1. Safety instructions

NOTICE! The system should not be used for biologically contaminated water and water of unknown origin.
The device should be installed only by trained hydraulic service technicians. Use only original spare parts, filter elements and accessories by H2OO®.

Complying with the instruction guarantees the following:
– failure-free operation,
– resolving any claims resulting from the malfunction.

  1. Read the assembly instruction before installing the system.
  2. Check if the packaging contains all elements required for the installation (see point 5. – packaging content).
  3. After the system is installed, and after replacing initial filtration cartridges, in-line cartridges, RO membrane and when the system is idle for a long period of time (e.g. during leave) remember to rinse it and then leave for 5 – 6 hours in order to activate the filtering environment.
  4. Before removing the tubing first take out the safety clip for the quick connector, and then symmetrically press the collets.
  5. While removing and installing the tubing pay particular attention not to bend them (properly mounted tubing embeds 1,5 cm in the quick connector).
  6. While removing and installing the tubing do not change the position of the fittings screwed into the casing of the RO membrane.
  7. After installing the tubing in the quick connector secure the connection with a clip.
  8. To seal the plastic threads use only a teflon tape.
    Do not use a tow.
  9. Do not use aggressive cleaning agents to clean the housing.
    Before inserting a new cartridge make sure the housing is properly rinsed.
  10. When installing a new in-line cartridge in the system remember about the proper direction of water flow (the proper direction is marked with an arrow on the label of every in-line cartridge).
  11. Before and after replacing the cartridge or RO membrane make sure you wash your hands.
  12. Take out the RO membrane just before installing it in the housing.
  13. In case of any leaks, immediately disconnect the system from water supply. In case of systems equipped with a pump, disconnect the system from the electric power supply.
  14. Disinfect the system’s tank at least once a year. Do not rinse the elements inside the tank with running water since it might be contaminated.
  15. Water after osmotic filtration must comply with proper conditions (see point 4.). Complaints will not be recognized.
  16. The manufacturer is not responsible for any damages resulting from using the systems for purposes other than water filtration.

Use only the original H2O® cartridges and filtering membranes. When using elements of a different company, the manufacturer is not responsible for the incorrect operation of the system and for any damages resulting from it.

2. Filtration technology with a reverse osmosis method

The membrane stops 96% – 99% of organic and non-organic pollutants dissolved in water, as well as bacteria and viruses. The semipermeable RO membrane consists of many layers winded around a perforated mandrel located inside the membrane. The contaminated water is pressed under pressure to the Surface of the membrane, where water particles pass through the microscopic pores in the membrane. Pollutants are separated and removed to the drain.

Cross-section of the TFC membrane

  1. PERFORATED MANDREL
  2. SEAL
  3. WATER INLET
  4. PERMEABLE LAYERS
  5. REJECT
  6. PERMEATE WATER
3. System technical parameters – general information

Dimensions of the PRO3200Ptank (height x diameter) ………………. 345mm x 235 mm
Capacity of the tank ………………………………………………………………………….. 12 litres*
Work temperature …………………………………………….. from 2°C to 45°C (35°F – 113°F)
Work pressure ………………………………………………….. 2,8 bar – 6 bar (40.6 psi – 90 psi)
Capacity** ………………………………. 280 l / day (TFC-75F / TFC-75F-AQM membrane)
Water connection …………………………………………………………………………………… 3/8″

NOTICE! The system will work properly if the pressure limiting valve is installed. For RX and RP systems it is the PLV-0104-80 model (5.3 bar – 80 psi – not included in the set). The device protects the system from pressure jumps, water hammer and too high pressure in the installation. Without the pressure regulator you warranty for elements working under pressure will be void.

