Separett 11791-02 Basic Incinerating Toilet Instruction Manual
- June 14, 2024
- Separett
Table of Contents
Separett 11791-02 Basic Incinerating Toilet
Product Information
- Specifications:
- Product Name: Incinerating Toilet
- Model Number: 11977-06
- Manufacturer: Separett AB
Product Usage Instructions
- Installation:
- Ensure that the toilet is placed on a flat surface without any carpet underneath or in front of it.
- The ventilation pipes should be installed straight out and straight up behind the toilet. Do not install the pipes diagonally.
- If installing the toilet indoors, attach the condensation hose to drain the condensate water. Note that if installed outdoors, there is a risk of freezing during winter.
- Place the gaskets on the connection at the back of the toilet to ensure a tight fit between the toilet and the vent tube, preventing air and odor from escaping into the surrounding space.
- To prevent the outgoing air from flowing back into the space where the toilet is placed, ensure that the air intake (fresh air valve) and the vent outlet (vent cowl) are not placed too close together.
- The fresh air valve may only be placed on an exterior wall. Placement in the floor or ceiling is not approved.
- Follow any additional instructions provided by the manufacturer for specific installation options.
- Usage:
- Follow these guidelines for proper usage of the incinerating toilet:
- Ensure that there is a minimum of 100 mm space between the toilet and the wall.
- The maximum height from the floor to the top of the toilet should be 500 mm.
- Observe any alternative installation options provided by the manufacturer, labeled as A, B, C, or D.
- FAQ
- Q: Can I install the condensation hose when installing the toilet outdoors?
- A: No, it is not recommended to install the condensation hose outdoors as there is a risk of freezing during winter.
- Q: Can I install the ventilation pipes diagonally?
- A: No, the ventilation pipes should be installed straight out and straight up behind the toilet. Diagonal installation is not allowed.
- Q: Where should I place the fresh air valve?
- A: The fresh air valve should only be placed on an exterior wall. Placement in the floor or ceiling is not approved.
- Q: What is the minimum space required between the toilet and the wall?
- A: There should be a minimum of 100 mm space between the toilet and the wall.
- Q: What is the maximum height from the floor to the top of the toilet?
- A: The maximum height from the floor to the top of the toilet should be 500 mm.
TOOLS REQUIRED
Installation – This is included
- 90° bend
- Condensation hose
- Connection pipe 70 mm
- Ventilation cowl
- Drilling template
The condensation hose is only installed when installing indoors to drain condensate water. When mounting on installation outdoors there is a risk that the condensate water in the hose will freeze during winter.
IMPORTANT INSTRUCTION
IMPORTANT!
-
Separett Basic must be installed correctly both in order for it to function, and for the warranty to apply. There are regulations both indoors and outdoors for the installation. Follow the instructions carefully.
-
Separett Basic needs regular service to function properly. You will get a message on the display when it is time to service the toilet. Contact your nearest service center.
-
Separett Basic must be used correctly to function properly. Only bags like the ones you get with the toilet should always be used each time you use the toilet and only urine, sold waste and toilet paper may be incinerated. Always push the incineration button after you have used the toilet.
-
Follow the instructions for using the toilet carefully.
-
There must not be any other ventilation system, such as a fan or similar, in the space where the toilet is placed.
-
The incinerating toilet must be placed on a flat surface without carpet under or in front of the toilet.
-
The ventilation pipes may only be installed straight out and straight up behind the toilet.
-
It is not allowed to install the pipes diagonally.
-
Only Ø110 mm vent. pipes made of plastic, 1pcs 90° long bend and 2pcs 45° connectors (to go around the roof ridge) may be used in the installation.
-
In order for the airflow to be optimal, the 90° long bend and ventilation cowl included must be installed.
-
The windshield is mounted by passing it about 4cm above the ventilation tube until the edge on the inside receives. In the use of another long bend or ventilation cowl, the warranty does not apply.
-
The gaskets are placed on the connection on the back of the toilet. Their purpose is to fit tightly between the toilet and the vent tube to prevent air and odor should coming out in the space where the toilet is placed.
-
To prevent the outgoing air from flowing back into the space where the toilet is placed, do not place the air intake (fresh air valve) and the vent outlet (vent cowl) too close together.
-
Fresh air valve may only be placed on an exterior wall. Placement in the floor or ceiling is not approved.
INSTALLATION
- You can choose from three different options to install your incinerating toilet.
- NOTE! Only Ø110 mm vent.pipes made of plastic, 1pcs 90° long bend and 2pcs 45° connectors (to go around the roof ridge) may be used in the installation.
Option
- A: Connectionpipe (horizontal) max 500 mm, install with 2° inclination backward from the toilet. Min 100 mm between the toilet and the wall.
- B: Max 5 meters in total length from the 90° bend.
- C: Max 500 mm above the roof.
- A ventilation valve is placed on an outer wall. If placed directly behind the toilet, underneath the ventilation pipe, min 110 mm Ø, if placed elsewhere min 160 mm Ø.
- NOTE! Only Ø110 mm vent. pipes made of plastic and 1pcs 90 ° bend may be used in the installation.
- A: Connectionpipe (horizontal) max 500 mm, install with 2° inclination backward from the toilet. Min 100 mm between the toilet and the wall.
- B: Max 4,5 meters in total length from the 90° bend.
- C: Max 500 mm and min. 300 mm between the 45° bends to go around the roof ridge.
- D: Max 500 mm above the roof.
- A ventilation valve is placed on an outer wall. If placed directly behind the toilet, underneath the ventilation pipe, min 110 mm Ø, if placed elsewhere min 160 mm Ø.
- NOTE! Only Ø110 mm vent. pipes made of plastic, 1pcs 90° long bend, and 2pcs 45° connectors may be used in the installation.
- A: Use the supplied short connection pipe (70 mm) between the toilet and the 90° bend.
- B: Max 5 meters in total length from the 90° bend.
- C: Max 500 mm above the roof.
- D: Attach the supplied hose on the drain tap on the 90° bend to divert condensation.
- The ventilation valve is placed on an outer wall, min 160 mm Ø.
- NOTE! Only Ø110 mm vent. pipes made of plastic and 1pcs 90° long bend may be used in the installation. When installing a 90 ° bend tube directly behind the toilet, 30 cm space is required for installation behind the toilet.
Separett AB 2020, 11977-06