VEVOR T300 Wet Dry Vacuum Instruction Manual

June 14, 2024
VEVOR

VEVOR T300 Wet Dry Vacuum

SAFETY INSTRUCTIONS & WARNINGS

IMPORTANT SAFETY INSTRUCTIONS

  • For your safety: carefully read and understand all instructions, this appliance complies with mandatory safety regulations for electrical equipment. However, improper use will harm personal and property, please read these instructions carefully, and then open the electrical.
  • When using electrical appliances, you must follow basic precautions.
  • Do not allow other uses and unattended operation.
  • Check that the electrical voltage is correct before use.
  • Do not use the air outlet directly against people or animals when using this product.
  • The manufacturer can’t be liable for damages due to improper use or improper operation.
  • Do not inhale flammable, toxic liquids, such as gasoline, oil, acids or other volatile substances, to avoid dangerous hazards.
  • Only relevant professionals can repair electrical equipment. Improper repairs may result in considerable risk.
  • Do not store the appliance directly at high temperatures such as hot stoves or heat sinks.
  • Do not use a cleaning agent or detergent containing solvent.
  • This device does not apply to children or those who lack experience with the use of relevant products unless they have been supervised or instructed to use the equipment to be responsible for their safety. Children should be supervised to ensure that they do not play the device.
  • Turn off the appliance when cleaning or removing it. Before cleaning or servicing the appliance, remove the plug from the socket and pull the plug out of the socket.
  • Unauthorized parts or third part accessories may be dangerous to make the warranty invalid.
  • Always check whether the float is normal.
  • If you notice that the liquid leaks from your equipment, immediately turn it off and unplug the plug.
  • Do not use the appliance in a damp room.
  • Do not inhale hot dust ashes or sharp objects.
  • Do not touch the spectator directly when blowing. When the time to blow the children away. Wear safety goggles.
  • Do not reverse the vacuum cleaner, causing damage to the motor.
  • The hose can’t be overly bent and forced to elongate, otherwise the hose will be deformed or damaged.
  • Do not allow the lid part to penetrate into the water or rinse with water to prevent water from entering the electronic parts. Leakage, proper operation: gently wipe the surface with a rag.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

TECHNICAL DATA

  • RLP175-D1200-20PS
  • 120V~, 60Hz, 1200W, 20L, Class II, IPX4

PRODUCT PARTS NAME

VEVOR-T300-Wet-Dry-Vacuum-FIG-1

VEVOR-T300-Wet-Dry-Vacuum-FIG-2

According to different occasions to choose suitable accssorics:

  • A: Vacuum cleaner assembly
  • B: Soap bucket and connecting pipe
  • C: Handle hose assembly
  • D: Metal telescopic tube
  • E: НЕРА
  • F: Water absorbing sponge
  • G: Water spray carpet brush
  • H: Metal spray sofa brush
  • I: Wet dry floor nozzle
  • J: Crevice nozzle
  • K: Multi brush

INSTALLATION

VEVOR-T300-Wet-Dry-Vacuum-FIG-3

Caution: Make sure that the power cord plug and socket are de-energized when assembling the vacuum clean you purchased.

  1. Make sure the power cord is disconnected from the socket. (Fig1)
  2. Loose Clips. (Fig2)
  3. Raise the nose assembly from the dust pan. (Fig 3)
  4. Take out all accessories from the dust container. (Fig 4)
  5. Place the nose assembly on the dust barrel that already has a filter assembly and lock it with both sides of the clips. (Fig 5)
  6. Align the hose assembly port with the suction port and insert it into right and tighten it. (Fig6)
  7. Tighten the lid of the soap bucket to the right while inserting the water inlet joint at the water pump inlet on the head. (Fig7)
  8. Connect telescopic tube with the connect into the handle and insert the water inlet pipe into the water inlet of the handle. (Fig8)
  9. The telescopic tube can be adjusted to different lengths. (Fig9)
  10. Connect wet dry floor nozzle with telescopic tube. (Fig10)

OPERATION OF VACUUMING DUSTS

VEVOR-T300-Wet-Dry-Vacuum-FIG-4

  1. Make sure the power cord is disconnected from the socket. (Fig1)
  2. Loose Clips. (Fig2)
  3. Raise the Head assembly from the dust tank. (Fig 3)
  4. Install HEPA, press HEPA tightly on the bottom cap basket. (Fig4)
  5. Place the nose assembly on a dust bucket, and lock it with both sides of the buckle. (Fig5)
  6. Align the hose assembly port with the suction port and insert it into right and tighten it. (Fig 6)
  7. Connect telescopic tube with the connect into the handle and insert the water inlet pipe into the water inlet of the handle. (Fig 7)
  8. The telescopic tube can be adjusted to different lengths. (Fig8)
  9. Connect wet dry floor nozzle with telescopic tube. (Fig 9)
  10. Insert the power cord. (Fig 10)
  11. Start the vacuum switch. (Fig 11)
  12. Start vacuuming dusts. (Fig12)

WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED ‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO; LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL OR AEROSOL SPRA VS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO; COAL, MAGNESIUM, GRAIN OR GUN POWDER. TO REDUCE THE RISK OF HEAL TH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
VEVOR-T300-Wet-Dry-Vacuum-FIG-5 VEVOR-T300-Wet-
Dry-Vacuum-FIG-6

  1. The dust inside the dust bucket is full. (Fig 1)
  2. Turn off the vacuum switch. (Fig 2)
  3. Unplug the power cord. (Fig3)
  4. Release the buckle. (Fig 4)
  5. Raise the nose assembly from the dust container. (Fig 5)
  6. Pour out the garbage in the dust bucket. (Fig 6)

OPERATION OF WATER CLEANING

VEVOR-T300-Wet-Dry-Vacuum-FIG-7

  1. Make sure the power cord is disconnected from the power supply. (Fig1)
  2. Cover the bottom cap basket with watering absorbing sponge, make sure cover the whole basket.(Fig2)
  3. Place the nose assembly on a dust bucket, and lock it with both sides of the buckle (Fig 3)
  4. Connect wet dry floor nozzle with telescopic tube. (Fig4)
  5. Insert the power cord. (Fig 5)
  6. Start the vacuum switch. (Fig6)
  7. Start absorbing water. (Fig 7)
  8. When the water is absorbed to the maximum capacity, the safety valve operates, the suction port has no suction, turn off the vacuum switch. (Fig8)
  9. Make sure the power cord is disconnected from the power supply. (Fig 9)
  10. Pouring water. (Fig 10)
  11. To ensure the best results of water absorption, please remove the air filter sponge, hand-wring dry after drainage. (Fig 11)
  12. Wash the sewage sponge with cleaning water, hand-wring dry after washing, then be used again.(Fig 12)

WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED ‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO. LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE PAINTS, GASO­LINE, ALCOHOL OR AEROSOL SPRA VS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO. COAL, MAGNESIUM, GRAIN OR GUN POWDER. TO REDUCE THE RISK OF HEAL TH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS .
OPERATION OF CARPET CLEANING

VEVOR-T300-Wet-Dry-Vacuum-FIG-8 VEVOR-T300-Wet-
Dry-Vacuum-FIG-9

  1. Make sure the power cord is disconnected from the power supply ( Fig1)
  2. Cover the bottom cap basket with watering absorbing sponge, make sure cover the whole basket.(Fig2)
  3. Place the nose assembly on a dust bucket, and lock it with both sides of the buckle (Fig 3)
  4. Align the hose assembly port with the suction port and insert it into right and tighten it. (Fig 4)
  5. Remove the Soap bucket from the pedestal, then unscrew the lid to the left, and fill it with a clean mixture mixed in an appropriate proportion (Fig 5)
  6. Insert one end of pipe (with elbow) into the inlet joint on the head; Place the other end of inlet pipe with the filter into the Soap bucket, then tighten the lid to the right. (Fig 6)
  7. Connect telescopic tube with the connect into the handle and insert the water inlet pipe into the water inlet of the handle. (Fig 7)
  8. The telescopic tube can be adjusted to different lengths. (Fig 8)
  9. Connect the spray felt brush with an expansion tube and insert the water inlet pipe of the spray felt brush into the water inlet of the remote control handle. (Fig 9)
  10. Insert the power cord. (Fig 10)
  11. Start the Water pump switch. (Fig 11)
  12. Start cleaning. (Fig 12)

WARNING

  1. When cleaning carpet, please use low foam cleaner and add appropriate anti-foaming agent mix evenly, otherwise the air outlet will have the possibility of foam eject.
  2. It is recommended that users immediately empty the sewage in the vacuum cleaner dust tank after using 2 buckets of cleaning fluid each time to prevent the liquid in the dust bucket from being too high and causing the possibility of foam spraying out from the air outlet.
  3. In the cleaning mode, when there is no cleaning fluid in the Soap bucket, please add it in time. Do not idle the water pump to prevent damage to the water pump.
  4. When the dust bucket is full or the safety valve is blocked, the sound of the motor will obviously become louder. At this time, the dust bucket should be shut down and emptied immediately.

OPERATION OF BLOWER

VEVOR-T300-Wet-Dry-Vacuum-FIG-10

WARNING: ALWAYS WEAR SAFETY GOGGLES BEFORE USING BLOWER.
WARNING: KEEP BY STANDERS CLEAR FROM BLOWING DEBRIS.
WARNING: WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED.

  1. Make sure the power cord is disconnected from the power supply. (Fig 1)
  2. Unscrew the inserted hose assembly from the suction port with a left-hand rotation. (Fig 2)
  3. Insert the main tube of the hose assembly into the air outlet at the back of the head and tighten it by rotating it with the right hand. (Fig 3)
  4. Insert the power cord. (Fig 4)
  5. Start the vacuu m switch. (Fig 5)
  6. Hold the hose assembly, let outlet port aimed at the leaves and so on. (Fig 6)

FILTER CLEANING

VEVOR-T300-Wet-Dry-Vacuum-FIG-11

  1. Periodically check the cleaning filter to maintain performance.
  2. If the suction very tiny dust, the filter may need more frequent cleaning.
  3. Wash filter sponge with cold or warm water without the use of detergent. (Fig 1 & Fig 2)
  4. Keep the cleaned parts in a wide area to dry, try to keep dry and dry for at least 24 hours.
    Do not put the filter in a dishwasher, washing machine, roller dryer, oven, microwave oven or open flame. (Fig3)

MAINTENANCE

  1. After cleaning the barrels, filters and related accessories, check if leaks. After each use, clean the filter and do not use a wet filter at all times.
  2. Check the plug if damage, place the plug.
  3. Check whether there is something plug the air intake, if any, please clean.
  4. Carefully put the machine, do not beat.
  5. keep the machine dry.
  6. If filter covered with dust, wash with cold water, if necessary, may also use neutral detergent cleaning, Do not use corrosive objects to clean. Do not put entire head directly in the water cleaning.
  7. Do not let the machine work for a long time, each working time is best in 2 hours, otherwise will reduce the machine life.
  8. After a long time the filter will be covered the dust, suction will be weakened. To avoid the weakening of suction, always clean the filter.
  9. If any abnormal vibration or noise or smell, Must immediately stop using the machine, and maintenance.

TROUBLESHOOTING

WARNING! to reduce the risk of electric shock-unplug before troubleshooting

Symptom Possible Causes Corrective Action

Vacuum will not operate

|

  1. No power supply.

| 1) Check power supply -cord, breakers, fuses.

  1. Faulty power cord.

| 2) Unplug and check the power cord. If damaged, have it repaired by a professional.

  1. Container full.

|

  1. Empty container.

Dust comes out from motor cover.

|

No filter installed, the filter is not installed in place or the filter is damaged

| Re-install and check whether the filter installed in place. Replace the new filter if any damage is found.

Reduced efficiency and motor/speed vibration.

|

There is a blockage in the nozzle or hose, or the container inlet. Or dust filter blocked by fine dust.

| Check nozzle, hose and container inlets for blockage. Take off the filter and clean it. Or install new cartridge filter.

Does not spray cleaning fluid

|

1. Cleaning mode is nots elected

2.Use up the cleaning fluid in the soap bucket

3. The pipe line is not properly installed

| 1. press the water pump switch

2.Reinsertion the cleaning fluid

3.Check whether the water pipe connection is in place correctly and pay attention to check whether the water pipe is knotted.

Foam coming out of the machine head unit outlet

|

High bubble cleaning fluid was used

| Replace the low-bubble cleaning solution and add defoaming agent according to the ratio.

WARRANTY INFORMATION

  • The manufacturer provides warranty in accordance with the legislation of the customer’s own country of residence, with a minimum of 1 year (Germany: 2 years), starting from the date on which the appliance is sold to the end user.
  • The warranty only covers defects in material or workmanship.
  • The repairs under warranty may only be carried out by an authorized service center. When making a claim under the warranty, the original bill of purchase (with purchase date) must be submitted.
  • The warranty will not apply in cases of:
  • Normal wear and tear
  • Incorrect use, e.g. overloading of the appliance, use of non-approved accessories
  • Use of force, damage caused by external influences
  • Damage caused by non-observance of the user manual, e.g. connection to an unsuitable mains supply or non-compliance with the installation instructions
  • Partially or completely dismantled appliances

CONTACT

  • E-mail: CustomerService@vevor.com
  • Manufacturer: Zhejiang Roly Technology Co., Ltd.
  • Add: No.366 Huaxia Road, Economic Development Zone, Yongkang, hejiang, O,ina.
  • Made in China

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals