LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual

June 13, 2024
LINEEYE

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual

LINEEYE LE PC800X Multi Protocol Analyzer Instruction
Manual

Instruction Manual

The CD-ROM attached contains the English and Japanese instruction manuals in PDF format. The actual display or manner of operation may differ from that of the instruction manual because of the improvement of the product and so on. Please refer to the online help also for the use of the software.
The 1th Edition

Chapter 1 Before Using the Product

Software License Agreement
LINEEYE CO., LTD (LINEEYE) grants you to use the software program and the documents under the terms of this license. And you are consenting to be bound by and are becoming a party to this agreement. To use the software, you need to agree to this license agreement.

  1. Copyright LINEEYE holds the copyright on this software.
  2. Grant of License LINEEYE grants for you to use this software on only one computer by agreeing this license agreement. Therefore, you shall not rent, lease and loan to a third party.
  3. Copy, Analysis, Modification This software must not be reproduced, analysed or modified in any form unless prescribed in the manual.
  4. Upgrade This software may be upgraded without any advance notice because of technical progress of hardware or software. LINEEYE provides the upgraded software with the upgrade fee. For upgrade, only licensed user can have upgrades.
  5. Limitation of Liability In no event shall LINEEYE or its licensors be liable for any loss of business or profits, or for any direct,indirect, incidental or consequential damages arising from products of this software or the related software. Besides LINEEYE shall not be liable damages arising from the equipment.
  6. General If any provision of the agreement is held invalid, such provision shall be removed from this license agreement.
  7. Support LINEEYE supports functions, operation and only the problem on this software.
  8. Notice Any matter not specified in this agreement will be governed by and constructed in accordance with copy right law and related laws.
    LINEEYE CO., LTD

Chapter 2 Introduction

Thank you for your purchase of LINEEYE’s PC link software.

  • To use it correctly, you are advised to read and understand this together with the instruction manual for analyzer thoroughly.
  • Keep this instruction manual.
General Description

LE-PC800X is software to remotely control the protocol analyzer from a PC and utilize the measurement data on the PC.
Applicable Analyzer LE-8500X-RT, LE-8500XR-RT, LE-8500X(R)/LE-8600X(R) equipped with SB-R2TS1.

Unpacking

When you unpack the product (the full edition), make sure that the followings are included. (The light edition of the software is included in the CD-ROM attached to the analyzer.)

  • CD-ROM (software) 1
  • Instruction Manual (This book) 1
  • User Registration Card 1

Please contact your LINEEYE distributors if you find any damage to the product caused by transportation, or if there are accessories lacking.

Chapter 3 Before Start-up

USB Driver Installation

When using this software by USB connection, connect the USB port of PC and analyzer using the USB cable before using it.

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - USB Driver
Installation

Confirm the IP address of analyzer.

When using this software by LAN or Wi-Fi (appropriate model only), confirm the IP address and port number of analyzer before using it.
Please refer to the instruction manual of analyzer. (Refer to “Network” on “System setting”)

Installation Guide
  1. Execute “setup.exe” in the attached CD.
    If the PC (to which you want to install the software) does not have a CD-ROM drive, copy it to a storage device such as USB flash using another PC which has a CD-ROM drive to bring it to the PC and execute it.

  2. First, click “Yes” in the “User Account Control” display.

  3. When the Windows firewall displays a message such as “Windows protected your PC”, click “Detail”” Run” to run the program.

  4. Even if the virus security software displays a message that blocks this software, click the option to run the software such as “Run this program” to cancel the blocking.

  5. When the installer starts up, proceed according to the instructions on the screen. You will be prompted for the serial number during installation. Please enter the serial number of this software written on the attached user registration card.LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - When the installer starts up
    For the light version “LE-PC800X (LITE)” which you can download free of charge from the
    LINEEYE website, the serial number will be automatically entered as “LITE”.

  6. When the installation completion message is displayed, click “Finish”.

Uninstallation Guide
  1. Open “Uninstall or change a program” (or “Program and Features”) from the control panel. (Or right-click on “LE-PC800X” in the start menu and select “uninstall”.)
  2. Select “LE-PC800X” from the list and execute “Uninstall and change”.
  3. First, click “Yes” in the “User Accounts” display. 4. Click “OK” at the deletion confirmation display.
    When the light version “LE-PC800X (LITE)” is already installed in the PC, uninstall the light version before installing the full version.
    When updating the product version (full edition), you can install the new version without uninstalling the old version. By doing so, the product serial number etc. will be carried over.

Chapter 4 Data Window

Data Window of PC link software

Starting the PC link software. Start “LE-PC800X” from the “Start” of Windows. Usually, the following display will appear.
Data Window
LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Data Window
of PC link software

  1. Menu Can perform various operations.
  2. Tool Bar Can perform various operations.
  3. Data display part Displays the measured data.
  4. Data position display part Displays the data position in the Data display part. The number of data loss is displayed while remote monitoring.
  5. Various state display part Displays such as the measurement state.
  6. Connection state display part Displays the remote connection state between LE-PC800X and your analyzer.
  7. Model name display part Displays the model name of your analyzer being set at the time of offline, and one of your analyzer being connected at the time of online.
  • For LE-8500X-RT, “LE-8500X+SB-R2TS1” is displayed.
    For LE-8500XR-RT, “LE-8500XR+SB-R2TS1” is displayed.
    Refer to the “On-Line Help” for more details of operation.

Chapter 5 Environment Setting

Remote Setting

Click   on the tool bar of the data window (or “Remote Setting” of “Remote” menu) to set the remote setting. The remote setting consists of “Connection”, “Model selection”, “Key emulation” and “Miscellaneous”.

Connection
Sets the remote connectionLINEEYE LE PC800X Multi Protocol Analyzer
Instruction Manual - Connection

“Connection Method” “USB” Connect via USB port. (Select the serial number of analyzer which you wish to connect.)
“LAN/Wi-Fi(TCP/IP)” Input the IP address (or host name) of analyzer to “host name”, and the port number of analyzer to “data port”.

Model selection
Sets your analyzer settings. Mainly, it is used at the time of offline. However in the case of that there is information which is not received by remote communication at the time of online, it is used as it is set. In addition. if the information is received by remote communication, these settings are automatically changed.

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Model
selection

“Analyzer model”
Selects the model name of the target analyzer.
“Expansion board”
The expansion board which is equipped with the analyzer is displayed.

■Remote monitor
Sets the remote monitorLINEEYE LE PC800X Multi Protocol Analyzer Instruction
Manual - Remote monitor

“A folder to save the remote monitor data” This folder is to save data received by your analyzer for the remote monitor function. To change the setting, click “Change” button. Then the window to select a folder appears. Select the proper folder and click “OK” button. The file name of saving data is started from “00000000. DT” in numerical order.

  • Recommends to specify an exclusive folder.
  • Specify a drive which has enough capacity. (When it does not have enough capacity, the PC may not operate correctly.)

“Block size”
Sets the data capacity per file. You can select from “1M Byte”, “2M Byte”, “4M Byte”, “8M Byte”, “16M Byte”, “32M Byte”, “64M Byte”, or “128M Byte”.
“Maximum block count”
Sets the maximum block count of a file to save. You can set from 2 to 2048. When the number of the data file is over this setting, the data file with a small number file is deleted.

“Full stop”
If the stored files reach to the maximum block count, measurement will automatically stop. When unchecked, a ring buffer of the size obtained by multiplying the block size by the maximum number of blocks is configured and continuous measurement is performed. -9-

“Append mode”
When measurement starts, a newly-created file is saved in the order after the existing files. If the numbers of the whole data files are over the maximum block count setting, a data file with a small number file (includes data files which were saved on the former measurement) is deleted even in the append mode.

“Change file by elapsed time”
Create a new data file when the specified time has been elapsed, even if the size of the former data file has not reached the specified Block size. However, if the data file under recording has not recorded any data, the new data file will not be created.

“Warning display”
You will be warned if there is a data file in the files to save when starting measurement.

“Key emulation”
Sets the key emulation.

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Key
emulation

“A folder to save the screen capture data”
A folder to save a screen image when you save it on the key emulation screen. Click “Change” button and the folder selecting window appears. Select the folder and click “OK”.

“Miscellaneous”

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual -
Miscellaneous

“Settings synchronization” Transmits and receives the setting automatically a the time of the opening and closing the analyzer setting window. If you mark on “Disable automatic setting receive”, you only transmit and do not receive.

“Simulation programs transmission”
The setting data to be sent to or be received from the analyzer contains simulation programs data when this term is marked.

Chapter 6 Remote Monitor

This function allows to start measurement of your analyzer and to record measurement data in the HDD/ SSD of the PC, displaying the data in real time.

Connection

After finishing the remote setting, click on the tool bar of the window (or click “Connect” of the remote menu) to connect with you analyzer. At the time of completing the connection with your analyzer, the connection state display part of the data window displays “Stopping”, and the model display part displays the model name of the analyzer connected.

Analyzer Setting

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Analyzer
Setting

When you continuously measure for long hours using remote monitoring, do not set “Record control” to “Full stop: On”, or “Trigger” to “Action: Stop”.
The light edition limits its monitoring time to 10 minutes.

Simulation Data Setting

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Simulation
Data Setting ![LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual

Max speed when remote monitoring

Max speed which analyzer can measure is depending on the connection to the PC. Refer to the following standard speed.

USB (USB3.0/3.1) : Max. 5Mbps
LAN : Max. 2Mbps1
Wi-Fi : Max. 1Mbps
1

*1 The max. measurement speed becomes lower by the network load. However, when measuring 10Mbps with 2K byte data for every 0.02 seconds, the actual communication speed is about 1Mbps, and you can measure this communication without any data loss.

■It will cause the data loss if the actual communication speed is more than the max. speed. And PC will stop the action until the analyzer process all measured data to the PC.
■When the measured data is lacked, will displayed on the window.
■Key emulation mode will decrease the max. speed.

Start Measurement

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Start
Measurement

Stop Measurement

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Stop
Measurement

Remote Monitor Screen

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Remote
Monitor Screen LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Remote
Monitor Screen

Read the Measurement Data

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Read the
Measurement Data

Search Data

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Search
Data

Chapter 7 Bit Error Rate Test (BERT)

Bit error rate test (BERT) can monitor the quality of communication lines in the long distance.

Start Measurement

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Start
Measurement LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Start
Measurement

Chapter 8 Key Emulation

This function allows to control the analyzer from a far place. (remote control)

Run Key Emulation

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Run Key
Emulation

  1. Displays the screen of your analyzer being connected.
  2. Emulate the key of your analyzer.
    Auto configuration function is not available from the PC link software.
Capture the Screen Image

You can save the screen image of the connected analyzer in a bitmap (BMP) file format.

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Capture the
Screen Image

Chapter 9 Text Conversion

This function allows to convert the data which is measured on the remote monitor, and which is saved on such as a memory card and HDD/SSD into a text file.

Text Conversion Function Setting

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Text
Conversion Function Setting

-Folder Specify a folder which has the data you wish to convert into text.
-File type Selects from “Data files” and “Auto save files”
-Refresh Refresh the file information in the specified folder.
-Monitor data file Selects a file you wish to convert from the list display. It is selected by clicking the file. To cancel the selection, click the file again. (You can select two or more files and cancel them all.)
The light edition limits the number of files of text conversion (at the same time) up to 3.

-Output format
Selects a format you wish to convert from the following.
“Normal” (Print format of your analyzer)
“With line state” (Print format of your analyzer which includes control line information)
“Translated” (Translated print format of your analyzer)
“CSV format (data)” (Every data divided.)
“CSV format (frame)” (Every frame divided.)

-Select data line
Selects the number of characters displayed per line from “40” ,“80”, “136” and “MAX”.

-Data format
Selects the data format to convert from the following.
“Char. / Hex.” (Displays the character code and the hexadecimal number.)
“Char. Only” (Only characters are displayed.)
“Hexadecimal” (Only the hexadecimal number is displayed.)

-No guide
If “No guide” is checked, converts such as the communication condition without guide.
(data only)

-Exclude time stamp
If “Exclude time stamp” is checked, delete the time stamp to convert.

-Exclude idle time
If “Exclude idle time” is checked, delete the idle time to convert.

-Select data line
Selects the data to convert from “SD and RD,” “SD only” and “RD only.”

-HDLC translation
At the time of HDLC, selects the translation format to convert from “Frame” and “Packet.”

-PPP translation
At the time of PPP, selects the translation format to convert from “PPP” and “DUMP.”

-Line state
At the time of “Normal print and Line state,” mark the control line to display with.
You can change the order to display, by clicking “up” and “down” button.

If the CSV conversion is selected, the following window appears.LINEEYE LE
PC800X Multi Protocol Analyzer Instruction Manual - If the CSV conversion is
selected
-Select data line Selects from “SD and RD,” “SD only” and “RD only.”
-Data format Selects from “Hexadecimal,” “Decimal” and “Character.”
-Column Sets the range between 1 and 65535.
-Delimit char. Sets the delimit character such as “,”

Start Text Conversion

Click “Convert.” A converted file is saved in the folder which contains its source file.

Chapter 10 Waveform Monitor Data

When the analyzer has logic analyzer data, the waveform monitor data is received and displayed.

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Waveform
Monitor Data LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Waveform
Monitor Data

Chapter 11 Connecting Multiple Analyzers

To connect multiple analyzers at the same time, add the necessary setting for the number of analyzers to connect.

  1. LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual - Connecting Multiple AnalyzersMenu Performs each operation.
  2. Toolbar Performs each operation.
  3. Remote Setting List Displays the remote setting.
  4. Option Setting Set the operation setting when starting.
Add the Remote Setting

To add a new remote setting to the list, click   on the toolbar of the remote setting window (or, click “new setting” of the remote menu.). Sets the necessary items. (For more information about each item of the remote setting, read “Chapter 5 Environment setting.”)
*Chapter 5 Environment Setting

  • For multiple analyzers, make sure not to specify the same folder as location of saving the remote monitor data.

When opening this setting window from the remote setting list window, you can rename the setting name. Adds the remote setting for the number of analysers you wish to connect. (It does not allow you to rename the setting name when the window opened from the data window.)

Open the Data Window

To open the selected data window for remote setting, select the specific remote setting from the list of the remote setting list window (multiple selections possible), and click   on the toolbar (or, click the “open data window” of the file menu.).

Delete the Remote Setting

You can delete unnecessary remote setting. At first, select the remote setting you wish to delete from the list of the remote setting list window (multiple selections possible) and click ❌ on the toolbar (or, click “delete setting” of the remote menu). Then, the deletion confirmation appears and the selected setting will be deleted by clicking the “OK” button. However, if the remote setting which is using in the data window, you cannot delete it. If you end the application with all the remote settings deleted, a new setting (default setting) will be automatically added when you start the application next.

Operate Setting When Starting

You can select operation when LE-PC800X starts from the following:
“The remote setting list (this window) will be opened”
The remote setting list window will be opened. If the window has already opened, it will be displayed in front.

“The data window will be opened. (Order in the setting list)”
The data window will be opened in the order according to the remote setting list. If all data windows for the remote setting have already opened, the operation is the same with “The remote setting list (this window) will be opened.”

Start-up Options

When starting the LE-PC800X, following options can be used. -r “<Setting name>”
Start measuring automatically by the specified Connection setting after starting LE-PC800X. To start measuring by the multiple settings, ex. specify as follows.

-r “Remote01” -r “Remote02” When starting the measurement by using AUTO measurement function, the warning message of loosing the existing data file will not be displayed. Also, when starting the measurement by using APPEND mode and the selected configuration file automatically, the existing data file will be erased without the warning message when starting LE-PC800X.

-q It saves measured data to the data file immediately, and try to keep the format of data file as normal. (LINEEYE does not warrant the condition is normal.) Also, it will allow to read the measured file which is in the process of saving data, and able to copy the data file. However, the data file which is in the process of saving data can not be opened by the other window of LE-PC800X. It is possible that this function will deteriorate the ability of PC or storage of saving data file. Therefore, LINEEYE does not recommend using this function.

Chapter 12 Specification

LINEEYE LE PC800X Multi Protocol Analyzer Instruction Manual -
Specification

1 Available by adding SB-R2TS1 for LE-8500X/XR and LE-8600X/XR.
2 See “Max speed when remote monitoring” on page 14 for the communication speed of the measurement target that can record the measurement data without fail on the remote monitor. The LE-PC800X (light version) included in the CD that comes with the analyzer automatically terminates the remote monitor in 10 minutes, so long-term continuous measurement cannot be used.
*3 Use with Windows® 7 is not supported.

There is a registration page on our web site. ( https://www.lineeye.com ) Please register your product for further support. We will provide you the software update information and sales information etc.

LINEEYE CO., LTD.

4F., Marufuku Bldg., 39-1, Karahashi Nishihiragaki-cho, Minami-ku, Kyoto, 601-8468, Japan
Phone : 81-75-693-0161 Fax : 81-75-693-0163 URL https://www.lineeye.com Email: [email protected]
Printed in Japan

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LINEEYE User Manuals

Related Manuals