LIVARNO IAN 402407_2204 Electric Stainless Steel Fitting With Integrated Instantaneous Water Heater Instruction Manual
- June 15, 2024
- LIVARNO
Table of Contents
LIVARNO IAN 402407_2204 Electric Stainless Steel Fitting With Integrated
Instantaneous Water Heater
Product Information
- Product Name: Electric Stainless Steel Fitting with Integrated Instantaneous Water Heater
- Model : LH-SH-1
- Brand : Not mentioned
- Product Type : Fitting with Water Heater
- Material : Stainless Steel
- Safety Features : Splash-proof (IPX4), Protection class I (requires a protective conductor connection), SGS tested safety label
Product Usage Instructions
Introduction :
- Read the installation and operating instructions carefully.
- Familiarize yourself with all the functions of the appliance by referring to the illustrations in the manual.
Intended Use:
The electric stainless steel fitting with integrated instantaneous water
heater is designed for use in various applications. It provides hot water
instantly and can be installed below or above the work surface.
Parts Description:
Refer to the illustrations provided in the manual for a detailed
description of the parts.
Technical Specifications:
The technical specifications are not mentioned in the provided text.
Scope of Supply:
The contents of the product package are not mentioned in the provided text.
Safety Instructions:
- Observe all warnings and safety instructions mentioned in the manual.
- The product is splash-proof (IPX4) and complies with protection class I.
- Dispose of the packaging and device in an environmentally friendly manner.
Assembly:
Follow the instructions provided for assembly below and above the work
surface.
Operation:
After assembly, follow the instructions for commissioning the product. – Set
the desired water temperature according to the instructions provided.
Cleaning and Maintenance :
Follow the standard note on maintaining and cleaning the fitting. – If
required, refer to the instructions for replacing the cartridge.
Troubleshooting:
Troubleshooting instructions are not mentioned in the provided text.
Disposal:
Dispose of the product packaging and device in an environmentally friendly
manner.
Information:
The manual provides information on the suitability of tap water for
drinking.
Warranty and service information are mentioned but not detailed in the provided text.
Note : This response is based on the given text-extract from the user manual. For complete and accurate information, it is recommended to refer to the original user manual provided with the product.
Before reading, fold out the two pages with the illustrations and then familiarise yourself with all the functions of the appliance.
Introduction
Key to pictograms used
Electric stainless steel fitting (LH-SH-1) with integrated instantaneous water heater
Introduction
Congratulations on your purchase of a new product. You have chosen a high-
quality product. The installa-tion/operating instructions are an integral part
of this product. Please read these installation/operating instructions in
their entirety before installation and observe the information they contain.
These instruc-tions contain important installation, adjust-ment and care
information. Keep the installation/operating instructions in a safe place and
pass them on to any subsequent owners.
Intended use
The product is a water-saving fitting intended exclusively for connection
to a cold water line and a power line for regulating and heating the water and
for installation on sink units. Make sure that the specifications for power
connection and water pressure (see “Technical specifications”) are followed.
The product is not suitable for central heating systems, instantaneous water
heaters, pressure boilers, low-pressure water heaters or other water heating
systems. It must not be connect-ed to these. If in doubt, please contact an
install-er or specialist consultant. Any use other than those described above
or modification of the product is not permitted and may result in dam-age.
Improper use can also result in potentially fatal hazards and injuries. The
product is intended for private use only, not for medical or commercial use.
The manufactur-er accepts no liability for damage caused by improper use.
