This product is intended for installation only by expert users. Please consult
with a qualified technician for installation.
Improper installation may result in damage to your equipment. Before you start
using this product please follow these basic guidelines: C L-w25g.c U 00S W-A
- Please carefully read the manual before beginning the installation process
- It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant.
- Please remove your graphics card from your motherboard to ensure the safest process and in order to prevent any possible damages to your CPU and motherboard.
- DO NOT USE any kind of alcohol or alcohol derivatives with this reservoir or the acrylic tube may crack and fail! Do not clean it using alcohol either
Parts List
CPU Water Block
Pump/ Reservoir
Fan & Radiator
Accessory
TT RGB Plus Software control interface
Please download software from Thermaltake Official website.
www.thermaltake.com/home.aspx
and search” TT RGB Plus” on the official website.
OS compatibility: Windows 7 / 8 / 8.1 / 10
When you open the software, choose the plug what you onnect in the drop-
down list(C-4) first.
Software User Interface
-
TT RGB Plus software Profile Setting
A-1 Set up a profile: Choose a Profile and set up the LED Lighting Mode, then click the SAVE icon(A-3) to store your settings to the software.
A-2 Save a profile to controller: Select a profile and a controller,then click the Save icon to assign the profile to the controller. -
Follow the controller Installation Guide step 2, you can set uI> the number of the controller
-
LED Lighting Mode
Full Lighted/ Wave/ Pulse/ Ripple/ Microphone/ Sound effe / RGB Spectrum I Flow/etc .. -
C-1 LED Selection: set up the LEDs lighting, color, and speed.
Light Mode: Choose a lighting mode
Color Mode : Choose the LEDs color
Light Speed: Set up the speed of the LEDs light
LED Spot & Color Palette: Choose the color of each of the individual LEDs by clicking the color palette Done: Save your setting
Default: Reset the LED setting back to the default
Brightness: Drag the mouse to adjust LED light brightness.
LED On/Off: Click the LED Light icon to turn on or off the LED light
RGB Color Code: Enter the Decimal Code of Red, Green, and Blue to set the LEDs color -
C-2 Performance Mode: 500-1500RPM(Duty cycle0%-100%)
Silent Mode: 500-900RPM(Duty cycle0%-50%)
PWM Mode: The PWM function can be turned off and set the fan :;peed manually -
C-3 LED On/Off: User can switch off the LED control function in the software if the fan is not plug into the controller. C-4 Product Selection: click the product name to choice another you want.
-
C- 5 Fan LED Ring Selection: Choose different fan ring to setting the lighting modes.
-
D- 1 & D-2. Product Selection: click the control panel to rotate it to the front
2.Mobile APP Connection Password
To connect the TT RGB Plus APP, please connect the PC to your
wireless first, and click the Password setting under the software
setting menu, set up your connection password. The TT RGB Plus APP will ask
for your password every time when starting the APP.
For more information please visit
www.thermaltake.com
software interface may vary with feature update, please download the latest user manual from our www.thermaltake.com
CPU Water Block Installation Guide
Intel LGA 775,LGA115x,LGA1366
Intel LGA2066,2011-3,2011
AMD
Installation Guide
CAUTIONS: Make sure there is enough space when you s’lart to set up the
LCS product
Please use the wrench to install/ uninstall thE1 base parts during all the
installation
Pump/ Reservoir
Choose the proper way to mount the pump and reservoir by referring to the
manual (suggest vertical placement)
Attach fittings onto the pump and reservoir
Installation Walkthrough
cutting Attaching the Tubing
- MBasure the tube length based ori the base part of the fitting, and make (bend) the tubes. The loop order: Pump Outlet Water Block
- Measure the tube length based on the base part of the fitting, and make (bend) the tubes. The loop order: Water Block Radiator
- Measure the tube length based on the base part of the fitting, and make (bend) the tubes. The loop order: Radiator Reservoir inlet
- Fit the C-Pro fitting to the tube according to the order in the picture below, Install the tubes and tight the fitting caps.
- Finished
Filling the System
CAUTIONS:
- Before filling the system, please make sure that each fitting as well as unused ports are completely sealed.
- If there Is any case of leaking, immediately turn off the power and clean the leak
- If there Is any related electronic parts stained on liquid coolant, make sure to completely clean and dry the components. And then make sure they all work well.
- Aller switching off the power supply, connect the PSU power cord and product cables.
- Use the refill bottle to fill coolant into the reservoir
- Place your PSU outside of the case and attach it to the pumps 4pin mo lex connector, turn on the power of the PSU and rn. like the rest of the system fills up.
Thermaltake recommends the following steps to be taken after completing your water loop setup
- It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while preventing the entire cooling system -copper, brass, nickel, aluminum, and steel -from corrosion.
- Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
- DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
- Fill the reservoir to the top as it will prevent air from going into the pump
- If necessary tilt the system slightly from side to side to bleed the air out of the loop.
- Place some paper towels under fittings and joining points to test for leaks.
- Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop.
Installation Guide
- Connect the plug into the port in numerical order, start with plug one.
- Set the DIP switch on the back side of the controller to assign the number of the controller.