Honeywell N1097A19 ARC 13.56 MHz Upgradable Readers Instruction Manual
- June 14, 2024
- Honeywell
Table of Contents
- Product references
- Connection
- Smart mounting plate dimensions
- Mounting
- Bus architecture (RS485)
- Power supply characteristics
- Recommended cables
- Anti-tearing
- Bell
- Read-only reader configuration
- Powering-up the readers
- Precautions for the biometric sensor and the keypad
- Precautions for installation
- Declaration of compliance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ARC 13.56 MHz
Upgradable readers
Installation instructions
Product references
ARC-X
A: Standard
B: Keypad
C: Touch Screen
D: Standard + Biometrics
E: Keypad + Biometrics
X:
F: Touch Screen + Biometrics
I/IM: Standard + 125 kHz module
J/JM: Keypad + 125 kHz module
K/KM: Touch Screen + 125 kHz module
AQ: Standard + QR Code module
BQ: Keypad + QR Code module
CQ: Touch Screen + QR Code module
Download the complete installation instructions
Connection
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
J4 | Type |
---|---|
Wiegand | Clock & Data |
1 | 0 Vdc |
2 | +Vcc (+7 Vdc / +28 Vdc) |
3 | DO |
4 | D1 |
5 | Clock |
6 | NC |
7 | NC |
8 | Led 1 |
9 | Led 2 |
10 | Buzzer / Timbre |
Smart mounting plate dimensions
Version 1
Version2
General tolerance following ISO NFT 58-000 standard
Mounting
- Pass the cables through the hole in the base.
- Screw the base in its final location.
- Connect the reader.
- Test the readings and communication.
- Place the reader on the base (clip the top part and then pivot it down).
- Lock the reader with the two screws provided using the specific tool.
Bus architecture (RS485)
RT: 120 Ω end-of-line resistor supplied.
From version 17 of the electronic board, the readers are fitted directly with
pull-up / pull-down resistors on the electronic board.
Earlier versions require the wiring of resistors R1 and R2 (1.5 kΩ resistors
supplied) to use the extended features of the RS485 Bus: FAIL-SAFE (see
RS485-AN-960).
Power supply characteristics
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply:
Max. consumption at 12 Vdc:
Range: +7 Vdc to +28 Vdc
Typical: 12 Vdc
ARC-A/PH5: 130 mA
ARC-F/PH5: 350 mA
ARC-K/BF5: 230 mA| ARC-B/PH5: 160 mA
ARC-I/BF5: 160 mA
ARC-KM/BF5: 240 mA| ARC-C/PH5: 200 mA
ARC-IM/BF5: 170 mA
ARC-AQ/PH5: 260 mA| ARC-D/PH5: 280 mA
ARC-J/BF5: 190 mA
ARC-BQ/PH5: 290 mA| ARC-E/PH5: 310 mA
ARC-JM/BF5: 200 mA
ARC-CQ/PH5: 330 mA
---|---|---|---|---
Recommended cables
RS485: Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft
at 9600 baud
RS232: Max. length 49.2 ft
Wiegand / Clock & Data: Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 – 98 ft max / 4 wires AWG24 – 197 ft max / 6 wires AWG24 – 328
ft max
2 wires AWG20 – 164 ft max / 4 wires AWG20 – 328 ft max
Anti-tearing
Tearing is detected by an accelerometer.
Caution: switch on the reader when it is in its final position to initialize
the accelerometer in the correct position.
Bell
Touch screen read-only readers: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read-only reader configuration
R and S readers are configurable with SCB RFID configuration card.
OSDP™ readers are configurable with OCB RFID configuration card or with
FileTransfer command.
- If the SCB/OCB is compatible with the reader’s firmware, the LED lights green and the buzzer beeps five times.
- If the SCB/OCB is not compatible with the reader’s firmware, the LED lights red and the buzzer is activated for 1 s.
- If the SCB/OCB key is different from the reader’s key: no reaction.
Caution: set your reader with your own company key.
Powering-up the readers
On power-up, the reader enters an initialization phase:
-
Activation of the white LED and buzzer for 100 ms.
For read-only & OSDP ™ readers: -
Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
-
For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
-
Activation of the default LED (read-only: flashes blue, OSDP™ : off; if no customer specific configuration).
-
For the ARC screen with an activated keypad, the default mode is: display the picture on standby and activate the keyboard by pressing the screen.
Precautions for the biometric sensor and the keypad
- For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
- The keypad is sensitive. Take off your gloves to enter your code.
Precautions for installation
- The supply voltage at the reader’s connector should be between +7 Vdc and +28 Vdc.
- As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference depending on their radiation level and the proximity of the reader.
- Recommended distance between two readers: parallel plane: 11.81 in – same plane: 15.75 in – perpendicular plane: 9.8 in.
- Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
- If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
- Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
- By design, the reader can be installed indoors and outdoors.
- BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
- Operating temperature:
Temperature| -22 °F to 158 °F
-30°C to +70°C| -22 °F to 140 °F
-30°C to +60°C| -4 °F to 158 °F
-20°C to +70°C| -4 °F to 140 °F
-20°C to +60°C| 14 °F to 122 °F
-10°C to +50°C
---|---|---|---|---|---
Readers| A, B, IM, JM| AQ, BQ| C, I, J, K, KM| CQ| D, E, F
Declaration of compliance
Honeywell declares that the ARC-X reader is compliant to the essential
requirements of the Directives RED 2014/53/EU, RoHS 2011/65/EU and Delegated
directive.
A copy of our declaration is available on request.
This device complies with part 15 of the FCC Rules and with Industry Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation
NOTE: The grantee is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. Such modifications
could void the user’s authority to operate the equipment. This device complies
with the safety requirements for RF exposure in accordance with RSS-102 issue
5 for conditions of use and with §1.1307(b), 2.1091 and 2.1093 of the FCC
rules Title 47 CFR Ch. I.
The maximum magnetic field level of the device is:
- 12 dBµA/m (at 10 meters) for 13.56 MHz frequency.
- 25 dBµA/m (at 3 meters) for 125 kHz frequency (ARC-I, ARC-J and ARC-K).
- 9 dBµA/m (at 10 meters) for 125 kHz frequency (ARC-IM, ARC-JM and ARC-KM).
© Honeywell | Commercial Security | 715 Peachtree St NE FL4 | Atlanta, GA
30308-2179- NI1097A19 – Page 2 sur 4 – Ed. 09/12/2022
Honeywell reserves the right to make change without notice, for the purpose of
product improvement.
Read User Manual Online (PDF format)