HOMCOM 821-018V91 Portable Quiet Dehumidifier Instruction Manual

June 14, 2024
HOMCOM

HOMCOM 821-018V91 Portable Quiet Dehumidifier

HOMCOM 821-018V91 Portable Quiet Dehumidifier -product

PRODUCT DESCRIPTION

  • The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity.
  • The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because of its efficient energy properties, R290 is highly suitable as a coolant forthis application.
  • Special precautions must be taken into consideration due to the coolant’s highflammability.

WARNING

  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

SYMBOLS FROM THE UNIT AND USER MANUAL

  • If the user ignores this warning and mishandles the product, it may result in serious and fatal injury or death to the user.
  • If the user ignores this note and mishandles the product, it may result in injury to the user, or material damages.
  • This unit uses a flammable refrigerant.
  • If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.
  • Read the USER MANUAL carefully before operation.
  • Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.
  • Service personnel are required to carefully read the USER MANUAL and SERVICE MANUAL before operation.

THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

  • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • The unit is designed only for use with R-290(propane) gas as the designated refrigerant.
  • The refrigerant loop is sealed. Only a qualified technician should attempt to service!
  • Do not discharge the refrigerant into the atmosphere.
  • R-290 (propane) is flammable and heavier than air.
  • It collects first in low areas but can be circulated by thefans.
  • If propane gas is present or even suspected, do tallow untrained personnel to attempt to find the cause.
  • The propane gas used in the unit has no odor.
  • The lack of smell does not indicate a lack of escaped gas.
  • If bleak is detected, immediately evacuate all persons fromthe store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.
  • Do not let any persons back into the store until the qualified service technician has arrived and that technician advises that itis safe to return to the store.
  • No open flames, cigarettesor other possible sources of ignition should be used inside or in the vicinity of the units.
  • Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced with identicalrepair parts.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be disconnected from its power source during maintenance.

FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.

FOR YOUR SAFETY

GENERAL PRECAUTION

  • Turn off the dehumidifier when cleaning.

  • Unplug the power cord when not in use

  • Do not operate with wet hands.

  • Prevent water from spilling onto the machine.

  • Do not unplug while the unit is operating

  • Do not unplug by pulling on the power cord.
    HOMCOM 821-018V91 Portable Quiet Dehumidifier -01

  • Always use a power outlet that is grounded.

  • Do not use an extension cord or anadapter plug.

  • Keep the air inlet and outlet free of obstacles.

  • Do not tilt or turn over the unit.

  • Do not put objects on the unit

  • Do not climb or sit on the product.

HOMCOM 821-018V91 Portable Quiet Dehumidifier -02

  • Take care to ensure that children do not play with the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • Do not store in dusty] place,or expose under cor rosive environment environment.
  • Service or repair should be performed by a qualified technician.
  • Replace the assembly with] the manufacturer approved replacement parts.

HOMCOM 821-018V91 Portable Quiet Dehumidifier -03

OPERATIONALPRECAUTIONS

WARNING – to reduce the risk of fire, electric shock or injury to persons or property

  • Always operate the unit from a power source of equal voltage, frequency and rating asindicated on the product identification plate.
  • Do not leave the unit running unattended.
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not operate the product with damaged plug or cord. If it i s not working properly, contact a qualified electrician or service centre for examination and repair, never try to dismantle it by yourself (user).
  • The unit shall be installed in accordance with national wiring regulations.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
  • The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • The appliance shall be stored so as to prevent mechanical damage from occurring
  • Do not piece or burn, even after use.
  • Be aware that refrigerants may not contain an dour.
  • Pipe work shall be protected from physical damage and shall not be installed in an u unventilated space, if that space is smaller than 4m².
  • Compliance with national gas regulations shall be observed.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well ventilated area where the room size corre spends to the room area as specified for operation.
  • If you don’t understand something or need help, please contact the dealer services.

