ICUIXIAM 4×4 HDMI Rackmount Matrix Switch User Manual
- June 14, 2024
- ICUIXIAM
Table of Contents
- matters needing attention
- Packing list
- Product profile
- The HD Series 4K HDMI Ultra HD matrix is a professional device designed
- Schematic diagram of wiring
- front pane
- 1
- liquid crystal display (LCD) 。
- 2
- power light 。
- 3
- The IR IR reception window。
- 4
- working station indicator 。
- 5
- Choose knob。
- 6
- Front panel button。
- **Interface
- 1
- LAN interface。
- 2
- RJ45 serial port control input port.
- 3
- RS-232 serial port control input port, DB9 pin master connector
- 4
- RS-232 serial port control output port, DB9 pin male connector
- 5
- The HDMI output interface.
- 6
- The HDMI input interface.
- 7
- AC 110-220V 50 / 60Hz power interface.
- Control interface description
- The RS232 control interface description
- The matrix switch provides a 2-way RS-232 serial interface(oneDB9master
- foot position
- definition
- instruction
- 1
- –
- –
- 2
- TX
- RS-232 protocol with, sending data
- 3
- RX
- RS-232 protocol is used, received data
- 5
- GND
- Signal ground
- other
- –
- –
- foot position
- definition
- instruction
- 1
- –
- –
- 2
- TX
- RS-232 protocol with, sending data
- 3
- RX
- RS-232 protocol is used, received data
- 5
- GND
- Signal ground
- other
- –
- –
- foot position
- definition
- instruction
- 1
- TX
- RS-232 protocol with, sending data
- 2
- RX
- RS-232 protocol is used, received data
- 5
- GND
- Signal ground
- other
- –
- –
- Case appearance
- Note: The quantity of equipment interfaces shall be subject to the
- Case size Matrix Dimensions:
- type
- The front panel is long A(mm)
- Case height B(mm)
- Case depth C(mm)
- The back width D(mm)
- 1U
- 483
- 47
- 192
- 440
- 2U
- 483
- 89
- 265
- 440
- equipment installation
- When installing the equipment, try to avoid strong smooth light and
- The rear panel of HD matrix series provides two standard RS232
- A standard 220V power supply cord is standard in the matrix package. Use
- Key operation instructions
- Description of the front panel keys
- Press “ESC” in the front panel in any state to return to the upper level
- In the standby state, press the front panel button “MENU” to enter the
- In the standby state, press the “CALL” button in the front panel to
- The most commonly used buttons, selection functions and determining
- Used to select all output channels during signal switching.
- In any interface, press the “LOCK”, the panel button is disabled, the
- For “signal switching”, enter the signal switching interface by clicking
- For switching between the left and right direction of the option
- How to switch channels
- For “signal switching”, enter the signal switching interface by clicking
- **Remote control instructions
- WEB Web page operation instructions
- technical parameter
- Serial communication protocol
- Common faults and maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- Pin description for the RS-232 IN port DB9 master connector:
- Prescription for the RS-232 OUT port DB9 connector:
- RJ45 serial port input pin description:
- IP is the network port
- 1U front panel
- 1U Interface
- 2U front panel
- 2U Interface
- Installation environment
- **Signal connection
- RS232 Communication interface connection
- Power connection
- Standby screen
- MENU menu button
- CALL function key
- OK function key
- ALL function key
- LOCK function key
- IN/OUT function key
- Knob function
ICUIXIAM 4×4 HDMI Rackmount Matrix Switch User Manual
matters needing attention
kindly reminder:
For the safety of your device and the equipment, you must readthesafety
instructions carefully before using the device. If you encounter questions
during the use process, please read this instruction manual first. There is a
detailed description of the equipment operation in the text. If you still have
questions, please contact us, and we will give you satisfactory reply as soon
as possible。
This specification is subject to version change without notice, please understand。
The Company reserves all rights to the product
Packing list
project | name | quantity | Company |
---|---|---|---|
1 | The HDMI Matrix Host | 1 | Platform |
2 | The 220V power cord | 1 | root |
3 | Quick entry | 1 | book |
4 | DB9 pin to RJ45 conversion head (mother-mother) | 1 | individual |
5 | parvicostellae | 1 | strip |
Product profile
The HD Series 4K HDMI Ultra HD matrix is a professional device designed
for ultra-high resolution HDMI digital signal switching, which can assign multiple-input HDMI signals to multiple display terminals. Support for HDMI1.4a standard, support for EDID management; resolution up to 4K@30HZ, 1080@120HZ. The whole machine adopts an integrated structure, supporting the computer, mobile phone, tablet, button, serial port, WEB and other control methods, widely used in high-definition visual conference, radio and television engineering, multimedia conference hall, large screen display engineering, TV teaching, command and control center and other places.
