PHILIPS 929002721913 DC Fit LED Tube Installation Guide

June 13, 2024
Philips

929002721913 DC Fit LED Tube
Installation Guide

929002721913 DC Fit LED Tube

PHILIPS 929002721913 DC Fit LED Tube

Philips DC-Fit LED tube s designed to operate on DC voltage with a remote Philips approved DC driver.This installation guide provides important installation steps for proper safe operation and installation of Philips DC- Fit LED tube. If you have any questions or comments, please feel free to contact Signify at 1800-555-0050 (USA), 1800-668-9008 (Canada).
Please note the important points below:

  • Philips DC-Fit LED lamps are suitable to replace TL fluorescent lamps
  •  Philips DC-Fit LED lamps require shunted T8 G13 /TS GS lamp holders
  • Philips DC-Fit LED lamps are intended for use in conjunction with a DC driver. Please do not connect the lamp directly to an existing fluorescent ballast or 120VAC / 277VAC / 347VAC
  •  Philips DC-Fit LED lamps & Philips LED drivers are sold separately. Do not operate Philips LED lamps without the corresponding Philips LED driver
  • Philips DC-Fit LED lamps package includes instruction guide, label and DC-Fit LED lamp. Installers need to prepare the additional UL qualified connecting wires or resistors to complete the rewiring based on the diagram

Application

Before Installation, please select the Philips DC-Fit LED tube and LED driver that best fits lumen output needs based on the driver list table below.

  1. Determine lamp lumen/wattage in the fixture.

  2. Locate the LED tube and DC driver product type. The selection is based on:
    a.Number of lamps per fixture
    b. Lumen/wattage objectives
    c. LED tube color temperature

  3. Dimming is only possible with Philis approved DC driver and 0-10V dimmer. The details are referred to DC driver instructions.

Now the LED lamp and LED driver combinations are defined for optimal lumen output(s) and energy usage.

120V~277V Driver List

Driver 4ft T8 4ft TS
12NC Product Code Switch
position 2 lamps 3 lamps
929002721913 CIO22C045VO48CDX1 M on
16001m NA NA
NA NA NA
off NA NA
929001791513 CIO26CO55VO48CDX1 M on
25W 35501m NA NA
off NA NA
929001799413 CI031C064VO48CDX1M on
21001m NA NA
21001m NA NA
off NA NA
929002722513 C1032C065VO48CDX1M on
16001m NA NA
NA NA
off NA NA
929001791813 CI045C093VO48CDX1 M on
16001m NA NA
21001m NA
off NA 14W
2100Im NA NA
929002710713 CI055C115VO48CDX1M on
off NA NA
929002710813 C1065C135VO48CDX1M on
off NA NA
21001m NA NA

21001m

347V Driver List

Driver 4ft T8
12NC Product Code
929000775113 XG040C110V054BST1
1500 14W/2100Im
1800 NA
929000775213 XG054C150V054BST1
3000 NA
929000775313 XG075C200V054BST1

INSTRUCTIONS

PHILIPS 929002721913 DC Fit LED Tube - instuletion

  1. Switch-off power to the luminaire I

  2. Remove diffuser (if provided) and existing fluorescent lamps !

  3. Remove the following from the luminaire ‘
    – Ballast cover plate ;
    – Ballast 1

  4. Philips DC-Fit lamps require SHUNTED lamp holders. If needed, replace non-shunted lamp holders with shunted ones. If shunted lamp holders 1 are already installed inspect the lamp holders to ensure that they are not damaged, corroded, charred, blackened, or loose, If required, Philips l recommends that the lamp holders be replaced/tightened. !

  5.  Secure the LED driver to the fixture by using existing ballast mounting holes and screws. If the driver does not fit in the existing holes, use self-tapping screws (not provided) to create new mounting holes. If multiple drivers are used in the same luminaire, additional mounting holes will be needed. Wire the driver based on the diagrams below that fits in your requirements. 1

  6. Bundle wires neatly and reattach the driver cover plate (removed in step 3). 1

  7. Insert the Philips DC-Fit LED lamp(s) into the lamp holders. Reinstall diffuser (if removed from step 2) ‘

  8. Please affix the provided label on the retrofitted luminaire so that it is visible during normal maintenance or future lamp replacement. !

