INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer User Guide

June 12, 2024
iNNO INSTRUMENT

5G SMART TM / 5G PRO TM
Handheld Spectrum Analyzer
USER GUIDE
5G SMART TM : 9 kHz to 15 GHz
5G PRO TM : 9 kHz to 43 GHz

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer INNO INSTRUMENT INC.

SAFETY INSTRUCTION FOR RECHARGEABLE LITHIUM-ION BATTERY

Risk of injury and instrument damage
The instrument must be used in an appropriate manner to prevent electric shock, fire, personal injury, or instrument damage.

  • Do not open the instrument casing.
  • Read and observe the ” Safety Instructions” provided with the instrument.
  • Read and observe the safety instructions in the following sections.

Risk of serious personal injury or even death
You must fully observe the following instructions in order to avoid serious personal injury ‒ or even death ‒ due to an explosion and/or fire.

  1. Do not dismantle, open, or crush the batteries or drop them from a great height. If mechanical damage occurs, there is a risk that chemicals may be released. Gases that are released can cause breathing difficulties. Immediately ventilate the area and in serious cases consult a doctor.
  2. Irritation can occur if the chemicals that are released come in contact with the skin or eyes. If this happens, immediately and thoroughly rinse the skin or eyes with water and consult a doctor.
  3. Do not expose cells or batteries to heat or fire. Do not store them in direct sunlight. If overheating occurs, there is the risk of an explosion or a fire, which can lead to serious personal injuries.
  4.  Keep the batteries clean and dry. If the terminals become soiled, clean them with a dry, clean cloth.
  5.  Charge the batteries prior to using them. Only use the appropriate INNO Instrument charger provided with the instrument to charge the batteries. If the batteries are improperly charged, there is a risk of explosion, which can cause serious personal injury.
  6.  Only charge batteries until they are fully charged. Frequent overcharging can reduce the battery lifetime.
  7. Remove the battery from the device when the battery is not being used. Following a longer period of storage, it may be necessary to charge and discharge the battery several times in order to obtain the full capacity.
  8. Do not dispose of the batteries with unsorted municipal waste. The batteries must be collected separately. After the end of their life, dispose of the batteries at a suitable collection point.
  9. Keep this safety information for future reference

Warranty
This INNO Instrument’s product is warranted against defects in material and workmanship for a period of three years from the date of shipment. During the warranty period, INNO Instrument will, at its option, either repair or replace products that prove to be defective.
For warranty service or repair, this product must be returned to a service facility designated by INNO Instrument. For more information, see “INNO Warranty Terms and Conditions.”

GETTING STARTED

Electromagnetic interference (EMI) may affect the measurement results. To suppress generated electromagnetic interference (EMI):  Use suitable shielded cables of high quality. For example, use double-shielded RF and LAN cables.

  •  Always terminate open cable ends.
  •  Note the EMC classification in the data sheet.

UUNPACKING AND CHECKING INSTRUMENT
Unpack the instrument carefully and check the contents of the package.

  •  Check the equipment for completeness using the delivery note and the accessory lists for the various items.
  • Check the instrument for any damage. If there is damage, immediately contact the regional sales office or carrier who delivered the instrument.
  • Keep the box and packing material.

ACCESSORY LIST

The instrument comes with the following accessories:

  • Power supply cable and adapter set
  • Li-ion rechargeable battery
  • USB2.0 cable
  • Side strap (installed)
  • Shoulder strap
  • Optional accessories and their order numbers are listed in the data sheet.

BATTERY INSTALLATION
Spectrum Analyzer is designed for service and maintenance applications on- site. Depending on thenvironment, you can adjust the viewing angle of the display and either lay it out horizontally or prup using the support on the back of the Spectrum Analyzer.

  1. Slide battery cover to open position located on the battery compartment.
  2.  Open the cover.
  3.  Insert the provided battery into the Spectrum Analyzer.
  4. Close the cover and slide cover to close position.

USING AC ADAPTER

**** Risk of instrument damage. To avoid instrument damage,

  • Only use the power supply (INNO Instrument, ADP-65JH BBFC) included in the package.
  • Make sure that the AC supply voltage is compatible to the voltage specified on the power supply unit.
  • Attach the appropriate adapter to the power supply.

1. Connect the AC adapter to the DC port on the top side of the instrument.
2. Make sure to fully insert the AC adapter plug into the DC port.
3. Depending on the system you need, rigidly connect the appropriate power cable
included in the package to the AC adapter.
4. Connect the power cable plug to an AC power outlet.

The voltage range of the AC power supply is 100 V to 240 V AC. After the instrument is connected to the power supply, you can turn it on with the Power Button on the front panel.

BATTERY OPERATION
Spectrum analyzer has a battery indicator which displays the battery charging status on the bottom of the battery icon. The lithium-ion battery has a capacity of 7,800 mAh and it allows operation of more than 3 hours when it is fully charged.
The actual operation time depends on the current charged status, the ambient temperature, and the operating mode of the spectrum analyzer. The battery charging and discharging process of the battery icon indicated in the display screen is illustrated below:INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - Charging

**** Battery provided in the package is not fully charged, for battery operation you have to charge it firTo charge the battery, connect the charger to AC power adapter included in the package.

INSTRUMENT OVERVIEW

5G PRO (9 kHz ~ 43 GHz)

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
INSTRUMENT RF power overload
Spectrum analyzer maybe loaded with up to +27 dBm for up to three minutes. If you apply higher than this for a longer period, the spectrum analyzer may be damaged.
Risk of electric shock
To avoid electrical shock the DC input voltage, you must never exceed the value specified on the instrument.
Risk of damage
To avoid damage to the coupling capacitor, input attenuator or the mixer, the DC input voltage must never exceed the value specified in the data sheet.
TOUCHSCREEN DISPLAY
All measurement results are displayed on the screen. Additionally, the screen display provides status and setting information and you can change the parameters setting with touchscreen gesture
**** Risk of touchscreen damage during operation
The touchscreen may be damaged by inappropriate tools or excessive force. Observe the following instructions when operating or cleaning the touchscreen:

  •  Do not touch the screen with ball point pens or other pointed objects with sharp edges.
  •  It is recommended that you operate the touchscreen by finger only. As an alternative, you may use a stylus pen with a smooth soft tip.
  • Do not apply excessive force to the screen. Touch it gently.
  • Do not scratch the screen surface, e.g. with a fingernail. Do not rub it strongly, for example with a dust cloth.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
scratchINNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - shortcut

MEASUREMENT INFORMATION WINDOW
It shows the measurement settings. It also supports shortcut to settings windows as well as measurement information (Tab the information box to go to the setting window).
The measurement information window can be hidden and expanded via the Hide / Expand buttons.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
WINDOW

Touchscreen gesture

  •  Swipe horizontally to move markers and gate setting bars in the trace window, the gesture is used to change the marker frequency and gate delay & length.
  • Tab on the trace window to select a key or item.
  • Touch screen does not support multi-touch gestures with two fingers operation.

HOME SCREEN
All measurement available in the Spectrum Analyzer are displayed on the screen. Tab to select and rumeasurement.INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - HOME SCREEN

SHORTCUTS
Quickly access using the shortcuts.INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - shortcuat

CHANGING MODE
There are two ways to select or change measurement mode.
Press Home ( ) and select measurement modeINNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - change
Or,
Using “Mode bar” located on top of the display:

  • Tab the mode icon such as “Spectrum”, “Realtime Spectrum Analyzer”.
  • You can change the mode by Tab Add ( ) icon.
  • Maximum 4-Mode can be activated, and supported mode may vary depending on the option.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - depending 1
  • Turn off and remove mode by pressing the X button on the activated mode tab (when turn off the mode, mode changing will be followed in a few seconds.
  • Supported mode:
    − Spectrum Analyzer
    − Realtime Spectrum Analyzer
    − LTE FDD Analyzer
    − LTE TDD Analyzer
    − 5GR Analyzer

ON-SCREEN KEYBOARD
On-screen keyboard is an additional means of interacting with the instrument. It provides convenience of usage with the touchscreen input. Accessing the on-screen keyboard is only available for text-based entry, e.g. save or open a filename.INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - keyboard KEYPAD
The keypad is used to enter alphanumeric parameters, including the corresponding units. It contains the following keys:

Key Description
Alphanumeric keys Enter numbers and (special) characters in edit dialog

boxes.
Decimal point| Inserts a decimal point “.” at the cursor position.
Sign key| Changes the sign of a numeric parameter. In the case of an alphanumeric parameter, inserts a “-” at the cursor position.
Unit keys (GHz/MHz/kHz/Hz, dBm/dB, s/ms/us/ns)| These keys add the selected unit to the entered numeric value and complete the
entry. In the case of level entries (e.g. in dB) or dimensionless values, all units have the value “1” as multiplying factor. Thus, they also act like an enter key function.
Clear key| Clear the values entered.
Back key| If an alphanumeric entry has already been started, this key deletes the character to the left of the cursor.
Navigation keys| A cursor key to increase or decrease value or move right or left.

**** Confirmed the value

  • All the values will be confirmed by selecting the unit.

FUNCTION KEYS
Function keys provide access to the most common measurement settings and functions in the instrument.INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - KEYS

A detailed description of the corresponding function is:

Function Key Description
Frequency Sets the center frequency, frequency step size, frequency offset as

well as the start and stop frequencies for the frequency range under consideration.
Amplitude| Sets the reference level, the displayed dynamic range, the RF attenuation, and the unit for the level display.
Sets the level offset and activates the preamplifier
Sweep| Sets the sweep time.
Selects continuous measurement or single measurement.
Bandwidth| Sets the resolution bandwidth and the video bandwidth.
Trigger| Sets the trigger mode, trigger threshold and the trigger delay of the external trigger signal.
Trace| Configures the measured data acquisition and the analysis of the measurement data.
Marker| Sets and positions the absolute and relative measurement markers (markers and delta markers). Marker positioning using peak, next peak.
Provide the following marker functions:
– Marker function which provides capability to measure noise and
measure frequency using frequency counter.
Limit| Sets the limit and multiple limits on the trace-based.
Measure| This key shows available measurements in the selected mode, and functionality to select and configure measurement, for example, in spectrum analyzer mode:
– Swept Spectrum
– Channel Power
– Occupied bandwidth (OBW)
– Spectrum emission mask (Spectrum Emission Mask)
– Multicarrier adjacent channel power (ACP)
Measure Setup| This key provides detailed setup menu available in the selected measurements.
All Settings| This key provides all settings window.

** Available items in function key may be different per different mode.
STATUS BAR**
The “Status bar” is located on bottom of the display (always display). It provides the basic information of the instrument such as Logo, GPS status, Reference selection, Messages, Date and Time and Battery charging and discharging status.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
STATUS BAR

MEASUREMENT RESULT WINDOW
The “Measurement Result window” is the main user interface window in spectrum analyzer. It displays the measurement traces where markers and limit lines are also displayed.

  •  Shows the results by measurement item in the selected mode.
  • Realtime Spectrum Analyzer measurement results support dual-display:
    − Realtime Spectrogram (Top Spectrum + Bottom Spectrogram)
    − Persistent Spectrogram (top Spectrogram + bottom Persistent Spectrum)

**** In dual-display mode, the measurement highlighted in the yellow box indicates the active window, and all settings are displayed relative to the active window.

INSTRUMENT SETTINGS
CONFIGURING EXTERNAL REFERENCE
You can apply a 10 MHz, 13 MHz, 15 MHz, and GPS external reference signal to it for frequency synchronization. The selected external reference label is displayed at the status bar to indicate that the reference signal is supplied via external signal input. Refer to the data sheet for the detailed reference signal conditions.

USING GPS RECEIVER
Spectrum analyzer can locate exact position by providing the GPS antenna to the GPS connector. The “Instrument Setup” provides all settings necessary to configure the GPS.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
RECEIVER 1 CONFIGURING POWER ON SETTING
You can configure the instrument power on settings:

  • Factory Default : Booting with the factory default settings.
  • Last: Booting with the last settings.
  • User: Booting with the user configured settings.
  • Save User Preset: Save the current status settings to a user preset.

CONFIGURING DISPLAY
You can configure the display mode, LCD brightness, and key beep sound.INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - HOME
DISPLAY

  • Indoor display provides normal color mode.
  • Outdoor display changes the color setting to high contrast black and white display mode enhances screen readability under the direct sun-light.
  • Night display provides screen readability under the dark environment minimize dazzling.

CONFIGURING DATE AND TIME
Spectrum analyzer has an internal clock that can apply a date and timestamp. In the “Setup” dialog box, you can set both date and time. And you can also set the data formats.INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - HOME DATE CONFIGURING NETWORK
Spectrum analyzer provides Remote Interface to control the instrument remotely.
FILE MANAGER
Spectrum analyzer can store measurement results and settings in the internal memory, removable micro-SD card or on a USB flash drive via the USB interface.
** Storage device
The spectrum analyzer has built-in micro-SD card. Both USB flash drive and micro-SD card can be connected to the instrument, you can select the media to be used.
If both storage devices are not connected, the internal memory of the instrument is used for storage (default storage is internal).INNO Instrument
5G SMARTTM Handheld Spectrum Analyzer - HOME connected,
UPDATING FIRMWARE**
Instrument’s Firmware can be upgraded from storage media such as a USB memory stick. Here is the procedure how to update the firmware:

  1. Copy instrument’s firmware file (*.rc) into a USB flash drive.
  2.  Connect the USB flash drive with the latest firmware into the USB port on the instrument.
  3. Select the Settings ( ) icon. 4. Select Upgrade.
  4.  A dialog box appears displaying the update progress in % and instructing you to complete the firmware update by restarting the instrument.
  5.  Restart the instrument to complete the updates.

INSTRUMENT FUNCTIONS
This section provides information about the basic functionality and the user interface.
CHANGING CENTER FREQUENCY AND SPAN
Tab Frequency key ( ) or Frequency Information box to adjust the center frequency and Span (X-scale) of the spectrum measurement.INNO Instrument 5G
SMARTTM Handheld Spectrum Analyzer - HOME frequency
CHANGE REFERENCE LEVEL
Tab Amplitude key ( ) or press Amplitude Information box to adjust the amplitude (Y-scale) of the spectrum measurement.INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - HOME amplitude CHANGING SWEEP MODE
Tab Sweep key ( ) or press Sweep Information box to adjust the sweep mode of the spectrum measurement.INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - sweep mode
CHANGING BANDWIDTH
Tab Bandwidth key ( ) or press Bandwidth Information box to adjust the RBW, VBW of the spectrum measurement.INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - CHANGING BANDWIDTH SET UP TRIGGERING
Tab trace key ( ) or press Trigger Information box to set up triggering. Trigger menu does not appear in normal operation mode. It can be controlled in zero span.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - rigger
menThe spectrum analyzer provides the following Trigger modes.

  • Free Run:
    A sweep is automatically updated internally. After the last sweep, the next sweep is performed.

  • External:
    A sweep is triggered by an external TTL signal applied to the ‘Trig In’ port.

  • Video:
    A sweep begins when the input signal passes the trigger level. Video trigger is useful for analyzintransient signal.

  • Periodic timer :
    A sweep runs periodically according to the Trigger Peri Time.

  • RF Burst:
    A sweep begins when the signal in the IF stage crosses the Trigger Level.

ADDING TRACE
Tab Trace key ( ) or press Trace Information box to add traces of the spectrum measurement.
How to activate trace(s):

  1.  Select Trace (from T1 to T6).
  2. Select Trace Property (Clear Write, Max Hold, Min Hold, View (Capture), Average).
  3. Turn Trace On.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
PropertyINNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - provides

The spectrum analyzer provides the following trace modes.

  • Clear/Write:
    In its default state, the spectrum analyzer overwrites the trace after each sweep. You can apply all detectors in this mode.

  • Average:
    The trace is the result of the moving average over several sweeps. The spectrum analyzer calculates the (moving) average of the power levels for each pixel over a particular number of sweeps in the range from 1 to 10,000. Averaging reduces the effects of noise but has no effects on sine signals. Using the trace averaging therefore is an effective way to detect signals in the vicinity of noise.

  • Max Hold:
    The trace shows the maximum power levels that have been measured at each pixel. To overwrite a max hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the max hold trace mode is an effective way to detect intermittent signals or the maximum values of fluctuating signals, for example.

  • Min Hold:
    The trace shows the minimum power levels that have been measured at each pixel. To overwrite a min hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the min hold trace mode is an effective way to highlight signals within noise or suppress intermittent signals.

  • View:
    The view trace mode freezes the current trace and aborts the measurement. Using the view trace mode is an effective way to evaluate the trace, for example with markers.

ADDING MARKER

Tab Marker key ( ) or tab Marker Shortcut – Peak Search ( ) to set markers on the spectrum measurement. The marker is placed on the trace move marker position using finger (click and drag). When Marker is enabled, Marker Table will be displayed on the bottom of the measure result with the corresponding frequency and amplitude information.INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - bottom The spectrum analyzer supports 6 markers, five of which can be used as either markers or delta markers.

  • Delta:
    Delta marker level is always a relative to the main marker level and so the delta marker level unit is always dB. The delta marker frequency is always relative to the main marker. The delta marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta marker.

  • Delta pair:
    Delta pair marker level is always a relative to the main marker level but it also changes by the signal level. The delta pair marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta pair marker.
    **** Deactivating marker(s)
    If you delete marker 1 (M1), all delta markers that are relative to that marker are also deleted.

Peak Search:

  1.  Tab Marker Shortcut – Peak Search ( )
  2.  Select Marker Property or
  3. Set Marker to Center / Start / Stop

Always peak can be set using Peak Track On.

MOVING MARKER

Tab and drag on the marker bar or icon to change the marker position in the trace window.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - MOVING
MARKER

MARKER FUNCTION
In addition to the frequency and level readout, the spectrum analyzer provides two additional marker functions in spectrum analyzer mode.

  • Noise Marker:
    The marker noise function calculates the noise power density at the marker position in dBm/Hz. This involves with the several variables in the calculation of the noise power density, including the trace pixel values, the resolution bandwidth, the detector, and the level display mode (absolute or relative).

  • Frequency Count:
    The frequency counter accurately measures the frequency at the marker position. When calculating the horizontal position of the marker, the spectrum analyzer includes the current span, center frequency and the frequency of the pixel the marker is on. As the trace only has 801 pixels, the marker position is just an approximation, especially if the span is very wide.
    With the frequency counter, however, you can get a more accurate result of the horizontal marker position.

CONFIGURING MEASUREMENT

Measure Setup key ( ) provides all available configurations (required settings) of the current selected measurements. Configurable items may differ from the different measurements. Configurable items that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide.
Measure key ( ) provides all available measurements (supported measurement) of the current selected mode. Available measurements may differ from the different modes. Available measurements that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide.

SPECTRUM ANALYZER MODE

The default operating mode of the spectrum analyzer is the spectrum analyzer. The spectrum analyzer provides the functionality to perform measurements in the frequency domain, e.g. to identify the power and frequency of signals.
Gated Sweep option available under Sweep ( ) function key provides time-domain measurement of a particular frequency over time. The span during time domain measurements (Gated Sweep mode) is zero (zero span). You can use Gated Sweep measurements to monitor the characteristics of a time-varying signal.
To perform a time domain measurement, you have to set the span to zero or go to Gated Sweep mode manually by setting Gated Delay and Gate Length per signal to be captured. When the Gated Sweep is On, the horizontal axis is time, and the vertical axis shows the signal levels (refer to Gated Sweep Mode for the detail).
SCREEN LAYOUT AND ELEMENTS
The following illustrates the screen layout in spectrum analyzer mode. It shows all elements that are the same for all operating modes of the spectrum analyzer. Screen layouts that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide.INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer -
ELEMENTS

SETTING FREQUENCY AND SPAN
The center frequency represents the frequency at the center of the horizontal axis in the measurement result window.
The span is the frequency range around the center frequency that a spectrum analyzer displays on the measurement result screen.

  1. Tab the Frequency key.
  2. Select the “Center Freq” softkey.
  3.  Enter the center frequency in an open field. The frequency you have entered becomes the new center frequency.
  4. Select the “Span” softkey.
  5. Enter the span frequency in an open field. The span you have entered becomes the new span frequency.

SETTING START AND STOP FREQUENCY
Defining a start and a stop frequency is best suited for example, for measurements on harmonics or signals whose exact frequency is unknown.

  1. Tab the Frequency key .
  2. Select the “Start Freq” softkey.
  3. Enter the start frequency in an open field.
  4. Set a stop frequency with the “Stop Freq” softkey.
  5. Enter the stop frequency in an open field. The stop frequency you have entered becomes the new stop frequency.

** If you have entered a stop frequency that is outside the maximum frequency range of the instrument, then the spectrum analyzer sets the stop frequency to the possible maximum.
Zero Span mode
You can also activate time domain measurements by selecting Zero Span. When measuring in the zero-span mode (time domain), the span is 0 Hz. In that state, the spectrum analyzer measures the signal at the current center frequency only. Instead of displaying the spectrum, the spectrum analyzer shows the signal power over a certain time period. The horizontal axis becomes the time axis. The display always starts at 0 s and stops after the currently set sweep time.
SETTING REFERENCE LEVEL
** The reference level is represented graphically by the grid line at the top of the measurement result window. The reference level sets the input signal gain up to the display stage. If the reference level is low, the gain is high. That means that even weak signals are displayed clearly.
If you are measuring strong signals, you have to set a high reference level to prevent an overload of the signal path of the analyzer and to keep the signal within the display range. If you are measuring the spectrum of a composite signal, make sure that the  eference level is high enough to cover all signals and that all signals are within the amplitude range of measurement result window.

  1. Tab the Amplitude key.
  2. Select the “Ref Level” softkey.
  3.  Enter the reference level in an open field.
  4. If you change the reference level, the spectrum analyzer adjusts the position of the trace as you make the changes.

SETTING ATTENUATION
RF attenuation adjusts the input range inside the analyzer. It is coupled directly to the reference level. If you have set a high reference level, RF attenuation is turned on so that the input mixer always remains in the linear range.

  1. Tab the Amplitude key.
  2. Select the “Attenuation” softkey.
  3.  Enter the attenuation level in an open field (0 to 48 dB in 4 dB step).
  4. If you change the attenuation, the spectrum analyzer adjusts the position of the trace as you make the changes.

USING PREAMPLIFIER
To increase the input sensitivity, you can turn on internal pre-amplifier provides an ~20 dB gain. In the default state of the spectrum analyzer, the preamplifier is turned off. If you want to measure signals with low powers, you can turn it on.

  1. Tab the Amplitude key.
  2.  Turn On and Off the “Preamp”.

SETTING RESOLUTION BANDWIDTHS
The resolution bandwidth in a spectrum analyzer determines the frequency resolution for frequency domain measurements and therefore determines how well it can separate adjacent frequencies. The measurement result observed depends on the passband of a resolution filter.
In the default state, the resolution bandwidth is coupled to the span, i.e. if you change the span, the spectrum analyzer adjusts the resolution bandwidth.

  1. Tab the Bandwidth key. By default, the resolution bandwidth is coupled to the span.
  2. Select the “Manual RBW” softkey.
  3. Enter the resolution bandwidth in an open field. The spectrum analyzer uses the resolution bandwidth you have entered for the measurement.
  4. Select the “Auto RBW” softkey to again couple the resolution bandwidth to the span.

The spectrum analyzer has resolution bandwidths from 1 Hz to 5 MHz in a 1-3-10 sequence.

** Automatic adjustment of the sweep time
In its default mode, the spectrum analyzer automatically adjusts the sweep time as soon as you change the resolution bandwidth. This adjustment makes sure that the settling time required for the selected resolution filter is carefully considered.
SETTING VIDEO BANDWIDTH
** The video bandwidth (VBW) basically smoothes the trace by reducing the noise and therefore making power levels easier to see. The noise reduction is a result of the video filter. This lowpass filter defines the video bandwidth and filters the higher frequency parts of the voltage from the signal.
Like the resolution bandwidth, the video bandwidth has an effect on sweep speed. Before each measurement, the video filter has to settle.

  1.  Tab the Bandwidth key. By default, the resolution bandwidth is coupled to the span.
  2.  Select the “Manual VBW” softkey.
  3. Enter the video bandwidth in an open field. The spectrum analyzer uses the video bandwidth you have entered for the measurement.
  4. Select the “Auto VBW” softkey again to couple the video bandwidth to the RBW.

The spectrum analyzer has video bandwidths from 1 Hz to 5 MHz in a 1-3-10 sequence.
SETTING DETECTOR
The number of measurement results collected in a single sweep usually is extremely high, especially if the span is large. However, the display of the spectrum analyzer can display only 801 results in horizontal direction, as it is limited by the number of pixels that are available on the display. Therefore, it has to combine measurement results to fit them on the display. In that case, one pixel represents a frequency range = span /801.
The detector determines the way the spectrum analyzer combines and displays the results for one pixel. The data base is the video voltage of the analyzer.

  1. Tab the Trace key.
  2. Select the “Detector” softkey.
  3. Select the detector from the submenu. If the “Auto Detector” selection is active, the selection of the trace detector is always “Normal.”

The spectrum analyzer provides several types of detectors.

  • Positive Peak:
    If the positive peak detector is active, the spectrum analyzer displays both the maximum power levels that were measured in the frequency range covered by a pixel.

  • Negative Peak:
    The min peak detector displays sine signals with the correct level and suppresses noise. Therefore it is useful to find sine signals in the vicinity of noise.

  • Sample:
    If the sample detector is active, the spectrum analyzer shows one random power level that was measured in the frequency range covered by a pixel. The sample detector is useful for measurements in the time domain (span = 0 Hz) as it provides the only way to represent the timing of the video signal correctly.
    In the frequency domain, the sample detector is an effective way to measure noise power because noise usually has a uniform spectrum with a normal amplitude distribution. Signals may get lost if you are using the sample detector for measurements with a span that is greater than “RBW x 801”.

  • RMS:
    If the RMS detector is active, the spectrum analyzer measures the spectral power over one pixel. The RMS detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the RMS detector in combination with a high sweep time.

GATED SWEEP MODE

Tab Sweep key ( ) and select the Gated Sweep ( ) to configure Gated Sweep mode. Gated sweep allows you to synchronize the measurement sweep with an event so that the analyzer collects data at the appropriate time. This is useful for measuring signals in the time domain such as pulsed RF, time multiplexed, or burst modulated signals.
**  Gated Sweep
Gated Sweep mode is only available on instrument with Gated Sweep option installed.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - CHANGING
f
CONFIGURING MEASUREMENT**

Measure key ( ) provides all available measurements (supported measurement) of the spectrum analyzer mode.

MEASURING CHANNEL POWER
The channel power measurement selectively measures the power of modulated signals. Unlike a power meter that performs measurements over its entire frequency range, the channel power measurement measures the power of a specific transmission channel. Other signals in the frequency spectrum do not show in the results. It determines the total power of the channel by integrating the results on the trace.
The following parameters need to be configured to perform channel power measurement using Measure Setup key ( ):

  • Channel Bandwidth to be measured.

MEASURING OCCUPIED BANDWIDTH
The occupied bandwidth is defined as the bandwidth that contains a specified percentage of the entire power of the transmitter. Numerous standards require an occupied bandwidth of 99 which is also the default setting. If you need another percentage for the occupied bandwidth, you can set values from 10 % to 99.9 %.
The following parameters need to be configured to perform channel power measurement using Measure Setup key ( ):

  •  Channel Bandwidth to be measured.
  •  Occupied Bandwidth in %.
    INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
channel

MEASURING SPECTRUM EMISSION MASK (SEM)
The Spectrum Emission Mask (SEM) measurement is a method to detect spurious emissions or intermodulation products of a signal. When performing a SEM measurement, the spectrum analyzer checks the signal against a spectral mask to see whether the signal complies with a specific standard or not. Therefore, the spectrum analyzer provides predefined spectrum emission masks for various telecommunications standards.
Spectrum Emission Mask is changed in the Measure Setup menu. ( )
A ‘Selection mask’ includes ‘Cat A,>3GHz’, ‘Cat B,>3GHz’, ‘31<P<38dBm,>3GHz ‘, ‘P<31dBm,>3GHz’ and Custom. Spectrum emission mask is applied when all other items except Custom are selected, and by selecting Custom, the file explorer appears as shown in the figure below.INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - Custom

  1.  Select a file.
  2. Click “OK” button at the bottom.
  3. Confirmation of application of spectrum emission mask.

MEASURING ADJACENT CHANNEL POWER (ACP)
The Adjacent Channel Power (ACP) measurement is a method to measure the power over more than one transmission channel and also evaluate the power of the adjacent (or alternate) channels of the transmission channel. The ACP performs measurements according to a specific channel configuration, e.g. a particular radiocommunications standard.
The following parameters need to be configured to perform channel power measurement usingMeasure Setup key ( ):

  • Main Channel Bandwidth to be measured.
  •  Adjacent Channel Bandwidth to be measured.
  • Alternate Channel Bandwidth to be measured.

**** Selecting the frequency span larger than channel bandwidth (> 10%)
If the frequency span is too large in comparison to the channel bandwidth (or the adjacent-channel bandwidths) being examined, only a few points on the trace are available per channel. This reduces the accuracy of the waveform calculation for the channel filter used, which has a negative effect on the measurement accuracy.
The channel bandwidth must be smaller than the frequency span (span > channel bandwidth)

REALTIME SPECTRUM ANALYZER MODE
A realtime spectrum analyzer is a two-dimensional display that contains a line trace that shows the power levels for each frequency for a particular bandwidth or span with the horizontal and vertical axis representing frequency and amplitude. The significant difference to a conventional spectrum analyzer is the way the realtime spectrum analyzer gets its data.
To enter the realtime mode, tab the Home ( ) key or Mode ( ) key and select the “Realtime Spectrum” softkey in the corresponding menu.

The following measurements are available in realtime spectrum analyzer mode

  • Realtime Spectrogram
  • Persistent Density.
  • Persistent Spectrogram.

SCREEN LAYOUT AND ELEMENTS
The following illustrates the screen layout in real-time spectrum analyzer mode. It shows all elements that are the same for all operating modes of the Realtime Spectrum Analyzer. Screen layouts that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide.

A realtime spectrum analyzer is a two-dimensional display that contains a line trace that shows the
power levels for each frequency for a particular bandwidth or span with the horizontal and vertical axis
representing frequency and amplitude. The significant difference to a conventional spectrum analyzer
is the way the realtime spectrum analyzer gets its data.
To enter the realtime mode, tab the Home ( ) key or Mode ( ) key and select the “Realtime Spectrum” softkey in the corresponding menu.

The following measurements are available in realtime spectrum analyzer mode:

  • Realtime Spectrogram.
  •  Persistent Density.
  •  Persistent Spectrogram.

SCREEN LAYOUT AND ELEMENTS
The following illustrates the screen layout in real-time spectrum analyzer mode. It shows all elements that are the same for all operating modes of the Realtime Spectrum Analyzer. Screen layouts that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
CONFIGURING LAYOUT

FUNCTION KEYS
Function keys provide access to the most common measurement settings and functions in the instrument.INNO Instrument 5G SMARTTM Handheld Spectrum
Analyzer - icon 20

A detailed description of the corresponding function is:

Function Key Description
Frequency Sets the center frequency, frequency step size, frequency offset as

well as the start and stop frequencies for the frequency range under consideration.
Amplitude| Sets the reference level, the displayed dynamic range, the RF attenuation, and the unit for the level display.
Sets the level offset and activates the preamplifier
Sweep| Sets the sweep time.
Selects continuous measurement or single measurement
Bandwidth| Sets the resolution bandwidth and select FFT windowing function.
Trigger| Sets the trigger mode, trigger threshold and the trigger delay of the external trigger signal.
Trace| Configures the measured data acquisition and the analysis of the measurement data.
Marker| Sets and positions the absolute and relative measurement markers (markers and delta markers). Marker positioning using peak, next peak.
Provide the following marker functions:
– Marker mode function which provides capability to measure noise, measure frequency using frequency counter.
Limit| Sets the limit and multiple limits on the trace-based.
Measure| This key provides available measurement in the selected mode, and functionality to select and configure measurement such as:
– Realtime Spectrogram
– Persistent Density
– Persistent Spectrogram
Measure Setup| This key provides detailed setup menu available in the selected measurements.
All Settings| This key provides all settings window.

**** Available items in function key can be different per different mode of operations.

SETTING FREQUENCY AND SPAN
The center frequency represents the frequency at the center of the horizontal axis in the measurement result window.
The span is the frequency range around the center frequency that a spectrum analyzer displays on the measurement result screen.

  1. Tab the Frequency key.
  2. Select the “Center Freq” softkey.
  3. Enter the center frequency in an open field. The frequency you have entered becomes the new center frequency.
  4. Select the “Span” softkey.
  5. Enter the span frequency in an open field. The span you have entered becomes the new span frequency.
    ****Span frequency
    Since realtime spectrum analyzer uses FFT up to 100 MHz realtime bandwidth, span frequency limited to 100 MHz.

SETTING START AND STOP FREQUENCY
Defining a start and a stop frequency is best suited for example, for measurements on harmonics or signals whose exact frequency is unknown.

  1.  Tab the Frequency key
  2.  Select the “Start Freq” softkey.
  3.  Enter the start frequency in an open field.
  4.  Set a stop frequency with the “Stop Freq” softkey.
  5. Enter the stop frequency in an open field. The stop frequency you have entered becomes the new stop frequency

**** If you have entered a stop frequency that is outside the maximum frequency range of the instrument, then the realtime spectrum analyzer sets the stop frequency to the possible maximum.

SETTING REFERENCE LEVEL
The reference level is represented graphically by the grid line at the top of the measurement result window. The reference level sets the input signal gain up to the display stage. If the reference level is low, the gain is high. That means that even weak signals are displayed clearly.
If you are measuring strong signals, you have to set a high reference level to prevent an overload of the signal path of the analyzer and to keep the signal within the display range. If you are measuring the spectrum of a composite signal, make sure that the reference level is high enough to cover all signals and that all signals are within the amplitude range of measurement result window.

  1. Tab the Amplitude key.
  2. Select the “Ref Level” softkey.
  3.  Enter the reference level in an open field.
  4.  If you change the reference level, the realtime time spectrum analyzer adjusts the position of the trace as you make the changes.

SETTING ATTENUATION
RF attenuation adjusts the input range inside the analyzer. It is coupled directly to the reference level. If you have set a high reference level, RF attenuation is turned on so that the input mixer always remains in the linear range.

  1. Tab the Amplitude key.
  2.  Select the “Attenuation” softkey.
  3. Enter the attenuation level in an open field (0 to 48 dB in 4 dB step).
  4.  If you change the attenuation, the realtime time spectrum analyzer adjusts the position of the trace as you make the changes.

USING PREAMPLIFIER
To increase the input sensitivity, you can turn on internal pre-amplifier provides an ~20 dB gain. In the default state of the realtime time spectrum analyzer, the preamplifier is turned off. If you want to measure signals with low powers, you can turn it on.

  1. Tab the Amplitude key.
  2. Turn On and Off the “Preamp”.

CHANGING SWEEP TIME
Tab Sweep key ( ) or press Sweep Information box to adjust the sweep time of the spectrummeasurement![INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer

SETTING RESOLUTION BANDWIDTHS
In the realtime spectrum analyzer mode, you can select one of several resolution bandwidth filters and also windowing functions.

  1. Tab the Bandwidth key.
  2.  Select one of several resolution bandwidths from the list.

The following filters are available for the windowing function.

  • Rectangular
  • Hanning
  • Gausian
  •  Blackmann-Harris
  •  Kaiser
  •  Flattop

**** The windowing function is coupled to the resolution bandwidth, therefore the available RBW settings are differ by the selected FFT window type.

Windowing Function Available Bandwidth Settings (Bold indicates default)
Rectangular 78.705 MHz
Hanning 8.28 MHz, 4.14 MHz, 2.07 MHz, 1.035 MHz 258.785 kHz, 129.393 kHz
Gausian 11.025 MHz, 5.423 MHz, 2.689 MHz, 1.393 MHz 669.45 kHz, 334.725 kHz,

151.88 kHz
Blackmann-Harris| 11.274 MHz, 5.558 MHz, 2.745 MHz, 1.373 MHz 686.223 kHz, 343.203 kHz, 168.837 kHz
Kaiser| 12.96 MHz, 6.169 MHz, 3.15 MHz, 1.575 MHz 787.415 kHz, 393.708 kHz, 196.854 kHz
Flattop| 22.12 MHz, 10.891 MHz, 5.401 MHz, 2.678 MHz, 1.339 MHz 674.979 kHz, 334.725 kHz

.
SETTING DETECTOR
The number of measurement results collected in a single sweep usually is extremely high, especially if the span is large. However, the display of the realtime spectrum analyzer can display only 801 results in horizontal direction, as it is limited by the number of pixels that are available on the display. Therefore, it has to combine measurement results to fit them on the display. In that case, one pixel represents a frequency range = span /801.
The detector determines the way the realtime spectrum analyzer combines and displays the results for one pixel.

  1. Tab the Trace key.
  2. Select the “Detector” softkey.
  3.  Select the detector from the submenu. If the “Auto Detector” selection is active, the selection of the trace detector is always “Normal.”

The Realtime Spectrum Analyzer provides several types of detectors.

  • Positive Peak:
    If the positive peak detector is active, the realtime spectrum analyzer displays both the maximum power levels that were measured in the frequency range covered by a pixel.

  • Negative Peak:
    The min peak detector displays sine signals with the correct level and suppresses noise. Therefore it is useful to find sine signals in the vicinity of noise.

  • Sample:
    If the sample detector is active, the realtime spectrum analyzer shows one random power level that was measured in the frequency range covered by a pixel. The sample detector is useful for measurements in the time domain (span = 0 Hz) as it provides the  nly way to represent the timing of the video signal correctly.
    In the frequency domain, the sample detector is an effective way to measure noise power because noise usually has a uniform spectrum with a normal amplitude distribution. Signals may get lost if you are using the sample detector for measurements with a span that is greater than “RBW x 801”.

  • Average:
    If the average detector is active, the realtime spectrum analyzer measures the spectral power over one pixel. The average detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the average detector in combination with a high sweep time.

ADDING MARKER
Tab Marker key ( ) or Tab Marker Shortcut – Peak Search ( ) to set markers on the Realtime spectrum measurement. The marker is placed on the trace move marker position using finger (click and drag). When Marker is enabled, Marker Table will be displayed on the bottom of the measure result with the corresponding frequency and amplitude information.INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - SearchRealtime Spectrum Analyzer supports 6 markers, five of which can be used as either markers or delta markers.

  • Delta:
    Delta marker level is always a relative to the main marker level and so the delta marker level unit is always dB. The delta marker frequency is always relative to the main marker. The delta marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta marker.

  • Delta pair:
    Delta pair marker level is always a relative to the main marker level but it also changes by the signal level. The delta pair marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta pair marker.
    **** Deactivating markers
    If you delete marker 1 (M1), all delta markers that are relative to that marker are also deleted.

MOVING MARKER
Tab and drag on the marker bar or icon to change the marker position in the trace window. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
MOVINGx MARKER

MARKER FUNCTION
In addition to the frequency and level readout, the realtime spectrum analyzer provides two additional marker functions in realtime spectrum analyzer mode.

  •  Noise Marker:
    The marker noise function calculates the noise power density at the marker position in dBm/Hz.
    This involves with the several variables in the calculation of the noise power density, including the trace pixel values, the resolution bandwidth, the detector, and the level display mode (absolute or relative).

CONFIGURING MEASUREMENT
Measure key (   ) provides all available measurements (supported measurement) of the current selected mode. Available measurements may differ from the different modes.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
MEASUREcMENT

Measure Setup key ( ) provides all available configurations (required settings) of the real-time spectrum measurements. The following items are available for realtime spectrum analyzer mode.
In Density view, high density is represented by the color at the top of the color bar and low density by the color at the bottom of the color bar. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - top

USING REALTIME SPECTROGRAM
The realtime spectrum analyzer has 3 different displays, Realtime Spectrogram which combines spectrum and spectrogram, Persistent density that is a two- dimensional histogram that shows the statistical frequency of any frequency and level combinations for every pixel on the display (‘hits’ per pixel) with a probability distribution, and Persistent spectrogram which combines persistent density and spectrogram display. INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - SPECTROGRAM

The spectrogram provides an easy way to monitor the changes of a signal’s frequency and amplitude over time. Typically, it is used for measurements in which time is a factor.
A typical application of a spectrogram is the monitoring of telecommunications systems that are based on frequency hopping techniques, e.g. GSM. Using the spectrogram, you can see at a glance whether slots are allocated correctly or not. In addition, the result display also provides information on the time a particular channel is in use. In telecommunications systems that use frequency hopping techniques, you can use the spectrogram to monitor the settling time to a new frequency after the channel switching. USING PERSISTENT DENSITY (HISTROGRAM)
The persistence spectrum is a three-dimensional histogram that shows the statistical frequency of any frequency and level combinations for every pixel on the display (‘hits’ per pixel). In this view, the X-axis represents frequency, the Y-axis represents amplitude and the Z-axis represents number of hits. This view therefore displays three-dimensional data on a two-dimensional display, using color to represent the third dimension. Persistent density display of the results the realtime spectrum analyzer shows the trace in twodimensions with the number of hits represented by different shades of color. The result is a trace that covers an area instead of a line trace as you know it from the realtime spectrum result display, for example.
USING PERSISTENT SPECTROGRAM
The persistent spectrogram is a combination of spectrogram which is an easy way to monitor the changes of a signal’s frequency and amplitude over time and persistent density include how frequent a certain level and frequency combination has occurred during the measurement INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - combination

LTE-A TDD ANALYZER MODE
The LTE-A TDD Analyzer Mode is targeted for testing the transmitter of the Base Station according to following 3GPP standards.
To enter the LTE-A TDD Analyzer Modes, tab the Home ( ) key or Mode ( ) key and select the “LTE-A TDD Analyzer” softkey in the corresponding menu.
The following measurements are available in LTE-A TDD signal analyzer mode:

  • RF Analysis (Spectrum, Channel Power, Occupied Bandwidth).
  • Power vs Time (Frame, Slot).
  • Modulation Analysis (Constellation, Data Channel, Control Channel, Frame Analysis, Time Alignment Error, Data Allocation Map)
  •  OTA Analysis (Channel Scanner, ID Scanner, Route Map, Control Channel, Datagram)
  •  Carrier Aggregation (Carrier Aggregation)

SCREEN LAYOUT AND ELEMENTS
The following illustrates the screen layout in LTE-A TDD analyzer mode. It shows all elements that are the same for all operating modes of the LTE-A TDD analyzer. Screen layouts that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide.INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - SCREEN LAYOUT AND
ELEMENTS

SETTING CENTER FREQUENCY AND SPAN
The center frequency (channel frequency) represents the frequency at the center of the transmitted channel of the transmitter. The channel center frequency and bandwidth can be set manually. When set to manual channel, the Channel No. is unassigned. When a predefined Channel No. is selected, the uplink and downlink carrier frequencies are set automatically.

  1. Tab the Frequency key.
  2. Select the “Center Freq” softkey.
  3.  Enter the center frequency in an open field. The frequency you have entered becomes the new center frequency

**** Span frequency in LTE-A TDD mode
In LTE mode, span frequency is automatically set by the channel bandwidth. If you select channel bandwidth from bandwidth key, then corresponding span is set automatically (see the table below for span per channel bandwidth)

Channel Bandwidth Span Frequency
1.4 MHz 15 MHz
3 MHz 15 MHz
5 MHz 25 MHz
10 MHz 30 MHz
15 MHz 35 MHz
20 MHz 40 MHz

SETTING REFERENCE LEVEL
The reference level is represented graphically by the grid line at the top of the measurement result window. The reference level sets the input signal gain up to the display stage. If the reference level is low, the gain is high. That means that even weak signals are displayed clearly.
If you are measuring strong signals, you have to set a high reference level to prevent an overload of the signal path of the analyzer and to keep the signal within the display range. If you are measuring the spectrum of a composite signal, make sure that the reference level is high enough to cover all signals and that all signals are within the amplitude range of measurement result window.

  1. Tab the Amplitude key.
  2.  Select the “Ref Level” softkey.
  3.  Enter the reference level in an open field.
  4. If you change the reference level, the LTA-A TDD signal analyzer adjusts the position of the trace as you make the changes.

SETTING ATTENUATION
RF attenuation adjusts the input range inside the analyzer. It is coupled directly to the reference level. If  you have set a high reference level, RF attenuation is turned on so that the input mixer always remainsin the linear range.

  1. Tab the Amplitude key.
  2.  Select the “Attenuation” softkey.
  3.  Enter the attenuation level in an open field (0 to 48 dB in 4 dB step).
  4.  If you change the attenuation, the LTE-A TDD analyzer adjusts the position of the trace as you make the changes.

USING PREAMPLIFIER
To increase the input sensitivity, you can turn on internal pre-amplifier provides an ~20 dB gain. In the default state of the LTE-A TDD analyzer, the preamplifier is turned off. If you want to measure signals with low powers, you can turn it on.

  1. Tab the Amplitude key.
  2.  Turn On and Off the “Preamp”.

SETTING DETECTOR
The number of measurement results collected in a single sweep usually is extremely high, especially if the span is large. However, the display of the LTE-A TDD analyzer can display only 801 results in horizontal direction, as it is limited by the number of pixels that are available on the display. Therefore, it has to combine measurement results to fit them on the display. In that case, one pixel represents a frequency range = span /801.
The detector determines the way the LTE-A TDD analyzer combines and displays the results for one pixel. The data base is the video voltage of the analyzer.

  1. Tab the Trace key.
  2. Select the “Detector” softkey.
  3.  Select the detector from the submenu. If the “Auto Detector” selection is active, the selection of the trace detector is always “Normal.”
    The LTE-A TDD analyzer provides several types of detectors.
  • Positive Peak:
    If the positive peak detector is active, the LTE-A TDD analyzer displays both the maximum power levels that were measured in the frequency range covered by a pixel.

  • Negative Peak:
    The min peak detector displays sine signals with the correct level and suppresses noise. Therefore it is useful to find sine signals in the vicinity of noise.

  •  Sample:
    If the sample detector is active, the LTE-A TDD analyzer shows one random power level that was measured in the frequency range covered by a pixel. The sample detector is useful for measurements in the time domain (span = 0 Hz) as it provides the only way to represent the  timing of the video signal correctly.
    In the frequency domain, the sample detector is a good way to measure noise power because noise usually has a uniform spectrum with a normal amplitude distribution. Signals may get lost if you are using the sample detector for measurements with a span that is greater than “RBW x 801”.

  • Average Voltage:
    If the Average detector is active, the LTE-A TDD analyzer measures the spectral power over one pixel. The Average detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the Average detector in combination with a high sweep time.

  •  RMS:
    If the RMS detector is active, the LTE-A TDD analyzer measures the spectral power over one pixel. The RMS detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the RMS detector in combination with a high sweep time.

ADDING TRACE
Tab Trace key ( ) or press Trace Information box to add traces of the LTE-A TDD spectrum measurement.
How to activate trace(s):

  1. Select Trace (from T1 to T6).
  2. Select Trace Property (Clear Write, Max Hold, Min Hold, View (Capture), Average).
  3. Turn Trace On.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
Max

The LTE-A TDD analyzer provides the following trace modes.

  • Clear/Write:
    In its default state, the LTE-A TDD signal analyzer overwrites the trace after each sweep. You can apply all detectors in this mode.

  •  Average:
    The trace is the result of the moving average over several sweeps. The LTE-A TDD analyzer calculates the (moving) average of the power levels for each pixel over a particular number of sweeps in the range from 1 to 10,000. Averaging reduces the effects of noise but has no effects on sine signals. Using the trace averaging therefore is a good way to detect signals in the vicinity of noise.

  • Max Hold:
    The trace shows the maximum power levels that have been measured at each pixel. To overwrite a max hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the max hold trace mode is a good way to detect intermittent signals or the maximum values of fluctuating signals, for example.

  •  Min Hold:
    The trace shows the minimum power levels that have been measured at each pixel. To overwrite a min hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the min hold trace mode is a good way to highlight signals within noise or suppress intermittent signals.

  • View:
    The view trace mode freezes the current trace and aborts the measurement. Using the view trace mode is a good way to evaluate the trace, for example with markers.

ADDING MARKER
Tab Marker key ( ) or Tab Marker Shortcut – Peak Search ( ) to set markers on the LTE-A TDD spectrum measurement. The marker is placed on the trace move marker position using finger (click and drag). When Marker is enabled, Marker Table will be displayed on the bottom of the measure result with the corresponding frequency and amplitude information. INNO Instrument 5G
SMARTTM Handheld Spectrum Analyzer - Table

LTE-A TDD analyzer supports 6 markers, five of which can be used as either markers or delta markers.

  • Delta:
    Delta marker level is always a relative to the main marker level and so the delta marker level unit is always dB. The delta marker frequency is always relative to the main marker. The delta marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta marker.
    Deactivating markers
    If you delete marker 1 (M1), all delta markers that are relative to that marker are also deleted.

MOVING MARKER
Tab and drag on the marker bar or icon to change the marker position in the trace window.

MARKER FUNCTION
In addition to the frequency and level readout, the LTE-A TDD analyzer provides two additional marker functions in spectrum analyzer mode.

  • Noise Marker:
    The marker noise function calculates the noise power density at the marker position in dBm/Hz.
    This involves with the several variables in the calculation of the noise power density, including the trace pixel values, the resolution bandwidth, the detector, and the level display mode (absolute or relative).

CONFIGURING LTE-A TDD CHANNEL POWER
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD channel power measurements

MEASURING LTE-A TDD CHANNEL POWER
The channel power measurement selectively measures the power of modulated signals. Unlike a power meter that performs measurements over its entire frequency range, the channel power measurement measures the power of a specific transmission channel. Other signals in the frequency spectrum do not show in the results. It determines the total power of the channel by integrating the results on the trace. INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - POWER

CONFIGURING LTE-A TDD OCCUPIED BANDWIDTH
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD occupied bandwidth measurements INNO Instrument
5G SMARTTM Handheld Spectrum Analyzer - configurations

MEASURING LTE-A TDD OCCUPIED BANDWIDTH
The occupied bandwidth is defined as the bandwidth that contains a specified percentage of the entire power of the transmitter. Numerous standards require an occupied bandwidth of 99 which is also the default setting. If you need another percentage for the occupied bandwidth, you can set values from 10 % to 99.9 %. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
OCCUPIED

CONFIGURING LTE-A TDD POWER VS TIME
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A TDD Power vs Time measurements

MEASURING LTE-A TDD FRAME
The Frame measurement provide a power of the frame and subframes with the relevant parameters such as Cell ID, IQ Origin Offset and Time Offset. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - frame

MEASURING LTE-A TDD SLOT
The Slot measurement provide a slot power, DwPTS Avg Power and DwPTS Time.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
DwPTS

CONFIGURING LTE-A TDD MODULATION ANALYSIS
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD Modulation Analysis measurements INNO Instrument
5G SMARTTM Handheld Spectrum Analyzer - CONFIGURING

MEASURING LTE-A TDD CONSTELLATION
The Constellation measurement displays the position of the demodulated signal on the IQ plot. 5G Pro and Smart measures and displays QPSK, 16 QAM, 64 QAM and 256 QAM. Measurement results include RSRP and EVM. INNO Instrument 5G
SMARTTM Handheld Spectrum Analyzer - displays

MEASURING LTE-A TDD DATA CHANNEL
The Data Channel measurement displays the constellation of the selected Resource Block with the relevant parameters such as M-Type(Modulation type), RB Power and EVM(RMS and Peak). It also measures IQ offset in a received signal. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
constellation

MEASURING LTE-A TDD CONTROL CHANNEL
The Control Channel measurement displays the constellation of the selected Control Channel with the relevant parameters such as M-Type(Modulation type) and PBCH EVM(RMS and Peak). It also measures Freq Offset and IQ offset in a received signal. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
MEASURING LTE-A TDD CONTROL CHANNEL

MEASURING LTE-A TDD FRAME ANALYSIS
The Frame Analysis measurement displays the analysis results of the data and control channel of the selected subframe with the relevant parameters such as Frame Avg Power, OFDM Symbol Power, Data EVM(RMS and Peak) and EVM(RMS and Peak). It also measures Freq Offset and IQ Origin Offset in a received signal. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
ANALYSISMEASURING LTE-A TDD TIME ALIGNMENT ERROR
The Time Alignment Error measures and displays the time delay between two signals by analyzing two or more signals flowing into each antenna in TX Diversity system. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
ERROR

MEASURING LTE-A TDD DATA ALLOCATION MAP
The Data Allocation Map measure displays data allocation in frames.INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer -
ALLOCATION

CONFIGURING LTE-A TDD CHANNEL SCANNER
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A TDD Channel Scanner measurements

MEASURING LTE-A TDD CHANNEL SCANNER
The Channel Scanner sequentially analyzes and displays the multi-channel signal coming through the antenna.INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - bottom CHANNEL

CONFIGURING LTE-A TDD ID SCANNER
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD ID Scanner measurementsINNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - CONFIGURING 1

MEASURING LTE-A TDD ID SCANNER
The ID Scanner analyzes and displays multiple signals with different Cell IDs. Analysis results include IDs, RSRP, RSRQ, RS-SINR, RSSI, P-SS and S-SS. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - change
displays

CONFIGURING LTE-A TDD CONTROL CHANNEL
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD Control Channel measurements

MEASURING LTE-A TDD CONTROL CHANNEL
The Control Channel provide analysis results of all control channels over time.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
results

CONFIGURING LTE-A TDD DATAGRAM
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD Datagram measurements INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - DATAGRAM 1

MEASURING LTE-A TDD DATAGRAM
The Datagram displays a spectrum of changes in signal power over time. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer -
MEASURING

CONFIGURING LTE-A TDD CARRIER AGGREGATION
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A TDD Carrier Aggregation measurements

MEASURING LTE-A TDD CARRIER AGGREGATION
The Carrier Aggregation displays the measurement results of multiple LTE carriers used to provide high data rates. INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - multiple1

LTE-A FDD ANALYZER MODE

The LTE-A FDD Analyzer Mode is targeted for testing the transmitter of the Base Station according to following 3GPP standards.
To enter the LTE-A FDD Analyzer Modes, tab the Home ( ) key or Mode ( ) key and select the “LTE-A FDD Analyzer” softkey in the corresponding menu.
The following measurements are available in LTE-A FDD signal analyzer mode:

  • RF Analysis (Spectrum, Channel Power, Occupied Bandwidth).
  • Power vs Time (Frame).
  • Modulation Analysis (Constellation, Data Channel, Control Channel, Frame Analysis, Data Allocation Map).
  • OTA Analysis (Channel Scanner, ID Scanner, Route Map, Control Channel, Datagram)
  •  Carrier Aggregation (Carrier Aggregation).

SCREEN LAYOUT AND ELEMENTS
The following illustrates the screen layout in LTE-A FDD analyzer mode. It shows all elements that are the same for all operating modes of the LTE-A FDD analyzer. Screen layouts that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - ELEMENTS
1

SETTING CENTER FREQUENCY AND SPAN
The center frequency (channel frequency) represents the frequency at the center of the transmitted channel of the transmitter. The channel center frequency and bandwidth can be set manually. When set to manual channel, the Channel No. is unassigned. When a predefined Channel No. is selected, the uplink and downlink carrier frequencies are set automatically.

