Raritan NX1-BHD3300 Pdu Hd Basic 0u 3 Phase 32a Instructions
- June 13, 2024
- Raritan
Table of Contents
Raritan NX1-BHD3300 Pdu Hd Basic 0u 3 Phase 32a
KEY FEATURES
NX1 PDUs provide electric power for IT equipment in 19” enclosures.
They have been designed with specific features for Data Center applications.
Each C13 and C19 outlets are numbered and equipped with a cord locking (100
Newton retention force).
The circuits of the 32A PDUs are equipped with hydraulic magnetic circuit
protection. Hydraulic magnetic circuit breakers are not affected by ambient
temperature.
High ambient temperature rating: 55°C
Easy installation thanks to 330° rotating cable input and button-type brackets
INPUT
Input Plug | IEC 60309 32A 3P+N+E |
---|---|
Cord Length | 3m – 9.84 ft |
Cord Entry | Rotating (330°), bottom front |
Cable Type | HO7RNF 5G6 LSZH |
Maximum Input Current | 32A |
Nominal Input Voltage | 400V, 3-phases |
Rated Input Voltage | 346-415V |
Input Frequency | 50/60Hz |
Power Capacity | 22.2kW at 400V |
OUTPUT
Nominal Output Voltage | 230V |
---|---|
Outlet type | 24 C13 + 12 C19 |
Cord locking system | Yes |
Cord Retention | 100 N |
Circuit breakers | Yes |
Circuit breakers type | Mecanic Hydraulic (curve D) |
Cable locking system on C13/C19 sockets
- The cable is locked mechanically into the socket to prevent any unintended disconnection (caused by maintenance, vibrations, etc.). Pull-out force 100 N
- This universal solution is compatible with any standard compliant cord type on the market.
MECHANICAL FEATURES
-
Casings: 6060 T5-R19 natural anodised aluminium
-
Outlet modules:
PC/ABS
CW507L (CuZn 36) brass -
Fixing brackets:
DC01-A-m galvanised steel
Color | Aluminium grey (casing) / black (outlet modules) |
---|---|
Casing | Zero-U, aluminium |
IP | 20 |
IK | 04 |
ENVIRONMENTAL CHARACTERISTICS
Storage and transport tempe- rature | -20 to +70°C |
---|---|
Operating temperature | +5°C to +55°C |
Operating Relative Humidity | 5% to 95% |
Operating Elevation | 0 – 2000 m |
ELECTRICAL DIAGRAM
DIMENSIONS
MOUNTING SOLUTIONS
INCLUDED
Delivered with 2 different sets for mounting in a rack.
Set of 2 buttons
Screwless fixing. The height of the fixing centre can be set at any point
along the full height of the PDU by sliding the button slots into the groove
on the rear of the PDU. Tightened using a screwdriver.
Set of 2 standard fixing brackets
Screw-fixing (screws not included)
OPTION
Brackets for Nexpand racks
Screw-fixing (2 screws included)
- Ref. 981227 Set of 2 brackets (for 1 PDU)
- Ref. 981228 Set of 20 brackets (for 10 PDUs)
STANDARDS AND REGULATIONS
STANDARDS
Application | Standards |
---|---|
Safety | IEC 62368-1 |
C13 and C19 connectors for electrical equipment | IEC 60320-2-2 |
IEC 62368-1
Circuit breakers| IEC 60934
Industrial plugs| IEC 60309-1
Information and communication technology equipment| IEC 62368-1
Electromagnetic compatibility| EN 62311 (2008) EMF
EN 50491-5-2
EN 50491-5-3
EN 55035
EN 55032
EN 61000-4-11
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-3-2
REGULATORY APPROVALS
- CE, UKCA, CMIM
- RoHS directive (Restriction of Hazardous Substances).
- REACH regulations (Registration, Evaluation, Authorisation & restriction of CHemicals).