INNO Instrument V30 Optical Multi Meter User Manual

June 12, 2024
iNNO INSTRUMENT

INNO Instrument V30 Optical Multi Meter

Product Information

The V30 Optical Multi Meter, produced by INNO, is a versatile device designed for optical fiber testing and network cable/phone line testing. It features an optical power meter (OPM), a visual fault locator (VFL), an LED lamp, and network cable/phone line testing capabilities.
The OPM utilizes an InGaAs detector and supports 2.5mm ST/SC/FC universal connectors. It can measure optical power in the wavelengths of 850/1300/1310/1490/1550/1625nm, with a measuring range from +6 to -70dBm. The OPM provides accurate measurements with linearity units displayed in uW or dBm.
The VFL emits a laser light for visual fault detection. It supports continuous laser mode or flicker laser mode with a 2Hz flicker frequency.
The LED lamp can be used in continuous light mode or flicker mode with SOS coding.
The device also includes network cable and phone line testing capabilities, supporting RJ45 and RJ11 interfaces. It can be used for UTP CAT-5/CAT-5e network cables and 2/4/6-core phone lines, with a maximum test distance of 1KM.
The V30 Optical Multi Meter has power-on and power saving functions. It automatically shuts down after 10 minutes of inactivity, but this feature can be disabled by pressing and holding the MODE button during power-on. The device defaults to the OPM function upon power-on, but can switch between OPM, VFL, LED, and network cable/phone line tester functions in loop mode.

Product Usage Instructions

  1. Power On and Off: Quickly press the MODE button to turn on the instrument. Press and hold the MODE button for 2 seconds or more to turn off the instrument. The instrument will shut down automatically after 10 minutes of inactivity.
  2. Function Selection: The instrument defaults to the OPM function upon power-on. Press the MODE button to cycle through the OPM, VFL, LED, and network cable/phone line tester functions.
  3. Optical Power Meter (OPM): To switch the measuring optical wavelengths, press the T button under the OPM function. The instrument supports calibrating wavelengths of 850/1300/1310/1490/1550/1625nm. The numeric display can be switched between uW and dBm by pressing the U button.
  4. LED Lamp: Under the LED function, press the U button to select continuous light mode or flicker mode with SOS coding.
  5. Visual Fault Locator (VFL): Under the VFL function, press the U button to select continuous laser mode or flicker laser mode with a 2Hz flicker frequency.

For detailed instructions on other functions and features, refer to the user manual provided with the V30 Optical Multi Meter.
Thank you for choosing V30 Optical Multi Meter produced by INNO!
This manual is only subject to the users who have already purchased V30 Optical Multi Meters. Copying any part of this manual without any written permission by publisher is forbidden.

Overview

  1. Optical fiber connector
    ( standard FC )

  2. LED lamp

  3. VFL interface (2.5mm UPP)

  4. LCD

  5. Button for wavelength selection (available under“ OPM ” function)

    • Size:124×53×33 (L×W×H)
    • Weight:155g
  6. Flicker on/off (available under the functions of “ VFL ” or “ LED ” )

  7. Power on/off or function selection button

  8. Test indicator for network cable connection system

  9. Mini USB charger socket

  10. RJ45 network test socket

  11. RJ11 phone line test socket

Parameters

Parameters

Optical Power Meter(OPM)| Type of detector| InGaAs
Type of optical fiber interface| 2.5mm of ST/SC/FC universal connectors
Calibrated wavelengths| 850/1300/1310/1490/1550/1625nm
Measuring range| from +6 to -70dBm
Accuracy| ± 0.02dB
Linearity| ± 2%
Units| dBm、mW 、uW
Visual Fault Locator (VFL/ VLS)| Output power| 1mW
Type of optical fiber interface| 5KM of single mode fiber(SMF)
Radiation safety class| Class 2
Wavelengths| 650nm ± 20nm
Output modes| Continuous /2Hz flicker lasers
Battery reverse protection function| Available
Network cable /phone line test| Type of interface| RJ45/RJ11
Applicable network / phone lines| UTP CAT-5/CAT-5e (2/4/6-core phone lines)
Max.test distance| 1KM
Operating temperature| from -10℃ to +60℃
Storage temperature| from -20℃ to +70℃
Relative humidity| <90% (non-condensing)

Functions

Power-on and power saving function:
Power-on:
Quickly press “MODE” key to turn on the instrument.
Power-off:
Press and hold “MODE” key for 2 seconds or more until “OFF” displays on the screen.
INNO Instrument V30 Optical Multi Meter 2 Power saving function:
This instrument will shut off automatically after waiting but without receiving any operation instruction for about 10 minutes. If you want to disable this auto shut-off function and keep this instrument working, please press and hold the “MODE” button immediately when power on for about 2 seconds until “PERM” appears on the bottom right screen of the LCD, meaning that the power saving function has been canceled.
Function selections:
It defaults to be under “OPM” function when power-on. 4 functions including “OPM”, “VFL”, “LED” and “network cable/phone line tester” will be switched in loop mode.
Optical Power Meter (OPM)
You can switch the measuring optical wavelengths by pressing “T” button under the function of “OPM”.The calibrating wavelen- gths of this instrument are 850 /1300/1310/1490/1550/1625nm and the units of numeric display include uW and dBm,which can be switched via “U” button.
Visual Fault Locator (VFL)
You can select continuous laser mode or flicker laser mode with 2Hz of flicker frequency under the function of “VFL”.
LED lamp
You can select continuous light mode of LED or flickermode of SOS coding by pressing “U” button under the function of LED.
Null Function Description
Tighten the OPM dust cap. “NULL”appears when “T” button and “U” button are pressed at the same time in OPM model.
Network cable/phone line test
INNO Instrument V30 Optical Multi Meter 7
The “Network cable/ phone line test”(NET) function is used in network generic wiring and for verifying the link on-off condition of network including the sequence of testing cable connection systems. Test will begin when this NET function is enabled; the 8 indicators are used for indicating the sequence of testing cable connection systems. When the network cable or phone line is connected to this instrument and remote model, 8 indicators will blink in turn.
Any calibration, maintenance or repair to this instrument should be carried out by qualified maintenance staff.
Please contact with INNO customer engineer or access to the following website for consultation:
www.innoinstrument.com
Tel: +82 32 837 5600
Fax: +82 32 837 5601
Email: [email protected]
Company:INNO Instrument Inc.
Address:E-22F, 30, Songdomirae-ro, Yeonsu-gu,
Incheon21990, Republic of Korea

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

iNNO INSTRUMENT User Manuals

Related Manuals