 5/16 inch PE tubing
Blue tubing = Chilled Seltzer
White Tubing = Chilled Still
Clear Tubing = Ambient Still
Ensure the SeltzaHub is put into the proposed installation location 24hours
before starting up.
This ensures there will be no issues with refrigerant system.
SeltzaTap Operation
SeltzaTap Maintenance
Changing Cartridges
Sparkling water (Left Hand Cartridge)
- Turn the water off to the faucet at the SeltzaHub valves.
- Put a piece of painters tape between the faucet body and handle to have a clear line to line it up when reinstalling it.
- Loosen set screw below. (Set screw is a 2.5mm hex screw)
- Remove the nut with an adjustable wrench.
- Check the gasket is in good condition (Not shown and is between the nut and cartridge below).
- Pull out old cartridge
- Install new cartridge ensuring the tabs lineup.
Regular water (Right Hand Cartridge)
- Turn the water off to the faucet at the Hot and Cold valves below sink. (As shown.)
- Loosen set screw 6 below. (Set screw is a 2.5mm hex screw)
- Remove 4 below by screwing out with hand
- Remove the nut with an adjustable wrench ( 3 )
- Check the gasket is in good condition (Not shown and is between 3 and 8 below)
- Pull out old cartridge
- Install new cartridge ensuring the tabs lineup
SeltzaTap Compact
Identical installation as SeltzaTap. Only differences are in the operation and dimensions. See below.
Countertop hole and thickness requirements
90 cm long 5/16 inch PE tubing
Blue tubing = Chilled Seltzer
White Tubing = Chilled Still
Clear Tubing = Ambient Still
SeltzaTap Compact Operation
CONFORMS TO UL STD.399
Certified to CSA STD C22.2 NO.120
Documents / Resources
|
SELTZA 1700346343 Chilled Sparkling Water Kitchen
Tap
[pdf] Installation Guide
1700346343 Chilled Sparkling Water Kitchen Tap, 1700346343, Chilled Sparkling
Water Kitchen Tap, Sparkling Water Kitchen Tap, Water Kitchen Tap, Kitchen
Tap, Tap
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>