General Introduction On Outdoor Application
This detector is remarkable in function, but the following notices can make it
more stable if installer can pay attention to them:
WEEDS
High weeds and shrubbery in detection range may wave in wind and cause false
alarm, especially for those detectors operating in horizontal fan area, so
keep cutting on weeds and shrubbery.
RAIN
Sudden rainstorm can cool the hot pitch road or surface of other roads
quickly. And all detectors can detect rain in the sky, but detector with down
view window can even detect water on ground, which will bring much more
interference to detectors outdoor than that mounted on wall, so everything
will lower its temperature similar to water, human body or cars after pouring
from rain can offer very little temperature gap for detection, so sensitivity
will be lowered a lot.
INSECTS
Insects will trigger false alarm when they climb into detector or stay on
lens, while those staying away from detectors can’t trigger alarm. If there is
interference from insects, please re-install detector or use insecticide. And
please adopts strictly sealed components on those drilled holes or glass glue
around detector.
CAR
Moving car in detection range may trigger false alarm to detector.
INSUFFICUENT TEMPERATURE DIFFERENCE
Detector is sensitive to change from temperature difference in detection area,
if target temperature is very close to previous environment temperature, there
will be no temperature change, detector sensitivity will be lowered and will
not be triggered sometimes when there is intrusion.
DIRT ON LENS
Lens becomes easily dirty when used outdoor, so please check the lens from
time to time in order to avoid alarm miss caused by low sensitivity from dirty
lens.
UNSTABLE INSTALLATION BASE
Detector will trigger false alarm easily if installation base can be
interfered by vibration, this is the reason why some detectors installed near
to street can cause false alarm easily.
INTRODUCTION
The detector is a dual pir outdoor wireless detector with intelligent solar charge technology;it can match most of the wireless control panels directly and all wired control panels by wireless-to-wired receiver (REC-4CH). This detector adopts intelligent multigrade digital recognition technology and unique SLT calculation to process the 2-way special pir signal and 1 way environmental temperature signal to reach the topgallant detection and lowest false and missing alarm. It can recognize waving object and real human motion; resist direct or reflective sunshine and accomodate the false alarm caused by speedy hot and cool air. The detector can operate in outdoor severe environment for long term. 8 bands of sensitivities for option, can take on the weather difference caused by rain, snow, hail, strong sunshine, gale etc, it is a purely high-class outdoor detector worthy of selection and usage.
BRIEF INTRODUCTION
- 2 Dual PYRO Sensors
- VLSI based electronics with movement speed spectrum analysis.
- 8 bands of sensitivities for option ;
- Digital environmental temperature detection ;
- Anti strongly mutative hot/cool air;
- Anti direct or reflective sunshine;
- Anti strongly mutative hot/cool air;
- Pet immunity up to 25kg (With particular pet lens)
- 18 bands Fresnel lens (Standard wide angle lens)
- Anti UV ABS housing
- Fully-sealed optical design
- All-directional bracket installation: H90°and V30°adjustable
SPECIFICATIONS
attery power : 3.7V lithium chargable battery,
Current: Static —70uA Alarm —20mA
DC Power Input: 9-16V DC 200mA (DC power)
Warm up period: 40s
Install high: 1.8m-2.4m
Alarm time: 2s
Anti RFI/EMI: 0.1-500MHz/3V/m
Anti-white light: >100000LUX
Low battery alarm: 3.2V
Temp compensation: intelligent digital compensation
Temperature: -10℃/+55℃
Humidity(RH): 95%
Sensitivity: 8 grades adjustable
Detect speed: 0.2m/s to 3.5m/s
Radio emission : ≥200m (Open space)
Frequency: 315/433MHz etc.
Encoding: PT2262
Dimensions: 160mm65mm50.5mm
Coverage: 12m12m 110°(Standard Lens) 12m3m 12° (Curtain Lens) 12m*12m 110°
(Pet Lens)
INSTALLATION GUIDE
Even though Detector can accommodate outdoor severe environments, the following factors shall be avoided during install-ation in order to get the reasonable detection:
|
---|---
No direct facing cold/hot source| Mount on a secure and stable base/object
|
Incorrect Installation (with pet immunity lens)| Place without enough sunshine
such as eave and umbrage etc
|
electrical interferences Keep away from strong| Keep away from high pressure
power
|
Don’t install on a tree| Avoid moving vehicles
On installation angle
Detection is with mechanical difference to intrusion angles
On installation position
On installation height
Recommended installation height is 1.8-2.4m
BRACKET INSTALLATION AND DIRECT INSTALLATION (FOR OPTION)
In order to get the maximum detection range, please install detector at 2.1m
height and adjust PCB position to “0” mark vertically. However, detector can
be installed at 4m superlatively.
Please guarantee that there is no source of interference nearby and the front
view of detector is wide and clear.
- Drill a hole on wall and insert the rubber stopper into the hole, fasten the detector by 3 screws.
- Open the front cover: release the bottom screw anticlockwise by a plus-screw-driver(no need to twist out from cover), lift out the cover from bottom and then turn on the power switch, red LED will flash for 40 seconds as warm-up, when LED stops, walking test can be performed. (Please refer to following content on other setting). Then, close the cover as figure and tighten the screw. (Refer to below figure for details)
- Decomposingsteps
Note : please wear on the rubber ring for water proof before fastening detector onto the wall. Or water might go into detector and cause damage .
The 12V power supply connection
Note: please do lead cable according to above instruction, don’t drill holes
to lead cable on top/back/side of detector, otherwise it will damage the
water-proof structure and cause false alarm or malfunction.
Connect external 12VDC power to detector as figure, lead the power cable from
bottom power-lead slot and seal the cable-lead hole by silicone sealant in
order to avoid water and insects go into detector, then connect power cable to
relevant terminals (Care for the polarities)
Warning : this terminal can only be connected by 9-16V DC power, illegal higher voltage will cause permanent destroy to detector.
PCB LAYOUT AND WIRELESS CODING
ID registration (coding with alarm control panels)
You can match detector with control panel before installation. When control
panel enters into learning status, you can press down STUDY button to trigger
detector and register its ID into control panel.
Setting of compliance with other control panels Oscillation resistor set:
Compliance with other control panels can be reached through regulation of
oscillation resistance on encoding chips. Refer to left figure, our
oscillation resistance is with 3 modes:
PT2262 protocol: 4.7M、3.3M、1.5M
EV1527 protocol: 430K、330K、100K
Data set: Proper coding data can be obtained by “DATA SET” pins for control
panel recognition: 1=D3;2=D2; 3=D1;4=D0 (Codes under some special protocols
might be inverse)
DIP SWITCH SETTING
Dip switch 1: (sensitivity control)
When dip switch 1 is set to OFFdetector is in high sensitivity mode.
When dip switch 1 is set to ON, detector is in low sensitivity mode.
Dip switch 2: (Setting on PIR pulse detection) When dip switch 2 is set to
OFF, detector is in 2 pulses mode.
When dip switch 2 is set to ON, detector is in 3 pulses mode.
Signal processing statement: this detector adopts digital direct signal-
analysis technology, digital processing CHIP will analyze those signals
detected by sensors in frequencies, scope, polarity etc, and make comparison
with those usual pet- data in data base and draw real conclusion on body
intrusion. So, here, pulse setting is just a general index, might not be
actual pulse quantity during signal processing.
When set to 2 pulse counting, detector is in high sensitivity, detection of 2
intrusion pulses may cause alarm usually.
When set to 3 pulse counting, detector is in low sensitivity, alarm will be
triggered only when 3 intrusion pulses are detected.
Dip switch 3: ( mode selection)
When dip switch 3 is set to OFF, detector is in USE mode.
When dip switch 3 is set to ON, detector is in TEST mode.
DIP4 LED control
When it is “OFF”LED is turn off to reach the purpose of energy saving and
concealed installation.
When it is “ON”, LED is turn on.
Note: after installation and walking test finished, dip switch 3 and 4 should
be set to OFF mode in order to extent battery life!
VERTICAL ADJUST
Adjustment can be made through the moving of PCB up and down as the left figure in order to reach the best detection
WALK TEST
Preparation: before test, please do set dip switch 3 & 4 to ON position and
choose proper sensitivity and pulse counts acccording to installation
environment and detction requirement, in order that detector can obtain best
operation.
Close the front cap, when LED indication is off, perform a transverse movement
to check the PIR performance through the red LED, this can avoid the dead
angle of PIR detection. PIR is in highest sensitivity when movement is
transverse to the detector.
NOTES AND WARNINGS
Even the most sophisticated detectors can sometimes be defeated or may fail to
activate due to: DC power failure/improper connection, malicious masking of
the lens, tampering with the optical system, decreased sensitivity in ambient
temperatures near that of the human body and unexpected failure of a component
or circuit. The above list includes the most common reasons for failure and it
is recommended that the detector and the entire alarm system be checked weekly
to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home &
property owners or renters should be prudent enough to continue insuring their
lives & property even though they are protected by an alarm system.
WARNING! Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the warranty. This device has been
tested and found to comply with the limits for a Class B digital device,
pursuant harmful interference in residential installations. This equipment
generates and uses or radiates radio frequency energy and if not installed and
used in accordance with the instructions, may cause harmful interference to
radio and television reception. There is no guarantee that interference will
not occur in a particular installation. If this device does cause such
interference, which can be verified by turning the device off and on, the user
is encouraged to eliminate the interference by one or more ofthe following
measures:
- Increase the distance between the detector and the electrical/electronic equipment.
- Connect the device to a different power socket which supplies power to the detector.