SHOCKFLO CS01 40A EV Charging Station Installation Guide

June 14, 2024
SHOCKFLO

SHOCKFLO CS01 40A EV Charging Station

Main part

SHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(1\)

  1. Master Device:
  2. Key Card swipe location
  3. LED Strip
  4. Charging Connector
  5. NEMA14-50 Plug
  6. Charging Connector Holder
  7. Accessories:
    • Installation and user guide*1
    • Key Card*1
    • Expansion Screw*4
    • APP User Guide*1
    • Wall Bracket*1
    • Common Screw*1

Product Specifications

SHOCKFLO CS01 EV Charging Station (40A)

Product model| CS0l
Charging Standard for EV| Type 1 (SAEJ1772)
Nominal Voltage| 240V AC 60Hz
Nominal Current| 40A
Applicable Plug| NEMA 14-S0P
Certification| FCC Energy Star
Protection Degree| IP65
Length| Input Cable: 1 ft ( 0.3m) Output Cable: 17 ft (5.2ml
Working temperature| -22°F to +l 22°F
Supported features| Regulates current and power

Schedule a charging start and end time

Start charging| ,1 Plug to play

2, Activate by swiping

3, Start immediately through the APP

4, Set a scheduled charging through the APP

Stop charging| 1, Automatic stop when fully charged 2, Stop by swiping

3, Immediately stop via APP

4, Schedule a time stop through the APP

APP connection method support| WIFI (2.4Ghz)

Bluetooth ( 5.1 )

Charging protection:| Current-leakage Protection Over-heat Protection Lightning Protection

Over-current Protection Under-current protection Over-voltage Protection Under-voltage protection Automatic Power-off

Poor grounding detection Emergency stop switch Temperature chip fault detection Measurement chip fault detection Relay detection

Product Installation Instructions

  1. Install PrerequisitesSHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(2\)
  2. Product Installation Steps
    • Attach the wall bracket to the wall, and mark 4 fixing points with a pencil; it is recommended to install within 1.3-1.6 meters from the ground.
    • Use an electric drill to drill holes equivalent to the diameter of the expansion screws at the 4 marked fixed points. (Expansion screw specification: M10*80).SHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(3\)
    • Fix the wall bracket on the wall, and plug the expansion screws into the 4 drilled fixing holes.
    • Tighten the nut with a wrench, so that the tail of the expansion screw is forced to open, and the wall bracket is fixed.SHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(4\)
    • After the charging device is hung on the wall
    • Plug it into a NEMA14-50R socket and you’re bracketed and fixed, lock the device, and it the ready to go. bracket with screws from the bottom.SHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(5\)

Charging Steps

SHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(6\)

  • The NEMA14-50 plug is connected to the power supply;
  • The charging connector is connected to the charging port of the electric vehicle;SHOCKFLO-CS01-40A-EV-Charging-Station-FIG-1 \(7\)

Light status during use

Normal light status Status indication explanation
Solid Blue The charging station is powered on, the charging connector is not

inserted into the car, and the APP is not connected to WiFi or Bluetooth;
Blinking Blue| The charging station is powered on, and connected to the charging port of the car, and the APP is not connected to WiFi or Bluetooth;
Solid Cyan| The charging station is powered on, the charging connector is not inserted into the car, and the APP is connected to Wifi or Bluetooth
Blinking Cyan| The charging station is powered on, and connected to the charging port of the car, and the APP is connected to Wifi or Bluetooth
Solid Green| Charging is complete, and the car terminal actively disconnects
Blinking Green| Charging is in progress
Blinking Yellow| The OTA upgrade is in progress. (The progress can be viewed on SHOCKFLO APP)
Malfunction
light status| status indication
explanation| Troubleshooting| Recovery Scenarios
After Troubleshooting
---|---|---|---
Red light flashes 1 time| Leakage| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will be back to normal after restarting
Red light flashes 2 times| Abnormal vehicle interaction| Contact Customer Service| After troubleshooting, restore by itself
Malfunction  light status status indication explanation Troubleshooting Recovery Scenarios After Troubleshooting

Red light flashes

3 times

| Overvoltage| Check power outlet voltage, contact the local power center or electrician to check| After troubleshooting, restore by itself

Red light flashes 4 times

| Under voltage| Check power outlet voltage, contact the local power center or electrician to check| After troubleshooting, restore by itself

Red light flashes

5 times

| Over current| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will return to normal after restarting
Red light flashes 6 times| Poor grounding| Check if the power outlet is grounded, contact your local power center/electrician to check| After troubleshooting, restore by itself
Red light flashes 7 times| Emergency stop|

Confirm the status of the emergency stop switch; release the emergency stop manually

| After troubleshooting, restore by itself
Red light flashes 8 times| Short circuit| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will return to normal after restarting
Red light flashes 9 times| Overheating| contact Customer Service| After troubleshooting, restore by itself
Malfunction  light status status indication explanation Troubleshooting Recovery Scenarios After Troubleshooting

Red light flashes 10 times| Temperature chip failure (missing or abnormal data measuring chip temperature)| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will return to normal after restarting
Red light flashes 11 times| Metering chip failure (missing or abnormal measurement of voltage, current, and electricity data)| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will return to normal after restarting
Red light flashes 12 times| Leakage protection function self-test is abnormal| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will return to normal after restarting
Red ligh flashes 13 times| Relay sticking| Contact Customer Service| After eliminating the problem, you need to unplug the plug and reconnect the power supply, and the device will return to normal after restarting

Caution

  1. This is for EV chargers with Type 1 inlet (SAE J1772), suitable for EVs with SAE J1772 charging ports.
  2. The device has a precise internal structure. If you have any questions, please contact our customer service at first time. Please don’t take it apart without any professional technical support.
  3. Do not soak the top of the charger connector in water.
  4. This product is only used for electric vehicle charging. Please do not use it for any other occasions including hauling, bundling, etc.
  5. Do not use the charger if the control box is damaged or an abnormal alarm occurs.
  6. The equipment must be grounded.
  7. It is not recommended to use this device with extension cords or adapters.
  8. Be aware of the risk of electric shock or burns.
  9. The device does not contain any user-serviceable parts.
  10. Do not disconnect the plug when the electric car charger is working.
  11. When you encounter problems with the use or failure of the charging station, please provide the Bluetooth name or product number of the product so that we can quickly help you solve the problem
  • BRAND URL: Explore More About SHOCKFLO
  • SERVICE CENTER: APP Download and Quick User Guide Q&A etc.

CERTIFICATION:

  • ENERGY STAR
  • EMAIL: support@shockflo.com.
  • If you have any questions, please contact our email address.

Please read all instructions carefully before use.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>