Installation Instructions

Please note: This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with local wiring regulations.

Thermostat positioning:Danfoss-TPOne-M-Electronic-Programmable-Room-
Thermostat-including-Domestic-Hot-Water-Timer-FIG-1
\(1\)

Specifications

Specifications TPOne- M
Operating Voltage 230Vac, 50/60Hz
Output 1 (Heating) Volt Free
Setting temperature range 5-35°C
Operating temprature range 0-45°C
Switch rating 1 3A (1) at 230Vac
Switch type 1 1 x SPDT Type 1B
Output 2 (Domestic Hot Water) 230Vac
Switch rating 2 3A (1) at 230Vac
Switch type 2 1 x SPDT Type 1B
IP rating IP20
On/off control Yes
Chrono-proportional control Yes
Operating mode Heating
Construction EN 60730-2-9,EN 60730-2-7
Pollution Degree Rating Degree 2
Rated impulse voltage 4 kV
Ball pressure test 75°C
Dimensions (mm) H67 x W154 x D30
Software Classification A
Battery backup time 24 Hours

ErP Class

The products represented within this document are classified according to, and allow completion of, the Energy Related Product (ErP) Directive System Package fiche and the ErP system data label. ErP Labelling obligation is applicable from 26th September 2015.

ERP Class

|

Product Function and ErP Description

| Additional efficiency gain
| TPI Room Thermostat, for use with on/off output heaters

An electronic room thermostat that controls both thermostat cycle rate and in- cycle on/ off ratio of the heater proportional to room temperature. TPI control strategy reduces mean water temperature, improves room temperature control accuracy and enhances system efficiency.

|

2%

Mounting

Danfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(3\)Danfoss-TPOne-M
-Electronic-Programmable-Room-Thermostat-including-Domestic-Hot-Water-Timer-
FIG-1 \(4\)

Wiring

Danfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(6\)

Domestic hot water, optional timed output only
Remote sensor input

  • Remote room or limit sensor
  • Window switch contact

User Interface

Danfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(9\)Danfoss-TPOne-M
-Electronic-Programmable-Room-Thermostat-including-Domestic-Hot-Water-Timer-
FIG-1 \(10\)

Display

Danfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(11\)Danfoss-TPOne-M
-Electronic-Programmable-Room-Thermostat-including-Domestic-Hot-Water-Timer-
FIG-1 \(12\)

Setup Wizard

Danfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(13\)

Set Temperatures

Danfoss-TPOne-M-Electronic-Programmable-Room-
Thermostat-including-Domestic-Hot-Water-Timer-FIG-1
\(14\)

Setup Schedule

Danfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(15\)

Setup ScheduleDanfoss-TPOne-M-Electronic-Programmable-Room-Thermostat-
including-Domestic-Hot-Water-Timer-FIG-1 \(16\)

User Menu

Hot Water


Click & Save

Heating Mode

Schedule

Temperatures

Holiday

User Settings

Set Date


Set Time

Button Click

Backlight

Temperature Scale

Language

User Reset

Information

Installer Settings

Hot Water Setup

**Control Type
Start-up Method
Temperature Limits
****
Frost Protect
Temperature Override
Daylight Saving
****
Button Lock
Display Idle Mode
Service Interval
****
Service Demo
****
Installer Lock
Installer Reset**

Information and Warnings

Window Open

Product Lock
Optimised Start
Delayed Start
Frost Risk
Low Heat
Service Due
Heat Reduced
Sensor Fail
External Sensor Fail
Floor Sensor Fail

  • Danfoss Ltd. Unit 4 Uxbridge Business
  • Park, Sanderson Road UB8 1 DH, GB
  • Danfoss A/S
  • Climate Solutions
  • danfoss.com.
  • +45 0330 8086 888
  • customerservice.uk@danfoss.com.
  • Any information, including, but not limited to information on the selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc., and whether made available in writing,
  • orally, electronically, online, or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogs, brochures, videos, and other
  • material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to the form, fit, or function of the product. All trademarks in this material are property of Danfoss A/S or
  • Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.
  • ©Danfoss Climate Solutions 06.2023
  • AN427239761967en-000101 (013R9606)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals