Product description:
This equipment is a multi-functional cleaning equipment for cleaning air conditioners, range hoods, refrigerators, washing machines and other household appliances. The equipment adopts the working principle of instant high temperature and high pressure, which realizes the disassembly and cleaning of the range hood and air conditioner surface.
Product parameters:
Voltage | 220V 50Hz | Power | 3000W |
---|---|---|---|
Product model | STQX-02A | Steam temperature | ≥100°C (212°F) |
Steam pressure | ≥3 KGF/CM2 | Power cord length: | 1.8 m |
Power cord length | 1.8m | Steam pipe length | 2.5m |
Size | 430312292mm | Weight | 3.7 kg |
Accessories installation:
- Install the nozzle
- Done
- Use with plastic brush
- Use with copper brush
- Use with large plastic brush
- Install the stainless steel elbow
- Done
- Use with plastic brush
- Use with copper brush
- Use with big plastic brush
- Put the inlet hose into the bucket
- Connect the power supply
- Turn on the steam cleaner
- Adjusting wet and dry steam
- Press the handle of the spray gun, wait for 15s, and spray steam
- Start working
Precautions:
- Liquids or vapors should not be directed towards people or animals, and should not be directed towards devices containing electrical components, such as the interior of an oven.
- The power plug needs to be unplugged after use and maintenance of the steam cleaner
Packing list:
- Steam cleaner host *1
- 1m inlet pipe *1
- Flashlight (without battery)1| 4) Spray gun1
- Water tank*1
- Stainless steel elbow 1| 7) Large plastic brush1
- Plastic brush*2
- Copper brush*2
---|---|---
Common problem:
Problem | Cause of issue | Solution |
---|---|---|
The machine over heats or emits smoke | ① The equipment does not absorb water |
② The equipment does not absorb enough water
③ The insulation cotton of the roasting equipment causes| ①② Solution:
Stop the machine for 20 minutes and wait for the machine to cool before using
it to ensure that the equipment absorbs water and the dry humidity is adjusted
to the maximum.
③ Note: This phenomenon will only appear when it is just used, and after
three or four times of use, the phenomenon of smoking will not appear again.
Main uni switch ligh does not ligh up afte plugging in| ① The socket is loose
or faulty
② The problem of the machine switch| ① Solution: Check whether the socket
is powered on and whether it carries more than 2500W of power.
② Solution: the switch needs to be replaced
Lengt hened elbow leaks| The rubber ring is damaged| Solution: Put
another rubber ring or replace it with a new rubber ring and tighten it.
Too much water in the steam| Excessive water content is a normal phenomenon|
Solution: If dry steam is required, you can adjust the wet and dry
adjustment knob to the maximum.
Low steam temperature| The temperature out of the nozzle is the highest, which
can reach more
than 100 ℃. With the increase of the spray distance, the temperature
will gradually decrease.| Note: Since the spray is steam, the temperature
will drop rapidly in a short time. If you need to achieve the best cleaning
effect, please keep the distance between the nozzle and the stain within 3cm.
Does not produce steam| No steam due to scale blockage| Solution: It is
necessary to remove the scale inside the machine, and use a descaling agent or
citric acid to inhale the same as when the steam
engine is working, and it takes three to five minutes.
Automatic shutdown or small steam output| Shutdown or small steam output due
to scale blockage| Solution: Twist the steam outlet pipe to see if the
main engine can emit steam, and clean the scale on the inner wall of the main
steam outlet
The water pump does not work The performance is as follows: the switch
indicator light is normal, but the sound of pumping water cannot be heard,
and there is no water flow in the water inlet pipe.| ① The terminal wire
connected to the water pump falls off
② The scale is not cleaned regularly, causing the evaporator to be blocked.
Solution: Try to remove the scale first, if the machine still can’t work,
you need to replace the evaporator.
③The water pump is broken| ① Solution: disassemble the machine and re-fix
the terminal wire
② Solution: Try to remove the scale first, if the machine still can’t
work, you need to replace the evaporator.
③ Solution: replace the water pump.
Machine maintenance:
- After accumulative use for 10 hours, add water with citric acid or descaling agent, let the machine inhale the water and work for a few minutes to remove the internal scale. (If the water quality is poor, the scale needs to be cleaned regularly)
- This equipment cannot inhale water containing detergents to prevent corrosion or blockage of the machine, and shorten the use time.
- The device should be placed at room temperature to avoid freezing of the residual moisture inside the machine and blockage caused by placing it in a place where the temperature is too low.
Warranty:
We provide a one-year warranty, if there are any problems during use, please contact us in time, we will do our best to provide you with after-sales service.