LINEEYE LE-170SA OMEGA Soldering Unit User Guide

June 13, 2024
LINEEYE

LINEEYE LE - logo

DATA LINE MONITOR
LE-170SA
Quick Start Guide

Thank you for your purchase of LE-series.
This booklet tells you only the basic operation. For more detailed information, please refer to the instruction manual (PDF) in the utility CD attached to the product.
When you unpack the product, make sure you have all following items

Line Monitor| 1|
---|---|---
Dsub 9pin Monitor Cable (LE-009M2)| 1|
10pin External Input/Output Cable (LE-10ES1)| 1|
Micro USB Cable| 2| (Battery installed)
AA-sized NiMH batteries| 1|
Utility CD| 1|
Carrying Bag| 1|
Quick Start Guide (this booklet)| 1|
Warranty, Registration Card| 1|

Please let us know if you find any damage to the product or accessories lacking
It is prohibited to reprint or duplicate any part of this manual without prior permission from LINEEYE
The content of this manual and specification of the product is subject to change without any notice.
< 3rd edition >
2019 by LINEEYE CO,, LTD . All rights reserved

Safety Information

Please do not use the line monitor in the following conditions [Description of the symbol and mark] Warning : There is a possibility of getting hurt, such as a death or a serious injury.
caution : There is a possibility of getting injured or damaging the product.

Warning

  • Do not disassemble, modify or repair the line monitor.
    This may result in an injury, electric shock, and ignition

  • Turn off the power and unplug the line monitor immediately when emanating smoke or odor.
    Continuous use may result in an electric shock, burn and ignition

  • Do not use the line monitor if there is inflammable gas.
    This may result in ignition and explosion

  • Turn off the power and unplug the line monitor immediately when liquid or foreign substance gets into the line monitor.
    Continuous use may result in ignition, electric shock and malfunction.

  • Do not touch the line monitor with wet hand.
    This may result i an electric shock and malfunction

  • Do not put the line monitor in a fire or place near the heater.
    This may result in an injury, ignition and explosion.

  • Do not use the batteries other than Ni-MH batteries or alkaline batteries.
    This may result in generation of heat, ignition, leaking and malfunction.

caution

  • Do not give a strong impact to the line monitor.
  • Do not place the line monitor in following conditions.
    •  Not flat or vibrated place.
    • Temperature or humidity is above the specification.
    • Change the temperature rapidly.
    •  Have a direct sun or near the fire.
    • Magnetic field. Have static electricity.
  • Do not use the line monitor near the following devices.
    • Medical device, such as a heat pacemaker.
    • Automatic control devices easily affected by radio waves.
    • Devices controlled by the radio waves.

Nomenclature

LINEEYE LE 170SA OMEGA Soldering Unit -

Name Function
1) Power Switch
2) [Run] key
3) [Stop] key
4) [ Menu ] key
5) [ Esc ] key
6) LCD
7) Line State LED
8) Power LED

Light in red: battery full charged. Blink in red: Still charging the battery.
9)| Battery Cover| Open when changing the batteries.
10)| USB Device Port| Micro-USB connector.
Connect to the USB port of PC or USB battery charger
11)| USB Host Port| Standard A USB connector. Connect to the USB flash drive.
12)| CAN port| Measurement port for CAN.
13)| LIN/External signal port| LIN port/ External signal input/output port.

Power and Battery

This line monitor drives by batteries or bus power from a USB port.

LINEEYE LE 170SA OMEGA Soldering Unit - LINEEYE LE 170SA OMEGA Soldering
Unit

Open the battery cover and insert the attached Ni-MH batterics.

LINEEYE LE 170SA OMEGA Soldering Unit - Soldering Unit

Ni-MH batteries are used for time IC and memory IC.
To charge the Ni-MH batteries, use the battery charger for AA sized Ni-MH batteries
LINEEYE has confirmed it works with “BQ-CC23” or “BQCCS5” of
Panasonic, and “TNHC-34SMC” or “TINHC-34HBC” of Toshiba
The line monitor is able to charge the Ni-MH batteries by appropriate settings
Do not insert the alkali batteries to charge

Waming (when using the line monitor with batteries)

  •  Do not short the electrode of batteries.
    It may cause the generation of heat, ignition, explosion, leaking and ‘malfunction

  • Use the batteries and battery charger which LINEEYE recommends.
    If not, it may cause the generation of heat, ignition, electric shock and ‘malfunction

  • Do not leave the batteries near children.

  • Do not charge the Alkali batteries.
    It may cause leaking, generation of heart, explosion and malfunction.

  • Do not touch directly when leaking the batteries.
    It may result in serious injury, such as losing eyesight

Operation

There are 5 keys and touch panels to control the line monitor.
Touch panels enable to select settings by soft touch or to scroll the display by swipe.

LINEEYE LE 170SA OMEGA Soldering Unit - fig1

Basic operations are made by key operations. Pressing 2 keys simultancously have the special functions.

Operations Function
Turn On/ Off the power of line monitor.

Press longer when turning off.
[Run]| Start monitoring/ simulating
[Stop]| Stop monitoring/ simulating.
Scroll data (forward).
[Menu]| Display the top menu.
[Esc]| Return to the previous display.
Scroll data (backward).
Stop updating data on the display while
measuring.
[Menu]+[Esc]| Capture the screen image in the USB flash
drive. ( 1)
[Menu]+[Run]| Make brighter the screen.
[Menu]+[Stop]| Make darker the screen.
[Esc]+Turn on the power| Initialize the settings. Clear all.
[Stop]+[Run]+Turn on the power| Start the firmware loader. (
2)

1: Insert the USB flash drive into the USB host port.
2 Toupdate the firmware, it is necessary fo use the PC

Initial Settings

Press [ ] to turn on the power. Select the language and set date & time.

LINEEYE LE 170SA OMEGA Soldering Unit - fig2

Press [Menu] key to set the initial settings.

LINEEYE LE 170SA OMEGA Soldering Unit - fig3

Function Select a function
CAN Configuration Select basic communication conditions
LIN Configuration Select basic communication conditions
Trigger Select trigger factors and actions. Set the timer/counter for trigger

function
Record control| The setting of how to use the capture buffer, time stamp, idle time, recording condition of the line state, Auto save function, Auto backup function, and Auto measurement condition
System Settings| Select a mode for power saving, battery charging and so on

Set “Function”, “CAN Configuration” and “LIN Configuration” according to the target device and interface.

e CAN monitor
Function: Monitor
CAN Configuration: 500Kbps, sample point 75%

LINEEYE LE 170SA OMEGA Soldering Unit - fig4

e.g LIN monitor
Function: Monitor
LIN Configuration: 9600bps, ID filter “None”

LINEEYE LE 170SA OMEGA Soldering Unit - fig5

e.g: CAN Simulation
Function: CAN Simulation

LINEEYE LE 170SA OMEGA Soldering Unit - fig6

Set the communication condition in “CAN Configuration”
Touch “Tx-frame registration” and register test data to send

eg: LIN Simulation
Function: LIN Simulation

LINEEYE LE 170SA OMEGA Soldering Unit - fig7

Master or slave simulation is possible.
Set the communication condition in “LIN Configuration”
*Touch “Tx-frame registration” and register test data to send

Connect to the Target Device

[Connect to CAN interface] Connect the CAN port of analyzer and target device using the attached monitor cable.

LINEEYE LE 170SA OMEGA Soldering Unit - fig8

Dsub9 Pin (female)

Pin| Signal name| Input/output’| Description
Monitor| Simulation
1| –| –| –| Non-use
2| CAN| I| I/O| CAN bus signal
3| GND| –| –| Signal ground
4| –| –| –| Non-use
5| FG| –| –| Field ground
6| –| –| –| Non-use
7| CAN+| I| I/O| CAN bus power
8| –| –| –| Non-use
9| PWR| I| I| CAN bus Power
2

*1: “T” indicates “input to analyzer” and “O” indicates the “output from analyzer”.

2: LED of “BAT1” lights when using the bus power.

[Connect to LIN interface] Connect the LIN port of analyzer and target device using the attached cable (10 pin external input/output cable) or optional cable (5-lines probe cable, “LE-5LS”).

MIL box type lOpin cable Cable color

Signal
name| Description| Pin|
Input/output3| LE-10ES1| LE-5LS
Monitor| Simulation
All| External Inputl
4| 1| I| I| Brown| Brown
AI2| External Input24| 3| I| I| Orange| Red
A13| External Inputr| 5| I| I| Green| Orange
AI4| External Inpute| 7| I| I| Purple| Yellow
GND| Signal Ground| 9| –| –| White| Green
GND| Signal Ground| 2| –| –| Red|
OT| External Trigger Output| 4| 0| 0| Yellow|
IN| External Trigger Input| 6| I| I| blue|
LIN| LIN bus signal| 8| I| I/O| Gray|
VP| LIN bus power
5| 10| I| I| Black|

1: 2 lines 2 54mm pitch. Equivalent to “HIF3FC-10PA-2 54DS(71)” of HIROSE Electric. CO., LTD.
2 – Lead colors of attached cable (LE-10ES1) and optional cable (LE-SLS)
3 . “I” indicates “input to analyzer” and “O” indicates the “output from analyzer
4 . Analog voltage range 0 — 52V (AD resolution 12bit) Digital logic: VIH2 3V (Min)/ VIL 0.8V (Max)
*5 . LED of “BAT2″ lights when using the bus power.

LINEEYE LE 170SA OMEGA Soldering Unit - fig10

To use the analyzer near the device easily affected by radiation noise, use the shielded cable or add the ferrite core.

Measurement Start and Stop

Press [Rua] to start measuring.
[Monitoring] The line monitor displays the communication data in real time and records data in the capture buffer.

LINEEYE LE 170SA OMEGA Soldering Unit - fig11

[Simulating] It displays the monitored data and sinwlates data registered in the data table.

LINEEYE LE 170SA OMEGA Soldering Unit - fig12
Able to select the transmission data by pressing [Menu] or [..] displayed in the bottom
Register data from [Menu] [function] [CAN Simulation] or [LIN Simulation] [Tx- data registration] Press [Stop] to end measuring.
It is able to stop measurement automatically by setting the trigger or capture ‘memory setting (full stop).

LINEEYE LE 170SA OMEGA Soldering Unit - fig13

Each data is displayed in specific colors. CAN frame -> yellow. LIN frame > green External input data -> white.

1) Measuring [ ] Pause [ ]
2) Position of data/ all data. Able to type the position to display.
3) Other status
4) Selected Mode

[CAN/LIN]: Monitor CAN/LIN
[CAN sim]: Simulate CAN
[LIN master]: LIN master simulation
[LIN slave]: LIN slave simulation.
5)| Status of USB device mode (Green: Connected)
6)| Status of Host port (Green: Connected)”
7)| Level of remained battery [ ]indicates “bus power”
8)| Selections of other menu.
9)| Change display mode of measured data.
Data display -> Analog display of external input.
10)| Other operations.

*1: Itbecomes inred while accessing to the USB flash drive.
Swipe down the display to see the later (new) data,
Swipe up the display to see the earlier (old) data.
Swipe quickly to scroll data fast. It is able to type any mumbers in (2), to check ata in different positions.

[Display]

Display Description
Time stamp Time of receiving frames (H/M/S/ms) **( : Matched with

trigger condition)
SyPID| Sync byte field and Protected ID field of LIN (in HEX).
ID| Standard/ expansion ID of CAN, or LIN frame ID (in HEX).
Type| Frame type.
|
Data| Data frame of CAN.|
Remote| Remote frame of CAN
Frame| Frame of LIN.
Illegal| Illegal frame of LIN
|
Unknown data on the LIN bus.
—-| Supplemental data for external input.
DLC| Data length code of CAN, or DLC set in the LIN configuration (in decimal).**

(If frame end time is set as “time” in LIN Configuration, this will not be displayed.)

St| Frame status.
| | Normal frame.
| | Sync Byte Field error of LIN (other than 55h).
| | Parity error of LIN.
| | Long data error of LIN.
| | Non-response data of LIN (less than 1 byte)
| | Checksum error of LIN.
Data| Data field (in HEX).
C| Checksum of LIN (HEX).
T1234| External trigger or external inputs (0: Low, 1:High)

Other display
 06: Hex data in red color stands for the framing error

Useful Functions

  •  Trigger Function
    Trigger function is for starting a specific action upon occurrence of a specific facetor as a trigger.

e.g.: Stop measuring when detecting a “ID=023″ CAN frame.
Press [Menu] [Trigger]  Mark on “Trigger0”to turn on the trigger function

LINEEYE LE 170SA OMEGA Soldering Unit - fig14

Touch “F a ¢ t 017 of the trigger 0 and select “CAN data” and then touch “IDsetting” and set ID=023 in binary.

LINEEYE LE 170SA OMEGA Soldering Unit - fig15

Back to the trigger setting display by “Esc™ and touch “Action” of the trigger 0, then select “Stop Measurement”.

LINEEYE LE 170SA OMEGA Soldering Unit - fig16

¢.g.: Output a pulse to the external device when receiving a specific error,
Trigger Factor : Error
Trigger Action : TRGOUT pulse output Output a low pulse for about 1 msec from the external trigger  terminal OUT.

  •  Auto save
    Measurement data is erased when turning off the power of line monitor. Auto backup function saves data of capture buffer in the USB fiash drive.
    LINEEYE LE 170SA OMEGA Soldering Unit - fig18
    Operate [ MENU ], [Record control] and [Auto save] in order.

  • Auto backup
    When the measurement is stopped, the function automatically saves the data of the capture memory into the built-in SRAM which is backed up by the battery (for about 30K bytes of the data which was recorded at last) or into the USB memory (all the data of capture memory to the AUTOBULDAT file),
    LINEEYE LE 170SA OMEGA Soldering Unit - fig19

  • Time specified auto RUN / STOP function
    You can execute automatic measurement repeatedly of a specified period repeatedly or start measurement in conjunction with the turn- on of the power.LINEEYE LE 170SA OMEGA Soldering Unit - fig20

Operate [ MENU ], [Record control] and [Auto save] in order.

Specification

Item| LE-170SA Ii
---|---
Interface| CAN (IS011898) / LIN (I509141)
Protocol| CAN 2.0LIN (Rev. 1.1, 1.2, 1.3, 2.0, 2.1)
Communication speed(bps)| CAN: 20kbps to 1MbpsLIN: 400bps to 26kbps
Capture memory| 16M bytes (about 500K data)

Two-division use and automatic backup at the end of measurement are available

Monitor function|

Standard/extended format are supported, bit receiving timing can be set, filtering is available, arbitrary speed can be set.

Divides the frame by specified time pass or ID setting, filtering is available, arbitrary speed can be set.

Simulation function| Test data transmission (data sweep is available.)
functions Additional                “| Auto save function, Time specified auto RUN / STOP function, power-on RUN function.
External Trigger| Input 1, Output 1
External input| 4 Measurement of 4 signals. Range: 0 to 52V. Resolution: 12 bit. Digital threshold: VIH 2.3Vmin. VIL 0.8Vmax.
Display| 4.3 inch TFT color display (480x272dot)28 characters x 6-stage display.
Touch panel| Capacitive touch screen
USB2.0 device port| Micro B connector.
USB2.0 host port| Standard A connector. For USB flash drive.
Power| USB bus power 5V/500mA, two AA Ni-MH batteries, or two AA alkaline batteries
Drive time e7)| AA sized Ni-MH batteries: about 5 hours AA sized alkaline batteries: about 2 hours
Temperature & humidity| In operation: 0 to +40°C, In storage: -10 to +50°C, 20 to 85%RH (No condensation)
Standard| CE (class A), EMC (EN61326-1:2013)
Size & weight| 158mm x 100mm x 31mm, 300g(including batteries)

1: Firmware Ver.101 or later.
2 – Under the normal operation.

Warranty and After Service

Warranty

  •  Trouble
    Contact the distributor or LINEEYE.

  • Warranty Card
    The warranty card is attached to the product.
    Confirm the content and fill out the blanks and keep it.
    ‘Warranty period: 1 year from the purchase (Does not include the one for the software.)

User registration
For the after support and the information for the product please register your product from LINEEYE website.

Repair

  • Although the configuration and setting is checked and are correct but the product does not work well, contact us with the detailed information.
Model LE-170SA
Serial number 8 digits number of Serial No.
Purchase date Day/month/year
Situation More detailed information is appreciated.
  •  Repair within the warranty period
    We will repair it following our warranty policy. First please inform us the situation and then send it back to us with the warranty card.

  •  Repair after the warranty period
    We will repair the product when the repair is possible. Check the price guide in our website and then send it back to us with the repair request document.

Memo

For any technical issues
Read “FAQ” in our website or email us. https://www.lineeye.co.jp/html/contact.html

LINEEYE CO., LTD.
4F., Marufuku Bldg., 39-1, Karahashi Nishihiragaki-cho, Minami-ku,
Kyoto, 601-8468, Japan
Tel : 075(693)0161 Fax:075(693)0163
URL https://www.lineeye.co.jp
Email : info@lineeye.co.jp
Printed in Japan
M-32170SAQE/LE

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals