Separett 1271 Waterless Urine Diverting Toilet
Product Information
The Separett Tiny with urine tube art.no. 1271 (12356-01) is a toilet designed for use in both cold and warm spaces. The toilet comes with a 90-degree connection and a urine bowl extension, and is designed for direct connection with 50mm pipes. The toilet also includes a ventilation pipe, a pipe cap with insect net, a ventilation cowl, a fan filter, a urine hose, and a straight and 90-degree joint for 32mm pipes. The toilet is powered by a 12V battery and comes with a power adapter. The package also includes compostable wastebags, an installation template, and sample drain cleaner and absorb pad. Before installation, it is important to ensure that the location for wall penetration allows for a hole to be made and that the piping meets construction regulations. The enclosed installation template shows possible installation options for urine drains and ventilation pipes through the wall behind the toilet or through the floor. These options enable an installation without visible pipes.
Product Usage Instructions
- Place the Separett Tiny toilet on the floor against the wall. For extra stability, attach it to the floor, wall, or both.
- Use the enclosed installation template to make holes for the urine drain and ventilation pipe.
- Install the included ventilation pipe. For optimal function, it is recommended to use Separett’s own installation kit that has pipes and angles in the correct dimensions.
- Attach the included urine hose to the toilet.
- Install either the ventilation pipe cap or ventilation cowl.
- Connect the toilet to the ventilation pipe and urine tube.
- Power the toilet using the included 12V battery cable and power adapter.
- Fix the toilet to the wall and/or floor.
- Install the fixed fan filter.
- Place the basket in the urine drain.
Note that when connecting the toilet to 1.5 inch pipes, it is important to ensure as short and simple a piping as possible, as the inner diameter of these pipes is smaller than the pipes in the Separett ventilation kit, hence the airflow restrictions. For these installations, a maximum of 4 meters of pipe and 2 90-degree bends is recommended.
WARNING!
Before making holes in walls or floors. Ensure that the location for wall
penetration allows for a hole to be made and that the piping meets
construction regulations. Keep in mind that the wall may conceal, for example:
electrical wiring, piping, waterproofing, load-bearing construction.
IMPORTANT! Always consult your local environmental office to find out
what rules apply in your municipality. Always follow local regulations. Please
view our installation video at www.separett.com
To make sure the toilet stays odor free, the fan in the toilet should always
be running for it to ventilate and receive fresh air to ventilate out. To
achieve this, the following is required:
- No other fan/ventilation system may affect the same room.
- Ensure that fresh air from the outside enters the room. The air entry point should be as close to the toilet as possible.
Useful tools
Included with the product
Installation steps
Please read more under each heading
- Toilet placement
- Make holes according to the installation template
- Install ventilation pipe
- Install urine hose
- Install ventilation pipe cap or ventilation cowl
- Power supply for toilet
- Connect the toilet to the ventilation pipe and urine tube
- Fix the toilet to the wall and/or floor
- Install fixed fan filter
- Place basket in the urine drain
Toilet placement
Separett Tiny has no requirements for room temperature and works in both cold
and warm spaces. The only requirements are that you must be able to lead the
urine away and fit a ventilation pipe.
The toilet is made to be placed on the floor against the wall, and for extra
stability it should be attached either to the floor, wall or both.
Make holes according to installation template
The enclosed installation template shows possible installation options for
urine drains and ventilation pipes through the wall behind the toilet or
through the floor. These options enable an installation without visible pipes.
Install ventilation pipe
The toilet is designed for 50 mm pipes (outer diameter). For optimal function
it is recommended that you use Separett’s own installation kit that has pipes
and angles in the correct dimensions. Separett Tiny can be installed with up
to 5 meters of ventilation piping and 2 90-degree bends. Ventilated air can go
through a wall, floor or roof, for example, up into an attic and out through a
suitable side of the house. If there is already a ventilation pipe present
from a previous toilet installation, the toilet may be connected to that duct,
provided that it is not smaller than 50 mm and that it meets the piping
requirements. Should you need longer piping that exceeds the recommendations
above, you may install an extra fan (art. no.: 13008) The toilet comes with a
coupling for connecting the included 40 cm-long 50 mm pipe to a 1.5 inch pipe
(schedule 40). For more information on this, please read section X.
X. When connecting the toilet to 1.5 inch pipes
Ensure as short and simple a piping as possible, as the inner diameter of
these pipes is smaller than the pipes in the Separett ventilation kit, hence
the airflow restrictions. For these installations, a maximum of 4 meters of
pipe and 2 90-degree bend is recommended. This toilet is designed for direct
connection with 50 mm pipes. A coupling to connect the toilet to a 1.5 inch
pipe (schedule 40) is also included. The included 50 mm pipe is to be
connected to the toilet or to the supplied 90-degree bend. The 50 mm pipe
should be cut to a suitable length. Use a coupling to continue the
installation with 1.5 inch pipes (schedule 40). 1.5 inch pipes (schedule 40)
have a smaller inner diameter and when using these pipes, as short and simple
installation as possible is desirable to ensure high functionality. The total
length of the pipes must be less than 4 meters and a maximum of 2 x 90-degree
bends is recommended.
Installation without visible pipes
- The included 90-degree bend is used to lay pipes backwards or to the side. The bend is placed as shown below and turned in the rearward direction. The bend can be difficult to get in place. Vaseline or a similar product may be used to facilitate the assembly.
- The supplied ventilation pipe is then connected to the 90-degree bend. The pipe is 40 cm (15,7”) long, which generally is enough to reach through an outer wall. If additional pipes are needed to direct the air out of the house, the Separett ventilation kit (art. no. 1344) is recommended for Tiny. It includes 4 meters of piping and bends to ensure a simple extended installation. These can also be used to extend the piping onto the facade of the house. Please note that as short an installation as possible is recommended to guarantee full function throughout the year.
- If the installation is to go through the floor, the pipe should be connected directly to the toilet, as shown below
- The picture below shows what a connection to Tiny can look like.
Alternative installation – visible pipes
- In cases where installation with hidden pipes is not possible, the ventilation duct is guided to the right or left by turning the 90-degree bend according to the pictures below. The piping must then be carried out in accordance with the recommendations for the installation of ventilation pipes. If additional pipes are needed to direct the air out of the house, the Separett ventilation kit (art. no. 1344) is recommended for Tiny. It includes 4 meters (13 ft) of piping and bends to ensure a simple extended installation. These can also be used to extend the piping onto the facade of the house. Please note that as short an installation as possible is recommended to guarantee full function throughout the year
Install urine hose
The toilet is delivered with a 2-meter (6,6 ft) urine hose. To connect this to the toilet, use the included straight joint or the 90-degree joint. Like the installation of the ventilation pipes, it is possible to connect the urine tube so that no pipe is visible where the toilet is installed. This is achieved by angling the 90-degree connection downwards or using the straight connection, as shown in the pictures below.
Recommendations for installation of urine hose
As with the ventilation duct, Tiny provides the option of installing the urine
hose without any visible pipes/tubes in the bathroom. Below are a few tips
that should be followed to maintain a well-functioning urine outlet over time
and all year round.
-
If you are going to go through an insulated wall or a wall with an air gap between the inner and outer wall, you must use a pipe for the penetration, or lead the hose through a pipe. Pipes are used to reduce the risk of pests causing damage to the tube.
-
If you are going to run the urine a longer distance than the 2 meters (6,6 ft) of the supplied hose, you should switch to a pipe after the 2 meters (6,6 ft). Since urine contains minerals that can accumulate in pipes/hoses, we recommend that the subsequent pipe have a diameter of at least 40 mm to avoid blockages.
-
Make sure that you always have a downward inclination of at least 2 degrees (2 cm per meter or 0,8 inch per 40 inch) throughout the piping, also make sure that there are no air pockets created by bends in the hose.
-
If the toilet is to be used in winter, outdoor pipes must have a diameter of at least 40 mm (1,6”).
If the toilet is to be used in winter, we recommend that you insulate outdoor pipes with pipe insulation.
This insulation can be bought in most DIY stores. -
An important rule for longer installations (over 2 meters (6,6ft)) is that the sooner you switch to pipes with a larger diameter, the lower the risk of blockages in the pipes.
-
Do not place pipe joints near electrical appliances or wall sockets. This is to prevent liquid from coming into contact with electricity in the event of a leak.
Installation without visible urine hose
For installation without visible pipes, the 90-degree bend is used to guide
the urine downwards or the straight joint to go backwards as shown in the
pictures below. Use the enclosed installation template to make holes in the
wall or floor in the correct positions
Installation with visible urine hose
- In cases where installation without visible pipes is not possible, a 90 degree bend is used to install the urine hose to the side (right or left) according to the pictures below.
- If the urine hose is to be laid sideways and the toilet is to be installed against the wall, the urine hose must be led through the side of the toilet, which requires a hole to be made in the plastic. For optimal results, use the same drill you would use for making holes in the wall. The toilet has marks on either side to show where the hole should be made, see pictures below. If you find it difficult to drill from the inside, use a smaller drill to make a small hole in the center, and then continue to drill from the outside. Use a knife or sandpaper to get a good border. If the urine hose is to be led further within the room, use the supplied Wall mount for urine hose. Make sure that the urine hose has a downward inclination all the way and that you have read through the recommendations for installing the urine hose
Installation of pipe cap or ventilation cowl
- It is important to ensure that the end of the ventilation pipe is protected from rain and snow, and prevents insects from entering the toilet. To achieve this, the toilet comes with a pipe cap that is equipped with an integrated insect net. This pipe cap should be used when the pipe end is horizontal and must be mounted with the screen upwards to ensure protection from rain and snow. The pipe cap fits both 50 mm and 1.5 inch pipes. 50 mm pipes go half way in and 1.5 inch pipes go all the way in. See picture below.
- The pipe cap can be fixed to the pipe through the visible screw markings
- When the pipe end is vertical, the supplied ventilation cowl is to be used together with a pipe cap to ensure that rain and snow do not enter the pipe.
- Pipe cap and ventilation cowl are mounted together with the two supplied screws as shown below.
The assembled parts are then mounted as pipe ends in the same way as shown in previous sections. It is also possible to use the ventilation cowl at a horizontal pipe end in more demanding conditions to ensure better protection against weather and wind.
Power supply for toilet
- If the toilet is to be mounted against a wall, a power cord must be connected to the toilet before it is mounted. After wall mounting, the connection is not accessible.
- The toilet must be connected to a power source. The toilet comes with a power adapter for 110–240 V and a 12 V battery cable. Regardless of the power source, the chord must be connected to the back of the toilet, at the marked input in the picture above. Make sure that the plug is properly connected. Verify that the toilet is receiving power by checking that air is exiting the ventilation outlet.
Connect the toilet to the ventilation pipe and urine tube
Toilet mounting
IMPORTANT! Connect the power cord to the toilet before mounting it. After
mounting, you will not have access to the back of the toilet where the cable
is to be connected.
Tiny is designed to be fixed to the floor or to the wall. For maximum
stability, both options can be combined.
-
Floor
To attach the toilet to the floor, use the supplied screw or other screw suitable for the purpose. There are two intended screw holes in the bottom of the toilet, the plastic in the middle of the hole is removed with a suitable tool. -
Wall
Use the following holes to mount the toilet to the wall
Install the fixed fan filter
The toilet is continuously ventilated to ensure an odor-free bathroom as well
as drying out waste. To protect the fan from dirt and dust resulting from use,
there is a filter in the air duct. This filter is not pre-installed but must
be installed on site as shown below. The filter should be cleaned regularly to
maintain its proper functioning.
To install the yellow fan filter in the toilet, follow the steps
below:
Place basket in the urine drain
Place the supplied basket in the urine drain. The net ensures that no large
objects enter the urine outlet. The basket is designed to perfectly fit a
Separett Bio Drain Cleaner.www.separett.com