Schematic diagram of wiring
front pane
1
|
liquid crystal display (LCD) 。
---|---
2
|
power light 。
3
|
The IR IR reception window。
4
|
working station indicator 。
5
|
Choose knob。
6
|
Front panel button。
**Interface
**
1
|
LAN interface。
---|---
2
|
RJ45 serial port control input port.
3
|
RS-232 serial port control input port, DB9 pin master connector
4
|
RS-232 serial port control output port, DB9 pin male connector
5
|
The HDMI output interface.
6
|
The HDMI input interface.
7
|
AC 110-220V 50 / 60Hz power interface.
Control interface description
The RS232 control interface description
The matrix switch provides a 2-way RS-232 serial interface(oneDB9master
connector, one DB9 male connector), through which thematrixcanbe controlled。
-
Pin description for the RS-232 IN port DB9 master connector:
foot position
|
definition
|
instruction
---|---|---
1
|
–
|
–
2
|
TX
|
RS-232 protocol with, sending data
3
|
RX
|
RS-232 protocol is used, received data
5
|
GND
|
Signal ground
other
|
–
|
–
-
Prescription for the RS-232 OUT port DB9 connector:
foot position
|
definition
|
instruction
---|---|---
1
|
–
|
–
2
|
TX
|
RS-232 protocol with, sending data
3
|
RX
|
RS-232 protocol is used, received data
5
|
GND
|
Signal ground
other
|
–
|
–
-
RJ45 serial port input pin description:
foot position
|
definition
|
instruction
---|---|---
1
|
TX
|
RS-232 protocol with, sending data
2
|
RX
|
RS-232 protocol is used, received data
5
|
GND
|
Signal ground
other
|
–
|
–
-
IP is the network port
Case appearance
-
1U front panel
-
1U Interface
-
2U front panel
-
2U Interface
Note: The quantity of equipment interfaces shall be subject to the
physical objects
Case size Matrix Dimensions:
type
|
The front panel is long A(mm)
|
Case height B(mm)
|
Case depth C(mm)
|
The back width D(mm)
---|---|---|---|---
1U
|
483
|
47
|
192
|
440
2U
|
483
|
89
|
265
|
440
equipment installation
-
Installation environment
When installing the equipment, try to avoid strong smooth light and
backlight scenes. Please keep the ambient light well lit。
-
**Signal connection
** The interface of HD matrix series is divided into signal input and output interface, INPUT is signal input terminal, and OUTPUT is signal output terminal. Please use the corresponding cable to connect the input and output equipment, connect the output terminal of the signal source (such as DVD machine, computer, etc.) to the matrix input terminal (INPUT), and connect the matrix output (OUTPUT) to the input interface of the signal use equipment (such as LCD screen, projector, TV, etc.).
-
RS232 Communication interface connection
The rear panel of HD matrix series provides two standard RS232
communication interfaces, one RS232 IN, connected to the computer or another matrix RS232 OUT. The RS232 interfaces of multiple matrix can be connected, and only the RS232 interface of one computer is used to control and set the multiple matrix; connect the RS-232 serial communication port to the RS-232 communication port of the HDMI matrix host. After installing the control software, the computer can control the matrix. Users can use the software included with the matrix as the computer control software or write the own control software for detailed instructions of the user manual control commands. Special attention: When the matrix RS-232 port is connected to the computer or the central control, pay attention to the line order of TXD and RXD, in detail, considering the pin definition of the other device
-
Power connection
A standard 220V power supply cord is standard in the matrix package. Use
the parent end of the power cord for the matrix connection marked with AC220V50/60HZ on the back of the matrix, and the male end is connected to the 220V 50/60HZ AC power supply. To ensure the safety and normal operation of the equipment, please note that the single-phase three-line AC power supply with protected ground must be used.
Key operation instructions
Description of the front panel keys
-
Standby screen
Press “ESC” in the front panel in any state to return to the upper level
interface (with an exception to the standby interface).
-
MENU menu button
In the standby state, press the front panel button “MENU” to enter the
main menu page, under which you can select signal switching, plan call, common functions, and system setting.
-
CALL function key
In the standby state, press the “CALL” button in the front panel to
enter the plan management menu, in which the scenario saving and scenario call functions can be performed.
-
OK function key
The most commonly used buttons, selection functions and determining
changes are determined by pressing “OK”
-
ALL function key
Used to select all output channels during signal switching.
-
LOCK function key
In any interface, press the “LOCK”, the panel button is disabled, the
second press “unlock”, “lock” state when the button produces green light.
-
IN/OUT function key
For “signal switching”, enter the signal switching interface by clicking
the IN/OUT button at any interface, or make input and output channel selection after selecting the signal switch in the main menu. (Press 0″ before entering single digits)
-
Knob function
For switching between the left and right direction of the option
selection interface, clockwise rotation is equivalent to counterclockwise rotation is equivalent to the knob has the “ok” button function, and the vertical panel presses the knob.
How to switch channels
For “signal switching”, enter the signal switching interface by clicking
the IN/OUT button at any interface, or make input and output channel selection after selecting the signal switch in the main menu. (Press 0″ before entering single digits)
**Remote control instructions
**
key | explain |
---|---|
close | Open / turn off the screen |
ALL | Select all outputs |
MODE | Plan mode |
IN | input select |
OUT | Output selection |
Upper / right / bottom / left | direction key |
OK | Confirm the key |
0…9 | digital input |
return | Go back to the next level |
WEB Web page operation instructions
How to log on the WEB page
- View the WEB Card IP
The device starts up in about 30 seconds:
192.168.1.182
HDMI Ultra high definition matrix
IP:192.168.1.182
- Access and Login
Access the device after the connection
parameter | instruction |
---|---|
IP address | The default ip is: 192.168.1.182(About 30 seconds after |
start, with two buzzer sounds, matrix LCD displays the ip address) 。
user name| The default user name is: admin.
---|---
password| The default password is admin。
Login| The default user name is: admin.
visit| Connect the access server (mobile phone, computer, or tablet) and
the device to an offline LAN, open the browser, and access the ip.
Matrix configuration
The number of input and output paths of the configuration matrix
Select the matrix settings:
parameter | instruction |
---|---|
Matrix Settings | Pull-down selects the number of input-output channels with a |
maximum value of 32.
buzzer| Turn the device buzzer on or off.
---|---
locking press button| Lock / Unlock the device keys.
language| Chinese / English switch.
software function| Turn the appropriate functional options on or off.(Top
right corner)
Software name| The Web name change.(Top left corner)
Note: After changing the unified configuration, click the corresponding
setting button to save the changes.
Split setting
Select Split Settings:
parameter | instruction |
---|---|
Splicing specifications | **Set up the display wall splicing |
specifications. The maximum value can be set to 10
---|---
Screen protocol| A variety of splicing screen protocols for users to choose
from
Independent display| Set the number of devices displayed independently, with a
maximum value of 12
Independent display switch| Open / close the independent display settings, and
then configure the independent display mapping.(Default is off)
Output mappings itch| Turn output mapping settings on / off and configure out
put mapping.(Default is off)
Output mapping| Change the display device and output interface mapping
relationship, the maximum value and the number of output channels set by the
matrix
Reset the button| Reset the output mapping relationship, and set it to the
defaulting-to-one mapping relationship
Note:** After changing the unified configuration, click the corresponding
setting button to save the changes。
Splicing control surface
How to control the big screen
- Splice / single screen screen: Select the input channel, select the screen, and click splice /
- Switch signal: single screen The selected screen can selected screen drags the signal to the screen or the double-click the input channel
Control instructions:
parameter | instruction |
---|---|
one-for-one | Switch the input channel signal “one to one” to the output |
channel.
A pair of all| Select the input source and click “pair All” to switch the
selected input source to all output channels.
empty| Empty the signal and clear the display wall.
Open / turn off the screen| Control the splicing screen to open / off the
screen.
Open / turn off the screen| Change the output signal type with three types:
HDMI, VGA and DVI.
Single screen| Select the display wall area to be changed and click the button
to make the splicing screen switch between “splicing” and “single screen”.
montage
Displays the wall area| Click the right mouse button in the display wall area
selected in the box to perform the function of “splicing, single screen,
empty”.
input source
| Four ways to switch the signal:one. Click the corresponding input source and
then the mouse box to select the desired display wall area, and then click the
single screen or splicing.two. Left mouse button to drag the input source to a
single display. three. Select the desired display wall area, left mouse button
and drag the input source to the display wall.four. After selecting the input
source, click “one to one” or “one toall”.(Mobile terminal control steps are
consistent).
Protocol window| Real-time display of the splicing control interface to
achieve various functions required by the splicing screen / matrix
instructions.
Independent output| Select the input channel, and then click Independent Input
to make a signal switch.(Independent display is required in the software
settings).
Plan mode| Click the corresponding plan to call, provided the plan is not
empty; the number of call plans is 32.
Save the plan| Click Save as No. Several Plan to store the current input and
output correspondence and splicing mode; the number of plans can be set as32.
---|---
Show / hidethe number| Show or hide the number of the splicing screen by
clicking.
Pull down thearrow| Show or hide the lower window by clicking.
Channel switching
Switch introduction:
parameter | instruction |
---|---|
one-for-one | Switch the input channel signal “one to one” to the output |
channel.
A pair of all| Select the input channel and click “pair All” to switch the
input channel signal to all output channels.
Save the plan| Store the current input and output correspondence and
splicingmode, storing up to 32 plans.
---|---
Input channel| With the output use, click the input channel first, and then
click theoutput channel one by one.
output channel| With the input use, click the input channel first, and then
click theoutput channel.
Close all| Clear all the output channel signals.
inquiry| Read the input channels corresponding to all the output channels,
such as the number displayed in the upper right corner of each output channel,
which is the serial number of the input channel corresponding to the output
channel.
Call the scene:
parameter | instruction |
---|---|
Save the situation | Store the current input / output channel correspondence; |
up to 32 stores.
Call the situation| Call the saved situation.
Note: After opening the wheel patrol state, you need to stay at this
interface; refresh the web page or switch the interface to stop the wheel
patrol.
Channel rename
parameter | instruction |
---|---|
Input / output name | Customize the input / output channel name. |
Scene plan | Customize the preplan name. |
Clean the button | Clear all of the contents of the input boxes. |
load button | Load the names of manually changed input, output channels, and |
plans.
Save the button| Save changes.
system maintenance
parameter | instruction |
---|---|
Version information | WEB version: WEB-GO-1.3.1. (Subject to the actual |
conditions)Firmware version: Version 210924A.(Subject to the actual
conditions)
line configuration| You need to pay attention to the relationship between the
subnet mask and the ip address, and the port rate is consistent with the
device, providing a “30,60,90,120” milliseconds protocol interval selection.
technical parameter
Host model and technical parameters
model| 7100UHD-0404| 7100UHD-0808| 7100UHD-0816|
7100UHD-1616| 7100UHD-1632
---|---|---|---|---|---
Number of input
interfaces| 4| 8| 8| 16| 16
Number of output
interfaces| 4| 8| 16| 16| 32
Serial control
interface| RS-232,9-pin-master D-type interface and 9-pin-male D-type
interface; RJ45
interface
Porter rate with
agreement| Baud rate:9600,data bit:8 位, stop bit :1,No odd and even check bits
Serial control port structure| 9 Head D type interface:2=TX,3=RX,5=GND
9-pin D type interface:2=TX,3=RX,5=GND
System working
power supply| 100VAC~240VAC,50/60 Hz International adaptive power supply
Storage and operating temperature|
-20°C ~ +60°C,0℃-50℃
Case size | 1U | 1U | 2U | 2U | 2U |
---|---|---|---|---|---|
Product weight | 2.55kg | 4.35kg |
Case size
LWH| 440x192x47mm| 440x265x89mm
Overall dimension
LWH| 525x270x135mm| 515x335x150mm
Quality| 1 Annual free warranty, lifetime maintenance
Serial communication protocol
controls parameter
When using the serial port control, please set the port rateto9600,8-bit data bit, 1-bit stop bit, no check bit.
Communication Control Protocol
The following protocols support all models including04,08and16:
function | ASCII instruct | instruction |
---|---|---|
import [in] Switch to all outputs | [in]All. | Enter the channel number, |
All.”For example: switch the Route 2 input to all outputsCode: 2All.
import [in] Switch to the [out] output| [in]V[out].| The first [x1] road input
to the [x1] road output. For example: switch the second input to the third
outputCode: 2V3.
Input in switch to the outputout1,out2,out3…
| [in]V[out1,out2,…].| [in] Road input to [out1, out2, out3…] road output.For example: switch the number 2 input to 5,6,7 road outputCode: 2V5,6,7.
Close the [out] road output
| [out]$.| Close the [out] road output, out: All, and close all the outputFor
example: Close the output channel # 2Code: 2$.
Input output Channel one to one| All#.| Set to all channels for the one-to-one
corresponding output.
Save the situation| Save[x].| Save the current channel state to the [x] data
group.[x]=1-32。For example, save the current state as situation #
| | 1,The Code is the code ” Save1.”
---|---|---
Call the situation
|
Recall[x].
| Restore the [x] data group channel status to the current state. For example,
switch the current state to context-saved state. The Code is: Recall1.
The buzzer responds when the operation is turned off| /:Eloff;| The buzzer
responds when the operation is turned off
The buzzer responds with the operation turned on| /:Bellona;| The buzzer
responds with the operation turned-on
Common faults and maintenance
-
When the image of the peripheral display device connected to the matrix has heavy shadow, if the projector has heavy shadow, the projector may not be properly adjusted or the wire quality is not up to standard, the corresponding button of the projector should be adjusted or the wire is replaced.
-
When the color is lost or no video signal output, it may be poor audio and video interface contact.
-
When the serial port cannot control the matrix, check whether the communication port set by the control software corresponds to the serial port of the connected equipment; check whether the communication port of the computer is good.
-
There is no corresponding image output during the matrix switching:
-
Check the corresponding input for a signal.(Oscilloscope or multimeter is available for detection.) If there is no signal input, the input line may be broken or a loose connector, so replace the wiring;
-
Check the corresponding output for a signal.(Oscilloscope or
multimeter is available for detection.) If there is no signal output, the output line is broken or the connector is loose, and the wiring can be replaced; -
Check that the output port number coincides with the controlled port number.
If the POWER, the light is not on, and the LCD is not displayed, and the operation is not responsive, please check whether the power input of the device is in good contact
-
-
If the POWER, the light is not on, and the LCD is not displayed, and the operation is not responsive, please check whether the power input of the device is in good contact.
-
The output image is disturbed, and it is possible that the input and output equipment is not well grounded.
-
When you unplug and plug the audio and video interface, if there is obvious static electricity, the ground wire of the equipment may not be well grounded, please follow the correct method, otherwise it is easy to damage the host and shorten the life of the host.
-
The LCD display is normal, and the communication port has a return code, but no image output or no audio output:
- May be the audio and video interface is loose, it can be replaced;
- May be wiring short circuit, can be replaced;
- The wiring may be disconnected, so it can be replaced;
- When the matrix panel keys and communication port cannot be controlled, the main engine may be damaged, please send it to professionals for maintenance.
Note: The equipment is not suitable for non-professionals, and shall receive professional training or guidance.
Please read this manual carefully before using the equipment. It should be properly kept for later use.
Read User Manual Online (PDF format)