TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet Instruction Manual

June 14, 2024
TEISVAY

SMART TOILET
INSTRUCTIONS FOR THE USE OF PRODUCTS TEISVAY UI 300 Smart Auto Lid
Smart Bidet Toilet

Note: gearing and use before please to cautiously read this manual Please the warning and regulation of obeying the product manual inside marking.

Safety directory

Please cautiously read before installing and using.

Warning-To avoid electric shock

  1. Do not place the product where it may get wet.
  2. Do not drop the remote control into the water.
  3. Do not spray water into the product or plug.

Warning: To prevent the possibility of burns, electric shocks, fires and injuries.

  1. Young children, temperature insensitive users, when using this product, should be accompanied by others. And turn off or lower the seat temperature.

  2. The product is limited to the function on the manual, do not use other equipments.

  3. Do not continue to use when the product is out of order, damaged or flooded.
    Please send the product to the designated repair center for repair.

  4. Please make sure that the wires are not damaged by burning.

  5. Do not use this product when you are out of your mind.

  6. Do not plug the product or pipe.

  7. Do not used outdoors.

The first use of Intelligent toilet

Note: To ensure the normal use of the product, please follow the instructions to text.

  1. Insert the power plug into the AC (AC) 110V socket
  2. Please confirm whether the indicator of the digital display panel is lit
  3. Confirm whether the inlet valve is take on
  4. Whether the hose between the wall Angle valve and the toilet inlet valve is installed in place

TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet - Power
plug

Caution-Confirmed matters before using

  1. Check whether the sprinkler head and water pipe leak, dry all parts of the water pipe and check with blotting paper.
  2. Press the seat around the seat sensor, whether there is a sound.
  3. Check whether the cleaning, drying, automatic deodorization and automatic flushing are normal
  4. Whether the Damped structure is normal.
    TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet -
using

Check the functions of cleaning, drying and automatic deodorization, make sure the sensor is on.When cleaning, cover and block the spray nozzle, so as not to splash.

Safety Caution

Note: please cautiously read before using

Please read carefully before using.
The cautions listed here are related to safety and please follow

Must obey

| Notice heat burn
– Please turn the seat temperature down or off when sitting on the toilet for a long time.
– Please set the temperature to room temperature when the following persons use the seat  to dry gently.
– Children, the elderly, the sick, the disabled, etc.
– People who take sleeping pills, get drunk and get overtired.
---|---
| Please don’t sprinkle water or rinse on product essence or the power plug.
– May arouse a fire or get an electric shock
– May cause toilet break, damage or indoor seepage.
| When long time didn’t use, please pull out the power plug.
– For safety, please pull out the power plug
– For re-use, please drain water for one minute before use.
| Do not use any power source other than AC 110V
– It may start a fire
| Please do not flush other items except for urine and feces
– May cause then block, sewage outside overflows.
| Keep cigarettes and other fire kindling away from the product
– It may start a fire
| Do not unplug the power plug with wet hands
– It may cause electric shock
| Do not use loose and unstable power sockets
– It may cause fire or electric shock
| Do not distort or damage the water inlet
– It may cause a leak

Prohibit

| Do not continue to use the product when it breaks down
When the following occurs, please unplug the power plug, close the inlet Angle valve, stop  the inlet.
– Ceramic WC is leaking
– Cracks appear
– Abnormal sound and smell
– Fume-off
– Abnormal heating
– The toilet is clogged
– If continued under the condition of failure,  it may cause fire, electric shock or indoor seepage problems
---|---
| Do not damage the power cord or toilet seat cable
– Don’t pull
– Don’t process
– Don’t heat
– Don’t forcibly bent
– Do not place heavy objects on the power cord and toilet seat connection line.
– May cause fire, electric shock or short circuit. If the power supply is damaged, please  contact a professional for repair.
| Do not disassemble, repair or transform the product without permission
– It may cause a fire or electric shock
| Do not use extension wires. otherwise, it may cause a fire or electric shock
– Do not connect wires or use extension cords, which may cause fire and electric shock.
| Do not install this product in damp places such as bathrooms
– It may cause a fire or electric shock
| Do not use unhealthy water
– May cause skin irritation and other problems

With Auto Open Cover Flip Remote Control

Note: Please read the following carefully before use

STOP
You can stop the “Hip cleaning’ “Female cleaning”, “braying” and other operation when operation
SPRAY/MASSAGE
Press this button when you are seated, rear washing will spray at the fixed position for 2 minutes and then stop spraying automatically. Press again during cleaning to start move cleaning.
BIDET/MASSAGE
Press this button when you are seated, lady washing will spray at the fixed position for 2 minutes and then stop spraying automatically. Press again during cleaning to start move cleaning.
DRYER
Press this button to start drying when you are seated. Warm air drying will stop automatically after 3 minutes.
FORWARD
Press this button during the “hip” or. “female” cleaning and adjust the nozzle position without the  use of the removable cleaning function.
CLEANING HEIGHTEN
It can increase or decrease the force of cleaning water pressure.
It can be set to weak, medium, strong, or strongest.
OPEN COVER
Press this button, the seat cover will open automatically, and then press it again, the seat cover will close automatically.
OPEN SEAT
Press this button, the seat opens automatically, and press again to close the seat automatically.
FLUSH
Press this button and will start flushing.
WATER
4 degrees can adjust the water temperature , the temperature can be set as, one degree : the environment temperature, second degree :34, °C Third degree :37,°C
Forth degree : about 40°C
SEAT
4 degrees can adjust the seat temperature the temperature can be set as, one degree : the environment temperature, second degree :34, °C Third degree :37,°C Forth degree : about 40.°C
WIND
4 degrees can adjust the wind temperature the temperature can be set as , one degree: the environment temperature, second degree: about 35,°C Third degree :about 45,°C Forth degree : about 55.°C
Remote control pairing
Switch the knob to the hip cleaning for about 3 seconds ,when you hear a sound , press any button of the remote ,then can pair the remote to the toilet.
BABY WASH
After the baby is seated then press the baby wash button ,it will start the hip cleaning automaticly , and the washing pressure will be adjust to the lowest level automaticly ,it will change to mobile cleaning when press one more time , and  auto close the baby washing when you press the ” stop ” button
AUTO
Nozzle extended and water out for nozzle washing
LIGHT
The night light can be turned on or off in the power-on state.TEISVAY UI 300
Smart Auto Lid Smart Bidet Toilet - Figure 1

Touch Screen Function (Optional)

Note: please read the following carefully before use
Left side temperature instructions

TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet - icon
19

Touch wind temperature
Four adjustable gear| Touch seating temperature
Four adjustable gear| Touch water temperature
Four adjustable gear

The instructions on memory function

User one setting :
Press the user 1 button for short time when turn on the toilet machchine
Press the user 1 button for long time about 3 seconds to store user 1 data

User two setting :
Press the user 2 button for short time when turn on the toilet machchine
Press the user 2 button for long time about 3 seconds to store user 2 data

Side knob instructions

Power on/off : long press the knob for more than 3 seconds
Hip cleaning : Turn the knob to the left
Female cleaning : Turn the knob to the right
Stop : Press the knob once
Toilet flushing : Press the knob once before seating
Warm air drying : Press the knob once when seating
Power failure flushing : connect the spare battery, press the knob for 3

seconds during power failure to start flushing.

Aromatherapy Function Instruction

Note: Please read the following carefully before use

TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet -
Function

Step one :
Open the adsorbed rear cover on the toilet top cover
put it on  the flat surface , and find the aromatherapy
piece in the box .| Step two :
Put into the original aromatherapy circle (Or you can buy your  favorite aromatherapy on online store )
TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet - Function
2
Step 3 :
Open the essencial oil , add 2-3 drops into the aromatherapy piece
( Kindly reminder that remember can not drop the essencial oil into the machine)| Step 4:
Installa the adsorbed rear cover into original position close the box  then can use

Installation of smart toilet

Note: Please read the following carefully before use
Reference diagram of water inlet and drainage positions
Note: the size only for reference , ( handmade , allowed 1-2 cm earror)
Waterproof, splash proof 10A socket with ground fault circuit breakerTEISVAY
UI 300 Smart Auto Lid Smart Bidet Toilet - diagram

List of materials

TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet -
material

Installation Method

TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet - Installation
1

1. Set the water value in the tap| 2. Put the flange ring on the buttom of the toilet bowl and
aim at the outlet
TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet - Installation
2
3. It can flush when power off after install the satandby battery| 4. Use the glass gule stick arround the toilet bowl
TEISVAY UI 300 Smart Auto Lid Smart Bidet Toilet - Installation
3
5. Inlet pipe connection angle valve| 6. Plug in the power and complete the installation

Description of other functions

Note: Please read the following carefully before use

Flushing by hand conduction
Press remote or intelligent control board for flushing , start flushing function (manual open cover)
Hand conduction open over and flip function
Press remote or intelligent control board for opening cover/flip , auto open/off seat and flip (auto open cover)
Radar automatic open cover function
When approaching the toilet , auto open cover , auto off seat and finish flushing when leaving (auto open cover)

Daily cleaning and maintenance

Note: During cleaning and maintenance, please be sure to unplug the power switch and power off

Smart toilet cleaning and maintenance methods
Please wipe it with a soft cloth dampened with water
– If the dirt is not removed in time, it will become difficult to clean, please wipe with water sometimes.
– Static electricity will absorb dust, resulting in the product black, dirtywater wipe can prevent the generation of static electricity.
– The ceramic body can be removed from the toilet seat to facilitate cleaning between the toilet seat and the ceramic body.

Cleaning and maintenance of spray head
If there is dirt in the nozzle. Please clean it with a small brush such as a toothbrush.

  • Do not stretch and bend the spray head.

Clean the dust on the power plug regularly
When cleaning, remove the power plug and wipe with a dry cleaning cloth.

  • Poor insulation may cause a fire.

Please be sure to observe the following
Please don’t sprinkle urine at the essence and spray.
Pull out the plug when it thunders.
Strictly forbid to directly flush with water.
Please do not wipe seat and cover with dry cloth or toilet paper.
Please do not open the seat ring or cover violently.
– May cause cracking or malfunction.

Please take antifreeze measures to prevent damage caused by freezing.

Please do not put heaters near this product.
– Discoloration or malfunction will occur

Common fault diagnosis

Note: If similar fault is found, please read the following solution or contact after sales

Fault phenomenon Fault analysis Fault handling
Product unavailable Check to see if the power/socket is loose Please check

