Whynter ARC-1230WN Smart Portable Air Conditioners Instruction Manual
- June 14, 2024
- Whynter
Table of Contents
- ARC-1230WN Smart Portable Air Conditioners
- DISPOSAL INFORMATION
- SAFETY PRECAUTIONS
- SAFETY COMPLIANCE
- PREPARATION
- INTRODUCTION
- ACCESSORIES
- WINDOW KIT INSTALLATION
- CONTROL PANEL
- OPERATION INSTRUCTION
- REMOTE CONTROL
- CARE AND MAINTENANCE
- TROUBLESHOOTING
- WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ARC-1230WN Smart Portable Air Conditioners
Instruction Manual
ARC-1230WN Smart Portable Air Conditioners
Congratulations on your new Wynter product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.
DISPOSAL INFORMATION
Thank you for choosing Wynter. Please follow the instructions provided in this
user manual to obtain the very best performance from your steam oven. We trust
that your Whynter steam oven will provide the performance and reliability that
we stand for. Please keep this user manual in a safe place for future
reference. This symbol on the product or its packaging indicates that this
appliance cannot be treated as normal domestic trash, but must be handed in at
a collection point for recycling electric and electronic appliances. Your
contribution to the correct disposal of this product protects the environment.
Further information about the recycling of this product can be obtained from
your local municipal authority.
Caution: Risk of fire/ flammable materials (Required for R32/R290 units
only)
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air
conditioning unit. Make sure to save this manual for future reference.
Explanation of symbols displayed on the unit(For the unit adopts R32/R290
Refrigerant only):
| WARNING| This symbol shows that this appliance used a flammable
refrigerant. If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire.
---|---|---
| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
SAFETY PRECAUTIONS
Read Safety Precautions Before Operation and Installation
To prevent death or injury to the user or other people and property damage,
the following instructions must be followed. incorrect operation due to
ignoring of instructions may cause death, harm or damage.
- Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
- Use only the included accessories and parts, and specified tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fire, and injury or property damage. Make sure that the outlet you are using is grounded and has the appropriate voltage.
- The power cord is equipped with a three-prong grounding plug to protect against shock.
- Voltage information can be found on the nameplate of the unit.
- Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maxi mum current of the unit. The maximum current is indicated on the nameplate located on unit), have a qualified electrician install the proper receptacle.
- Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
- The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
- Do not modify the length of the power cord or use an extension cord to power the unit.
- Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
- Ensure there is a minimum of 36″ clearance around the unit and is clear from any combustible items such as propane, fire extinguishers, fuel, etc.
- The exhaust hose should always be used and should never be covered or blocked which can become a fire hazard. • The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping.
- Do not operate a unit that it has been dropped or damaged.
- Do not place the portable air conditioner close to any other heat generating appliances
- Do not touch the unit with wet or damp hands or when barefoot.
- If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visu ally inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
- Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. unplug immediately if it occurs.
- All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
- The unit’s circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
- When the water drainage function is not in use, keep the upper and the lower drain plug firmly plugged into to the unit to pre vent choking.
CAUTION
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- Children must be supervised around the unit at all times.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
- Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
CAUTION
- Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Return to an authorized service facility for examination and/or repair.
- To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations.
- Contact the manufacturer or authorized service technician for repair or maintenance information of this unit.
- Contact the manufacturer or authorized installer for installation questions of this unit.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning, turn off the power and unplug the unit.
- Disconnect the power if strange sounds, smell, or smoke comes from it and contact the
- manufacturer or authorized service technician for assistance.
- Do not press the buttons on the control panel with anything other than your fingers.
- Do not remove any fixed covers. Contact Wynter Customer Support if this unit if it is not working properly, or if it has been dropped or damaged.
- Do not operate or stop the unit by inserting or pulling out the power cord plug.
- Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapor such as alcohol, insecticides, petrol, etc. Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
- Always contact Wynter Customer Support for replacement parts compatible with your unit. Hold the plug by the head of the power plug when taking it out.
- Turn off the product when not in use.
WARNING
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn the unit.
- Be aware that the refrigerants may not contain an odor.
SAFETY COMPLIANCE
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer.
- Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- Please follow the instructions carefully to handle, install, clear, and service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32) shall be recovered properly and shall not discharge to air directly.
- No any open fire or device which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used.
- Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
- Flammable refrigerant R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard. For specific information on the type of gas and the amount, please to the relevant label on the unit itself.
PREPARATION
All illustrations in the manual are for explanation purpose only. Your machine
may be slightly different. The actual shape shall prevail. The unit can be
controlled by the unit control panel alone or with the remote controller.
DESIGN NOTICE
In order to ensure the optimal performance of our products, the design
specifications of the unit and remote control are subject to change without
prior notice.
EXHAUST HOSE INSTALLATION
The innovative hose-in-hose design delivers more than 2x faster and
stronger cooling. The hoses and adapter must be installed or removed in
accordance with the usage mode. For COOL mode & HEAT mode (only for ARC-
1230WNH ), the adapter and exhausts must be installed. For FAN or DRY mode,
the adapter and exhaust hoses can optionally be removed.
CHOOSING THE RIGHT LOCATION Your installation location should meet the
following requirements:
- Make sure that you install your unit on an even surface to minimize noise and vibration.
- The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
- The unit should be located at least 25cm (9.8″) from the nearest wall to ensure proper air conditioning. The horizontal louver blade should be at least 50cm (19.7″) away from obstacles.
- DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.
AMBIENT TEMPERATURE RANGE FOR UNIT OPERATION
MODE | TEMPERATURE RANGE |
---|---|
Cool | 62-95’F I 17-35’C |
Dry | 62-95’F I 17-35’C |
Heat (heat pump mode) | 41-86’F I 5-30’C (only for ARC-1230WNH) |
INTRODUCTION
INTRODUCTION TO INVERTER TECHNOLOGY
As pioneers in the air comfort space, we are introducing next generation
technology currently used only in high efficiency ductless mini-split air
conditioners. The Inverter technology will be featured in our NEX line of
portable air conditioners. By utilizing this much more efficient technology,
Whiner’s Inverter variable-speed system allows the compressor to optimize
efficiency and power consumption together, while maintaining a specified
output.
This allows for a much quieter operation and significantly reduced energy con
sumption. The Inverter technology system potentially reduces energy usage by
more than 40% while the new hose-in-hose design delivers more than double the
cooling output. Below are the advantages of inverter technology; At least 40%-
50% cheaper to run as it consumes less power Quicker to achieve desired
temperature
- Quieter operation
- No temperature fluctuations
- No voltage peaks from compressor
HOSE-IN-HOSE COOLING SETUP
The innovative two-hose in one design and the sealed bottom structure ensure
no heat leakage. This cooling setup extracts and exhausts air from the
outdoor, so the indoor space reaches an independent and balanced cool air
circulation. As a result, the entire room can be cooled down quickly and
effectively.
Model | ARC-103OWN | ARC-1230WN | ARC-123OWNH |
---|---|---|---|
Operational Modes | Cool / Fan / Dry | Cool / Fan / Dry | Cool / Fan / Dry / Heat |
Cooling Capacity | 12,000 BTU I SACC 10,000 BTU | 14,000 BTU I SACC 12,000 BTU |
14,000 BTU I SACC 12,000 BTU
Heating Capacity| –| –| 12,000 BTU
Coverage Area| 500 sq. ft.| 600 sq. ft.| 600 sq. ft.
Fan Speed| Continuous I Auto I Low I Medium I High| Continuous I Auto I Low I
Medium I High| Continuous I Auto I Low I Medium I High
Noise Level| 42.5 / 49.5 / 53.5| 42.5 / 49.5 / 56.5| 47.2 / 52.6 / 56.8
Temperature Range| 60-86°F| 60-86°F| Cooling: 60-86°F I Heating: 60-86°F
Timer| Up to 24 hours| Up to 24 hours| Up to 24 hours
Refrigerant| R32| R32| R32
Power Consumption| 1266W| 1293W| 1298W
Amps| 12.| 12.| 12.
Power Supply| 115V/60Hz| 115V/60Hz| 115V/60Hz
CEER I EER| 12.3 I 10.0| 12.3 I 10.8| 12.3 I 10.8
Net Weight| 72.8 lbs| 75 lbs| 77.2 lbs
Unit Dimensions| 19.5″ W x 16.7″ D x 32.5″ H| 19.5″ W x 16.7″ D x 32.5″ H|
19.5″ W x 16.7″ D x 32.5″ H
WHAT SHOULD I LOOK FOR WHEN PURCHASING A PORTABLE AIR CONDITIONER?
The right air conditioner helps you cool a room efficiently. An undersized
unit won’t cool adequately while one that’s too large will not remove enough
humidity, leaving the air feeling damp. To find the proper air conditioner,
determine the square footage of the room you want to cool by multiplying the
room length by its width. You also need to know the air conditioner’s BTU
{British Thermal Unit) rating, which indicates the amount of heat it can
remove from a room. Why is the cooling capacity lower on newer models than on
older units? A higher number means more cooling power for a larger room. (Be
sure you are comparing only newer models to each other- older models may
appear to have a higher capacity, but are actually the same). Be sure to
“size up” if your portable air conditioner will be placed in a very sunny
room, in a kitchen, or in a room with high ceilings. After you’ve found the
right cooling capacity for your room, you can look at other features.
WHY IS THE COOLING CAPACITY LOWER ON NEWER MODELS THAN OLDER MODEL$?
Federal regulations require manufacturers to calculate cooling capacity based
on a specific test procedure, which was changed just this year.
Models manufactured before 2017 were tested under a different procedure and
cooling capacity is measured differently than in previous models.
So, while the BTUs may be lower, the actual cooling capacity of the air
conditioners has not changed.
WHAT IS SACC?
SACC is the representative value of Seasonally Adjusted Cooling Capacity, in
Btu/h, as determined in accordance with the DOE test procedure at title 10
Code of Federal Regulations (CFR) 430, subpart B, appendix CC and applicable
sampling plans.
ACCESSORIES
Image | Accessory | Qty |
---|---|---|
Hose-in-hose (Air intake hose & exhaust hose) | 1 set | |
Air outlet adapter | 1 piece | |
Exhaust Connector | ||
Module ABC* | 1 piece |
each
| Window Slider A| 1 piece
| Window Slider B| 1 piece
| Foam Seal A (Adhesive)| 2 pieces
| Zip Tie
( For ARC-1230WNH model only)| 2 pieces
| Foam SealB (Adhesive)| 2 pieces
| Foam Seal C (Non-Adhesive)| 1 pieces
| Security Bracket| 1 set
| Drain Hose Adaptor (For ARC- 1230WNH model only)| 1 piece
| Power Cord Buckle (N/A for ARC- 1230WNH model)| 1 piece
| Bolt| 1 piece
| Remote Control| 1 set
| Drain Hose Adaptor| 1 piece
| Washable Filter (preinstalled)| 1 piece
WINDOW KIT INSTALLATION
Adjustable Window Slider Option
- Measure the window opening where the window kit will be installed.
- Assemble as many sliders as necessary to fit the window. If the window opening is less than the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is necessary to attach the exhaust hose adapter.
- Use the window slider bolts to secure the window sliders at the correct length.
Hoses Connector Modules (For Sliding Window)
Assemble the exhaust adapter module for sliding windows using the exhaust
connector screw as shown. The window slider is eccentric so the exhaust
adapter must be installed away from the wall.
Note: For vertical installation, exhaust hose connector module B can be
omitted.
- Rotate the exhaust hose gently backwards.
- Pull out the exhaust hose away from the wall.
Hose-in-hose
NOTE: To ensure proper functioning, DO NOT overextend or bend the hose.
Make sure that there is 20″ of clearance around the air outlet of the exhaust
hose in order for the exhaust system to work properly.
All illustrations in this manual are for explanation purposes only. Your air
conditioner may be slightly different. The actual shape shall prevail.
NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods.
Hung Window or Sliding Window Installation
-
Cut adhesive foam seals A and B to the correct lengths and attach them to the window frame as shown.
-
Insert the window slider kit into the window opening and close the window the secure it in place.
-
Cut the non-adhesive foam seal C to match the width or height of the window and insert it between the panes of glass as shown to prevent outside air from entering the window.
-
If desired, install the security bracket with 2 screws as shown.
-
For a hung window, attach the air outlet adapter onto the exhaust hose and rotate it 90° to secure it in place. For a sliding window, attach the exhaust adapter onto the exhaust hose.
-
For a hung window, attach the air outlet adapter onto the window slider kit. For a sliding window, attach the exhaust adapter onto the window slider kit.
CONTROL PANEL
DISPLAY ICONS
Wireless feature (Wi-Fi enabled models only)
Illuminates to show wireless connection is activated.
The timer on/off indicator light
Press and hold on TIMER button for 3 seconds to cancel timing function.
Operation Mode Indicator Lights
Illuminates to show current mode operation.
LED Display
Shows the set temperature in °For °C and the Auto-timer settings. While on FAN
modes, it shows the room temperature.
Fan Speed Indicator Lights
Illuminates to show the set fan speed.
Sleep Indicator Light
Illuminates when Sleep Mode is activated.
Filter Indicator Light?
The LED will illuminate after 250 hours of operation. This feature is a
reminder to clean the Air Filter for more efficient operation.
CONTROL BUTTONS
Swing/Wireless Mode
Auto-swing
Press to start the auto swing feature. When the operation is ON, press the
SWING button to stop the louver at a desired angle.
Turn on Wireless connection mode
To turn on Wireless connection mode on, press and hold the swing button for 3
seconds and the LED display will show “AP” for 3 seconds. Follow the
instructions on the Wi-Fi setup manual and the latest app version available
for your phone operating system.
Turn off Wireless connection mode
Once the wireless connection mode is successful, press and hold the swing and
down buttons for 3 seconds and the LED display will show “OF” for 3 seconds.
Connection Successful
If the connection is successful within 8 minutes, the unit will exit wireless
connection mode automatically and the wireless indicator will illuminate.
Connection Failed
If the connection has failed within 8 minutes, the unit will exit Wireless
connection mode automatically.
NOTE: When you restart the wireless functions, it will take a period of
time to connect to the network automatically. Always be sure your wireless
connection is working properly and there is a valid internet connection for
Wi-Fi functionality to work.
Timmer
Press to program timer delayed switch ON or OFF function.
Modes
Press to change modes. Controls the functions modes: AUTO, COOL, DRY, FAN, and
HEAT.
*only for ARC-1230WNH
CONTROL BUTTONS
Up and Down buttons
Adjusts set temperature 1 °F I 1 °C increments or timer hours (O – 24 hours).
NOTE: This unit is capable of displaying set temperature in Fahrenheit or
Celsius. To convert from one to another, press and hold the Up and Down
buttons for 3 seconds.
Fan
Press to change fan speed. Controls the 5 fan speeds and mode: Continuous,
Auto, Low, Medium, and High.
NOTE: In Auto and Dry mode, the fan speed control is disabled Continuous
Fan Mode. Press and hold to select continuous fan speed. The fan speed will
keep on operating in a continuous speed based on the last fan speed setting.
Sleep Mode
Press to activate Sleep mode. Press SLEEP button again to stop the sleep
operation.
NOTE: This feature is not available in FAN or DRY mode.
Filter
Press SLEEP button for 3 seconds to clear the clean filter light reminder.
Power
Press to turn the air conditioner on and off.
ERROR CODES
El – Room temperature sensor error
Unplug unit and restart in 5 minutes
E2 – Evaporator sensor error
Unplug unit and restart in 5 minutes
E3 – Condenser sensor error
Unplug unit and restart in 5 minutes
E4 – Display panel sensor error
Unplug unit and restart in 5 minutes
Pl – Water reservoir full
Drain water from the unit
OPERATION INSTRUCTION
BEFORE USING YOUR APPLIANCE
- Remove the exterior and interior packing
- Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the
control panel or the ON/OFF button on the remote control
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To
activate this function mode, press the MODE button until the COOL indicator
light comes on. When the cooling mode is set, the compressor will start in
approximately 3 minutes. In cooling mode, hot air is exhausted from the
outdoor exhaust port and the exhaust hose must be connected to exhaust out the
hot air.
The temperature setting range of this air conditioner is from 60°F / 16°C to
86°F / 30°C. To set the temperature, press the + or – buttons. This air
conditioner has a 5°F temperature cushion which if the set temperature is
within 5°F of the ambient temperature, the unit runs on fan only mode. This
saves energy and prolongs the life of the compressor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in
noise level between the fan speeds is not very no ticeable when the
compressor is on. Try setting the unit to Fan only mode, you should be able to
hear the difference between high and low fan speed settings.
DRY (DEHUMIDIFYING) ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor
will activate intermittently depending on the ambient temperature and the fan
speed is set to LOW. To activate this function mode, press the MODE button
until the DRY indicator light is displayed. Please note that when switching
function mode, there will be an approximately 3 minute transition time. In
dehumidifying mode, the exhaust hose does not need to be vented. If the
exhaust hose is vented, the room will be cooled as it dehumidifies. To
prevent cooling, remove the exhaust hose from the window kit and allow the
warm air from the rear to be re-circulated into the room. If room temperature
is higher than 77°F, the fan speed can be adjusted. If room temperature is
lower than 77″F, the fan speed is set at low. NOTE: When using dehumidifying
mode, venting the exhaust hose to the outside is not required. If vented, the
warm air is exhaust ed to the outside and cooling within the room may occur.
Additionally, if the exhaust hose is not vented, the unit may require more
frequent draining. Also, the air conditioner does not have a humidistat in
which a specific humidity level can be set.
AUTOMATIC MODE
When you set the air conditioner in AUTO mode, it will automatically select
cooling, heating, or fan-only operation depending on what temperature you
have selected and the room temperature. The air conditioner will control the
room temperature automatically around the set temperature selected. The fan
speed is automatically selected and cannot be changed. To operate the unit in
Auto mode when the unit is on, press the mode button until the Auto indicator
light comes on ARC-1230WNH model only.
HEAT MODE (*only for ARC-1230WNH)
This air conditioner operates on the heat-pump principle, absorbing heat from
air outdoors and transferring that heat to the indoor unit. In this mode, the
air conditioner heats the room. To activate this function mode, press the MODE
button until the HEAT indicator display comes on. When the heating mode is
set, the compressor will start in approximately 3-5 minutes. The heating
temperature setting range of this air conditioner is from 60°F -86°F / 16°C
-30°C. To set the temperature, press the UP and DOWN buttons. To set the fan
speed, press the FAN button.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air
in the room. To activate this function mode, press the MODE button until the
FAN indicator light comes on. In this function mode, the temperature cannot be
set. Subsequently, set the desired fan speed by pressing the FAN button. When
using FAN only mode, venting the exhaust hose to the outside is optional.
TIMER (DELAYED SWITCH ON/ OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the
air conditioner. The time (hours) delay can be set, enabled and disabled.
SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the TIMER
button. The TIMER OFF light will come on. Then set the desired time delay OFF
hours by pressing the UP and DOWN buttons. The time increments are at 0.5
hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the
delay time set has elapsed, the air conditioner switches off. To cancel the
delayed switch off function, turn off the air conditioner or adjust the time
set-ting to 0.0.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the TIMER button. The TIMER ON light
will come on. Then set the desired time delay ON hours by pressing the UP and
DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, fol-
lowed by 1 hour increment up to 24 hours. When the delay time set has elapsed,
the air conditioner switches on. To cancel the delayed switch on function,
turn on the air conditioner or adjust the time setting to 0.0.
SENSE FUNCTION
The remote control serves as a remote thermostat allowing for the precise and
comfortable temperature control. With this technology, an efficient
temperature sensor is integrated in the remote control. To activate the I
SENSE function, press I SENSE button on the remote control. Once this
function is activated, the remote control will send the temperature signal to
the air conditioner every 3 minutes interval until you press the I SENSE
button again. The air conditioner will automatically cancel the I SENSE
feature if it does not receive the signal during any 7 minutes interval.
NOTE: The I SENSE feature is not available in DRY and FAN mode. Shifting
the operating mode or turning off the unit will cancel the Follow Me feature
automatically. The remote control needs to be within 26 feet reach of the
indoor unit for the I SENSE mode to work appropriately.
SLEEP MODE*
In this mode, the air conditioner gradually increases the set temperature in
cooling mode or decreases the set temperature in heating mode. It decreases
the noise level and conserves energy. In cooling mode, the set temperature is
increased by 2°F/ 1°C in the first 30 minutes. The temperature will then
increases by another 2°F/ 1°C after an additional 30 minutes. For models with
heat mode, the set temperature is decreased by 2°F/ 1°C in the first 30
minutes. The temperature will then decreases by another 2°F/ 1°C after an
additional 30 minutes. This new temperature will remain the same for 7 hours.
To activate this function mode, press the SLEEP button until the SLEEP
indicator light comes on.
NOTE:* This feature is not available in FAN or DRY modes.
ARC-1230WNH model only
AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously
set function mode and settings when power is restored.
CONTROLLING THE AIR FLOW DIRECTION
The louvers can be controlled to Auto-Swing or in a fixed direction. To
control the air flow direction by Auto-Swing, press the SWING button. To set
the louvers in a fixed angle or direction, press SWING button while on Auto-
Swing mode when desired angle is chosen.
CLEAN FILTER REMINDER
The FILTER light on the display will illuminate after 250 working hours as a
reminder to clean the filter for a more efficient operation.
After cleaning the filter, press the SLEEP button for 3 seconds to clear the
clean filter reminder light.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The
sounds listed below are normal. Noise reflecting off hard surfaces such as a
floor or wall can make sounds seem louder than they actually are.
- The compressor may make a pulsating or high-pitched sound
- Water running from the evaporator to the water tank may make a splashing sound
- Refrigerant flowing may make a gurgling sound
- Fan sound may come from front and back air vents
COMPRESSOR LOCK OUT
This portable air conditioner is optimized to operate in an ambient
temperature of 64°F – 90°F. The compressor circuit has an automatic 3 minute
time delayed start if the unit is turned off and on quickly. This prevents
over-heating of the compressor and possible circuit breaker tripping.
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control. To
transmit signals from the remote control to the air conditioner, point the
front part of the remote handset towards the control panel on the air
conditioner. Reception of the signal is confirmed by a beep. The maximum
signal transmission distance is approximately 8 meters/ 26 feet.
NOTE:
- Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences
- Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner
- Remove the batteries if the remote control is not used for long periods
1| Mode indicator| Displays the current selected mode (Auto, Cool, Dry, Heat
or Fan)
---|---|---
2| Wireless indicator| Displays when the remote is turned on, and disappears
when it is turned off
3| Timer On indicator| Displays when TIMER ON is set
4| Timer Off indicator| Displays when TIMER OFF is set
5| Swing indicator| Displays auto-swing feature is turned, and disappears when
it is turned off
6| Temperature/Timer display (h)| Displays the set temperature or timer
setting when using ON/ OFF functions “h (hours)” indicator is shown when timer
settings are activated
7| Remote Control indicator| Displays when the remote is turned on and
disappears when it is turned off
8| Temperature Scale indicator| Displays temperature scale Fahrenheit or
Celsius
9| Lock settings indicator| Indicated all the current settings are locked
10| Sleep Feature indicator| Displays when SLEEP function is activated
11| I Sense Feature indicator| Displays when I SENSE function is activated
12| Fan Speed indicator| Displays the current selected fan speed
13| Up button| Increases set temperature/time
14| Down button| Decreases set temperature/time
15| Mode button| Controls the function modes: Auto, Cool, Dry, Heat and Fan
*only for ARC-1230WNH
16| Power button| Turns the unit On and Off
17| Fan Speed button| Controls the fan speeds: Auto, High, Medium, or Low
(Continuous mode cannot be set using the remote control)
18| Swing Feature button| Press to stop or start louver auto-swing feature
19| Sleep Feature button| Starts or stops louver movement and set louver angle
20| Timer ON button| Enables the Timer On
21| I Sense Feature button| Press to initiate I SENSE feature
22| Lock settings button| Press I SENSE and TIMER OFF buttons to lock current
settings
23| Timer OFF button| Enables the Timer Off
24| LED Display button| Press this button to turn on and turn off the display
on the indoor unit
25| Temperature Scale button| Press to change Temperature Scale (Fahrenheit I
Celsius)
REPLACING THE REMOTE BATTERIES
This remote control comes with two AAA batteries. Place the batteries in the
remote control before use.
- Slide the back cover from the remote downward to expose the battery compartment.
- Insert the batteries, ensure to match the(+) and ( ) symbols on the ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
Notes:
- The air conditioner will not respond if curtains, doors or other materials block the signal from the remote control to the unit.
- Prevent any liquid from contact with the remote control. Do not expose the remote control to direct sunlight or heat.
- If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
- Do not mix old and new batteries or batteries of different types .
- Do not leave the batteries in the remote control if it is not going to be used for more than two months.
CARE AND MAINTENANCE
SAFETY PRECAUTIONS
- Always unplug the unit before cleaning or servicing.
- DO NOT use flammable liquids or chemicals to clean the unit.
- DO NOT wash the unit under running water. Doing so causes electrical danger.
- DO NOT operate the portable air conditioner if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord. Contact Whynter Customer Support for more information.
WATER DRAINAGE
When the internal drain pan becomes full the appliance will beep 8 times and
the digital display will show error code Pl. The air conditioning or
dehumidifying action will stop but the fan may continue to operate. Ensure
that the appliance is turned off and unplugged and that it is close to a
floor drain before setting up any drain option.
A. Drain Plug
Remove the drain plug and allow the water to completely drain. Replace the
bottom drain plug, pressing firmly to ensure a tight fit and no leaks.
B. Continuous Gravity Drain
During dry mode, install continuous drain option so that the appliance will
automatically drain collected water. Remove the upper drain plug and attach
the drain hose that was provided with the appliance. Place the open end of the
drain hose over the receptacle that the appliance will drain into; this could
be a basement floor drain, a sink or similar.
Ensure that there are no kinks or bends in the drain hose and that it goes
straight down toward the floor. The continuous drain is activated by gravity
only. If the hose is not positioned directly downwards, water will not drain
correctly.
C. Heat pump drainage (for ARC-1230WNH only)
This unit has a condensate pump feature that can pump out (and up) water
through the included drain hose for continuous water removal during HEAT Mode.
Remove the heat pump drain plug from the back of the unit and install the
drain hose. Place the open end of the hose to a drain area.
NOTE: The condensate pump will only engage during Heat mode and will not work
in any other modes. Pump drain hose is required to be installed when using the
portable air conditioner in Heat Mode.
NOTE: To reduce pump drain noise, make sure to attach the drain hose adaptor
to the open end of the drain hose. To secure the adaptor in place, use the
provided zip tie.
UNIT CLEANING
CLEANING
- Unplug the appliance before cleaning or servicing.
- Clean the cabinet with a lukewarm damp cloth and neutral detergent. Dry the cabinet with a lint-free dry cloth.
- Do not use gasoline, paint thinner or other chemicals to clean the appliance.
- Do not wash the appliance directly under a tap or using a hose. It may cause electrical damage.
AIR FILTER
The air filter should be cleaned every two weeks to ensure efficient
performance. In households with animals, the air filter may need to be cleaned
more often and the external grills may need to be wiped to prevent blocked air
flow.
To access the filter:
- Switch off the air conditioner.
- Hold the exhaust hose, push it backward slightly and then lift it up.
- Remove the filter from the unit.
- Use a vacuum cleaner or tap lightly to remove loose dust and dirt.
- Rinse the filter thoroughly under warm running water (no hotter than 100 °F.)
- Dry thoroughly before re-inserting the filter.
LONG-TERM STORAGE
- Drain all water from the appliance.
- Run the appliance on Fan mode for half a day in a warm room to dry the inside of the appliance and prevent mold formation.
- Turn off the appliance and unplug it, wrap the cord and bundle it with tape.
- Remove the batteries from the remote control.
- Clean the air filter and reinstall it.
- Store the appliance in a cool, dark place. Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of the appliance.
DISPOSAL
This appliance should not be treated as regular household waste. Check for
local regulatory compliance regarding the approved and safe disposal of this
appliance.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSES | SOLUTIONS |
---|---|---|
The portable air conditioner does not turn on | • Power failure / outage |
• The automatic switch, line fuse, or breaker has been tripped
• The power supply voltage is too low
• The power cord is damaged
• The L.C.D.I. power plug for the unit is tripped
• The internal water reservoir is full and ‘P1″ appears on display| • Restore
the power supply
• Flip the switch / change the fuse /turn the breaker back on. Also note that
you may have too many applianc-es drawing power on one circuit, you may need
to move the other applianc- es to another circuit
• Move the unit onto another circuit with the correct voltage
• Call for service. Only authorized personnel should replace damaged power
cord or power plug
• Press the Reset button on the L.C.D.I. power plug
• Drain water from the air conditioner
• Possible loose internal connection.
• Please contact Whynter for service.
The unit turns on but the compressor does not turn on (the fan runs but the
unit is not cooling)| • The room temperature is outside of the operational
tolerances of the unit
• The Cooling mode is not on
• The compressor has not turned on yet because of its time delay
• The set temperature is too high
• The internal water reservoir is full and ‘P1″ appears on display| • This
unit is designed to work in ambient temperatures of 63°F to 90°F.
• Press the MODE button until the COOL light is shown on the display.
• Give the compressor 3 minutes to turn on after the Cooling mode has been
selected.
• Set the air conditioner to a lower temperature.
• It is recommended to set the temperature to at least 5°F of the ambient
temperature.
• Either manually drain the water by removing the drain plug or allow the unit
to exhaust the water itself by running the fan only mode. Then cooling will
resume.
• Possible loose internal connection.
• Please contact Whynter for service.
The air coming out of the unit is not very cold, or the airflow volume is
weak| • The filter is dirty or obstructed
• The air intake or exhaust is obstructed
• The unit is set in DRY or FAN mode
• The unit is set to low fan speed| • Clean the air filter
• Make sure there is at least 20″ of clearance from the air intake. Make the
length of the exhaust hose is as short as possible
• Set the unit to the cooling mode
• Set the unit to a higher fan speed
Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department.
PROBLEM | POSSIBLE CAUSES | SOLUTIONS |
---|---|---|
The unit has worked for a long time, but the room is not cold enough | • |
Windows or doors are open
• There are too many people in the room
• There is direct sunshine into the room
• The room is a kitchen or with many heat producing appliances
• There is a server in the room
• The room is too large| • Close all windows and doors
• You may need additional cooling or another air conditioner.
• Close curtains or blinds and try to minimize the amount of direct sun-light
into the room.
• You may need additional cooling or another air conditioner.
The unit is very noisy| • The unit is not level
• The surface underneath the unit is uneven
• Low power voltage| • Make sure the unit is on hard, level and stable
surface.
• Move the unit to a location with a level and hard floor.
• Make sure the wall outlet and support the required power consumption of the
air conditioner and do not use an extension cord.
The unit leaks water| • The unit is tilted or not leveled
• The water tank is full| • Make use the unit is leveled
• Drain water from the drain plug at the back of the air conditioner
Fan speed cannot be changed| • Fan speed differences are not very noticeable|
• The fan speed difference is not very noticeable when the compressor is on.
Try setting the unit to Fan only mode, you should be able to hear the
difference between high and low fan speed settings.
WARRANTY
ONE VEAR LIMITED PARTS WARRANTY
THREE VEAR WARRANTY ON COMPRESSOR
This WHYNTER product is warranted to the original owner, purchased from an
authorized Whynter dealer within the 48 U.S. continental states, for one year
from the original purchase date against defects in material and work manship
under normal residential usage. Should your WHYNTER product prove defective
within one year from the date of purchase, contact Whynter’s Customer Support
team with the serial number and proof of purchase to make a warranty claim. A
Return Authorization number must be issued before returning any parts or
products. Parts or products received without a Whynter issued Return
Authorization number will be refused. Under this warranty, Whynter will repair
or replace any parts found defective with new or remanufactured parts or ex
change the defective product with a new, refurbished, or remanufactured
product at our discretion. All defective products and parts covered by this
warranty will be repaired or replaced on a mail-in basis to Whynter’s Service
Center. This warranty is not transferable. After the expiration of the
warranty, the cost of labor and parts will be the responsibility of the
original owner.
After two months to one year, the customer will be responsible for the return
freight cost to Whynter’s Service Center. Please package the product carefully
in its original packaging to avoid damage in transit. Whynter is not
responsible for damage resulting from shipper mishandling or improper
packaging. Please retain the original box and packaging materials.
THIS WARRANTY DOES NOT COVER:
- Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
- Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.
- Use in commercial or industrial applications.
- Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material or workmanship.
- Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special handling provisions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
- Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
- Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.
- Products sold AS IS or from an unauthorized reseller.
- Products that have had their serial numbers removed or defaced.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PUR POSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED
BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL
EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY
IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLU SION OR
LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON THE
DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT
APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
To obtain service or information, contact
Whynter LLC via email at support@whynter.com or
call
866-WHYNTER.
Product contents and specifications may change without notice.
Copyright© 2021
WWW.WHYNTER.COM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>