Koppel KV18WR-ARF31A Window Type Full DC Inverter Air Conditioner Owner’s Manual

June 11, 2024
koppel

Koppel LOGO KV18WR-ARF31A Window Type
Full DC Inverter Air Conditioner
Owner’s Manual

IMPORTANT NOTE:
Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.

Remote Controller Specifications

Model| RG51A/E, RG51A(1)/EU1, RG51A/CE, RG51A10/E,  RG51Y5/E
RG51B/E, RG51B(1)/EU1, RG51B/CE, RG51B10/E, RG51Y6/E
---|---
Rated Voltage| 3.0V( Dry batteries R03/LR03×2)
Signal Receiving Range| 8m
Environment| -5°C~60°C(23°F~140°F)

NOTE: For models of RG51Y5/E and RG51Y6/E, If the unit is turned off under COOL, AUTO or DRY mode with the set temperature less than 24 C, the set temperature will be automatically set to 24 C when you turn on the unit again. If the unit is turned off under HEAT mode with the set temperature more than 24 C, the set temperature  will be automatically set to 24 C when you turn on the unit again.
Quick Start Guide

Koppel KV18WR ARF31A Window Type Full DC Inverter Air
Conditioner

NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE

  • Button designs on your unit may differ slightly from the example shown.
    If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.

  • When there are wide differences between “Remote controller Manual” and “USER’S

  • MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.

Handling the Remote Controller

Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner -
FIG

BATTERY NOTES
For optimum product performance:

  • Do not mix old and new batteries, or batteries of different types.
  • Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.

BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS FOR USING REMOTE CONTROL

  • The remote control must be used within 8 meters of the unit.
  • The unit will beep when remote signal is received.
  • Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
  • Remove batteries if the remote will not be used more than 2 months.

CAUTIONS FOR USING REMOTE CONTROL
The device could comply with the local national regulations.

  • In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
  • In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself.  For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
2

Model: RG51A/E, RG51Y5/E, RG51A(1)/EU1 RG51A10/E(20-28 C)
RG51A/CE(Cooling only models, AUTO mode and HEAT mode are not available)

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
3

Model: RG51B/E, RG51Y6/E, RG51B(1)/EU1 RG51B10/E(20-28 C)
RG51B/CE(Cooling only models, AUTO mode and HEAT mode are not available)

Remote Screen Indicators

Information are displayed when the remote controller is power up.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
4

Mode display
AUTO COOL DRY HEAT FAN

| Displayed when data transmitted.
---|---
| Displayed when remote controller is ON.
| Displayed when TIMER ON time is set
| Displayed when TIMER OFF time is set
| Shows set temperature or room temperature, or time under TIMER setting
| Displayed when ECO feature is activated (some unit)
| Indicated all the current settings are locked
| Displayed when Follow Me feature is activated(some units)
| Displayed when SLEEP feature is activated

Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation, only the relative function signs are shown on the display window.

How to Use Basic Functions

Basic operation
ATTENTION! Before operation, please ensure the unit is plugged in and power is available.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
5

COOL Mode

  1. Press the MODE button to select COOL mode.
  2. Set your desired temperature using the TEMP or TEMP button.
  3. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
  4. Press the ON/OFF button to start the unit.

SETTING TEMPERATURE
The operating temperature range for units is 17-30°C (62-86°F)/20-28 C.
You can increase or decrease the set temperature in 1°C (1°F) increments.

AUTO Mode
In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT operation based on the set temperature.

  1. Press the MODE button to select AUTO.
  2. Set your desired temperature using the TEMP or TEMP button.
  3. Press the ON/OFF button to start the unit.

NOTE: FAN SPEED can’t be set in AUTO mode.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
6Koppel KV18WR ARF31A
Window Type Full DC Inverter Air Conditioner - FIG 7

FAN Mode

  1. Press the MODE button to select FAN mode.

  2. Press FAN button to select the fan speed:
    AUTO, LOW, MED or HIGH.

  3. Press the ON/OFF button to start the unit.

NOTE: You can’t set temperature in FAN mode.
As a result, your remote control’s LCD screen will not display temperature.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
8

DRY Mode (dehumidifying)

  1. Press the MODE button to select DRY.
  2. Set your desired temperature using the TEMP or TEMP button.
  3. Press the ON/OFF button to start the unit.
    NOTE: FAN SPEED cannot be changed in DRY mode.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
9

HEAT Mode

  1. Press the MODE button to select HEAT mode.
  2. Set your desired temperature using the TEMP or TEMP button.
  3. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
  4. Press the ON/OFF button to start the unit.

NOTE: As outdoor temperature drops, the performance of your unit’s HEAT function may be affected. In such instances, we recommend using this air conditioner in  conjunction with other heating appliances.

Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.

TIMER ON setting

Press TIMER ON button to initiate the ON time sequence.| Press Temp. up or down button for for multiple  times to set the desired time to turn on the unit.| Point remote to unit and wait 1sec, the TIMER ON will be activated.
---|---|---
Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
10

TIMER OFF setting

Press TIMER OFF button to initiate the OFF time sequence.| Press Temp. up or down button for for multiple  times to set the desired time to turn off the unit.| Point remote to unit and wait 1sec, the TIMER OFF will be activated.
---|---|---
Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
11

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will  increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
  2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
12

Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.

How to Use Advanced Functions

Swing function
Press Swing button

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
13

The horizontal louver will swing up and down automatically when pressing Swing button.
Press again to make it stop.

Airflow direction

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
14

LED DISPLAY

Press LED button
Press this button to turn on and turn off the display on the indoor unit.

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
16

Keep pressing this button more than 2 seconds, the vertical louver swing function is activated. (Model dependent)
Each time you press the button, it will adjust the louver by 6 degrees . Press the button until the direction you prefer is reached.

Press this button more than 5 seconds(some units)
Keep pressing this button more than 5 seconds, the indoor unit will display the actual room temperature. Press more than 5 seconds again will revert back to display the setting temperature.

ECO function

Press this button under COOL Mode to enter the energy efficient mode.
(For model of RG51A/E, RG51A(1)/EU1, RG51A/CE, RG51A10/E, RG51Y5/E)
Note: This function is only available under COOL mode.
Under cooling mode, press this button, the remote controller will adjust the temperature automatically to 24°C/75°F, fan speed of Auto to save energy (only when the set  temperature is less than 24°C/75 °F). If the set temperature is above 24°C/75°F, press the ECO button, the fan speed will change to Auto, the set temperature will remain  unchanged.

NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set temperature to less than 24°C/75°F will stop ECO operation.
Under ECO operation, the set temperature should be 24°C/75° F or above, it may result in insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.

SHORTCUT function

Used to restore the current settings or resume previous settings.
(For model of RG51B/E, RG51B(1)/EU1, RG51B/CE, RG51B10/E, RG51Y6/E)
Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed  level and sleep feature(if activated).
If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep  feature (if activated ).

SLEEP function

The SLEEP function is used to decrease energy use while you sleep (and don t need the same temperature settings to stay comfortable). This function can only be activated via remote control.
The sleep function is not available in Fan or Dry mode. Please refer to the OWNER’S MANUAL for more details.

Silence function

Keep pressing Fan button for more than 2 seconds to activate/disable Silence function(some units).
Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button while  operating will cancel silence function.

FP function
Press this button 2 times during one second under HEAT Mode and setting temperature of 17 C/62 F or 20 C(for models of RG51A10/E & RG51B10/E).

The unit will operate at high fan speed (while compressor on) with temperature automatically set to 8 C/46 F.
Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting temperature of 17 C/62 F or 20 C(for models of RG51A10/E and RG51B10/E) to activate FP  function.
Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel this function.

Temperature display

Koppel KV18WR ARF31A Window Type Full DC Inverter Air Conditioner - FIG
23

Press together & buttons at the same time for 3 seconds will alternate the temperature display between the °C & °F (Applicable for models of RG51A(1)/EU1 and RG51B(1)/EU1 only)

Koppel LOGOA Tradition of leadership and excellence for over 50 years

KOPPEL, INC
Koppel Head Office:
106 Industry Drive, Carmel ray
Industrial Park 1, Bogy. Caliban,
Calamba City, Laguna 4028
Tel No.: (02) 8823-88-83
Website: www.koppel.ph

Iloilo Office:
Door 8 & 9 NSB Bldg.,
Rizal Street, Lepus, Iloilo City
Tel No.: (033) 330-2926

Cebu Office:
Door 1 & 2 Roizen Bldg.,
A. Cortez Avenue, Mandaue City
Tel No.: (032) 346-7278
Fax No.: (032) 346-7279

Davao Office:
J.P. Baguio Avenue, Davao City
Tel No.: (082) 221-6419
Fax No.: (082) 221-6418

Cagayan De Oro Office:
7878 Warehouse 1, Bogy. Rugman,
Cagayan De Oro City
Tel No.: (088) 880-6326

Documents / Resources

| Koppel KV18WR-ARF31A Window Type Full DC Inverter Air Conditioner [pdf] Owner's Manual
KV18WR-ARF31A Window Type Full DC Inverter Air Conditioner, KV18WR-ARF31A, Window Type Full DC Inverter Air Conditioner, DC Inverter Air Conditioner, Air Conditioner, Conditioner
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals