MAUCH PL Series Sensor Hub X8 Installation Guide
- June 14, 2024
- MAUCH
Table of Contents
- Installation:
- Wiring Schematic:
- Connection to external equipment:
- Connection To BEC:
- Sensor Connectors:
- Reset / Restart:
- Status LED:
- Alarm Out:
- External LCD / OLED display:
- Setup DIP switch:
- I2C connector:
- Sensor status indicator:
- Sensor indicator:
- Current display:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PL – Series Sensor Hub X8
Installation:
The Sensor Hub X8 can be either installed via double side tape, or screwed down to the main frame, by removing the 4 bottom M3 screws and drilling holes into the frame. Then reinstall the screws trough the frame. -> The original screws will be too short, so please replace them with longer ones according to your frame thickness.
Wiring Schematic:
Connection to external equipment:
Connection To BEC:
The Hub X8 is compatible to any PL or PC / BEC.
Please connect the special cable here with 2x 4p and 2x 4p. connectors
1st 4p ->
To PL or PC / BEC
1st 3p -> Hub X8 power port
2nd 3p -> Hub X8 sensor 1 input
2nd 4p -> PL-xxx sensor board 1
The supply voltage is 4.95-5.05V and the max. current should not exceed 0.5A.
The current draw of the Hub X8 (with active OLED) is 50mA, plus 8x 15mA
(current sensors) = 170mA (0.17A)
So even if we connect 2pcs X8 with 16 current sensors, plus a Hub X2 (15mA),
we’re still below the 0.5A.
(2 x 0.17A) + 0.015A = 0.335A
Sensor Connectors:
Please connect here any of PL-xxx sensors. However, all sensors
must be of the same current raƟng!
If you use less than 8 sensors, then it doesn’t matter where you connect the
sensors. However, sensor 1 must be always connected, via the 4p cable for
voltage measurement.
For more details, please check Pos. (9).
The 7 cables to connect the PL-xxx sensor boards (4p <-> 3p), come together
with the Hub X8 (L=200mm)
Only PL-xxx sensors can be used. The Hub X8 is not compatible with HS-xxx-xx
sensors!
If all 8 possible sensors are installed, but you want to fly your UAV with only
4 LiPo’s, then you can deactivate the unused current sensors, by either
disconnecting them from the Hub X8, or installing a switch into the GND wire
of the sensor board.
Do not install the switch into the + 5V or I-out cable! Do not install the
switch into the cable of sensor 1!
If the sensor is disconnected, or the GND wire is switched off, then the Hub X8
will deactivate the sensor input during boot up or restart.
Reset / Restart:
In case of any alarm (over current or under current), then you can perform an
reset, by either re-powering the Hub X8, or press the reset switch for a short
me.
If you press the reset switch longer than 2 seconds, then the Hub X8 will
restart. This is helpful if you deactivate installed sensors after switching
on the system.
It is possible to install an external reset / restart switch (not included),
the necessary 5p cable with connector is included.
2x red for external switch + 3x white for alarm relays output.
Status LED:
RED = During startup / Any alarm is active and the alarm relays is ON / If the
Reset – Restart switch is pressed.
GREEN = After booting up and all connected sensors are initialized / No active
alarm
Alarm Out:
Pin 3 = P -> The middle contact of the relays.
Pin 4 = NO (normal open)
Pin 5 = NC (normal closed)
Any power LED or buzzer can be connected here, but the max. current should not
exceed 1A.
The necessary 5p cable with connector is included. -> 2x red for external
switch + 3x white for alarm relays output.
External LCD / OLED display:
If the Hub X8 is installed in a place where the display is no more visible,
then you can connect here a standard 2×16 LCD display (4-bit data bus), but
please do not use any LCD displays with back LED light, as these lights can
draw easily more than 200mA and the supplied power from the Power-Cube might
be not enough.
You also can install an 2×16 / OLED display. The current draw of these
displays is minimal (30mA). Therefore, Internal and External display can be
active.
REM: External OLED displays with CFK cover and reset switch might be
available soon.
Please check Pos. (7), for how to activate / deactivate the internal and
external display.
Setup DIP switch:
S1| S2|
---|---|---
OFF| OFF| Internal and external display OFF
OFF| ON| Internal display ON and External display OFF
ON| OFF| Internal display OFF and External display ON
ON| ON| Internal and external display ON
S3| S4| S5| S6|
---|---|---|---|---
ON| OFF| OFF| OFF| PL – 050 Sensors
ON| ON| OFF| OFF| PL – 100 Sensors
ON| ON| OFF| OFF| PL – 200 Sensors
ON| ON| ON| ON| PL – 400 Sensors (PL-400 Sensors / release Q2-2024)
I2C connector:
Only for maintenance use to read out the log files.
This connector can not be used for flight controllers who only support I2C
mower modules. For example, Pixhawk 6x or equivalent.
Sensor status indicator:
The numbers 1 to 8 are for the current sensors and the symbol above indicates
the status.
_ = No sensor connected or sensor deactivated -> See Pos. (2)
= Sensor connected and current is within average.
L = The current of this sensor is at least 25% lower than the average
current of the other sensors -> Alarm relay active
H = The current of this sensor is at least 25% higher than the average
current of the other sensors -> Alarm relay active
Sensor indicator:
Here it is displayed how many current sensors are connected/active and the current range of the individual sensor.
Current display:
The display will show the summarized current of all sensors, based on the standard Amp/Volt settings -> See Pos. (12)
Current output and setup Mission Planner:
The output voltage from the Sensor Hub X8 is always optimized to be 0.0-3.3V from 0A to full current on all sensors. Doesn’t matter how many sensors are connected/active. This ensures, that we always use the full range of the FC analog input, to get the most accurate current readings as well as capacity consumption calculation.
For example:
4 x 100A Sensors = 0.0V @ 0A and 3.3V @ 400A -> Amp/Volt value = 120
5 x 200A Sensors = 0.0V @ 0A and 3.3V @ 1000A -> Amp/Volt value = 300
8 x 200A Sensors = 0.0V @ 0A and 3.3V @ 1600A -> Amp/Volt value = 480
Please follow the procedure here to setup the correct Amp/Volt value:
p://ardupilot.org/copter/docs/common-mauch-power-
modules.html
Standard values for Amp/Volt:
| 1x| 2x| 3x| 4x| 5x| 6x| 7x| 8x
---|---|---|---|---|---|---|---|---
PL-050| 20| 40| 60| 80| 100| 120| 140| 160
PL-100| 30| 60| 90| 120| 150| 180| 210| 240
PL-200| 60| 120| 180| 240| 300| 360| 420| 480
PL-400| n/a| n/a| n/a| n/a| n/a| n/a| n/a| n/a
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>