Panasonic FV-25GS4 Industrial Exhaust Fans Instruction Manual
- June 15, 2024
- Panasonic
Table of Contents
Operating Instructions Ventilating Fan
FV-25GS4 FV-30GS4 FV-35GS4 FV-40GS4
Thank you very much for having purchased Panasonic Ventilating Fan.
Please read these instructions carefully before attempting to install, operate
or service the Panasonic Ventilating Fan. Failure to comply with instructions
could result in personal injury and/or property damage. Please retain this
booklet for future reference.
INSTALLATION CAUTIONS
- Disconnect power supply before maintenance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- This product is not intended for use by persons (including children) with reduced physical,sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person responsible for the safety. Children should be supervised to ensure thatthey do not play with the product.
-
This fan is designed for industrial use, it can be used in factories, warehouses, shops, commercial kitchens and other places where large air change is necessary.
-
Do not install this fan in a place where there is explosive gas or corrosive gas.
-
Do not install this fan in a place there is a great amount of humidity (such as the bathroom, kitchen, etc.).
-
After installation, remove the drain caps on the bottom side.
-
Use the equipment at the rated voltage and frequency indicated in the name plate.
-
Do not install the ventilating fan outside of the window or the wall.
-
This fan should be installed so that the blades are more than 2.3m above the floor.
Malaysia market:This fan should be installed so that the blades are more than 2.5m above the floor. -
For this fan,precautions must be taken to avoid the back-flow of gases into the room from the open-flue of gas or other fuel-burning appliances.
-
The product must not be mounted on a wall not strong enough.If it cannot be ensured that the wall will bear the weight of the mounted product, that wall must be reinforced.
-
The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided.
-
This fan must be installed by a qualified technician. Otherwise, it is possible to drop down.
-
Installation procedures must be carried out properly according to the instructions.
-
Do not disassemble the unit for reconstruction.
-
A statement to the effect that when the product is to no longer be used, it must not be left in place but removed, to prevent it from possibly falling.
IDENTIFICATION OF PARTS; MEASUREMENTS
[FV-25GS4,FV-30GS4,FV-35GS4]1| Frame
---|---
2| Blade setscrew
3| Motor
4| Motor support
5| Blade
6| Power cord
7| Fitting hole 8
Model| A| B| C| D| E| F| G| H
---|---|---|---|---|---|---|---|---
FV-25GS4| 327| 298| 165| —| 171| 10 dia.| —| 250 dia.
FV-30GS4| 378| 349| 210| –| 200| 10 dia.| –| 300 dia.
FV-35GS4| 467| 434| 250| —| 236| 12 dia.| –| 350 dia.
Dimensions: mm
1 | Frame |
---|---|
2 | Blade setscrew |
3 | Motor |
4 | Motor support |
5 | Blade |
6 | Power cord |
7 | Fitting hole 8 |
8 | Fitting hole 4 |
Model | |
--- | --- |
A | B |
FV-40GS4 | 518 |
HOW TO INSTALL
During installation and carrying work, take special care not to deform the
blade. If the blade is deformed, troubles such as unbalance or vibration may
occur.
Installation on concrete wall
Installation on wooden frame
Model | W |
---|---|
FV-25GS4 | 275 sq. |
FV-30GS4 | 325 sq. |
FV-35GS4 | 395 sq. |
FV-40GS4 | 445 sq. |
Model | W |
--- | --- |
FV-25GS4 | 275 sq. |
FV-30GS4 | 325 sq. |
FV-35GS4 | 395 sq. |
FV-40GS4 | 445 sq. |
- The fan can be used facing to the side or up and be sure to remove the drain cap which is installed at the bottom.
- Use the switch that complies with IEC 60335 and have qualified personal connect install the switch in the manner describet in this manual.
Wiring Diagram (Exhaust)
- Must be installed in a fixed wiring with an all pole disconnections switch which the contact separation is more than 3 mm.
1 | White |
---|---|
2 | Yellow |
3 | Red |
4 | Blue |
5 | Black |
6 | Brown |
7 | Green/Yellow |
HOW TO REVERSE AIR FLOW
- Loosen the blade setscrew to remove the blade.
- Remove the wiring cover setscrew and exchange the yellow and red wires according to the wiring diagram.
- Mount the blade in reverse position, and completely secure it in the air intake blade position.
- Loosen the blade setscrew to remove the blade.
- Remove the two (2) wiring box setscrews and exchange the yellow and red wires according to the wiring diagram. After exchanging, re-install the wiring box in its original position.
- Mount the blade in reverse position, and completely secure it in the air intake blade position.
Wiring Diagram (Air intake)
- Must be installed in a fixed wiring with an all pole disconnections switch which the contact separation is more than Smm.
1 | White |
---|---|
2 | Yellow |
3 | Red |
4 | Blue |
5 | Black |
6 | Brown |
7 | Green/Yellow |
MAINTENANCE CAUTIONS
- Before beginning any maintenance, be sure to disconnect the power cord from the power supply.
- Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
SPECIFICATIONS
Model No.| Voltage
[V]| Frequency
[Hz]| Powerconsumption
[W]I| Speed
[min-1]| Air delivery
[m3/min] ([CMH])| Power factor
[%]| Weight
[kg]
---|---|---|---|---|---|---|---
FV-25GS4| 110 – 127V ∼| 50| 38-46| 1350-1385| 18.3-18.5(1100-1110)| 86/81| 4.
60| 45-51| 1520-1600| 21.2-22.5(1270-1350)| 95/93
220 – 240V∼| 50| 39-44| 1360-1380| 18.3-18.7(1100-1120)| 89/87
240V ∼| 50| 44| 1380| 18.7(1120)| 87
220 – 230V∼| 60| 47-50| 1560-1580| 20.8-22.3(1250-1340)| 97/99
FV-30GS4| 110 – 127V ∼| 50| 52-61| 1360-1395| 29.2-29.5(1750-1770)| 95/91| 6.
60| 67-78| 1560-1615| 34.3-35.8(2060-2150)| 99/99
220 – 240V∼| 50| 59-65| 1360-1380| 30-30.3(1800-1820)| 99/99
240V∼| 50| 65| 1380| 30.3(1820)| 99
220 – 230V∼| 60| 80-84| 1560-1580| 34.7-35.5(2080-2130)| 99/99
FV-35GS4| 110 – 127V ∼| 50| 80-92| 1360-1400| 40.7(2440)| 82/76| 11.
60| 111-120| 1520-1630| 45.8-46.5(2750-2790)| 92/95
220 – 240v,| 50| 88-95| 1420-1430| 42.7-43.2(2560-2590)| 98/94
240V ∼| 50| 95| 1430| 43.2(2590)| 94
220 – 230V∼| 60| 127-130| 1660-1670| 49-50.2(2940-3010)| 99/99
FV-40GS4| 110 – 127V ∼| 50| 150-180| 1440-1450| 63.3-63.5(3800-3810)| 62/55|
19
60| 199-218| 1690-1720| 74-74.3(4440-4460)| 91/86
220 – 240V∼| 50| 161-181| 1450-1460| 60.2-61.2(3610-3670)| 67/63
240V ∼| 50| 181| 1460| 61.2(3670)| 63
220 – 230V∼| 60| 210-214| 1710-1720| 70.7-71.3(4240-4280)| 95/93
AMCA SPECIFICATIONS
Model No.| Voltage
[V]| Frequency
[Hz]|
Air delivery and Noise at static pressure
| Powerconsumption [W] | Power consumption [W]
---|---|---|---|---|---
In. wg| 0| 0.05| 0.075| 0.1| 0.125| 0.25| 0.375| 0.5| 0.75
FV-25GS4| 220| 60| CFM| 684| 647| 621| 591| 548| 93| –| –| –| 51| 47
Sones| 4.1| 3.2| 3.2| 3.4| 3.4| 8.2| –| –| –
240| 50| CFM| 613| 548| 522| 488| 447| 83| –| –| –| 47| 44
Sones| 2.8| 2.7| 2.8| 2.9| 3.2| 7.6| –| –| –
FV-30GS4| 220| 60| CFM| 1138| 1086| 1058| 1027| 995| 456| 150| –| –| 85| 80
Sones| 8.3| 7.8| 7.6| 7.9| 6.7| 6.2| 9.3| –| –
240| 50| CFM| 996| 890| 840| 780| 720| 359| 141| –| –| 70| 65
Sones| 4.3| 4.3| 4.2| 4.2| 4.4| 6.2| 9.1| –| –
FV-35GS4| 220| 60| CFM| 1609| 1558| 1534| 1505| 1474| 1279| 332| –| –| 135|
127
Sones| 6.4| 6.0| 6.0| 6.2| 6.2| 6.5| 8.6| –| –
240| 50| CFM| 1417| 1367| 1340| 1308| 1273| 1034| 336| –| –| 102| 9 5
Sones| 6.0| 5.8| 5.5| 5.4| 5.7| 5.8| 11.1| –| –
FV-40GS4| 220| 60| CFM| 2320| 2267| 2240| 2214| 2189| 2043| 1850| 1488| 476|
223| 210
Sones| 7.0| 7.0| 7.1| 7.2| 6.7| 6.8| 7.4| 10.2| 17.2
240| 50| CFM| 2009| 1949| 1919| 1888| 1859| 1681| 1368| 630| 185| 193| 181
Sones| 5.6| 5.6| 5.7| 5.7| 5.8| 6.2| 8.5| 14.0| 15.8
The ratings shown are based on tests and procedures performed in accordance
with AMCA Publication 211 and AMCA Publication 311.
The Watts rating is only for AMCA test method and itis at the static pressure
of 0 inch of H:O.
The Watts rating is only for IEC test method
Panasonic Corporation
Web site: http://www.panasonic.com
© Panasonic Corporation 2022
P0522-0 25G454020
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>