Panasonic FV-15TGU6 Ventilating Fan Instruction Manual

June 14, 2024
Panasonic

Panasonic FV-15TGU6 Ventilating Fan

Product Information

  • Model: FV-15TGU6 / FV-20TGU6
  • Power Supply: AC 220 V (FV-15TGU6), AC 220-240 V (FV-20TGU6)
  • Frequency: 50 Hz
  • Air Direction : Not specified
  • Power Consumption: 10 W (FV-15TGU6), 19 W (FV-20TGU6)
  • Air Volume: 275 CMH (FV-15TGU6), 525 CMH (FV-20TGU6)
  • Weight: Not specified

Product Usage Instructions

  1. Before connecting the power supply, ensure that the unit is not disassembled for reconstruction.
  2. Never install this fan over cooking equipment.
  3. Install this fan in the ceiling only.
  4. Be sure to provide an appropriate ventilation opening.
  5. Mount the ventilating fan above 2.3m from the floor.
  6. If the ceiling is not strong enough, reinforce it before installing the product.
  7. Use a device for disconnection from the supply which has a contact separation of at least 3mm in all poles (switch), in accordance with local electrical wiring rules.
  8. Fix a wooden frame to the ceiling where the fan is installed.
  9. The wooden frame should form an Xmm square opening.
  10. Fix the frame at a minimum distance of 250mm from the ceiling and 100mm from the wall on any side.
  11. Install the fan body on the wooden frame using mounting screws.
  12. Secure the blade assembly and spinner to the motor.
  13. Connect the power cord to the power supply.
  14. Squeeze and insert the springs into the spring locking holes.
  15. Ensure that the fan is switched off before performing any accessory installation.

Please read these instructions carefully before attempting to install, operate or service the Ventilating Fan. Failure to comply with instructions could result injury and / or property damage. In that case the product shall not warrant them. Please retain this booklet for future reference.

SAFETY INSTRUCTIONS

  • Disconnect the power supply until blade is stationary before cleaning and maintenance.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or menta capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly aualified person in order to avoid a hazard.

The following explanations must always be observed in order to prevent harm to users or other people and prevent damage to property.

  • The following displays are classified and explained to what extent harm or damage occurs when the display details are ianored and the unit in auestion is wronalv used.
    Warning
    This indication means : Must be treated seriously that this may result in death or serious injury.
    Caution
    This indication means:Must be treated seriously that this may result in injury or physical damage.

  • The types of details to be observed are classified and explained in the following illustrated display. (Below are the series of illustrated displays)
    This type of pictorial symbol indicates a “Prohibited” action that must be avoided.
    This type of pictorial symbol indicates a “Compulsory” action that must be performed.

Warning

  • Before connecting the power supply, connect the earth grounding wire first.
  • Do not disassemble the unit for reconstruction It may cause fire or electric shock.
  • Use this fan at the rated voltage and frequency indicated on the name plate.
  • May cause fire or shorten the life of motor.

INSTALLATION CAUTIONS
Caution

  • Do not install this fan where it could be directly exposed to water or excess vapour.
  • Never install this fan over cooking equipment.
  • Do not connect air duct to the fan keep the air outlet clear
  • Install this fan in the ceiling only.
  • Be sure to provide an appropriate ventilation opening.
  • This ventilating fan should be mounted above 2.3m from the floor.
  • Product must be install on to the ceiling which is enough strong, if the ceiling is not enough strong it must be reinforced for it to be strong enough.
  • This fan should be installed so that the metal parts of the product and mounting screw do not contact any metallic members in the wall, such as metal laths, wire laths and metal plate, it is possible to cause fire harzards in case of leak.
  • Use a device for disconnection from the supply, having a contact separation of at least 3mm in all poles in accordance with wiring rule.
  • This fan must be installed by a qualified technician Otherwise, it is possible to be dropped down.

HOW TO INSTALL

**DIMENSIONS

**

Model A B C D E F G H
FV- 15TGU6 253 244 230 105 214 180 180 13
FV- 20TGU6 315 305 286 130 260 232 223 13

WIRING DIAGRAM

OPERATION

Switch
Connect the power cord to the ON/OFF switch and install the switch on the wall. SUPPLIED ACCESSORIES

No. Appearance Name Quantity
1 **** Mounting Screws 4
2 **** Louver 1
3 Operating Instructions 1
INSTALLATION STEPS
  • Open the wiring cover and take off the cord clip.

  • Connect the power cord according to the wiring diagram.

  • It must be connected with earth wire.(15-20mm longer than other lead wires.)

  • Replace the cord clip and the wiring cover Secure with the cord clip and screw provided.
    Note: In order to avoid the danders. it must be connected by qualified technician.

  • Make sure all connections are fastend firmly after wiring is finished.

  • The all connections should be accommodated in a suitable compartment.

  • Use a device for disconnection from the supply, which having a contact separation of at least 3mm in all poles (switch), which must be incorporated in the fixed wiring in accordance with the local electrical wiring rules.

  • Electrical wiring must be done according to the wiring diagram and local electrical wiring rules for fixed wiring.

  • Do not kink or pinch the supply wiring.
    Otherwise, it may cause electric leakage, electric shock or fire.

  1. Fix a wooden frame to the ceiling where the fan is installed.
  2. The wooden frame should form a Xmm square opening.
  3. Fix the frame at minimum distance 250mm from the ceiling and 100mm from the wall on any side.
  4. Install the fan body on the wooden frame by mounting screws.
  5. Secure the blade assembly and spinner to the motor.
  6. Connect the power cord to the power supply.
  7. Squeeze and insert the springs into the spring locking holes.

MAINTENANCE PRECAUTIONS

Caution

  • First, ensure that the fan is switched off.
  • Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
  • Do not allow water to contact electrical part such as motors or switches.
  • Do not immerse blade or other resin parts in hot water over 60°C.
  • When the product is to no longer be used, it must not be left in place but removed to prevent it from possibly dropping.
  • Wear plastic aloves durina cleanina mav avoid accidents.

SPECIFICATIONS

Model| Air direction| Voltage [V]| Frequency [Hz]| Power consumption [W]| Air Volume [CMH]| Weight
---|---|---|---|---|---|---
FV- 15TGU6| EX.| 220| 50| 10| 275| ***
FV- 20TGU6| EX.| 220| 50| 18| 520| 1.30
230| 19| 525
240| 20| 530

  • Insulation class E, Type of Insulation: Functional Insulation