  • nominal capacity (RX-RO5-H2OO, RX-RO5-NN – RX52135316NN, RX-RO6-H2OO, RX-RO6-NN – RX62135316NN, RX-RO7-H2OO)
    ** nominal capacity
3.1. System dimensions

RX-RO5-H2OO
RX-RO5-NN RX52135316NN
Dim. (height x width x length)
400 x 140 x 390 (mm)

RX-RO6-H2OO
RX-RO6-NN (RX62135316NN)
Dim. (height x width x length)
450 x 140 x 390 (mm)

RX-RO7-H2OO
Dim. (height x width x length)
450 x 140 x 390 (mm)

RX-AFRO4-ECO2
Wymiary (wys. x szer. x dł.)
380 x 140 x 390 (mm)

RX-AFRO5-ECO
Wymiary (wys. x szer. x dł.)
400 x 140 x 390 (mm)

4. Parameters for the water supplied to the RO (Reverse

Osmosis)*systems

Water pH …………………………………………………….. 2 pH – 11 pH
Мax. general hardness ………………………………….. 400 ppm³ (mg / l)
Max. alkalinity ………………………………………………. 8 mval/l
Iron and manganese contents ……………………….. Fe 0.2 ppm³ (mg / l), Mn 0,05 ppm (mg/l)
Max. SDI¹ index …………………………………………….. SDI 5
Max. water salinity TDS² ………………………………… 2000 ppm³ (mg / l)

¹ SDI – (Sald Density Index) a coefficient that influences the design of the reverse osmosis system. It expresses the ability of water to contaminate the membranes. Its value should be < 5.
² TDS – (Total Disolved Solids) degree of water salinity.
³ ppm – one part per million.

  • the distributor is not responsible for damages resulting from using the system with water parameters that do not comply with the foregoing requirements.
5. Package content

Reverse Osmosis System

Tank (12 litres)¹

Chrome-plated faucet²

Chrome-plated faucet³

Cartridge from polypropylene fiber 20 mic.

Cartridge from activated carbon (block)

Cartridge from polypropylene fiber 5 mic.

RO membrane 75 GPD

Wrench

Connection with a gasket (3/8” MIP x 3/8” FIP x 1/4” FIP)

Teflon tape TAS0004

Ball valve

Tubing

Clamp

Ball valve for the cartridge

Instruction

2 x Valve4

  • nominal capacity
    ¹ RX-RO5-H2OO, RX52135316NN, RX-RO6-H2OO, RX-RO6-NN (RX62135316NN), RX- RO7-H2OO
    ² RX-RO5-H2OO, RX52135316NN, RX-RO6-NN (RX62135316NN)
    ¹ RX-RO6-H2OO, RX-RO7-H2OO
    ² RX-AFRO5-ECO, RX-AFRO4-ECO2
6. Method of connecting the tubing to quick connectors type JG (John

Guest) and QC (Quick connector)

Disconnecting the tubing:

  1. Remove the safety clip from the quick connector (if any) (fig. 1).
  2. Symmetrically press the collets of the quick connector (fig. 2).
  3. Remove the tubing (fig. 3).

Connecting the tubing:

  1. Push the tubing into the quick connector (properly mounted tubing embeds 1,5 cm into the quick connector) (fig. 4).
  2. Place the safety clip (if any) (fig. 5).

fig. 1                             fig. 2

fig. 3                               fig. 4

fig. 5

6.1. Methods of disassembling and installing the bushing in the

cartridge (new cartridge with screw-in elbow connector)

Disassembling the bushing from the cartridge:

  1. Remove the safety clip from the quick connector (fig. 1).
  2. Symmetrically press the collets of the quick connector and pull out the tubing (fig. 2).
  3. Unscrew the coupling from the old cartridge (at the water inlet and outlet). (fig. 3).
  4. Remove the old pipe tape from the coupling thread (fig. 4).
  5. Roll several layers of pipe tape on the coupling thread. The thread should be placed in the direction reverse to the direction in which the coupling is screwed in (fig. 5).

Mounting the coupling in the cartridge:

  1. Screw the elbow connector into the new cartridge. Watch out not to reverse the elbow connector. Reversing the screwed element may unseal the connection and lead to water leaks (fig. 6).

fig. 1                             fig. 2

fig. 3                            fig. 4

fig. 5                               fig. 6

7. Installing the FXFCH5, faucet*

FXFCH

  1. Drill a 12 mm hole in the kitchen sink worktop (in case of enamelled sinks the manufacturer recommends drilling the holes in the construction supporting the sink) or in the kitchen worktop.
  2. Put a metal washer 2, and then a rubber seal 3 on the thread nozzle of the faucet.
  3. Place the faucet in the previously drilled hole.
  4. Place washers on the nozzle at the bottom side of the worktop 4, 5 (made of rubber), 6 (made of metal) and screw in with a nut 7.
  5. Mount the tubing supplying the water and connecting the faucet with the system:
    – place the tubing 11 on a metal nut 10 and a plastic clamp 9
    – push an insert 8 into the tubing.
    – slide the tubing (until it stops) inside the faucet nozzle and screw it in (manually!) with a nut that was placed on the tubing earlier.

NOTICE: To seal the thread connections always use the pipe tape during an assembly. Does not apply to threads for plastic nuts and for the faucet nuts.

  • RX-RO5-H2OO, RX52135316NN, RX-RO6-NN (RX62135316NN)
8. Installing the FXFCH4 faucet*

FXFCH4

  1. To mount the faucet (fig.) drill two 12 mm holes in the kitchen worktop or in the kitchen sink (in case of enamelled sinks the manufacturer recommends drilling the holes in the construction supporting the sink).
    Space between the holes – 18 mm.
  2. Put a washer 2, and then a rubber seal 3 on the thread nozzle of the faucet.
  3. Place the faucet in the previously drilled holes.
  4. Place washers on the nozzle at the bottom side of the worktop (4,5) and screw in with a nut (6).
  5. Mount the tubing supplying water to the faucet. To do this, place metal nuts (9) and plastic clamps (8) on the tubing and push inserts (7) into the tubing.
  6. Slide the tubing (until it stops) inside the faucet nozzle and screw it in (manually!) with a nut that was placed on the tubing earlier.

NOTICE: To seal the thread connections always use the pipe tape during an assembly. Does not apply to threads for plastic nuts and for the faucet nuts

*RX-RO6-H2OO, RX-RO7-H2OO

9. Filtering cartridges

|

RX-RO5-H2OO
RX-RO5-NN (RX52135316NN)

|

RX-RO6-H2OO
RX-RO6-NN (RX62135316NN)

| RX-RO7-H2OO| RX-AFRO4-ECO2| RX-AFRO5-ECO
---|---|---|---|---|---
Housing 1|

WPP5H

| WPP5H| WPP5H| WPP5H|

WPP5H

Housing 2|

WWBH

| WWBH| WWBH| WWBH|

WWBH

Housing 3|

WPP20H

| WPP20H| WPP20H| WPP20H|

WPP20H

Housing 4|

TFC-75F-AQM

| TFC-75F-AQM| TFC-75F-AQM| TFC-75F-AQM|

TFC-75F-AQM

In-line filter cartridge 1|

WWH1

| WWH1| WWH1| |

In-line filter cartridge 2|

| WMH1| WMH1| |

In-line filter cartridge 3|

| | WFIR| |

Table 1. Cartridge configuration for individual systems

Type of cartridge Description **Longevity*** Size
WPP20H Sediment filter for cold water. Used to filter potable and

utility water – stops sand, rust particles, suspended solids and contaminants contained in water with grain size of 20 microns and more. A polypropylene spun cartridge improves organoleptic parameters of water.| 3 – 6 months| 10” x 2 1/2”
(25 cm x 6,5 cm)
| WPP5H Sediment filter for cold water. Used to filter potable and utility water – stops sand, rust particles, suspended solids and contaminants contained in water with grain size of 5 microns and more. A polypropylene spun cartridge improves organoleptic parameters of water. | 3 – 6 months| 10” x 2 1/2”
(25 cm x 6,5 cm)
| WWBH Purifying cartridge. Contains cemented carbon with high absorption of chlorine and organic substances contained in water. The cemented carbon has twice the active Surface and higher water filtering efficiency.| 3 – 6 months| 9 7/8” x 2 1/2”
(25 cm x 6,5 cm)
| WWH1 Cartridge with coconut shell carbon. Improves the taste and smell of water.| 6 – 12 months| 10” x 2”
(25 cm x 5,08 cm)
| WMH1 Mineralizing cartridge. Enriches water with minerals essential for human organism, such as calcium, magnesium, sodium, potassium.| 6 – 12 months| 10” x 2”
(25 cm x 5,08 cm)
| WWDI De-ionising line cartridge| 3 – 6 months| 10” x 2”
(25 cm x 5,08 cm)
| WFIR 2” ionizing cartridge, regulates pH of the organism, removes toxins, ionized water is an excellent detoxicating agent.| 6 – 12 months| 10,8” x 2”
(27,5 cm x 5 cm)
| RO membrane removes 96% – 99% of all pollutants from water (including some bacteria and viruses).| up to 36 months| 11,9” x 1,8”
(30 cm x 4,5 cm)

*depending on the quality of water and its contamination.

When using the system for the first time and after every replacement of cartridges remember to rinse the system. Rinse time should be longer than 5 minutes. Next leave the system for 5-6 hours to activate the filtering environment. After that you may start drinking the water.
NOTICE! Cartridges are not covered with warranty in the following instances:
– the protective film is taken off,
– when the cartridges are being used.

**Rinsing the system***

NOTICE! When using the system for the first time and after every replacement of filtering cartridges or the membrane remember to rinse the system.
Wait 60 minutes until the tank fills with water, then open the faucet valve and pour the entire water out of the tank.
NOTICE! Do not drink this batch of water.
After rinsing, leave the system for 5 – 6 hours to activate the filtering environment, then pour the entire water out of the tank again.
NOTICE! Do not drink this batch of water.
When completing the foregoing you may start drinking the filtered water.

*RX-RO5-H2OO, RX52135316NN, RX-RO6-H2OO, RX-RO6-NN (RX62135316NN), RX-RO7-H2OO

Rinsing the system**

Wash the system with approximately 15 litres of water. Washing time should be no shorter than 60 minutes.
WARNING! This water is not suitable for consumption.
Once this is done, the system can be used.

**RX-AFRO5-ECO, RX-AFRO4-ECO2

10. System flow diagram RX-RO5-H2OO, RX-RO5-NN (RX52135316NN)

A

| Water supply to the first housing
---|---

B

| Water supply to the second housing

C

| Water supply to the third housing

D

| Housing with the RO membrane

E

| Four-way valve

F

| In-line cartridge with activated carbon

G

| Flow restrictor

H

| Tank valve

I

| Tank

J

| Faucet

1

| Clean water outlet

2

| Pollutants outlet

3

| Water supply to the four-way valve from the elbow connector “OUT” in the third housing

4

| Clean water supply to the four-way valve through the membrane

5

| Water outlet from the valve to the membrane

6

| Clean water outlet from the valve to the in-line cartridge with activated carbon

Water supply to the filter from the FT03 or FT07, FT06 connection (option)

a) Outlet for contaminations
– connection with the outlet clamp SC500B14

10.1. System flow diagram RX-RO6-NN (RX62135316NN)

A

| Water supply to the first housing
---|---

B

| Water supply to the second housing

C

| Water supply to the third housing

D

| Housing with the RO membrane

E

| Four-way valve

F

| In-line cartridge with activated carbon

G

| Mineralizing cartridge

H

| Flow restrictor

I

| Tank valve

J

| Tank

K

| Faucet

1

| Clean water outlet

2

| Pollutants outlet

3

| Water supply to the four-way valve from the elbow connector “OUT” in the third housing

4

| Clean water supply to the four-way valve through the membrane

5

| Water outlet from the valve to the membrane

6

| Clean water outlet from the valve to the in-line cartridge with activated carbon

Water supply to the filter from the FT03 or FT07, FT06 connection (option)

a) Outlet for contaminations
– connection with the outlet clamp SC500B14

10.2. System flow diagram RX-RO6-H2OO

A

| Water supply to the first housing
---|---

B

| Water supply to the second housing

C

| Water supply to the third housing

D

| Housing with the RO membrane

E

| Four-way valve

F

| In-line cartridge with activated carbon

G

| Mineralizing cartridge

H

| Flow restrictor

I

| Tank valve

J

| Tank

K

| Faucet

1

| Clean water outlet

2

| Pollutants outlet

3

| Water supply to the four-way valve from the elbow connector “OUT” in the third housing

4

| Clean water supply to the four-way valve through the membrane

5

| Water outlet from the valve to the membrane

6

| Clean water outlet from the valve to the in-line cartridge with activated carbon