SAFETY PRECAUTIONS ON SERVICING

  • Please follow these warnings when to undertake the following when servicing a dehumidifier with R290.

Checks to the area

  • Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

Work procedure

  • Work shall be undertaken under a controlled procedure so as to minimize the risk of flammable gas or vapor being present while the work is being performed.

General work area

  • All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around theworkspace shall be sectioned off. Ensure that the conditions within the area have been medusae by control of flammable material.

Checking for presence of refrigerant

  • The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the lea detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.

Presence of fire extinguisher

  • If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder orCO2 fire extinguisher adjacent to the charging area.

No ignition sources

  • No person carrying out work in relation to a refrigeration system which involves exposing anytime work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

Ventilated area

  • Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

Checks to the refrigeration equipment

  • Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
  • The following checks shall be applied to installations using flammable refrigerants
  • The charge size is in accordance with the room size within which the refrigerant containing parts are installed
  • The ventilation machinery and outlets are operating adequately and are not obstructed;
  • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
  • Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
  • refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

Checks to electrical devices

  • Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
  • Initial safety checks shall include
  • Those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking.
  • That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
  • That there is continuity of earth bonding.

WHERE TO USE

Installation

  1. Place the unit on a firm, level surface in an area with at least 20cm of free space around it allow for proper air circulation.

  2. Operate this unit in an ambient temperature from 5°C to 35°C.

  3. Keep doors and windows close for better energy saving.

  4. Do not operate in close proximity to walls, curtains, or other objects that may block inlet and outlet.

  5. Do not operate the unit beneath furniture or where the air flow is restricted.

  6. Do not operate or store the unit in direct sunlight or rain.

WARNING
Install the unit in rooms which exceed 4 m².

  • Do not install the unit in a place where inflammable gas may leak.

NOTE

The manufacture may provide other suitable example or may provide additional information about the refrigerant odour.

Making dry and comfortable

  • Smartly senses room humidity and maintain your ideal levels.

To dry clothes quickly.

  • Continuous dehumidifying to speed the drying process

Sleep well into the night.

  • Silence dehumidifying and dims the lights when you sleep.
  1. Unpacking the appliance and check for any damage or scratches on the machine.
  2. If tipped more than 45°, allow the unit to set upright for at least 2 hours before start up.
  3. Check the bucket is empty and re install correctly before plug in the dehumidifier. Be sure the bucket full indicator does not light up.
  4. Press POWER to turn on the dehumidifier.
  5. Press   MODE repeatedly to choose AutoSunny (60%RH), Auto Rainy (40%RH), or Continuous Drying.
  6. Press  SLEEP for silent operating with dim light before go to bed.
  7. Press TIMER repeatedly to set a 1 hour to 24 hour delay OFF before you go out.
  8. Press POWER again to turn the unit off.

For more operational instructions, please read the following pages.

PRODUCT OVERVIEW

FEATURES

  • ✓ Powerful moisture removal
  • ✓ Antibacterial Filter
  • ✓ C ontinuous Drainage or 2L Water Tank
  • ✓ L aundry Drying Function / Child Lock / Auto Defrost
  • ✓ Touch Screen / Touch control buttons
  • ✓ Humidity Monitor shows current air humidity.
  • ✓ Auto mode automatically adjusts humidity levels.
  • ✓ Effectively removes moisture, dust, and dust mites from the air.
  • ✓ Low power consumption energy efficient.
  • ✓ A 24 hour timer to set the time of operation.
  • ✓ Quiet fan has two speed settings. Noise: 36dB A
  • ✓ Sleep mode dim s the control panel light when you sleep.

HOW TO USE

CONTROL PANEL

Display

  1. The screen will display current relative humidity (%) when the machine is turned on. And display “一一” when the machine is off.
    The screen will display following function:

  2. Timer set;

  3. Error code;

  4. Long press HUM key to display Room temperature (℃);

  5. The indicators will light up when the corresponding function is turned on.

POWER BREATHING LIGHT

FUNCTION KEYS AND INDICATORS

HOMCOM 821-018V91 Portable Quiet Dehumidifier -018

SETTINGS

  • Dehumidification Mode Setting

    • Press POWER key to turn on the unit after plug in.
    • The dehumidifier starts with sunny mode and air purifying function.
  • Press MODE key repeatedly to switch the mode
    Sunny mode: auto dehumidifying with 60%RH, High fan speed.
    Rainy mode: auto dehumidifying with 40%RH, high fan speed.
    Continuous mode: continuous dehumidifying

  • Set Sleep Mode
    Press SLEEP key to turn on sleep function.
    It will operate in silent mode with low fan speed and dims all the lights.
    Press any button to wake up the indicators.
    Press SLEEP key again to exit the sleep mode.

  • Set Humidity (setting range: 20%-95%)

    • Press the HUM key to check the humidity set-point under current mode.
    • Press the HUM key repeatedly to adjust humidity set-point.
    • Set appropriate humidity levels to create a comfortable environment.
    • Note: The HUM key cannot be set in the continuous mode.
  • Set Fan Speed
    Press SPEED key to switch the speed between High speed and Low speed.

    • Note : The fan speed cannot be set when the indicator is off in sleep mode and defrosting progress.
  • Child Lock Function
    The child lock function is designed to prevent children from playing unit.

    • To active: Long press the SPEED/LOCK key for 5 seconds to disable all the buttons.
    • To unlock: Press and hold again to cancel the child lock.
  • In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.

Timer Setting Setting
setting range : 1hour 1hour-24hours24hours

HOMCOM 821-018V91 Portable Quiet Dehumidifier -027

  • Water full indicator:
    The machine automatically shuts off once the water tank is full, alerting the user through an indicator light and buzzing for 15 times.It reminds you to check:

    • If the water tank is full, empty and re-install the water tank.
    • If the water tank is not in position, the full indicator always on and the unit is inoperative.
    • Re-install the tank correctly, and the unit will auto operating as your last setting.
  • Room Temperature Inspection
    In addition to the humidity level, the digital display can also indicate the current room temperature. Please check as follows

    • Press and hold the TIMER button for 5 seconds.
    • The screen displays the temperature in degree Celsius.
  • Auto defrost function
    At low room temperatures, frost may buildup at the evaporator reducing the airflow across it during dehumidifying.
    The unit will automatically start defrosting and the POWER indicator flashing.
    When the room temperature below18℃ or the humidity sensor failures, the compressor stops for 10 minutes during the automatic defrost function and the fan keeps running.

DRAINAGE

  • There are two ways of removal collected water produced by the unit.
    • Manual draining: Empty water tank by manual.
    • Continuous draining: Use gravity to drain condensate water by attaching a drain hose.

|

  • Unplug the dehumidifier from its power source.
  • Pull on the water tank and simply slide out of the body of the dehumidifier.

---|---
|

  • Do not remove the float out of the tank. Make sure that the float can move freely and that it will actuate the level switch when the tank is full.
  • Clean the inside of the tank as well as the outside.

|


  • Allow the tank to air-dry completely and slide it back into place within the dehumidifier.
  • After you have replaced the tank, plug the unit back into its power source.

Warning
Use only mild soap, water and soft cloth. Do not use any commercial cleaning solvents.

CONTINUOUS DRAINAGE
Condensate water can be automatically flow into a bucket or drain by gravity with a water hose.

  • Set the unit in a horizontal surface and stable position.
  • Switch off the unit before operating.
  • Gently take out the water tank from the dehumidifier.

|

---|---

  • Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
  • Put back the water tank.
  • Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
  • Do not submerge the end of hose into water; otherwise it can cause “Air Lock” in the hose.

|

Inner Diameter

=9.5mm

To avoid water spillage

  • As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor.It is appropriate that the degree of inclination should exceed 20 degrees.
  • traighten the hose to avoid a trap existing in the hose.

|

CLEANING AND CARE

CLEANING THE AIR FILTER (every two

  • The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated. Do not clean the appliance with any chemicals.

CLEANING THE AIR FILTER (every two weeks)

n  The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated. Do not clean the appliance with any chemicals.


Pic1. Switch off the unit and remove air filter.

Warning
Do not touch the evaporator surface with bare-hand, or could cause injury of your fingers.

| Pic2. Rinse the air filter under running water.

Pic3. Re-install the air filter.

TROUBLESHOOTING

When| Please confirm|

Solution

---|---|---
The unit is not operating.| ü Check the power connection in

securely.

| Ø Insert the power cord securely into

the wallOutlet.

Check if the water level indicator

lights up?

| Empty the water tank and re-install

correctly.

Check the room temperature.| he range of operating temperature is 5-35℃.
There is little formation of condensate.| Check the air filter for dirt.| Clean the air filter as necessary.
Check if the air duct is blocked.| To clear the obstacle.
Check if the room temperature is

below 20℃.

| This is normal. Low humidity in low temperature environment.
Set humidity level is higher than

currenthumidity value.

| Ø Set the humidity level below current

humidity value.

Water Leakage| ü Overflow while moving the unit.| Empty the water tank before

transport.

Check if the drain hose is kinked or

bends.

| Straighten the hose to avoid a trap

existing.

Excessive Noise| heck if the unit is securely

positioned.

| Ø Place the unit on horizontal and firm

ground.

Check if any loose, vibrating parts.| Secure and tight the parts.
Noise sounds like water flowing.| Noise comes from flowing refrigerant.

This is normal.

Emitting hot

|

ü The air outlet is hotter than room temperature a bit.

| This is normal. The compressor produce heat that has been removed by the air exhausted.

Error Code

| E2| Humidity sensor dampened or

failure.

| To clean or replace the humidity

sensor.

CL| Display when Room temperature is

below 5°C(41°F).

| Normal. The compressor stops, and

the fan keeps running.

CH

| Display when Room temperature is

above35℃(95°F).

| Normal. The compressor stops, and the fan keeps running.
LO| Display when Room relative

humidity is bellow 20%RH.

| Normal. The compressor stops, and

the fan keeps running.

HI| Display when Room relative

humidity is above 95%RH.

| Normal. The compressor and the fan

keep running.

SPECIFICATIONS

Model No. OL12-BD001E

Power Supply

|

AC220V-240V/50Hz

Power Consumption

| 180W (30℃, RH80%)
156W (27℃, RH60%)

Rated Current

| 0.95A (30℃, RH80%)
0.88A (27℃, RH60%)

Dehumidify Capacity

| 821-018V70/821-018V90: 12L/24h (30℃, RH80%)
821-018V91: 16L/24h (30℃, RH80%)
Noise| ≤36dB(A)
Water Tank Capacity| 2L
Refrigerant /Charge| R290/60g
Minimum room size| 4 m2 (Floor area)
Fuse type| T-Type, AC 250V, 3.15A
Operating temperature| 5ºC-30ºC
Dimension| 280x200x500mm
Net weight|

Note
Specifications subject to change without notice

STORAGE AND DISPOSAL

STORAGE

  • Long-term storage – If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely.
  • Please store the unit per the following steps.
  1. Unplug the unit.
  2. Empty the water tank and dry with a cloth.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Collect the power cord at the tank and re-install it.
  5. Re-install the filter at its position.
  6. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
  7. The unit must be kept in upright position when in storage.

ATTENTION
The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to set the humidity point more than 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.

DISPOSAL

WARNING

  • Releasing refrigerant into atmosphere is strictly forbidden!
  • According to European Directive 2012/19 / EU on waste electrical a electronic equipment and transposition into national law, used electrical appliances must be collected separately and recycled in a environmentally sound manner.

Read User Manual Online (PDF format)