**Winsen ZP201 Refrigerant Gas Detection Module User Manual
**
Statement
This manual’s copyright belongs to Zhengzhou Winsen Electronics Technology
Co., LTD. Without the
written permission, any part of this manual shall not be copied, translated,
stored in database or
retrieval system, also can’t spread through electronic, copying, record ways.
Thanks for purchasing our product. In order to let customers use it better and
reduce the faults caused
by misuse, please read the manual carefully and operate it correctly in
accordance with the instructions.
If users disobey the terms or remove, disassemble, change the components
inside of the sensor, we shall
not be responsible for the loss.
The specific such as color, appearance, sizes &etc., please in kind prevail.
We are devoting ourselves to products development and technical innovation, so
we reserve the right to
improve the products without notice. Please confirm it is the valid version
before using this manual. At
the same time, users’ comments on optimized using way are welcome.
Please keep the manual properly, in order to get help if you have questions
during the usage in the
future.
ZP201 Refrigerant gas detection module
**Product Description
**
ZP201 refrigerant gas detection module adopts advanced multi-layer thick film manufacturing process semiconductor gas sensor element. The gas sensor element contains a filter adsorption layer to reduce the interference of alcohol and other gases, and has extremely high sensitivity to refrigerant gas. The module has been aged , calibration, calibration, with good consistency and high.
Features
High sensitivity, fast response, strong anti-interference ability, long life, stable operation, factory calibrated, sensor fault self-diagnosis
Application
Used for air conditioning, refrigeration system refrigerant leak detection.
Parameters
Model | ZP201 |
---|---|
Target Gas | Refrigerant gas R32 |
Output Data | PWM |
Working Voltage | 5.0±0.2V DC (No voltage reverse connect protection) |
Output Data | TTL level (200ohm protected resistance inside) |
Working Current | ≤80mA |
Warm Up Time | ≤3 min |
Alarm point | 5000ppm |
Operating Temperature | 0~50℃ |
Operating Humidity | ≤95%RH |
Storage Temperature | -20~60℃ |
Storage Humidity | ≤60%RH |
Size | 25×34×14.1mm(L×W×H) |
Weight | 5g |
Fig1.Structure(tolerance ±0.2mm)
Terminal definition
Pin | Name | Functi on |
---|---|---|
G | GND | Input power – |
R | / | / |
T | / | / |
O | Output | PWM signal output (need to connect external pull-upresistor) |
V | 5V | Input power + |
Figure 2: Module Pin Diagram
Definition of output signal
Status | PWMoutput |
---|---|
**** Preheating | **** H:75ms |
Work | H:75ms |
**** Alarm | **** H:225ms |
**** Fault | **** H:300ms |
Note: After the module enters the alarm state, it will keep the alarm state and will not switch to other states. It needs to be powered on again to exit the alarm state.
Cautions
-
Please do not put the module in organic solvent (include silica gel and other cementing
compound), painting, medicament, oils and fuels, high concentration gas etc. -
Please do not impact or vibrate the module seriously.
-
Please warm up for 5 min before first use.
-
Please do not use the module related with personal safety.
-
Please do not install the module in the severe convection environment.
-
Please do not put in the module in high concentration organic gas for long time.
-
Please supply the module with requested voltage as manual strictly, if voltage is higher than 5.5V, the module will be destroyed irreversibly.
Zhengzhou Winsen Electronics Technology Co., Ltd
Add : No.299, Jinsuo Road, National Hi-Tech Zone, Zhengzhou
450001 China
Tel: +86-371-67169097/67169670
Fax : +86-371-60932988
E-mail : sales@winsensor.com
Website : www.winsen-sensor.com
References