the circuit
Whether there is leakage (the display light of leakage protection plug is not on)| Remove the power plug from the socket and replug it later.Press the reset switch of the leakage protection plug. If the elbow still cannot be operated. please unplug the power plug and entrust the repair.
No water with spray| Check if water is cut off| Pending resumption of water supply
Check that the Angle valve is closed| Open the Angle valve
Check if the inlet filter is blocked| Clean or replace the fitter
Check the inlet pipe for bends| Exclude the intake bend
Cleaning insufficient
ngidity| Check whether the cleaning pressure is at the lowest level| Refer to the instruction manual for regulating the water pressure
Check if the inlet filter is blocked| Clean or replace the fitter
Spray water disorderly| Abnormal operation| Unplug the plug for one minute and then switch it back on
water temperature
is not enough| Check that the water temperature is set low| Adjust the water temperature according to the instructions
Whether the hot and cold massage function is on| Turn off the hot and cold massage function according to the instructions
The washer
often drips water| Solenoid valve failure| Please get professional maintenance technicians
Misoperation of remote
control| Check the battery level of the remote control is it too low| Please replace the battery
Drying/seat temperature
too low/no heating| Check whether the temperature is set at low or normal temperature| Adjust the temperature according to the instruction
Whether to turn on the power saving function| Refer to the manual to choose to turn off the power saving function
Seat cover falling too fast| Failure of damping drop function| Please get professional maintenance technicians
The cleaning function
cannot be used normally| Is there any other hard material holding it under the seat| Remove the hard objects
Whether the body’s sensing area is covered| Adjust the body sensing area of the seat cover
Whether the power supply is restored during the power failure| Unplug the plug for one minute and then switch it back on
The skin completely cover the human body induction area of the seat| Sensor failure, please get professional maintenance technicians
Seat/cover cannot be
opened or dosed only for automatic flip machines| Failure of automatic damping function| 1.Disconnect the plug for one minute and switch it back on
2.The above treatment is invalid, please ask professional personnel for maintenance
Low water pressure
does not flush clean| Filter mist blocking| Clean the filter according to the instruction
Pipe bending| Observe whether the connection line bends and keep the water supply line smooth
No siphon flushing is not
clean when water
pressure is normal| Air escapes from the sewage outlet| Please get professional maintenance technicians
The S-bend is blocked| Please bu water
y pipe dredger in the market
for dredging
Flush is not clean when
water pressure normal| Flush valve failure| Ask professionals for maintenance

Due to the different printing time of the materials, the product specifications may be slightly changed.Please refer to the material object.

Product standard

Rated voltage Alternating voltage 110V±10%, 50HZ/60HZ
Rated power Water inlet temperature: 15°C Outlet water temperature: 40°C

Water discharge: 750m1/min Power: 1350W
Cleaning| Water outlet| Hip cleaning| About 700 ml/min
Female cleaning| About 700 ml/min
Outlet water temperature| Normal temperature, and 34°C/37°C/40°C(4 grades)
Water heating| Instant water heater
Heater power| Water inlet temperature: 15°C , Outlet water temperature: 40°C Water discharge: 750m1/min Power: 1350W
Seat heating| Seat temperature| Normal temperature, and 34°C/37°C/40°C(4 grades)
Heater power| 40W
Warm drying| Wind temperature| Normal temperature, and 35°C/45°C/55°C(4 grades)
Spray position| Adjustable Fore and Aft
Water temperature| 5-40°
Water Pressure ( With Water Tank )| The lowest pressure : 0.06 Mpa
the highest pressure : 0.75 Mpa ( static)
Water Pressure ( Without Water Tank )| 0.15-0.75 Mpa (static) is about 5L of water in 15 seconds

Please read carefully before using. The cautions listed here are related to safety and please follow.
This product is an electrical product. Please do not install it in a place where it is easy to be splashed by water or high humidity. When using in the bathroom, please install a vent to keep good air flow in the bathroom.
The socket for power distribution should be set as follows

  • The gearing position of electric outlet pleases to give examples 0.3 min the ground above, and leave bathtub as far as possible a little bit farer.
  • The back track of electric outlet pleases use a high feeling and rapid type electric leakage switch (the sum certainly responds the electric current 15 mA following) or use to insulate the transformer 1.5 KVA above, the 3 KVA is  following)carry on a protection.

Warning – Be sure to firmly connect ground wires
The power plug of this product is a three-phase plug (with ground wire).
There is a danger of electric shock when there is a fault or leakage of electricity.
If there is no ground plug in the socket, consult with the electrical installation company.
Do not use power supply other than AC 110V, please wiring according to relevant regulations.
The product connects a ground of line to carry on to connect a ground of processing, if has never carried on to connect a ground of processing, may arouses to get an electric shock.
Note: the grounding treatment mentioned here means that the grounding resistance is below 100Ω, and the grounding wires of the switchboard shall be copper wires with a diameter of more than 1.6mm.
While using in the bathroom please confirm the power plug have already used silica gel to carry on a waterproof processing.
Using the wrong power supply can easily cause fire

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals