CAVIUS 3106-008 Thermal Heat Alarm Installation Guide

June 13, 2024
CAVIUS

CAVIUS 3106-008 Thermal Heat Alarm

CAVIUS-3106-008-Thermal-Heat-Alarm-PRODUCT

Product Information

  • Product Name: Thermal Heat Alarm
  • Commercial Reference: 3106-008
  • Manufacturer: CAVIUS
  • Product Description: The Thermal Heat Alarm is designed for areas where smoke alarms may not be suitable due to a high risk of false alarms, such as kitchens, garages, or workshops.
  • Technical Information:
    • Detection Capability: Rapidly increased temperature level and absolute heat level of 58 degrees Celsius
    • Interlinking Capability: Up to 32 alarms within a house group
    • Alarm Dimensions: Diameter – 78mm, Height – 42mm
    • Battery Type: Non-replaceable 3V CR123A lithium battery
    • Compliance Standards: EN54-5 class A1/R, EN300-220, Kitemark BS 5446 part2

Product Usage Instructions

  1. Read the installation guide carefully before installation and retain it for future reference.
  2. Safety Instructions:
    • Handle the 3V lithium battery with care.
    • Keep battery-powered devices out of reach of children.
    • Do not attempt to recharge or burn the batteries.
  3. Mounting and Interlinking Alarms:
    • All alarms that need to be connected within the house should be put into “Learn Mode” by sliding the switch on the back of the alarm to the “Learn Mode” position.
    • Press and hold the test button on one alarm until it beeps and the LED flashes. This alarm will become the master and send out a specific house code to the other alarms.
    • As the other alarms receive the specific house code, they will also flash the LED light.
    • When the red LED light flashes on all alarms, they are connected and must be switched out of “Learn Mode” and installed.
    • Label the original Learn alarm to easily add new CAVIUS Wireless Family alarms to the system.
  4. Best Areas to Install the Heat Alarm:
    • Additional alarms increase security.
    • Note : In areas where smoldering fires occur over flaming fires, photoelectric smoke alarms are recommended.
  5. Areas Where Not to Install Heat Alarms:
    • Avoid installing heat alarms too close to ovens, hobs, or stoves.
  6. Placement:
    • Ceiling Installation:
    • Minimum 30cm from wall
    • Minimum 30cm and maximum 50cm from stove
    • Wall Installation:
    • Minimum 15cm and maximum 30cm from ceiling
    • Avoid installing too close to the oven/hob/stove
  7. Installing the Heat Alarm:
  8. Detach the alarm from the mounting base by twisting it counter clockwise.
  9. Use the mounting base ring to mark the screw holes on the ceiling or wall.
  10. Use the enclosed screws and plugs to securely mount the alarm.

Thermal heat alarm device
Commercial reference : 3106-008
Developed by CAVIUS

This Thermal Heat Alarm is designed for areas not suitable for smoke alarms due to high risk of false alarms such as; kitchens, garages or workshops.
PLEASE READ THE INSTALLATION GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

SAFETY INSTRUCTIONS

The device comes with a 3V lithium battery. Batteries are to be handled with care and battery powered devices should be kept out of reach of children.
Do not try to recharge or burn the batteries.

TECHNICAL INFORMATION:
Cavius heat alarm detects:

  1. rapidly increased temperature level
  2. absolute heat level of 58 degrees C.

The maximum number of alarms that can be interlinked within a house group are 32.
Please note: These must be alarms from the CAVIUS

  • The distance between interlinked alarms depends on the house layout and they should always be tested after installation. It is not advised to get more than 10m distance between two alarms.
  • Diameter: 78mm. Height: 42mm.
  • The alarm is powered by a non-replaceable 3v CR123A lithium battery.
  • Complies to standards: EN54-5 class A1/R, EN300-220, Kitemark BS 5446 part2.CAVIUS-3106-008-Thermal-Heat-Alarm-fig- \(1\)

HOW TO SET UP AND CONNECT ALARMS:

Please note : The product label must not be removed as it contains important information regarding the product

  • All alarms that need to be connected in the house should be put into ‘Learn Mode’ by sliding the switch on the back of the alarm to the ‘Learn Mode’ position.CAVIUS-3106-008-Thermal-Heat-Alarm-fig- \(2\)
  • The red LED will light up to indicate that ‘Learn Mode’ has been selected.
  • Please note that when the alarms are placed in ‘Learn Mode’ they can’t be inserted into the mounting base.
  • Press and hold the test button at one alarm only, until it beeps and the LED flashes. This alarm will become the master and will start sending out a specific house code to the other alarmsCAVIUS-3106-008-Thermal-Heat-Alarm-fig- \(3\)
  • As the other alarms receive the specific house code, they will also flash the LED light.CAVIUS-3106-008-Thermal-Heat-Alarm-fig- \(4\)
  • When the red LED light flashes on all alarms, they are connected and MUST BE SWITCHED OUT OF ‘LEARN MODE’ and installed.
  • Label the original “Learn” alarm in order to easily add new CAVIUS Wireless Family alarms to the system.

Siting of Heat alarmsCAVIUS-3106-008-Thermal-Heat-Alarm-fig-
\(5\)

THE BEST AREAS TO INSTALL THE HEAT ALARM:

  1. Kitchen area
  2. Garage or workshop

Additional alarms increase security.

AREAS WHERE NOT TO INSTALL HEAT ALARMS:

  • In rooms where the temperature goes outside -10ºC to +50ºC.
  • Bedrooms
  • Lounge
  • Dining room
  • Hallway
  • Family room

NOTE : In areas where smoldering fires occur over flaming fires, photoelectric smoke alarms are still the best to be installed.

PLACEMENT

The heat alarm is designed to be installed on a ceiling or wall. Do not install to close to the oven/hob/ stove (see drawing).

For wall installationCAVIUS-3106-008-Thermal-Heat-Alarm-fig-
\(6\)

For celling installationCAVIUS-3106-008-Thermal-Heat-Alarm-fig-
\(7\)

INSTALLING THE HEAT ALARM

Detach the alarm from the mounting base by twisting counter clockwise

  • Use the mounting base ring to mark the screw holes on the ceiling or the wall.CAVIUS-3106-008-Thermal-Heat-Alarm-fig- \(10\)
  • Once the mounting base is installed, attach the alarm by twisting clockwise until it clicks. If the switch is in ‘Learn Mode’, the heat alarm will not be able to click into the mounting base.

SAFETY LOCK

TEST FUNCTION:

After installation, and at least once per quarter, test all of your alarms to ensure they are operating correctly and are within range of each other.It is recommended to check visually every week if the LED flashes correctly (every 48 seconds.)
Press the test button on any alarm for 2 sweeps of alarm signal. This will send out a test signal from the alarm; all other connected alarms should receive the signal within a short time. The alarms will emit a short beep and the LED will flash every 8 seconds for 2 minutes
NOTE: Test function also allows to send a depleted
RF signal to ensure an optimal operation in normal conditions.

When the test signal is sent out, the alarms will respond in two ways:

  1. A single beep every 8 seconds indicates that the alarms are connected and functioning.
  2. Three short beeps every 8 seconds indicates a heat sensor fault.
    If required this indication can be stopped early on each alarm by a short press of the test button. If the problem continues, please visit www.cavius. com for any trouble shooting.

ADD EXTRA DEVICE

CAVIUS-3106-008-Thermal-Heat-Alarm-fig-
\(12\)

All CAVIUS interconnected alarms within the they run on the same frequency and use the same data protocol.This means that the wireless system can consist of a combination of smoke, heat etc.
Place all alarms into ‘Learn Mode’ and repeat section 1.
Always test connection to all devices by repeating test function section 7 after adding devices.
The alarm effected by the low battery will only beep, no other connected alarms will sound.

OTHER INFORMATION:

  • Do not paint the alarm.
  • Disposal: Please dispose properly at the end of life. This is electronic waste which should be recycled.
  • The heat alarm is not suitable for use as a fire safety device unless it is part of a planned fire safety system, i.e. when interconnected to one or more smoke alarm(s).
  • Complies to the Radio Equipment Directive 2014/53/EU
  • RF frekvens: 868 MHz.
  • Maximum radio-frequency power transmitted: 20 dBm
  • Full DoC to 2014/53/EU (RED) can be downloaded at www.cavius.com
  • WARNING : All alarms should be assumed as due to actual fire and the dwelling should be evacuated immediately.
  • WARNING : To prevent injury, this apparatus must be securely attached to the ceiling/wall in accordancewith the installation instructions.
  • WARNING : Batteries shall not be exposed to excessive heat such as shine, fire, or the like.
  • Note the local country regulations regarding installation.
  • The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product.
  • Tested to comply to the standard of system heat alarms EN54-5 class A1.
  • Alarm condition aural signal pattern according to ISO 8201.
  • BSI Kitemark™ certified

All Rights reserved: Cavius Aps assumes no responsibility for any errors, which may appear in this manual. Furthermore, Cavius Aps reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Cavius Aps does not make any commitment to update the information contained herein. ©2022 Carrier. All Rights Reserved. All trademarks and service marks referred herein are property of their respective owners.
Developed by CAVIUS Aps Jens Juuls Vej 28 K, DK-8260
Manufactured in P.R.C.
Contact : CAVIUS Ltd
Edinburgh, Scotland, EH3 9DQ uksales@cavius.com. www.cavius.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CAVIUS User Manuals

Related Manuals