  9. Switch-on power to the luminaire.

Diagram

Single lamp wiring

PHILIPS 929002721913 DC Fit LED Tube - diagram Multi lamp wiring (parallel)

PHILIPS 929002721913 DC Fit LED Tube - diagram2

« Adjust ON-OFF switch on DRIVER based on the application when it is working with 120-277V Driver.PHILIPS 929002721913 DC Fit LED Tube -
diagram3

  • Connect the register between ORANGE and GREEN when ict is working with 347V Driver. Resister Rset value is defined in the 347V Driver List table for different performance requirement and application.PHILIPS 929002721913 DC Fit LED Tube - diagram4

Luminaire Description

  • Philips DC-Fit LED tubes can’ retroft original luminaires which use remote starter.
  • Please make sure the existing luminaire dimensions are not less than dimension described in below table.

Philips LED tube intended to retrofit Max.
Number tubes in original luminaire| Luminaire Dimension with Max. No. of tubes
Length X Width X Height (cm)
---|---
Max. 6pes LED tubes( 48″) can be operated in a luminaire  with or without diffuser| 123 x 58x 8.2 cm

WARNINGS and CAUTIONS

  1. WARNING — RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRES WIRING, POWER SUPPLY, OR OTHER ELECTRICAL PARTS MAY BE DAMAGED WHEN DRILLING FOR INSTALLATION OF RETROFIT ASSEMBLY HARDWARE. INSPECT WIRING AND COMPONENTS FOR DAMAGE.

  2. WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE’S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED PERSON,

  3. WARNING — RISK OF FIRE OR ELECTRIC SHOCK. INSTALLTHIS KIT ONLY IN THE LUMINAIRES THAT HAS THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS AND
    WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOT EXCEED THE INPUT RATING OF THE LUMINAIRE.

  4. ONLY THOSE OPEN HOLES INDICATED IN THE PHOTOGRAPHS AND/OR DRAWINGS MAY BE MADE OR ALTERED AS A RESULT OF KIT INSTALLATION. DO NOT LEAVE ANY OTHER OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS.

  5. WARNING ~TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS.

  6. THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE

  7. INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.

  8. INSTALLERS SHOULD NOT DISCONNECT EXISTING WIRES FROM LAMPHOLDER TERMINALS TO MAKE NEW CONNECTIONS AT LAMPHOLDER TERMINALS. INSTEAD, INSTALLERS SHOULD CUT EXISTING LAMPHOLDER LEADS AWAY FROM THE LAMPHOLDER AND MAKE NEW ELECTRICAL CONNECTIONS TO LAMPHOLDER LEAD WIRES BY EMPLOYING CONNECTORS SUITABLE FOR THE APPLICATION.
    INSTALLERS SHOULD EXAMINE ALL PARTS THAT ARE NOT INTENDED TO BE REPLACED BY THE RETROFIT KIT FOR DAMAGE AND REPLACE ANY DAMAGED PARTS PRIOR TO INSTALLATION OF THE RETROFIT KIT.

  9. TYPE C LAMP – Intended for operation in luminaires with traditional fluorescent-type lampholders wired to an integral LED driver. This includes both factory-wired luminaires as wellas those converted for this purpose nder a retrofic program.

  10. THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS

  11. 0NLY USE THE CONTROL PROVIDED WITH OR SPECIFIED BY THESE INSTRUCTIONS TO CONTROLTHIS LAMP.
    THIS LAMPWILL NOT OPERATE PROPERLY WHEN CONNECTED TO A STANDARD (INCANDESCENT) DIMMER OR DIMMING CONTROL.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmul interference to radio communications;
Operation of this equipment in a residential area is likely to cause harmul interference in which case the user will be required to correct the interference at his own expense.
“This device complies with Part15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation s subject o the following two conditions: (1) This device may not cause harmul interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

© 2023 Signify Holding ®Ignify
Signify reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
01/16/23 www.philips.com/lighting
Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. and are used under license
Signify
North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807, USA
Imported by: Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Tel.: 800-668-9008
0000000000