Water supply to the filter from the FT03 or FT07, FT06 connection (option)

a) Outlet for contaminations
– connection with the outlet clamp SC500B14

10.3. System flow diagram RX-RO7-H2OO

A

| Water supply to the first housing
---|---

B

| Water supply to the second housing

C

| Water supply to the third housing

D

| Housing with the RO membrane

E

| Four-way valve

F

| In-line cartridge with activated carbon

G

| Mineralizing cartridge

H

| Ionizing cartridge

I

| Flow restrictor

J

| Tank valve

K

| Tank

L

| Faucet

1

| Clean water outlet

2

| Pollutants outlet

3

| Water supply to the four-way valve from the elbow connector “OUT” in the third housing

4

| Clean water supply to the four-way valve through the membrane

5

| Water outlet from the valve to the membrane

6

| Clean water outlet from the valve to the in-line cartridge with activated carbon

Water supply to the filter from the FT03 or FT07, FT06 connection (option)

a) Outlet for contaminations
– connection with the outlet clamp SC500B14

10.4. System flow diagram RX-AFRO4-ECO2

A

| Water supply to the first housing
---|---

B

| Water supply to the second housing

C

| Water supply to the third housing

D

| Housing with the RO membrane

E

| Four-way valve

F

| In-line cartridge with activated carbon

G

| Flow restrictor

H

| Membrane protection valve – clean water outlet

I

| Membrane protection valve – clean water outlet

1

| Clean water outlet

2

| Pollutants outlet

Water supply to the filter from the FT03 or FT07, FT06 connection (option)

a) Outlet for contaminations
– connection with the outlet clamp SC500B14

10.6. System flow diagram RX-AFRO5-ECO

A

| Water supply to the first housing
---|---

B

| Water supply to the second housing

C

| Water supply to the third housing

D

| Housing with the RO membrane

E

| Four-way valve

F

| In-line cartridge with activated carbon

G

| Flow restrictor

H

| Membrane protection valve – clean water outlet

I

| Membrane protection valve – clean water outlet

J

| De-ionising line cartridge

1

| Clean water outlet

2

| Pollutants outlet

Water supply to the filter from the FT03 or FT07, FT06 connection (option)

a) Outlet for contaminations
– connection with the outlet clamp SC500B14

11. The book service inspections

NAME, SIGNATURE AND STAMP OF THE AUTHORISED DISTRIBUTOR

/      /| FIRST START| SERVICEMAN| REPLACEMENT CARTRIDGES

REPLACEMENT MEMBRANES

OVERVIEW WARRANTY

---|---|---|---
/      /| COMPLETE OVERVIEW| STAMP
/      /| REPAIR
/      /| HYGIENISATION
/      /| OTHER
/      /| COMPLETE OVERVIEW| SERVICEMAN| REPLACEMENT CARTRIDGES

REPLACEMENT MEMBRANES

OVERVIEW WARRANTY

/      /| REPAIR| STAMP
/      /| HYGIENISATION
/      /| OTHER
/      /| COMPLETE OVERVIEW| SERVICEMAN| REPLACEMENT CARTRIDGES

REPLACEMENT MEMBRANES

OVERVIEW WARRANTY

/      /| REPAIR| STAMP
/      /| HYGIENISATION
/      /| OTHER
/      /| COMPLETE OVERVIEW| SERVICEMAN| REPLACEMENT CARTRIDGES

REPLACEMENT MEMBRANES

OVERVIEW WARRANTY

/      /| REPAIR| STAMP
/      /| HYGIENISATION
/      /| OTHER
/      /| COMPLETE OVERVIEW| SERVICEMAN| REPLACEMENT CARTRIDGES

REPLACEMENT MEMBRANES

OVERVIEW WARRANTY

/      /| REPAIR| STAMP
/      /| HYGIENISATION
/      /| OTHER
/      /| COMPLETE OVERVIEW| SERVICEMAN| REPLACEMENT CARTRIDGES

REPLACEMENT MEMBRANES

OVERVIEW WARRANTY

/      /| REPAIR| STAMP
/      /| HYGIENISATION
/      /| OTHER

Copyright 2015 Marketing H2OO.
All rights reserved. XI-RO-H2OO
www.h2oo.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals