roambee 2ALG8BSLB Bee Label Owner’s Manual

June 13, 2024
roambee

roambee 2ALG8BSLB Bee Label Owner’s Manual

General Overview

Product name Bee Label
Model name BL 100
  101 mm × 177 mm × 0.8 mm
Dimensions ****
  4 in × 7 in × 0.3 in
  34 g
Weight ****
  1.2 oz
Housing Paper label

Available information

| Temperature, Motion, Shock data

and events, LTE-1/2G, GPS,

Battery and system

statu

Ingression protection rating| IP54
Flight detection| Yes
(U)SIM Interface| eSIM Card

Temperature Calibration

Calibration points| ****

-30 ± 1.0°C

| ****

+5 ± 0.5°C

| ****

+65 ± 1.0°C

---|---|---|---

Technical data


Technical data

|
---|---
Battery type| Non Rechargeable Li-MnO2 1800 mAH. Lithium content 0.62g.


Battery life

| Device transmits data for 10 to 50 days on a single charge,

depending on cloud reporting interval, as detailed on page 2.

LEDs| 1 Power LED
Charging| Non rechargeable
Storage Capacity| 10000 messages
Cellular network type| 4 G ( LTE- 1 ) and GSM
Cellular coverage| Global
Cellular Antenna| Internal
GNSS Antenna| Internal, GPS/ GLONASS/ BDS/ Galileo QZSS

Measurement Data


Measurement Interval

Sampling rate

| ****

6 minutes (Minimum)

---|---


Data Reporting

| The device needs to wake up and

establish a connection to upload

measurement data to the Roambee HC Cloud.


Wake-up schedule

| Adjustable from 6min to 24h

frequency. The device wakes up when an excursion triggers an

alarm, regardless of the schedule.


Gravity Measurement Range

Logs SHK: Yes

| ****

±2 g/ ±4g/±8 g/±16 g

ODR Bandwidth for Accelerometer| ****

1 Hz ~ 400 Hz

Temperature range

Logs Temperature: Yes

Cloud connection: Can be established. Battery life: Normal

| ****

-30°C to +70°C

Humidity Range

Logs Humidity: Yes Battery life: Normal

| ****

0 to 99% RH


Absolute Accuracy

| ****

3-Point NIST Calibration


Ambient and Tamper range

Illuminance Range: 1 to 100 Lux

| ****

1-100 LUX adjustable levels

Certifications

Approvals CE, FCC, IC, NOM, KC
Aviation compliance IATA, FAA and EASA

Battery type

The device is powered by a non rechargeable Li-MnO2 battery, 1800 mAh. Li- MnO2 batteries are not considered dangerous goods when shipped with the device.

Battery life

A fully charged device on a 1-hour wake-up interval can be expected to upload data and report alarms for at least 30 days while monitoring an active shipment within the operating sensor ranges.
The device enters hibernation mode when the battery level reaches 10% or less, at which stage it stops attempting to connect to the Roambee cloud.
The battery life depends on the set wake-up interval, as shown in the table below.

Wake-up interval Battery life
15 mins 15 days
30 mins 30 days
1 hours 6 0 days
6 hours >60 days

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority t o operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installat ion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause har mful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should b e installed and operated with minimum distance 20cm between the radiator and your body.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals