Whynter ARC-1230WNH NEX Inverter Dual House Portable Air Conditioner User Manual

June 14, 2024
Whynter

Whynter ARC-1230WNH NEX Inverter Dual House Portable Air Conditioner

Product Information

Specifications

  • Model: ARC-1230WN/ARC-1230WNH
  • Modes: Auto/Cool/Fan/Dry (ARC-1230WN), Auto/Cool/Fan/Dry/Heat (ARC-1230WNH)
  • CEER | EER: 12.3 | 10.0 (ARC-1230WN), 12.3 | 10.8 (ARC-1230WNH)

Accessories

Accessory Qty
Hose-in-hose (Air intake hose & exhaust hose) 1 set
Air outlet adapter 1 piece
Exhaust Connector 1 piece
Window Slider A 1 piece
Window Slider B 1 piece
Foam Seal A (Adhesive) 2 pieces
Zip Tie (For ARC-1230WNH model only) 2 pieces
Foam Seal B (Adhesive) 2 pieces
Foam Seal C (Non-Adhesive) 1 piece
Security Bracket 1 set
Drain Hose Adaptor (For ARC-1230WNH model only) 1 piece
Power Cord Buckle (N/A for ARC-1230WNH model) 1 piece
Bolt 1 piece
Remote Control 1 set
Washable Filter (preinstalled) 1 piece
Window Slider A 1 piece
Window Slider B 1 piece

Product Usage Instructions

Window Kit Installation

Adjustable Window Slider Option:

  1. Measure the window opening where the window kit will be installed.
  2. Assemble as many sliders as necessary to fit the window. If the window opening is less than the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is necessary to attach the exhaust hose adapter.
  3. Use the window slider bolts to secure the window sliders at the correct length.

Hoses Connector Modules (For Sliding Window):
Assemble the exhaust adapter module for sliding windows using the exhaust connector screw as shown. The window slider is eccentric, so the exhaust adapter must be installed away from the wall.

  1. Rotate the exhaust hose gently backward.
  2. Pull out the exhaust hose away from the wall.

Hose-in-hose:

NOTE:
To ensure proper functioning, DO NOT overextend or bend the hose. Make sure that there is 20″ of clearance around the air outlet of the exhaust hose in order for the exhaust system to work properly. All illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. The actual shape shall prevail.

FAQs

  • Q: What do the symbols displayed on the unit mean?
    A: The symbols on the unit indicate important information. The “WARNING” symbol indicates that the appliance uses a flammable refrigerant, and there is a risk of fire if the refrigerant is leaked and exposed to an external ignition source. The “CAUTION” symbol indicates that the operation manual should be read carefully. The “CAUTION CAUTION” symbol indicates that service personnel should handle the equipment with reference to the installation manual. The “-” symbol indicates that information is available such as the operating manual or installation manual.

  • Q: What should I do before installing or operating the air conditioning unit?
    A: Before installing or operating the air conditioning unit, it is important to read the manual carefully. Make sure to save the manual for future reference.

Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.

DISPOSAL INFORMATION
Thank you for choosing Whynter. Please follow the instructions provided in this user manual to obtain the very best performance from your portable air conditioner. We trust that your Whynter portable air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference.

This symbol on the product or its packaging indicates that this appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment.

Further information about the recycling of this product can be obtained from your local municipal authority.

Supplier’s Declaration of Conformity
47 CFR § 2.1077 Compliance Information

  • Unique Identifier: RG51 F2(2)/EFU1 Responsible Party – U.S. Contact Information
  • Brand: Whynter
  • Company Name: Whynter LLC.
  • Address: 3320 E Birch Street, Brea CA 92821
  • Internet contact information: https://www.whynter.com.

FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Caution:
Risk of fire/flammable materials (Required for R32/R290 units only)

IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only):

SAFETY PRECAUTIONS

Read Safety Precautions Before Operation and Installation
To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instructions may cause death, harm or damage.

  • Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
  • Use only the included accessories and parts, and specified tools for the installation. Using nonstandard parts can cause water leakage, electrical shock, fire, and injury or property damage. Make sure that the outlet you are using is grounded and has the appropriate voltage.
  • The power cord is equipped with a three-prong grounding plug to protect against shock.
  • Voltage information can be found on the nameplate of the unit.
  • Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the unit), have a qualified electrician install the proper receptacle.
  • Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
  • The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
  • Do not modify the length of the power cord or use an extension cord to power the unit.
  • Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
  • Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
  • Ensure there is a minimum of 36″ clearance around the unit and is clear from any combustible items such as propane, fire extinguishers, fuel, etc.
  • The exhaust hose should always be used and should never be covered or blocked which can become a fire hazard.
  • The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpets or to roll over objects, as these could cause tipping.
  • Do not operate a unit that it has been dropped or damaged.
  • Do not place the portable air conditioner close to any other heat-generating appliances
  • Do not touch the unit with wet or damp hands or when barefoot.
  • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
  • In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
  • Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs.
  • All wiring must be performed strictly in accordance with the wiring diagram located inside the unit.
  • The unit’s circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as T 3.15A/250V, etc.
  • When the water drainage function is not in use, keep the upper and the lower drain plugs firmly plugged into the unit to prevent choking.

CAUTION

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Children must be supervised around the unit at all times.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  • Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
  • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
  • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
  • Do not run a cord under the carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Do not route the cord under furniture or appliances. Arrange the cord away from the traffic area and where it will not be tripped over.
  • Do not operate the unit with a damaged cord, plug, power fuse, or circuit breaker. Return to an authorized service facility for examination and/or repair.
  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Contact the manufacturer or authorized service technician for repair or maintenance information on this unit.
  • Contact the manufacturer or authorized installer for installation questions of this unit.
  • Do not cover or obstruct the inlet or outlet grilles.
  • Do not use this product for functions other than those described in this instruction manual.
  • Before cleaning, turn off the power and unplug the unit.
  • Disconnect the power if strange sounds, smells, or smoke come from it, and contact the manufacturer or authorized service technician for assistance.
  • Do not press the buttons on the control panel with anything other than your fingers.
  • Do not remove any fixed covers. Contact Whynter Customer Support if this unit is not working properly, or if it has been dropped or damaged.
  • Do not operate or stop the unit by inserting or pulling out the power cord plug.
  • Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapor such as alcohol, insecticides, petrol, etc. Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
  • Always contact Whynter Customer Support for replacement parts compatible with your unit. Hold the plug by the head of the power plug when taking it out.
  • Turn off the product when not in use.

WARNING

  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating
    gas appliance or an operating electric heater).

  • Do not pierce or burn the unit.

  • Be aware that the refrigerants may not contain an odor.

SAFETY COMPLIANCE

  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer.
  • Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  • Please follow the instructions carefully to handle, install, clear, and service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within the air conditioner. When maintaining or disposing of the air conditioner, the refrigerant (R32) shall be recovered properly and shall not discharge to air directly.
  • No open fire or device that may generate spark/arcing shall be around the air conditioner to avoid causing ignition of the flammable refrigerant used.
  • Please follow the instructions carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
  • Flammable refrigerant R32 is used in air conditioners. Please follow the instructions carefully to avoid any hazards. For specific information on the type of gas and the amount, please to the relevant label on the unit itself.

PREPARATION

All illustrations in the manual are for explanation purpose only. Your machine may be slightly different. The unit can be controlled by the unit control panel alone or with the remote controller.

DESIGN NOTICE
In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice.

EXHAUST HOSE INSTALLATION
The innovative hose in hose design delivers more than 2x faster and stronger cooling. The hoses and adapter must be installed or removed in accordance with the usage mode. For COOL mode & HEAT mode (only for ARC-1230WNH), the adapter and exhausts must be installed. For FAN or DRY mode, the adapter and exhaust hoses can optionally be removed.

CHOOSING THE RIGHT LOCATION
Your installation location should meet the following requirements:

  • Make sure that you install your unit on an even surface to minimize noise and vibration.
  • The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
  • The unit should be located at least 25cm (9.8″) from the nearest wall to ensure proper air conditioning. The horizontal louver blade should be at least 50cm (19. 7″) away from obstacles.
  • DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.

AMBIENT TEMPERATURE RANGE FOR UNIT OPERATION

INTRODUCTION/TECHNICAL DATA

INTRODUCTION TO INVERTER TECHNOLOGY
As pioneers in the air comfort space, we are introducing next-generation technology currently used only in high-efficiency ductless mini-split air conditioners. The Inverter technology be featured In our NEX line of portable air conditioners. By utilizing this much more efficient technology, Whynter’s Inverter variable-speed system allows the compressor to optimize efficiency and power consumption together, while maintaining a specified output

This allows for a much quieter operation and significantly reduced energy consumption. The Inverter technology system potentially reduces energy usage by more than 40″ while the new hose-in-hose design delivers more than double the cooling output. Below are the advantages of inverter technology:

  • At least 409′ – 50% cheaper to run as it consumes less power
  • Quicker to achieve the desired temperature
  • Quieter operation
  • No temperature fluct\lations
  • No voltage peaks from the compressor

HOSE-IN-HOSE COOLING SETUP
The Innovative two-hose one design and the sealed bottom structure ensure no heat leakage. This cooling setup extracts and exhausts air from the outdoor, so the Indoor space reaches an Independent and balanced cool air circulation. As a result, the entire room can be cooled down quickly and effectively.

WHAT SHOULD I LOOK FOR WHEN PURCHASING A PORTABLE AIR CONDITIONER?
The right air conditioner helps you cool a room efficiently. An undersized unit won’t cool adequately while one that’s too large will not remove enough humidity, leaving the air feeling damp. To find the proper air conditioner, determine the square footage of the room you want to cool by multiplying the room length by Its width. You also need to know the air conditioner’s BTI.J (British Thermal Unit) rating, which Indicates the amount of heat It can remove from a room. Why Is the cooling capacity lower on newer models than on older units? A higher number means more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are actually the same). Be sure to Nstze up” If your portable air conditioner will be placed In a very sunny room, In a kitchen, or In a room with high ceilings. After you’ve found the right cooling capacity for your room, you can look at other features.

WHY IS JHE COOLING CApAQJY LOWER ON NEWER MODELS JHAN OLDER MODELS?
Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure, which was changed just this year. Models manufactured before 2017 were tested under a different procedure and cooling capacity is measured differently than in previous models. So, while the BTUs may be lower, the actual cooling capacity of the air conditioners has not changed.

WHAT IS SACC?
SACC is the representative value of Seasonally Adjusted Cooling Capacity, in Btu/h, as determined in accordance with the DOE test procedure in Title 10 Code of Federal Regulations (CFR) 430, subpart B, appendix CC, and applicable sampling plans.

ACCESSORIES

Adjustable Window Slider Option

  1. Measure the window opening where the window kit will be installed.
  2. Assemble as many sliders as necessary to fit the window. If the window opening is less than the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is necessary to attach the exhaust hose adapter.
  3. Use the window slider bolts to secure the window sliders at the correct length.

Hoses Connector Modules (For Sliding Window)
Assemble the exhaust adapter module for sliding windows using the exhaust connector screw as shown. The window slider is eccentric so the exhaust adapter must be installed away from the wall.

Note:
For vertical installation, exhaust hose connector module B can be omitted.

  1. Rotate the exhaust hose gently backward.
  2. Pull out the exhaust hose away from the wall.

Hose-in-hose

NOTE:
To ensure proper functioning, DO NOT overextend or bend the hose. Make sure that there is 20″ of clearance around the air outlet of the exhaust hose in order for the exhaust system to work properly. All illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. The actual shape shall prevail.

