Input: 100-240VAC/200-240V 50-60Hz
Output Voltage: 12V,24V,36V, 48V
Rated Power: 50W max

Features

  • Universal Input: 100-240V/200-240V AC 50-60Hz
  • RoHS Compliance
  • EMI Standard EN55015
  • Safety Standard: EN61347-1, EN61347-2-13, UL8750
  • Inrush current<65A AC230V/50Hz
  • High efficiency & low power consumption
  • Short Circuit, Over Current and Over Voltage Protection
  • Over temperature protection
  • 100% full load burn-in test

Application

LED strips
LED indoor lighting
LED decorative lighting
LED building lighting

Dimensions and Installation

YINGJIAO YSL100F Series LED Power Supply - Dimensions

MODEL DETAIL SPEC.| YSL50F-1204160| YSL50F-2402080| YSL50F-3601380| YSL50F-4801050
---|---|---|---|---
INPUT| Input Voltage:| 100-240VAC/ 200-240VAC
Input Frequency:| 50-60Hz
Inrush Current:| 65 Amps max. at 230VAC/50Hz,full load
AC Current:| 0.17A/230VAC
Leakage Current:| <0.25mA/240VAC
Efficiency:| 88%| 88%| 88%| 88%
OUTPUT| DC Voltage:| 12V| 24V| 36V| 48V
Rated Current:| 4.16A| 2080mA| 1380mA| 1050mA
Rated Power:| 50W| 50W| 50W| 50W
Voltage Tolerance:| ±5.0%| ±5.0%| ±5.0%| ±5.0%
Ripple and Noise:| 120mVp-p| 240mVp-p| 360mVp-p| 480mVp-p
Line Regulation:| ±3%
Load Regulation:| ±5%
Setup, Rise, Hold Up time:| 1s, 10ms/60ms 230VAC 1000ms, 1ms/25ms 115VAC at full load
ENVIRONMENTAL| Operating Temperature:| -20 ~ +50 (Refer to “Derating Curve”)
Storage Temp:| -40℃ ~ 85℃
Storage Humidity:| 20 ~ 95% RH
Working Humidity:| 20 ~ 95% RH non-condensing
PROTECTION| Over Load:| Above 105%-130% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage:| 12V:13.8 ~ 16.2V 24V:27.6 ~ 32.4V 36V:41.4~48.6V 48V:55.2~64.8V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temperature:| Shut down o/p voltage, re-power on to recover
SAFETY & EMC| Safety Regulations:| EN61347-2-13:2014+A1:2017,EN61347-1:2015;EN62493:2015
Withstand Voltage:| I/P-O/P:3750KVAC
Harmonic| EN61000-3-2 Class C EN61000-3-3
EMI:| Compliance to EN55015
EMS:| compliance to 61547:2009
OTHER| MTBF:| 200,000 Hours Minimum at Full Load at 25℃ Ambient