DIMENSIONS
Parts description
- Aerator housing
- Aerator
- Aerator gasket Cartridge
- Cartridge housing
- Lock nut
- Screws
- Lever wheel
- Screw
- Hand lever
- Lever cover
- Fixing nut
- Cable guide rings (2x)
- Cable guide ring, white
- Cable guide ring, chrome
- Flexible connecting hose
- Power cable with mains plug
- Fitting body
- Display
- Fitting thread
- Filter
Technical specifications
- Model number : LH-SH-1
- Power supply: 220 – 240 V ~ AC voltage, 50/60 Hz
- Power consumption: 3400 W Protection class I Ingress protection rating IPX4
- Power connection: Socket with a 16 A fuse
- Cable : 1250 mm
- Connection flex. connecting hose: 3/8″ – 1/2″
- Flow rate : 2.5 l to 6 l (1.5 bar – 5 bar / 150 – 500 kPa)
- Max. water temperature : ~55 °C
- Minimum flow pressure: 1.5 bar
- Total weight: 1,165 g
Scope of supply
- Fitting
- Cable guide rings (2x), pre-assembled
- Mounting kit, pre-assembled
- Flexible connecting hose
- Power cable with mains plug, pre-assem-bled
- Installation/operating instructions
Safety instructions
KEEP ALL SAFETY INSTRUCTIONS AND MANUALS FOR FUTURE REFERENCE.
WARNING! RISK OF DEATH AND ACCIDENT FOR INFANTS AND CHILDREN!
Never leave children unattended with the packaging material. There is a risk of suffocation with packaging material. Children often underestimate the dangers. Always keep children away from the product. This product may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed in how to use the product safely, and are fully aware of the consequent risks of use. Children must not play with the product. Cleaning and user maintenance must not be carried out by children without supervision.
WARNING OF ELECTRIC SHOCK!
Leaks or escaping water can lead to a risk of fatal injury from electric shock. Carefully check all connections for leaks and make sure that all electrical equipment lines close to the sink unit are correctly and safely installed.
- The connection plug of the fitting must fit into the socket; the plug must not be changed in any way. Do not use adapter plugs. Unmodified plugs and matching sockets reduce the risk of electric shock.
- Avoid contact with earthed surfaces such as pipes, heaters, stoves and refrigerators. There is an increased risk of electric shock when your body is earthed.
- Never immerse the connecting cable and the fitting in water or other liquids and make sure that they do not fall into the water.
- Never touch the connecting cable with wet hands when it is connected to the mains power supply.
- Do not misuse the cable to pull the mains plug out of the socket or similar. Keep the cable away from heat, oil, sharp edges or moving parts. Damaged or entangled cables increase the risk of electric shock.
- If in doubt, consult a specialist.
- CAUTION! MATERIAL DAMAGE! Improper assembly and handling of the product can cause material damage. Have the installation carried out by a specialist.
- Switch off the water supply to your living spaces before installation.
- During installation, ensure that all seals are correctly positioned on the sealing surfac-es.
- Do not use the fitting on low-pressure and small electrical storage tanks or other water heating systems
- Only connect the fitting to cold water lines
- Only use the product at ambient tempera-tures above 0 °C.
- If there is a risk of frost, shut off the water supply and drain the fitting.
- Do not use the product if it shows signs of damage or its function is impaired.
- Leaks or escaping water can cause consid-erable material damage to the building or contents. Therefore, check all connections carefully for leaks.
- Before installation, familiarise yourself with all conditions on site, e.g. the existing water connections and shut-off devices
- Do not make any changes to the device! Do not replace the connecting cables yourself.
- Do not carry out repairs yourself, but appoint a specialist or contact after-sales service to avoid any risks.
- Only have faulty parts replaced with origi-nal spare parts.
Assembly
NOTE! Do not install in areas at risk of frost!
- CAUTION! Turn off the main water sup-ply before installation. Otherwise, there is a risk of injury and/or damage to proper-ty.
- If the mains connection cable of this device is damaged, it must be replaced by the manufacturer, its customer service depart-ment or an equally qualified person in order to avoid hazards.
- Only connect the device to a cold water line! If you have any questions or doubts, please consult a plumbing specialist.
- CAUTION! Turn off the water supply before installation.
- CAUTION! Do not twist the connecting hose and do not apply tension to it.
- Remove the protective cap from the fitting thread 18, then unscrew the fixing nut 12 and the two cable guide rings 13a and 13b from the fitting thread 18.
The fitting can be mounted so that the power cable is routed below or above the work surface (worktop, sink).
Below the work surface (Fig. D)
-
Step 1:
The hole in the work surface must be large enough to allow the power cable with mains plug 15 to pass through.
Insert the power cable with mains plug 15 and the fitting thread 18 into the hole of the work surface -
Step 2:
Guide the cable guide ring white 13a from below – with the closed surface facing downwards – onto the fitting thread 18 and place the power cable in the corresponding opening. -
Step 3:
Screw the fixing nut 12 onto the fitting thread 18. Make sure that the housing is firmly mounted on the work surface and tighten the fastening nut again if necessary. -
Step 4:
Fasten the enclosed flex. connecting hose 14 with the larger 1/2″ thread on the fitting thread 18, and on the other side (3/8″ thread) on thecold water valve. -
Step 5:
After successful installation, open the water supply.- Note : Do not plug the mains plug into the socket yet!
Above the work surface (Fig. E)
-
Step 1:
Guide the cable guide ring chrome 13b from below – with the closed surface facing downwards – onto the fitting thread 18 and place the power cable in the corresponding opening. -
Step 2:
Insert the fitting thread 18 into the hole of the work surface -
Step 3:
Screw the fixing nut 12 onto the fitting thread 18. Make sure that the housing is firmly mounted on the work surface and tighten the fastening nut again if necessary. -
Step 4:
Fasten the enclosed flex. connecting hose 14 with the larger 1/2″ thread on the fitting thread 18, and on the other side (3/8″ thread) on the cold water valve. -
Step 5:
After successful installation, open the water supply.- Note : Do not plug the mains plug into the socket yet!
Operation
Commissioning
- It is essential that all connections are carefully checked for leaks after commissioning.
- Check the operation of the fitting. To do this, turn the lever 10 forwards.
- Do not plug the mains plug into the socket until there is no leakage.
Set the water temperature
The water supply is switched off when the lever is at an 10 angle of approx. 45°C to the fitting body, 16 symbol “0”
- Cold water: Turn the lever 10 forwards (blue marking). The lower you turn the lever, the greater the water flow (the flow rate)
- Hot water: Turn the lever 10 backwards (red marking). The further you turn the lever back-wards, the greater the water flow (flow rate) will be. Attention: as the water flow (flow rate) increases, the water temperature in the hot water range decreases.
The display 17 shows the current water temperature.
Note : Due to the measuring point inside the fitting body 16, there may be slight temperature deviations between the escaping water and what is shown on the display 17.
Note:
Electricity is only used for hot water genera-tion!
Cleaning and maintenance
Standard note on fitting care and cleaning
To clean the aerator, 2 unscrew the aerator housing 1 anticlockwise and
remove the aerator 2 and aerator gasket 3 . Remove limescale residues from the
aerator 2 and screw the individual parts together again. If the water flow
becomes weaker or irregular, the filter 19 in the fitting thread should be 18
cleaned. To clean it, loosen the flex. connect-ing hose 14 from the fitting
thread 18 and remove the filter 19 from the fitting thread 18 with a finger or
a blunt object. Remove limescale residues from the filter 19 and place it back
into the fitting thread 18 with the open-ing facing downwards. Then fasten the
flex. connecting hose 14 on the fitting thread.
Replace cartridge (7) (Fig. F)
-
Step 1:
Unscrew the lever 10 from the lever cover 11. -
Step 2:
Pull off the lever cover 11 -
Step 3:
Unscrew the screw inside 9 (screwdriver not included) and pull out the lever wheel 8 -
Step 4:
Unscrew the lock nut anticlockwise 6 -
Step 5:
Unscrew the 6 screws 7 (screwdriver not in-cluded), remove the cartridge housing 5 and then the cartridge 4 . Replace the cartridge and reassemble in reverse order.
Temperature and water flow curve
Dependence on temperature and flow rate
The greater the flow rate of the hot water, the cooler the water. If the water only reaches lukewarm tempera-ture, reduce the water flow using the lever 10 (°C)
Troubleshooting
- Water flow becomes weaker: see chapter Cleaning and maintenance The filter 18 in the fitting thread 18 and the aerator 2 should be cleaned.
- The water does not heat up (no display): the mains plug is not correctly seated in the socket – correct the position of the mains plug
- The socket is faulty: try another socket: there is no mains voltage Check the fuse in the fuse box
- The water only reaches lukewarm temperature (despite the display): reduce the water flow/flow rate in the hot water range
- Fuse in fuse box has tripped: Too many devices in a circuit – reduce the number of connected devices.11111
Disposal
The packaging is made of environmentally friendly materials, which you can
dispose of at the local recycling points. Contact your local authority or
municipality for information on disposing of the product at the end of its
service life.
If your product has reached the end of its useful life, do not dispose of it with household waste, but dispose of it in the correct way to help protect the environment. You can find information on collection points and their opening hours from your responsible authority.
Information
Suitability of tap water for drinking
Check with your local authorities for informa-tion the drinkability of the water in your city/municipality. In general, the following recommendation applies to the drinkability of tap water:
- Allow water from pipes to run for a short time if it has stagnated in the pipes for more than four hours. Do not use stagnant water to prepare food and for drinking, especially when feeding infants. Failure to follow these recommendations may lead to discomfort. Fresh water can be recognised by the fact that it comes out of the tap noticeably cooler than stagnant water.
- Do not use stagnant water from chrome-plated pipes for food and/or per-sonal care if you are allergic to nickel. This water can be contain high levels of nickel and cause an allergic reaction.
- Do not use stagnant water from chrome-plated pipes for food and/or per-sonal care if you are allergic to nickel. This water can be contain high levels of nickel and cause an allergic reaction.
Warranty and service
The product has been carefully produced in accordance with strict quality guidelines and carefully tested before delivery. In the event of defects in this product, you have legal rights against the seller of the product. These statuto-ry rights are not limited by our warranty as set out below. This product is covered under warranty for 3 years from the date of purchase. The warranty period begins on the date of purchase. Please keep the original receipt safe. This document is required as proof of purchase. If a material or manufacturing defect occurs within 3 years of the date of purchase of this product, we will repair or replace the product for you, at our discretion, free of charge. This warranty is rendered void if the product has been damaged, used incorrectly or not main-tained correctly. The warranty applies to material or manufac-turing defects. This warranty does not cover product parts that are subject to normal wear and tear (e.g. batteries) and can therefore be regarded as wear parts, or damage to fragile parts, e.g. switches, batteries or those made of glass.
After-sales service
Conmetall Meister GmbH Oberkamper Str 39 Incoming goods gate 3 42349 Wuppertal
GERMANY
Tel. 0202 24750 430 / 431 / 432 (call costs according to the landline tariff of your service provider)
Tel. +800 34 99 67 53 (from abroad) E-mail: meister- service@conmetallmeister.de
IAN 402407_2204
Please keep the receipt and the article number (e.g. IAN 402407_2204) as
proof of purchase for any inquiries.
Product information
Where applicable to the product, the following information is based on the
requirements of Regulations (EU) 812/2013 and (EU) 814/2013
Product information | Symbols | Unit | LH-SH-1 |
---|---|---|---|
Specified load profile | 3XS | ||
Hot water preparation energy efficiency class | A | ||
Hot water preparation energy efficiency | ŋWH | % | 38,9 |
Annual electricity consumption | AEC | kWh | 77,9 |
Sound power level inside | LWA | dB | 15 |
Indication of the ability to operate outside peak hours | No |
Special precautions to be taken during assembly, installation or maintenance
(if applicable):| | See documentation accompanying the product|
Intelligent control| | | No
Daily electricity consumption (average climate conditions)| Qelec| kWh| 0,358
Products marked with this symbol comply with all applicable Community regulations of the European Economic Area.
Ident.-No.: WU6823550-8052022