INNO Instrument V12 Fiber Cleaver User Guide
- June 13, 2024
- iNNO INSTRUMENT
Table of Contents
- INNO Instrument V12 Fiber Cleaver
- Product Information
- Product Safety Warnings and Precautions
- OVERVIEW
- Operating procedure
- Safety warnings and precaution
- Product Overview
- Battery replacement
- Counter reset
- Maintenance
- Blade Replacement
- Fiber Collector Assembly
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INNO Instrument V12 Fiber Cleaver
Product Information
Single Fiber Holder
The Single Fiber Holder is a device used for holding and cleaving fiber
during fiber optic cable termination. It is designed to collect the scrap
automatically and ensure safe and efficient operation.
Product Overview
The Single Fiber Holder consists of a main body, an automatic fiber collector, and optional accessories such as blade height adjustment.
- Main Body: This is the main component of the Single Fiber Holder.
- Automatic Fiber Collector: This feature automatically collects the scrap after cleaving the fiber.
- Optional Accessories: The Single Fiber Holder may come with a blade height adjustment feature for precise cleaving and maintenance.
Product Safety Warnings and Precautions
Before using the Single Fiber Holder, please read and follow the safety warnings and precautions provided in the user manual to avoid injury or product damage.
- Do not disassemble or put oil on the main body to prevent damage to the product.
- Avoid dropping or causing percussion to the Single Fiber Holder as it may result in damage.
- Do not touch the blade with your fingers to avoid injury and damage to the blade.
- Fiber and scrap can be dangerous, so clean them up immediately and properly dispose of them in a designated bin.
- If you encounter any problems during use, stop operating and contact the INNO Service Center.
OVERVIEW
Operating procedure
- Place the fiber on the fiber holder.o
- Place the fiber on the proper groove and check the target length. In the case of 16mm cleaving, adjust the coating side of the 16mm marking location of the ruler shown as the left side picture.
- Cleave the fiber with one touch of the cover and then the scrap will be collected automatically
Cleaving and ReseT
Safety warnings and precaution
Thank you for choosing V12.
In order to use V12 properly, be well aware of this manual before use
Warnings, i f do not follow this manual, the user might get injured or damage on product
Precaution
- Disassembling or putting oil on the main body might cause damage to the product.
- Drop or percussion might damage the product.
- Do not touch the blade with anger to avoid injury and damage to the blade.
- Fiber and scrap are able to be dangerous, Clean up immediately.
- Properly place the fiber debris, and prepare a bin for fiber scrap.
- If there is any problem in use, stop operating and contact the INNO Service Center
Product Overview
- Cladding diameter 125μm
- Number of Core Single(Φ0.25 to 0.9mm and 2 to 3mm and drop cable) up to 16 Ribbons
- Cleaved length 5mm(≤250μm coating diameter) 10mm(>250μm coating diameter)
- Dimensions 106.5(W)X103.5(D)X55(H)
- Weight 325g
- Cleaver
- Operation Manual 1
- M2 Wrench **** 1
- Cleaver Case 1
- Brush 1
Optional Accessory
- Blade B80
- Fiber Holder CFH-40
Battery replacement
- Use the 1.5mm L-shaped wrench to unscrew the 4 screws on the bottom and remove the cove
- After taking out and replacing the battery marked in red, reinstall the cover and tighten the screws
Counter reset
- Insert the 1.5mm L-shaped wrench into ①, long press for 3S, the counter will be reset to zero
Blade height adjustment
- Disassemble the collector
- Unscrew the ② screw with a 1.5mm Hexagonal Wrench.
- Unscrew the ③ screw with the Slotted screwdriver
- Adjust the height with a Slotted screwdriver Screwing clockwise raise the height and screwing anti-clockwise drop the height.
Caution: When you adjust the height of the blade, use the soft-wooden Bar as a standard point to check blade height.
Maintenance
- To get stable quality cleaving, clean the cleaver after use.
- Clean ①-④ use a cotton swab with pure alcohol.
Blade Replacement
- Disassemble the collector
- Unscrew the ①-② screw with a 1.5mm Hexagonal Wrench.
- Unscrew the C blade bolts with a Slitted screwdriver.
- Hold the blade with tweezers.
- Take out the adjustment volts spring, and gear, and remove the blade as shown in the picture.
- Make sure the “1” position of the blade is on top.
After adjustment, reassemble as 5-4-3-2-1 procedure and operate a test. (Make sure to fasten the 3,2 position)
Blade rotation
Fiber Collector Assembly
- In order to reassemble the fiber collector, make 1 place both sides match each other.
- Screw the ①-② screw with a 1.5mm Hexagonal Wrench.
Cleaver Lock
Troubleshooting
The cleaving problem might occur for these reasons:
- Improperly place the fiber.
- Place fiber properly and straight.
- The height of the blade is too high.
- Adjust the height of the blade.
- Dust on holder or clamp.
- Clean holder and clamp.
- Dust on the fiber.
- Restripping and cleaning the fiber with alcohol.
If you have a problem in use, please contact INNO Local Distributors.
INNO INSTRUMENT, Inc.
- ADDRESS: E-22F,30, Songdomirae-ro, Yeonsu-gu, Incheon21990, Republic of Korea
- Tel: +82-32-837-5600
- Fax: +82-32-837-5601