WINDOW KIT INSTALLATION

NOTE:
Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods.

Hung Window or Sliding Window Installation

  1. Cut adhesive foam seals A and B to the correct lengths and attach them to the window frame as shown.
  2. Insert the window slider kit into the window opening and close the window the secure it in place.
  3. Cut the nonadhesive foam seal C to match the width or height of the window and insert it between the panes of glass as shown to prevent outside air from entering the window.
  4. If desired, install the security bracket with 2 screws as shown.
  5. For a hung window, attach the air outlet adapter to the exhaust hose and rotate it 90° to secure it in place. For a sliding window, attach the exhaust adapter to the exhaust hose.
  6. For a hung window, attach the air outlet adapter to the window slider kit. For a sliding window, attach the exhaust adapter to the window slider kit.

CONTROL PANEL

DISPLAY ICONS

  • Wireless feature (Wireless enabled models only)
    Illuminates to show the wireless connection is activated.

  • The timer on/ off indicator light
    Press and hold on to the TIMER button for 3 seconds to cancel the timing function.

  • Operation Mode Indicator Lights
    Illuminates to show the current mode of operation.

  • LED Display
    Shows the set temperature in °F or °C and the Auto-timer settings. While on FAN modes, it shows the room temperature.

  • Fan Speed Indicator Lights
    Illuminates to show the set fan speed.

  • Sleep Indicator Light
    Illuminates when Sleep Mode is activated.

  • Filter Indicator Light
    The LED will illuminate after 250 hours of operation. This feature is a reminder to clean the Air Filter for more efficient operation.

CONTROL BUTTONS

Swing/Wireless Mode

  • Auto-swing
    Press to start the auto-swing feature. When the operation is ON, press the SWING button to stop the louver at the desired angle.

  • Turn on the Wireless connection mode
    To turn on Wireless connection mode, press and hold the swing button for 3 seconds and the LED display will show “AP” for 3 seconds. Follow the instructions on the Wireless setup manual and the latest app version available for your phone operating system.

  • Turn off the Wireless connection mode
    Once the wireless connection mode is successful, press and hold the swing and down buttons for 3 seconds and the LED display will show “OF” for 3 seconds.

  • Connection Successful
    If the connection is successful within 8 minutes, the unit will exit wireless connection mode automatically and the wireless indicator will illuminate.

  • Connection Failed
    If the connection has failed within 8 minutes, the unit will exit Wireless connection mode automatically.
    NOTE: When you restart the wireless functions, it will take a period of time to connect to the network automatically. Always be sure your wireless connection is working properly and there is a valid internet connection for Wireless functionality to work.

  • Timer
    Press to program timer delayed switch ON or OFF function.

  • Modes
    Press to change modes. Controls the functions modes: AUTO, COOL, DRY, FAN, and HEAT*.

    • only for ARC-1230WNH
  • Up and Down buttons
    Adjusts set temperature 1°F | 1°c increments or timer hours (O – 24 hours).
    NOTE: This unit is capable of displaying a set temperature in Fahrenheit or Celsius. To convert from one to another, press and hold the Up and Down buttons for 3 seconds.

  • Fan
    Press to change the fan speed. Controls the 5 fan speeds and modes: Continuous, Auto, Low, Medium, and High.
    NOTE: In Auto and Dry mode, the fan speed control is disabled in Continuous Fan Mode. Press and hold to select continuous fan speed. The fan speed will keep on operating in a continuous speed based on the last fan speed setting.

  • Sleep Mode
    Press to activate Sleep mode. Press the SLEEP button again to stop the sleep operation.
    NOTE: This feature is not available in FAN or DRY mode.

  • Filter
    Press the SLEEP button for 3 seconds to initiate the filter feature.

  • Power
    Press to turn the air conditioner on and off.

ERROR CODES

  • El – Room temperature sensor error
    Unplug unit and restart it in 5 minutes

  • E2 – Evaporator sensor error
    Unplug unit and restart it in 5 minutes

  • E3 – Condenser sensor error
    Unplug the unit and restart it in 5 minutes

  • E4 – Display panel sensor error
    Unplug the unit and restart it in 5 minutes

  • Pl – Water reservoir full
    Drain water from the unit

OPERATION INSTRUCTIONS

BEFORE USING YOUR APPLIANCE

  • Remove the exterior and interior packing
  • Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation

SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF button on the remote control

COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE button until the COOL indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air. The temperature setting range of this air conditioner is from 60°F / l6°C to 86°F / 30°C. To set the temperature, press the or buttons. This air conditioner has an S”F temperature cushion which if the set temperature is within S”F of the ambient temperature, the unit runs on fan-only mode. This saves energy and prolongs the life of the compressor of the air conditioner. To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings.

DRY (DEHUMIDIFYING) ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature, and the fan speed is set to LOW. To activate this function mode, press the MODE button until the DRY indicator light is displayed. Please note that when switching function mode, there will be an approximately 3-minute transition time. In de- modifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be recirculated into the room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.

NOTE:
When using dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the warm air is exhausted to the outside, and cooling within the room may occur. Additionally, if the exhaust hose is not vented, the unit may require more frequent draining. Also, the air conditioner does not have a humidistat in which a specific humidity level can be set.

AUTOMATIC MODE
When you set the air conditioner in AUTO mode, it will automatically select cooling or fan-only operation depending on what temperature you have selected and the room temperature is close to the unit. The fan speed is automatically selected and cannot be changed. To operate the unit in Auto mode when the unit is on, press the MODE button until the AUTO indicator light comes on.

*HEAT MODE (only for ARC-1230WNH)**
This air conditioner operates on the heat pump principle, absorbing heat from the air outdoors and transferring that heat to the indoor unit. In this mode, the air conditioner heats the room. To activate this function mode, press the MODE button until the HEAT indicator display comes on. When the heating mode is set, the compressor will start in approximately 3-5 minutes. The heating temperature setting range of this air conditioner is from 60°F 86°F / l6°C 30°C. To set the temperature, press the UP and DOWN buttons. To set the fan speed, press the FAN button.

FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button until the FAN indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the FAN button. When using the only mode, venting the exhaust hose to the outside is optional.

TIMER (DELAYED SWITCH ON t OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled, and disabled.

SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set the desired time delay OFF hours by pressing the UP and DOWN buttons. The time increments are from 0.5 hours to up to 10 hours, followed by 1-hour increments of up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel the delayed switch-off function, turn off the air conditioner or adjust the time set ting to 0.0.

SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time delay ON hours by pressing the UP and DOWN buttons. The time increments are from 0.5 hours to up to 10 hours, followed by 1-hour increments up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch-on function, turn on the air conditioner or adjust the time setting to 0.0.

I SENSE FUNCTION
The remote control serves as a remote thermostat allowing for precise and comfortable temperature control. With this technology, an efficient temperature sensor is integrated into the remote control. To activate the I SENSE function, press the I SENSE button on the remote control. Once this function is activated, the remote control will send the temperature signal to the air conditioner every 3-minute interval until you press the I SENSE button again. The air conditioner will automatically cancel the I SENSE feature if it does not receive the signal during any 7-minute interval.

NOTE:
The i SENSE feature is not available in DRY and FAN mode. Shifting the operating mode or turning off the unit will cancel the Follow Me feature automatically. The remote control needs to be within 26 feet of the indoor unit for the I-SENSE mode to work appropriately.

SLEEP MODE
In this mode, the air conditioner gradually increases the set temperature in cooling mode, decreases the noise level, and conserves energy. In Economy and cooling mode, the set temperature is increased by 1 •ct 2°F in the first 30 minutes. The temperature wi II then increases by another 1 •ct 2°F after an additional 30 minutes. This new temperature will remain the same for 7 hours. To activate this function mode, press the SLEEP button until the SLEEP indicator light comes on.

NOTE: This feature is not available in FAN or DRY mode.

AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.

CONTROLLING THE AIRFLOW DIRECTION
The louvers can be controlled to Auto-swing or in a fixed direction. To control the airflow direction by Auto Swing, press the SWING button. To set the louvers in a fixed angle or direction, press the SWING button while on Auto Swing mode when the desired angle is chosen.

NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.

  • The compressor may make a pulsating or high-pitched sound
  • Water running from the evaporator to the water tank may make a splashing sound
  • Refrigerant flowing may make a gurgling sound
  • Fan sound may come from front and back air vents

COMPRESSOR LOCKOUT
This portable air conditioner is optimized to operate at an ambient temperature of 64°F -90°F. The compressor circuit has an automatic 3-minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.

REMOTE CONTROL

The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. The reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters/ 26 feet.

NOTE:

  • Other appliances in the same room controlled by remote control (1V, radio, stereo, etc.), may cause interferences
  • Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner
  • Remove the batteries if the remote control is not used for long periods

REPLACING TltE REMOTE BATTERIES
This remote control comes with two AAA batteries. Place the batteries in the remote control before use.

  1. Slide the back cover from the remote downward to expose the battery compartment.
  2. Insert the batteries, ensure to match the (+) and (-) symbols on the ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

Notes:

  • The air conditioner will not respond if curtains, doors, or other materials block the signal from the remote control to the unit.
  • Prevent any liquid from contact with the remote control. Do not expose the remote control to direct sunlight or heat.
  • If the Infrared signal receiver on the Indoor unit Is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
  • Do not mix old and new batteries or batteries of different types.
  • Do not leave the batteries in the remote control if it is not going to be used for more than two months.

CARE AND MAINTENANCE

SAFETY PRECAUTIONS

  • Always unplug the unit before cleaning or servicing.
  • DO NOT use flammable liquids or chemicals to clean the unit.
  • DO NOT wash the unit under running water. Doing so causes electrical danger.
  • DO NOT operate the portable air conditioner if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord. ContactWhynter Customer Support for more information.

WATER DRAINAGE
When the internal drain pan becomes full the appliance will beep 8 times and the digital display will show error code P1. The air conditioning or dehumidifying action will stop but the fan may continue to operate. Ensure that the appliance is turned off and unplugged and that it is close to a floor drain before setting up any drain option.

  • A. Drain Plug
    Remove the drain plug and allow the water to completely drain. Replace the bottom drain plug, pressing firmly to ensure a tight fit and no leaks.

  • B. Continuous Gravity Drain
    During dry mode, install a continuous drain option so that the appliance will automatically drain collected water. Remove the upper drain plug and attach the drain hose that was provided with the appliance. Place the open end of the drain hose over the receptacle that the appliance will drain Into; this could be a basement floor drain, a sink or similar. Ensure that there are no kinks or bends in the drain hose and that it goes straight down toward the floor. The continuous drain is activated by gravity only. If the hose is not positioned directly downwards, water will not drain correctly.

  • C. Heat pump drainage (for ARC-1230WNH only)
    This unit has a condensate pump feature that can pump out (and up) water through the included drain hose for continuous water removal during HEAT Mode. Remove the heat pump drain plug from the back of the unit and install the drain hose. Place the open end of the hose to a drain area.

    • NOTE: The condensate pump will only engage during Heat mode and will not work in any other modes. A pump drain hose is required to be installed when using the portable air conditioner in Heat Mode.
    • NOTE: To reduce pump drain noise, make sure to attach the drain hose adaptor to the open end of the drain hose. To secure the adaptor in place, use the provided zip tie.

UNIT CLEANING

CLEANING

  • Unplug the appliance before cleaning or servicing.
  • Clean the cabinet with a lukewarm damp cloth and neutral detergent. Dry the cabinet with a lint-free dry cloth.
  • Do not use gasoline, paint thinner, or other chemicals to clean the appliance.
  • Do not wash the appliance directly under a tap or using a hose. It may cause electrical damage.

AIR FILTERS
The air filter should be cleaned every two weeks to ensure efficient performance. In households with animals, the air filters may need to be cleaned more often and the external grills may need to be wiped to prevent blocked air flow.

To access the filter:

  1. Switch off the air conditioner.
  2. Hold the exhaust hose, push it backward slightly, and then lift it up.
  3. Remove the filter from the unit.
  4. Use a vacuum cleaner or tap lightly to remove loose dust and dirt.
  5. Rinse the filter thoroughly under warm running water (no hotter than 100· F.)
  6. Dry thoroughly before re-inserting the filter.

LONG TERM STORAGE

  1. Drain all water from the appliance.
  2. Run the appliance on Fan mode for half a day in a warm room to dry the inside of the appliance and prevent mold formation.
  3. Turn off the appliance and unplug it, wrap the cord, and bundle it with tape.
  4. Remove the batteries from the remote control.
  5. Clean the air filters and reinstall them.
  6. Store the appliance in a cool, dark place. Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of the appliance.

DISPOSAL
This appliance should not be treated as regular household waste. Check for local regulatory compliance regarding the approved and safe disposal of this appliance.

ERROR CODES
P1-water tray is full attach the drain hose and drain excess water

If any other error code appears on the display, unplug the air conditioner and allow it to sit undisturbed for 5 minutes. If the error code persists when the unit is plugged back in, please contact Whynter Customer Support.

TROUBLESHOOTING

Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department.

WARRANTY

ONE-YEAR LIMITED PARTS WARRANTY THREE YEAR WARRANTY ON THE COMPRESSOR
This WHYNTER product is warranted to the original owner, purchased from an authorized Whynter dealer within the 48 U.S. continental states, for one year from the original purchase date against defects in material and workmanship under normal residential usage. Should your WHYNTER product prove defective within one year from the date of purchase, contact Whynter’s Customer Support team with the serial number and proof of purchase to make a warranty claim. A Return Authorization number must be issued before returning any parts or products. Parts or products received without a Whynter-issued Return Authorization number will be refused. Under this warranty, Whynter will repair or replace any parts found defective with new or remanufactured parts or exchange the defective product with a new, refurbished, or remanufactured product at our discretion. All defective products and parts covered by this warranty will be repaired or replaced on a mail-in basis to Whynter’s Service Center. This warranty is not transferable. After the expiration ofthe warranty, the cost of labor and parts will be the responsibility of the original owner.

After two months to one year, the customer will be responsible for the return freight cost to Whynter’s Service Center. Please package the product carefully in its original packaging to avoid damage in transit. Whynter is not responsible for damage resulting from shipper mishandling or improper packaging. Please retain the original box and packaging materials.

THIS WARRANTY DOES NOT COVER:

  • Acts of God, such as fire, flood, hurricanes, earthquakes, and tornadoes.
  • Improper power supply such as power surge, low voltage, defective household wiring, or inadequate fuses.
  • Use in commercial or industrial applications.
  • Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material or workmanship.
  • Damage caused by consumer misuse, tampering, lack of maintenance, or failure to follow the care and special handling provisions in the instructions.
  • Damage to the finish of the case, or other appearance parts caused by wear.
  • Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
  • Removal, Replacement Packaging, Freight, and Insurance costs for the warranty service.
  • Products sold AS IS or from an unauthorized reseller.
  • Products that have had their serial numbers removed or defaced.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE ExauSION OR LIMITATION OF INCIDENTAL OR CONSE QUENT/AL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXaUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

To obtain service or information, contact
Whynter LLC via email at support@whynter.com or call 866 WHYNTER.

Product contents and specifications may change without notice.
Copyright© 2023 WWW.WHYNTER.COM.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Whynter User Manuals

Related Manuals