No. Description Function
1 Navigation Button Press OK to confirm. Non-Menu Mode: Press to turn on/off

the
LED light supplement. Press and adjust focus.
2| File Button| Press to enter albums.
3| Back Button| Exit the menu or return to the previous menu.
4 & 14| Function Button| Press to use the custom function.
5| Touch Screen| Show the live view interface. Touch-screen operation.
6| Focus Ring| Adjust the focus to find clear targets.
7| Light Sensor| Since the ambient brightness.
8| Microphone| Used to add voice notes.
9| Zoom Button| Press to zoom in, and press to zoom out.
10| Diopter Adjustment Wheel| Adjust the dioptric correction for the viewfinder.
11| Capture Button| Press: capture snapshots/stop recording. Hold: start
recording.
12| Focus Button| Press to start focus.
13| Laser Button| Press: measure the distance with a laser once. Hold: measure the
distance with the laser continuously.
15 & 16| Hand Strap Attachment Point| Mount the hand strap.
17| Neck Strap Attachment Point| Mount the neck strap.
18| Tripod Mount| Mount the tripod.
19| Viewfinder| View live view through the viewfinder.
20| Power Button| Press: standby mode/wake-up device. Hold power on/off.
21| Display Switch Button| Switch the view between the LCD display and the
Viewfinder.
22| Eyepiece Plug| Protect the eyepiece.
23| Loudspeaker| Play voice notes, voice alarm, and video voice.
24| Optical Lens| View the optical image.
25| Laser Distance Meter| Measure the distance with a laser.
26| Supplement Light| Increase ambient brightness in a dark environment.
27| Thermal Lens| Thermal imaging.
28| Memory Card Slot| Insert the memory card in it.
29| SIM Card Slot| Not Available.
30| Data Exchange Interface| Charge the device or export files with the supplied cable.
31| Micro HDMI Interface| Connect the device with an HDMI cable. A cable converter (HDMI
Type D to HDMI Type A) is included in the carrying case.
32| Battery Compartment| Install the battery in it.
33| Lens Release Button| Unlock the interchangeable lens.

Product Usage Instructions

  1. Turn off the device.
  2. Push the battery compartment lock leftwards to unlock the battery compartment, and then open the battery cover.
  3. Push the inner battery lock (in the black circle) leftwards to release the battery.
  4. Take the battery out of the battery compartment.
  5. If you want to install the battery back, push the battery into the battery compartment. The battery makes a click when it locks in place.

Appearance

The appearance of the handheld thermography camera may vary. Please take the actual product for reference.
Component & Interface (Page 1 – A)HIKMICRO-SP60-Handheld-Thermography-
Camera-FIG-21HIKMICRO-SP60-Handheld-
Thermography-Camera-FIG-22

No. Description Function



1

| ****



Navigation Button

| Menu Mode:

l  Press to select parameters.

l  Press OK to confirm.

Non-Menu Mode:

l  Press to turn on/off the LED light supplement.

l  Press to adjust focus.

2| File Button| Press to enter albums.
3| Back Button| Exit the menu or return to previous menu.
4 & 14| Function Button| Press to use the custom function.
5| Touch Screen| l  Show the live view interface.

l  Touch-screen operation.

6| Focus Ring| Adjust the focus to find clear targets.
7| Light Sensor| Since the ambient brightness.
8| Microphone| Used to add voice note.
9| Zoom Button| Press       to zoom in, and press        to zoom out.
10| Diopter Adjustment Wheel| Adjust the dioptric correction for the viewfinder.


11

| ****

Capture Button

| l  Press: capture snapshots/stop recording

l  Hold: start recording

12| Focus Button| Press to start focus.
No.| Description| Function
---|---|---


13

| ****

Laser Button

| l  Press: measure the distance with laser once

l  Hold: measure the distance with

laser continuously

15| Hand Strap Attachment Point| Mount the hand strap.
16 & 34| Neck Strap Attachment Point| Mount the neck strap.
17| Tripod Mount| Mount the tripod.
18| Viewfinder| View live view through the viewfinder. See Display Switch Button.


19

| ****

Power Button

|  Press: standby mode/wake up device

Hold: power on/off

20| Display Switch Button| Switch the view between the LCD display and the Viewfinder.
21| Eyepiece Plug| Protect the eyepiece.
22| Loudspeaker| Play voice notes, voice alarm, and video voice.
23| Optical Lens| View the optical image.
24| Laser Distance Meter| Measure the distance with a laser.
25| Supplement Light| Increase ambient brightness in a dark environment.
26| Thermal Lens| Thermal imaging
27| Memory Card Slot| Insert the memory card in it.
28| SIM Card Slot| Not Available.
29| Data Exchange Interface| Charge the device or export files with the supplied cable.



30

| ****


Indicator

| Indicate the charging status of the device.

l  Solid red: charging normally

l  Flashing red: charging exception

l  Solid green: fully charged

No. Description Function

31

| ****

Micro HDMI Interface

| Connect the device with an HDMI cable. A cable converter (HDMI Type D to HDMI Type A) is included in the carrying case.
32| Battery Compartment| Install the battery in it.
33| Lens Release Button| Unlock the interchangeable lens.

Remove the Battery (Page 3 – B)HIKMICRO-SP60-Handheld-Thermography-
Camera-FIG-23

Steps

  1. Turn off the device.
  2. Push the battery compartment lock leftwards to unlock the battery compartment, and then open the battery cover.
  3. Push the inner battery lock (in the black circle) leftwards to release the battery.
  4. Take the battery out of the battery compartment.
    Note : If you want to install the battery back, push the battery into the battery compartment. The battery makes a click when it locks in place.

Charge the Battery
After the device starts up, the OSD (on-screen display) shows the battery status. When the battery is low, charge the device and ensure it works properly.
For the first charge, charge the device for 2 hours.

Charge Device via Cable Interface (Page 4 – C – ①)HIKMICRO-SP60-Handheld-
Thermography-Camera-FIG-24

Steps

  1. Put the battery into the battery compartment of the device.
  2. Lift the cover of the cable interface.
  3. Plug in the cable, and connect the power supply to charge the battery. 3.2 Charge Device via Charging Base (Page 4 – C – ②)

Steps

  1. Put one or two batteries in the charging base.
  2. Connect the supplied charging base to the power supply. The indicator in the middle is green if it works properly.
  3. The left and right indicators show the charging status of the batteries.
    • Solid red: charging normally.
    • Solid green: fully charged.
  4. Draw the battery from the charging base, and disconnect the charging base from the power supply.

Change Interchangeable Lens (Optional) (Page 5 – D)

Steps

  1. Press the lens release button and turn the interchangeable lens anticlockwise until it stops.
  2. Remove the interchangeable lens carefully.
  3. Align the two white index marks on the device and the lens.
  4. Push the lens into position.
  5. Rotate the lens clockwise to fix it. The lens makes a click when it locks in place.

Notes:

  • Dust on the detector may cause blemishes in the image. If you can find the dust on the detector, use pressurized air from a compressed air canister to blow it off; but If you cannot find the dust, we recommend you contact your dealer or the nearest service center for cleaning.
  • If you purchase a new lens for the SP series, please contact the dealer or the nearest service center for the new lens calibration.

Tilt Lens and Screen (Page 6 – E)
You can tilt the lens and screen, as shown on page 6 – E.

Mount Hand Strap (Page 6 – F)

Steps:

  1. Thread the hand strap through the hand strap clutch.
  2. Thread one end of the hand strap through the two hand strap attachment points.
  3. Thread the hand strap through the hand strap buckle (as shown in the picture), and fasten the hand strap.
  4. Adjust the tightness of the hand strap as needed.

Connect Mobile and PC Client (Page 6 – G)
Scan the QR code to download and install HIKMICRO Viewer on your phone. You can view live view, capture snapshots, and record videos via the App on your phone. You can also analyze pictures offline, and generate and share a report via the App.
You can download HIKMICRO Analyzer (https://www.hikmicrotech.com) to analyze pictures and generate a custom format report on your PC.

HIKMICRO-SP60-Handheld-Thermography-Camera-FIG-26

More Operations
Scan the QR code to obtain the user manual for more detailed operations.

Legal Information
© 2022 Hangzhou Microimage Software Co., Ltd. All rights reserved.

About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images, and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual on the HIKMICRO website (www.hikmicrotech.com/).

Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks Acknowledgement and other HIKMICRO trademarks and logos are the properties of HIKMICRO in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.

The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. in the United States and other countries.

LEGAL DISCLAIMER
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE, AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKMICRO MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKMICRO BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF

DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.

YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKMICRO SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACKS, HACKER ATTACKS, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKMICRO WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.

YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. , YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, DATA PROTECTION, AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Regulatory Information
These clauses apply only to the products bearing the corresponding mark or information.

FCC

Please pay attention that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

CAUTION: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EU/UK Conformity Statement
This product and – if applicable – the supplied accessories are marked with “CE” and comply therefore with the applicable harmonized European standards listed under the Directive 2014/30/EU
(EMCD), Directive 2014/35/EU (LVD), Directive 2011/65/EU (RoHS).

This product and – if applicable – the supplied accessories are marked with “UKCA” and comply therefore with the following directives: Radio Equipment Regulations 2017, Electromagnetic Compatibility Regulations 2016, Electrical Equipment (Safety) Regulations 2016, the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012.

Restrictions in the 5 GHz band
According to Article 10 (10) of Directive 2014/53/EU, when operating in the 5150 to 5350 MHz frequency range, this device is restricted to indoor use in: Austria (AT), Belgium (BE), Bulgaria (BG), Croatia (HR), Cyprus (CY), the Czech Republic (CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR), Germany (DE), Greece (EL), Hungary (HU), Iceland (IS), Ireland (IE), Italy (IT), Latvia (LV), Liechtenstein (LI), Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Northern Ireland (UK(NI)), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia (SK), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), and Turkey (TR). In accordance with the Radio Equipment Regulations 2017 in the UK, the device working in the 5150 to 5350 MHz frequency range is restricted to indoor use in the United Kingdom.

Frequency Bands and Power (for CE/UKCA)
The frequency bands and modes and transmitting power (radiated and/or conducted) nominal limits applicable to the following radio equipment are as follows:

  • Wi-Fi: 2.4 GHz (2.4 GHz to 2.4835 GHz): 20 dBm; 5 GHz (5.15 GHz to 5.25 GHz): 23 dBm; 5 GHz (5.25 GHz to 5.35  GHz): 23 dBm; 5 GHz (5.47 GHz to 5.725GHz): 23 dBm; 5 GHz (5.725 GHz to 5.85 GHz): 14 dBm
  • Bluetooth: 2.4 GHz (2.4 GHz to 2.4835 GHz): 20 dBm
  • Use the power adapter provided by a qualified manufacturer. Refer to the product specification for detailed power requirements.
  • Use the battery provided by a qualified manufacturer. Refer to the product specification for detailed battery requirements.

Directive 2012/19/EU (WEEE Directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

According to the Waste Electrical and Electronic Equipment Regulations 2013: Products marked with this symbol cannot be disposed of as unsorted municipal waste in the United Kingdom. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info. According to the Batteries and Accumulators (Placing on the Market) Regulations 2008 and the Waste Batteries and Accumulators Regulations 2009: This product contains a battery that cannot be disposed of as unsorted municipal waste in the United Kingdom. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info.
Warning: Operation of this equipment in a residential environment could cause radio interference. Industry Canada ICES-003 Compliance
This device meets the CAN ICES-003 (A)/NMB-003(A) standards requirements.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator & your body.

This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

  1. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
  2. The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit; and
  3. The maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non point-to-point operation as appropriate.

Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.

Safety Instruction

These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss.

Laws and Regulations

  • Use of the product must be in strict compliance with the local electrical safety regulations.

Transportation

  • Keep the device in original or similar packaging while transporting it.
  • Keep all wrappers after unpacking them for future use. In case of any failure occurred you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage to the device and the company shall not take any responsibility.
  • Do not drop the product or subject it to physical shock. Keep the device away from magnetic interference.

Power Supply

  • The input voltage should meet the Limited Power Source (7.2 VDC, 890 mA) according to the IEC61010-1 standard. Please refer to the technical specifications for detailed information.
  • Make sure the plug is properly connected to the power socket.
  • DO NOT connect multiple devices to one power adapter, to avoid over-heating or fire hazards caused by overload.

Battery

  • The built-in battery cannot be dismantled. Please contact the manufacturer for repair if necessary.
  • DO NOT charge other battery types with the supplied charger. Confirm there is no flammable material within 2 m of the charger during charging.
  • For long-term storage of the battery, make sure it is fully charged every half year to ensure the battery quality. Otherwise, damage may occur.
  • DO NOT place the battery near the heating or fire source. Avoid direct sunlight.
  • DO NOT swallow the battery to avoid chemical burns.
  • DO NOT place the battery in the reach of children.
  • When the device is powered off and the RTC battery is full, the time settings can be kept for 3 months.
  • In the first use, power on the device and charge the RTC battery with the lithium battery for more than 2 hours.
  • The battery voltage is 7.2 V, and the battery capacity is 4800 mAh.
  • The battery is certified by UL2054.

Maintenance

  • If the product does not work properly, please contact your dealer or the nearest service center. We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.
  • A few device components (e.g., electrolytic capacitor) require regular replacement. The average lifespan varies, so periodic checking is recommended. Contact your dealer for details.
  • Wipe the device gently with a clean cloth and a small quantity of ethanol, if necessary.
  • Clean the lens with cotton wool and
  • If the equipment is used in a manner not specified by the manufacturer, the protection provided by the device may be impaired.
  • We recommend you send the device back for calibration once a year, and please contact the local dealer for information on maintenance points.
  • Please notice that the current limit of the USB 3.0 PowerShare port may vary with the PC brand, which is likely to result in incompatibility issues. Therefore it’s advised to use a regular USB 3.0 or USB 2.0 port if the USB device fails to be recognized by PC via USB 3.0 PowerShare port.
  • Your camera will periodically perform a self-calibration to optimize image quality and measurement accuracy. In this process, the image will pause briefly and you’ll hear a “click” as a shutter moves in front of the detector. The self-calibration will be more frequent during start-up or in very cold or hot environments. This is a normal part of operation to ensure optimum performance for your camera.

Using Environment

  • DO NOT expose the device to extremely hot, cold, dusty, corrosive, saline-alkali, or damp environments. Make sure the running environment meets the requirement of the device. The operating temperature shall be -20 °C to 50 °C (-4 °F to 122 °F), and the operating humidity shall be 95% or less.
  • Place the device in a dry and well-ventilated environment.
  • DO NOT expose the device to high electromagnetic radiation or dusty environments.
  • DO NOT aim the lens at the sun or any other bright light.
  • When any laser equipment is in use, make sure that the device lens is not exposed to the laser beam, or it may burn out.
  • The device is suitable for indoor and outdoor uses, but do not expose it in wet conditions.
  • The level of protection is IP 54.
  • The pollution degree is 2.

Technical Support

The https://www.hikmicrotech.com portal will help you as a HIKMICRO customer to get the most out of your HIKMICRO products. The portal gives you access to our support team, software and documentation, service contacts, etc.

Emergency
If smoke, odor, or noise arises from the device, immediately turn off the power, unplug the power cable, and contact the service center.

Laser
Warning:
The laser radiation emitted from the device can cause eye injuries, burning of skin, or inflammable substances. Prevent eyes from the direct laser. Before enabling the Light Supplement function, make sure no human or inflammable substances are in front of the laser lens. The wavelength is 650 nm, and the power is less than 1 Mw. The laser meets the IEC60825-1:2014 standard.

Laser maintenance: It is not necessary to maintain the laser regularly. If the laser does not work, the laser assembly needs to be replaced in the factory under warranty. Keep the device power off when replacing laser assembly. Caution-Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Manufacture Address

  • Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing
  • Subdistrict, Binjiang District, Hangzhou, Zhejiang 310052, China
  • Hangzhou Microimage Software Co., Ltd.

COMPLIANCE NOTICE: The thermal series products might be subject to export controls in various countries or regions, including without limitation, the United States, European Union, United Kingdom and/or other member countries of the Wassenaar Arrangement. Please consult your professional legal or compliance expert or local government authorities for any necessary export license requirements if you intend to transfer, export, or re-export the thermal series products between different countries.

QR SCAN

Contact Us

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals