SPECIFICATIONS
SKU
Model
Microbolometer
Type | Uncooled |
---|---|
Resolution, pixels | 640×480 |
Pixel size, µm | 12 |
Frame rate, Hz | 50(PAL) |
Optical characteristics
Magnification| 1x-2x-4x-6x
Smooth Scaling| Yes
Horizontal field of view, degree| 12.5
Field of view, m at 100 m| 9.4
Exit pupil diameter,mm| 18
Eye relief, mm| 20
Close-up range, m| 2
Display
Type| OLED
Resolution, pixel| 1600×1200
Operational characteristics
Power supply, V| 4.5-9.0
External power supply| 5V(USB)
Degree of protection (attachment / monocular),
IP code (IEC60529)| IP67
Operating temperature| -20℃~+50℃/-4℉~+131℉
Dimensions,mm/inch| 198 x 64 x 78.8 MM
Weight(without batteries), kg/oz| 758g / 26.7oz
Not supported when replacing eyepiece / monocular during rain
PACKAGE CONTENTS
- Incenses PRO
- Eyepiece attachment
- Neoprene bag
- Certificate of inspection
- Lens cloth
- Warranty card
- Charging data cable
FEATURES
- 640×480 pixel sensor size
- The device is mountable on any standard picatinny rail
- Observation range greater than 1000 yards
- Micro chromatic OLED display (1600×1200 pixels)
- Can be used as a stand-alone thermal optic with independent reticle
- Any external battery can be used with the USB-C external power source
- You can view the stored files (videos and pictures) in the machine memory after connecting to the computer through TYPE-C.
- Three scene modes, image enhancementhigh, Hight brightness and standard brightness
- 8 pseudo-color modes, including white hot, black hot, red hot, green hot,IronRed,Fire,YellowHot,and Lava
- Sustainable operation at temperatures from -4 °F to +122 °F
- Compact size
- Lightweight
EXTERNAL VIEW AND CONTROLS
- Lens
- Focusing Ring
- USB-C Interface
- Eyepiece
- Power Button
- UP Button
- REC Button
- MENU Button
- DOWN Button
- Power Bank
Buttons| First long press| Next long press| Short press|
Menu operation
---|---|---|---|---
Short press| Long press
“Power”| Turn on the Incenses PRO| Turn off the Incenses PRO| Refresh shutter|
—| —
Display off| Display on| —-| —-
“UP”| Switch the reticle type (Scope mode works)| Switch magnification| Switch
menu option| —
“DOWN”| Turn Power the reticle (Scope mode works)| Switch the pseudo-color
mode| Switch menu option| —
“MENU”| Functional menu display| Functional menu close| Switch the scene mode|
Functional setting and parameter storage| Back to the top/ Functional menu
close
“REC”| Start recording video| End recording video| Take a picture| —| —
MENU / STATUS BAR ICONS:
Notes: When the Incendis PRO is simultaneously used with a traditional
riflescope, select the cursor position adjustment to adjust the cursor’s
central position and make it consistent with the reticle of your traditional
riflescope; when the Incendis PRO is used as a stand-alone optic, turn on the
reticle; the screen displays the reticle, select the reticle adjustment, and
adjust the reticle using the X & Y adjustments.
GUIDELINES FOR OPERATION
To maintain stable operation of the product, please observe the following
rules:
- Before use, ensure that the device is installed and adjusted;
- When it is not use, Shut down the machine and unplug the TYPE-C plug;
- When cleaning the non-optical surface of the Incendis PRO, do not wipe it with chemical solvents. It is better to wipe the shell by using clean, soft, and dried cloth.
- Any attempt to dismantle or maintain the Incendis PRO will void the warranty.
EXTERNAL POWER SUPPLY
Open the USB-C rubber plug , insert the USB cable into the USB-C interface,
and insert any 5V USB mobile power to another USB interface of the USB cable
to supply power.
OPERATION
Start and setup
- Leave the rubber lens cover on, press “Power” button until the Acquire logo appears on the screen.
- Remove the lens cover, rotate the optical focusing ring until the image is clear.
Adjust magnification
Short press “UP” button to switch the device magnification between 1x, 2x, 4x,
and 6x in order.
Switch the pseudo-color mode
Briefly press the “Down” button to switch between 8 pseudo-color modes in
sequence.
Switch the scene mode
Short press “MENU” button to switch the scene mode between image enhancement,
high brightness and standard brightness.
MENU
Long press “MENU” button to make the device enter into the first-level menu
mode; in the first-level menu mode, long press the button “MENU” to exit the
menu mode and return to the main screen; in the first-level menu mode, short
press the button “UP” or the button “DOWN” to conduct the functional
selection.
Screen brightness
Image Quality => Screen Brightness: Adjust the screen display brightness,
adjustable range from 0 to 100.
The compensation mode
Shutter compensation
control shutter closure to collect shutter data for non-uniform correction;
Automatic compensation will be made when the device is powered on and started,
and automatic compensation will be closed after starting. If shutter
compensation is needed, you need to manually press the Power button.
View video/Photo files
Connect the Incendis PRO to your computer with a type-c data cable and open
the video/photo folder to view.
Hotpoint track
Image Quality => Hotspot Tracking: Turn it on, and the Red Cross on the screen
automatically tracks the hottest spots in the image.
System sleep:
Enter the sleep mode manually: Press the Power button and release the button
during shutdown to close the screen display and enter the sleep mode to reduce
power consumption.
Sleep timer: System => Timed Sleep: Support 20,30, and 60 minutes without
button operation, close the screen display, enter the sleep mode. This
function is disabled by default.
power off
Long press the Power button to complete the shutdown when the circular
countdown ends.
Factory reset
Restore the parameters to the default settings, and all files on the memory
card remain. If you need to empty the SD content, please use the SD card
formatting function. Restore the default password for wifi to eight “0s”, etc.
Image Contrast
Image contrast adjustment range is 0~100; The default is 100.
Image brightness
Image brightness adjustment range is 0~100; The default is 60.
Reticle On/Off
Reticle/Sight-In => On/Off :Turn on/off the reticle; This function is only
supported in Scope mode, it’s does not support reticle operation in Clip-On
mode.
Reticle adjustment
Reticle/Sight-In => Sight-In/Collimation : Reticle position adjustment: In
Clip-On mode, you adjust the position of the picture on the screen; In Scope
mode, the position of reticle was adjusted.
USING THERMAL IMAGING FINDER WITH OTHER OPTICAL DEVICES
The Incendis PRO not only used as a stand-alone optic, but also can be used in
tandem with other optical devices , such as the traditional riflescope.
MAINTENANCE AND STORAGE
- The protection grade of the device is IP67.
- Please keep the device in a dry and well-ventilated place. To lengthen the service life, please disconnect the power cable after each use.
- The battery should not be exposed to direct sun or heat.
- If the front lens is dirty, use the cloth provided to remove dust on the lens surface. Do not blow the lens surface by mouth to prevent saliva particles from smudging the lens surface.
- If the cloth does not thoroughly remove the dust, please prepare absolute ether and absolute ethyl alcohol(ethyl alcohol), mix it at the ratio of 1:1, use the degreasing cotton(medical cotton ball) with the mixture, start from the lens center to the outside of the lens in circular motion, and lightly wipe the lens surface.
- Do not use an old cloth or reused alcohol mixture cotton as a cleaning tool.
- Do not use the glasses cloth, handkerchief, lens tissue or ordinary tissue for wiping.
COPYRIGHT @ 2022 ACCUFIRE TECHNOLOGY ALL RIGHTS RESERVED
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated and meets general RF exposure requirements. This device can be used under portable exposure conditions, with a minimum distance of 15mm from the human body.
References
Read User Manual Online (PDF format)