TRACE™ Horizontal Installation Instructions
7101009 TRACE Horizontal
Profiles:
TRACE™ is an indoor/outdoor low voltage lighting system used primarily for direct or indirect lighting designs.
Please verify the contents of the packages!
Please read instructions entirely before starting installation
Be sure power is turned off before installing the system
Call Tivoli, LLC tech support with questions
Caution: TRACE™ TW is designed to work with listed Class 2 24V
DC transformers only. Use of any other power source will cause damage, shorten
the life of the fixture and will void the warranty.
Consult any and all applicable local and national codes for installation.
Do not conceal or extend exposed conductors through a building wall as
per local electrical code.
Warning: With any luminaire for any application, basic safety precautions
should always be followed to reduce the risk of fire, electric shock and
personal injuries. This lighting system should be installed by a certified
professional.
WARNINGS
TRACE™ TUNABLE WHITE MAY BE EASILY DAMAGED! The reliability of the
product can only be ensured if these warnings and cautions are complied with
faithfully. Keep these instructions for future maintenance work.
WARNING! Risk of product damage. Longer runs of Trace™ lighting strands
must be installed by at least two people.
IMPORTANT! The Trace™ luminaire must not be allowed to bend or hang down.
That way, the bending limit will not be inadvertently exceeded, resulting in
product damage.
Warning! Risk of product damage.
Trace™ Tunable White Horizontal must not be bent at less than 2.0” diameter or
damage will result. Do not allow Trace™ to twist or bend in the wrong
direction.
WARNING! Risk of Damage. Insert Trace™ Tunable White Horizontal into
channel evenly and gradually to keep twisting and bending to a minimum.
Overview: Read Before Installing Luminaire
Installation Notes:
Step 1: Measure run area where Trace™ TW is to be installed. Locate power
feed end at highest point of the run to minimize exposure to water run off.
Step 2: A Mounting Channel is recommended for outdoor applications. Lay
channel along desired area and attach with screws (by others) every 18 to 24
inches. If the design requires creating bends and arcs, it is recommended that
the Horizontal Notched Channel be used.
Note: Minimum bending diameter for the notched channel is 11”. Trace™
Horizontal must not be bent less than 2” diameter or damage will result.
Step 3: Trace™ must be installed with two people. One to press the
luminaire into the channel and the other to hold the spool and unroll it while
keeping the Trace™ flex body straight.
Warning: Risk of Product damage.
Do not stretch, pull, or yank. Doing so can damage the Trace™ internal
connections and void the warranty.
Note: We recommend using a dry spray lubricant, such as 3M Spray
Lubricant or WD-40 Specialist for all Trace™ installations to insure the
luminaire fits into the channel without damage. Additionally, Silicone Sealant
(FLXD-SIL-GE-10) must be applied to the inside bottom surface.
Step 4: Insert Trace™ into mounted channel starting from power connector
end. The End Cap and Power Feed Connector do not fit within the channel, so
cut the Mounting Channel so that connectors and End Caps will overhang outside
the ends of the Channel. Trace™ should be pressed into the channel carefully
and gradually, without excessive bending or damage will result.
Step 5: Secure power connection to building with use of C-clamp (by
others) or mount connection inside J-Box.
Connect to 24V DC power supply according to supplied wiring diagrams.
Trace RGBW Mounting Options
Trace™ Horizontal with Mounting Clips
Warning: Risk of Product Damage.
Only bend the Trace™ RGBW Horizontal so the lens bends side to side.
See diagram below.
Note: Minimum bending diameter for Trace™ Horizontal is 2” in the
horizontal direction only.
Step 1: Determine where the Mounting Clips will need to be installed to
achieve the desired shape.
Step 2: Position the Mounting Clips and attach with screws (Included).
Step 3: Lay a bead of Silicone Adhesive (LFXD-SIL-GE-10) to the inside
bottom surfaces of the Mounting Clips, as shown.
Step 4: Spray Dry Lubricant on a rag and wipe the inside upper surfaces
of the mounting clips, as shown, to allow the Trace™ fixture to slide more
easily into the mounting clip. 3M Spray Lubricant or WD-40 Specialist is
recommended.
Warning! Risk of Product Damage.
Regular WD40 490002 will stress craze, crack or swell the Trace™ Silicone
covering. Do not use!
Step 5: Trace™ must be installed with two people. One to press the
luminaire into the channel and the other to hold the spool and unroll it while
keeping the Trace™ flex body straight.
Step 6: Press Trace™ into the Mounting Clip carefully and gradually,
without excessive bending or damage will result.
WARNING! Risk of Product Damage.
Do not hammer or pound the luminaire into the channel. Once inserted, do not
pull or yank on the fixture. Trace™ will be damaged unless it is handled
carefully.
Step 7: Connect to power.
Bending Limitations
Warning! Risk of Product Damage.
Trace™ RGBW Horizontal can only be bent in the direction that does not twist
the Tape Light.
Install Trace™ TW Horizontal in Notched Mounting Channel
Warning: Risk of Product Damage.
Only bend the Trace™ Horizontal so the lens bends side to side so as not to
twist the Tape Light. See diagram.
Note: Minimum bending diameter for the notched channel is 11”.
However, the minimum bending diameter for Trace™ Horizontal is 2” in the
horizontal direction only.
Step 1: Determine Channel mounting Location.
Step 2: Drill a hole 3” from each end of the Channel and 18”-24” along
length of Channel.
Step 3: Position the Notched Channel and attach with screws (by others).
Step 4: Lay a bead of Silicone Adhesive (LFXD-SIL-GE-10) to the inside
bottom surfaces of the Notched Mounting Channel, as shown.
Step 5: Spray dry lubricant on a rag and wipe along the inside upper
surfaces of the extrusion. We recommend using a dry spray lubricant, such as
3M Spray Lubricant or WD-40 Specialist for all Trace™ installations to insure
the luminaire fits into the channel without damage.
Step 6: Start by orienting the Trace™ with the Lens facing away from the
Channel, as shown.
Step 7: Trace™ must be installed with two people. One to press the
luminaire into the channel and the other to hold the spool and unroll it while
keeping the Trace™ flex body straight.
Step 8: Insert the Trace™ body into the Channel one flex section at a
time. Start at one end and and press it down carefully and gradually, working
along the Channel, inserting the Trace™ body into each section until the
entire Trace™ fixture is securely mounted in the channel.
WARNING! Risk of Product Damage.
Do not hammer or pound the luminaire into the channel. Once inserted, do not
pull or yank on the fixture. Trace™ will be damaged unless it is handled
carefully.
Step 9: Connect to power.
Bending Limitations
Warning! Risk of Product Damage.
Trace™ TW Horizontal can only be bent in the direction that does not twist the
Tape Light.
Straight Channel for Trace™RGBW Horizontal Installation
Step 1: Prepare Straight Mounting Channel for installation cutting it to
the correct length, keeping in mind that the End Caps will not fit inside the
Channel, and by drilling screw holes 3” from each end and additional holes
approximately every 18” along the channel.
Step 2: Place Straight Channel on the mounting surface and mark the hole
locations.
Step 3: Remove the Channel and drill pilot holes at all hole locations.
Step 4: Place the Channel into position and secure with screws (not
included).
Note: Screws should be appropriate for the mounting
location. (ie: wood screws for wood, etc.)
Step 5: Lay a bead of Silicone Adhesive (LFXD-SIL-GE-10) to the inside
bottom surfaces of the Straight Channel, as shown.
Step 6: Spray dry lubricant on a rag and wipe along the inside upper
surfaces of the extrusion. We recommend using a dry spray lubricant, such as
3M Spray Lubricant or WD-40 Specialist for all Trace™ installations to insure
the luminaire fits into the channel without damage.
Step 7: Trace™ must be installed with two people. One to
press the luminaire into the channel and the other to hold the spool and
unroll it while keeping the Trace™ flex body straight.
Step 8: Start by orienting the Trace™ with the Lens facing away from the
Channel, as shown.
Step 9: IMPORTANT! Insert the Trace™ body into the Channel. Start at one
end and and press it down carefully and gradually, working along the Channel,
inserting the Trace™ body along the channel until the entire Trace™ fixture is
securely mounted in the channel.
WARNING! Risk of Product Damage.
Do not hammer or pound the luminaire into the channel. Once inserted, do not
pull or yank on the fixture. Trace™ will be damaged if it is not handled
carefully.
Step 9: Connect to power.
Bending Limitations
Warning! Risk of Product Damage.
Trace™ RGBW Horizontal can only be bent in the direction that does not twist
the Tape Light.
Note: Trace™ Mounting Channel can be mounted on horizontal or vertical surfaces.
Product Specification Guide
LUMINAIRE | POWER CONSUMPTION | MAX RUN LENGTH |
---|---|---|
Trace TW, Low Output | 1.5W | 58’ |
Trace TW, Standard | 3W | 29’ |
Trace TW, High Output | 4.5W | 19’ |
Trace™ RGBW Basic Wiring Diagram
Elecrical Connections for Trace™ Tunable White
Step 1: Turn power off before beginning electrical installation.
Note: Contacting hot wires against the Trace™ leads may damage the
product and void the warranty.
Step 2: Connect Trace™ lead wires to DMX-Sub-Controller, or if using our
ADUL-DIN series transformers, connect to pre-wired connectors which are found
inside the power supply box. Refer to diagram below, ADUL-DIN, or ADNM-DIN
installation instructions. Make sure each lead wire is connected to the
correct terminal, as follows:
LEAD WIRE
COLOR| SUB-CONTROLLER TERMINAL OR
ADUL-DIN CONNECTOR WIRE COLOR
---|---
Black| Black (+)
White| Blue
Red| Red
Green| Green
White| White
Step 3: Connect to a listed Class 2, 24V DC transformer only. See list of
approved transformers.
Step 4: Optionally, Trace™ TW may be dimmed using an MLV or ELV dimmer
that is suitable for the power supply. Please contact our technical support
staff for more information.
- DMX512 RDM decoder, RDM function can provide the interface between DMX master and decoder.
- OLED Display for example, DMX decoder’s address may be set from DMX master console.
- Multiple kinds of DMX in/out ports: RJ 45, XLR , normal screws.
- Total 5 PWM output channels, common anode. DMX channel quantity from 1CH~5CH programmable
- PWM output resolution ratio 8bit , 16bit settable.
- Output dimming curve gamma value from 0.1 ~ 9.9 settable.
- Programmable Decoding mode.
Safety and Warnings:
- Do not install with power applied to device.
- Do not expose to moisture.
Note: The Installation Instructions for your power supply includes DMX programming instructions.
Power Supply with Sub-Controller Sample Wiring Diagram
There are many possible options for controlling Trace™ RGBW. See the specification Sheet for more information. The following wiring diagram is for reference only. Please refer to the Installation Instruction for the Power Supply you choose for detailed wiring instructions.
7101009
Copyright © 2021 Tivoli 09.10.2021
www.tivolilighting.com tel:
714-957-6101 fax:
714-427-3458
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>