Akitas SL596 Handheld Cordless Vacuum Cleaner Instruction Manual

June 14, 2024
Akitas

Akitas SL596 Handheld Cordless Vacuum Cleaner

Akitas-SL596-Handheld-Cordless-Vacuum-Cleaner-product

ATTENTION

To help you use this product in correct way and protect you from unnecessary body injury and property loss, please read this instruction manual carefully before you use it.

  1. This product is for home use only; it’s not for commercial use!
  2. Please check carefully whether every part is in good condition upon opening the box, please do not use the product and contact dealer or service immediately if anything is found missing or broken.
  3. Please keep instruction manual, warranty card, invoice, package and so on for future use or storage or repair.
  4. Please make sure the local power (V) fall within power range that indicated on charger
  5. Charger shall be placed on dry surface, do not leave it unattended during charging
  6. Please hold the plug instead of cord to pull charger out from socket, cord shall stay away from heat sources, do not touch charger with wet hand
  7. This product is not a toy, please store this product far away from reach of children. Special attention shall be made when children is playing around
  8. Please never use this product to vacuum any liquid, heat temperature substance, very fine substance (E.g. sawdust, plaster powder, cement, ash, carbon powder), sharp substance (E.g. glass, staple), and hazardous substance (E.g. detergent, solvent), chemical substance (E.g. Acid, flammable substance (petrol, alcohol), Etc.
  9. Please cut off the power before you clean the product, please always use dry or slight wet soft cloth, do not use alcohol, benzene, Etc.
  10. This product can’t stand itself, please apply the product body onto holder.11
  11. Do not have the product immerged in the water, do not leave or use the product out of house!
  12. Please make sure all parts are assembled correctly. Do not use this product without filtration
  13. Do not try disassembling the battery, Do not place battery on metal surface or near heat sources, Do not put the battery in fire
  14. Do not try disassembling or repairing this products/charger yourself, please call professionals for any repair or replacement with original parts/unit
  15. Please make sure that products can no longer be used before you discard it, the battery pack must be removed from product for further safe recycle disposal
  16. This product cannot be used by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  17. This product is not for any professional and commercial use, any damage/consequence caused by improper use or use without following this instruction are not covered by warranty

Parts

Akitas-SL596-Handheld-Cordless-Vacuum-Cleaner-fig
\(1\)

TECHNICAL PARAMETERS

Cleaner parameter

  • Model name: cordless VAC
  • Model no.: enigma 596
  • Rated voltage: 29.6V
  • Battery: Li-ion 2000mAh
  • Product’s size: 265x220x1060mm

Charger parameter

  • Charger output : 35V–500mA
  • Charger input : 100-240V~50/60Hz
  • Max Power: 300W
  • Charging time: 4-5H
  •  Box size: 762x322x152MM

ACCESSORIES

Akitas-SL596-Handheld-Cordless-Vacuum-Cleaner-fig
\(2\)

Assembly instruction

Please carefully read “ATTENTION” before assembly :
Power off before any assembly or accessories replacement
This product can’t stand itself, please apply it onto holder
Assembly

  • Follow above illustration to insert one end of tube into motorized nozzle Insert the body to the other end of tube
  • Follow the illustration : Fix the holder onto wall by screw, apply the product onto holder

Lights indication

  • No. 1, 2, 3: Battery power indication, more lights on, more higher the power is
  • No.4: Dust blockage indication(only flash)
  • No.5, 6, 7 : Air performance indication, more lights on, more higher the air performance is

BATTERY CHARGING

  1. Connect with charging inlet which is at right side of cleaner body
  2. No. 1, 2, 3 lights keep flashing on during charging. When battery is fully charged, 3 lights keep on

Attention: The product must be power off during charging

  • Only within 0°C–45°C can charging be allowed, over heating or over cold could prolong the charging time or even damage the battery. Over- heating protection could function when it exceeds 50°C
  • Normal charging takes 4-5 hours, please charge fully and use the product until the battery is fully drained for 1-3 times when you initiate using it so that the battery can be fully activated.

USED AS STICK VACUUM CLEANERAkitas-SL596-Handheld-Cordless-Vacuum-
Cleaner-fig \(7\)

  1. Press the power button, move the product back and forward to start your cleaning
  2. Press the power button again to turn off the product
  3. Air performance button: Press it to adjust between economy-normal-Maximum mode
  • When battery is running low of power. the no. 1.2.3 lights could flash on for 3 seconds before all lights became off and the product switch off itself. To start charging, please wait 30 minutes firstly to cool down the battery
  • The motorized roller rolls in very high speed, to avoid damage to cleaning surface, do not stay cleaning in same spot too long
  • The motorized nozzle has over heating protect function which can cut off the power to nozzle when blockage or like hair twirling occurs. Please turn off the product, unblock and clean the nozzle. Do not use the product until it cools down

USED AS HANDHELD VACUUM CLEANER
Replace the tube and motorized nozzle with attached crevice or upholstry nozzle, use it as a handheld vacuum cleanerAkitas-SL596-Handheld-Cordless-
Vacuum-Cleaner-fig \(8\)

Clean and maintenance

Clean the dustbin
Attention:

  • Empty the dust upon it reach “MAX” indication on dustbin
  • Switch off the cleaner and detach tube and nozzles
  • Aiming the dustbin at garbage bin, push downwards the release button, gently sway the dustbin to empty the dust, then close back the dustbin bottom

Clean the incoming air filtration system
It’s suggested to clean incoming air filtration after every 4-6 times using of product

  1. Switch off the product, screw out the metal mesh as per above illustration, take out the hepa filter
  2. Clean the mesh and hepa filter
  3. Assemble back the hepa filter and metal mesh after cleaning, un-proper assembly of hepa or mesh could lead to air/dust leakage

Attention :
Metal mesh can be washed directly by water. Flip the hepa filter to clean off the dust, do not water wash the hepa filter unless it gets very dirty. Before assembling back the mesh and hepa filter, please make sure they are all dry(natural dry 24 hours)
Warning: Do NOT use the products without mesh and hepa filter
Clean the exhaust filter

  1. Switch off the product, press buttons at both side as per above illustration to take out exhaust filter
  2. Flip the hepa filter to clean off the dust, do not water wash the hepa filter unless it gets very dirty. Before assembling back hepa filter, please make sure it is all dry (natural dry 24 hours)
  3. Assemble back the exhaust filter

Clean the nozzle

  1. Switch off the product, detach the motorized brush
  2. Turn the button on the bottom of nozzle by coin to “unlock” position
  3. Lift up the roller and take it out
  4. Clean any dust and cut off twirled hair or blockage by scissors or knife
  5. Place back the cleaned roller and turn the button back to “lock” position

Problem Solving

Akitas-SL596-Handheld-Cordless-Vacuum-Cleaner-fig
\(13\)

1-Year Limited Warranty

enigma product is warranted to be free from defects in material and workmanship under normal use and service for one year from the date of the original purchase with the receipt. The manufacturer’s obligation shall be limited to repairing or replacing any part of the product that is defective. Such warranty shall not apply to damages resulting from accidents, abuse, or misuse. Warranty shall not applied to reduction in battery discharge time due to battery age or use.
DISPOSAL INFORMATION
enigma products are made from high grade recyclable materials. Please dispose of this product responsibly and recycle where possible.
*Please note that not all parts are recyclable. Recycling of parts is subject to the capabilities of 3rd party suppliers.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Akitas User Manuals

Related Manuals