  1. Tab the Frequency key.
  2.  Select the “Center Freq” softkey.
  3.  Enter the center frequency in an open field. The frequency you have entered becomes the new center frequency

**** Span frequency in LTE-A FDD mode
In LTE mode, span frequency is automatically set by the channel bandwidth. If you select channel bandwidth from bandwidth key, then corresponding span is set automatically (see the table below for span per channel bandwidth)

Channel Bandwidth Span Frequency
1.4 MHz 15 MHz
3 MHz 15 MHz
5 MHz 25 MHz
10 MHz 30 MHz
15 MHz 35 MHz
20 MHz 40 MHz

SETTING REFERENCE LEVEL
The reference level is represented graphically by the grid line at the top of the measurement result window. The reference level sets the input signal gain up to the display stage. If the reference level is low, the gain is high. That means that even weak signals are displayed clearly. If you are measuring strong signals, you have to set a high reference level to prevent an overload of the signal path of the analyzer and to keep the signal within the display range. If you are measuring the spectrum of a composite signal, make sure that the reference level is high enough to cover all signals and that all signals are within the amplitude range of measurement result window.

  1. Tab the Amplitude key.
  2.  Select the “Ref Level” softkey.
  3. Enter the reference level in an open field.
  4. If you change the reference level, the LTA-A TDD signal analyzer adjusts the position of the trace as you make the changes.

SETTING ATTENUATION
RF attenuation adjusts the input range inside the analyzer. It is coupled directly to the reference level. If you have set a high reference level, RF attenuation is turned on so that the input mixer always remains in the linear range.

  1. Tab the Amplitude key.
  2. Select the “Attenuation” softkey.
  3.  Enter the attenuation level in an open field (0 to 48 dB in 4 dB step).
  4.  If you change the attenuation, the LTE-A FDD analyzer adjusts the position of the trace as you make the changes.

USING PREAMPLIFIER
To increase the input sensitivity, you can turn on internal pre-amplifier provides an ~20 dB gain. In the default state of the LTE-A FDD analyzer, the preamplifier is turned off. If you want to measure signals with low powers, you can turn it on.

  1. Tab the Amplitude key.
  2.  Turn On and Off the “Preamp”.

SETTING DETECTOR
The number of measurement results collected in a single sweep usually is extremely high, especially if the span is large. However, the display of the LTE-A FDD analyzer can display only 801 results in horizontal direction, as it is limited by the number of pixels that are available on the display. Therefore, it has to combine measurement results to fit them on the display. In that case, one pixel represents a frequency range = span /801.
The detector determines the way the LTE-A FDD analyzer combines and displays the results for one pixel. The data base is the video voltage of the analyzer.

  1. Tab the Trace key.
  2. Select the “Detector” softkey.
  3.  Select the detector from the submenu. If the “Auto Detector” selection is active, the selection of the trace detector is always “Normal.”
    The LTE-A FDD analyzer provides several types of detectors.
  • Positive Peak:
    If the positive peak detector is active, the LTE-A FDD analyzer displays both the maximum power levels that were measured in the frequency range covered by a pixel.

  • Negative Peak:
    The min peak detector displays sine signals with the correct level and suppresses noise. Therefore it is useful to find sine signals in the vicinity of noise.

  •  Sample:
    If the sample detector is active, the LTE-A FDD analyzer shows one random power level that was measured in the frequency range covered by a pixel. The sample detector is useful for measurements in the time domain (span = 0 Hz) as it provides the only way to represent the timing of the video signal correctly.
    In the frequency domain, the sample detector is a good way to measure noise power because noise usually has a uniform spectrum with a normal amplitude distribution. Signals may get lost if you are using the sample detector for measurements with a span that is greater than “RBW x 801”.

  • Average Voltage:
    If the Average detector is active, the LTE-A FDD analyzer measures the spectral power over one pixel. The Average detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the Average detector in combination with a high sweep time.

  • RMS:
    If the RMS detector is active, the LTE-A FDD analyzer measures the spectral power over one pixel. The RMS detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the RMS detector in combination with a high sweep time.

ADDING TRACE
Tab Trace key ( ) or press Trace Information box to add traces of the LTE-A FDD spectrum measurement.
How to activate trace(s):

  1. Select Trace (from T1 to T6).
  2. Select Trace Property (Clear Write, Max Hold, Min Hold, View (Capture), Average).
  3. Turn Trace On.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
Capture1

The LTE-A FDD analyzer provides the following trace modes.

  • Clear/Write:
    In its default state, the LTE-A FDD signal analyzer overwrites the trace after each sweep. You can apply all detectors in this mode.

  • Average:
    The trace is the result of the moving average over several sweeps. The LTE-A FDD analyzer calculates the (moving) average of the power levels for each pixel over a particular number of sweeps in the range from 1 to 10,000. Averaging reduces the effects of noise but has no effects on sine signals. Using the trace averaging therefore is a good way to detect signals in the vicinity of noise.

  • Max Hold:
    The trace shows the maximum power levels that have been measured at each pixel. To overwrite a max hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the max hold trace mode is a good way to detect intermittent signals or the maximum values of fluctuating signals, for example.

  • Min Hold:
    The trace shows the minimum power levels that have been measured at each pixel. To overwrite a min hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the min hold trace mode is a good way to highlight signals within noise or suppress intermittent signals.

  • View:
    The view trace mode freezes the current trace and aborts the measurement. Using the view trace mode is a good way to evaluate the trace, for example with markers.

ADDING MARKER
Tab Marker key ( ) or Tab Marker Shortcut – Peak Search ( ) to set markers on the LTE-A FDD spectrum measurement. The marker is placed on the trace move marker position using finger (click and drag). When Marker is enabled, Marker Table will be displayed on the bottom of the measure result with the corresponding frequency and amplitude information. INNO Instrument 5G
SMARTTM Handheld Spectrum Analyzer - ADDING MARKER

LTE-A FDD analyzer supports 6 markers, five of which can be used as either markers or delta markers.

  • Delta:
    Delta marker level is always a relative to the main marker level and so the delta marker level unit is always dB. The delta marker frequency is always relative to the main marker. The delta marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta marker.
    **** Deactivating markers
    If you delete marker 1 (M1), all delta markers that are relative to that marker are also deleted.

MOVING MARKER
Tab and drag on the marker bar or icon to change the marker position in the trace window.

MARKER FUNCTION
In addition to the frequency and level readout, the LTE-A FDD analyzer provides two additional marker functions in spectrum analyzer mode.

  • Noise Marker :
    The marker noise function calculates the noise power density at the marker position in dBm/Hz.
    This involves with the several variables in the calculation of the noise power density, including the trace pixel values, the resolution bandwidth, the detector, and the level display mode (absolute or relative).
    CONFIGURING LTE-A FDD CHANNEL POWER
    Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A FDD channel power measurements

MEASURING LTE-A FDD CHANNEL POWER
The channel power measurement selectively measures the power of modulated signals. Unlike a power meter that performs measurements over its entire frequency range, the channel power measurement measures the power of a specific transmission channel. Other signals in the frequency spectrum do not show in the results. It determines the total power of the channel by integrating the results on the trace. INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - CHANNEL POWER 1

CONFIGURING LTE-A FDD OCCUPIED BANDWIDTH
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A FDD occupied bandwidth measurements

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
OCcCUPIED

MEASURING LTE-A FDD OCCUPIED BANDWIDTH
The occupied bandwidth is defined as the bandwidth that contains a specified percentage of the entire  power of the transmitter. Numerous standards require an occupied bandwidth of 99 which is also the default setting. If you need another percentage for the occupied bandwidth, you can set values from 10 % to 99.9 %. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
transmitter.

CONFIGURING LTE-A FDD FRAME
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A FDD Power vs Time measurements

MEASURING LTE-A FDD FRAME
The Frame measurement provide a power of the frame and subframes with the relevant parameters such as Cell ID, IQ Origin Offset, Time Offset and etc. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - provide a
power

CONFIGURING LTE-A FDD MODULATION ANALYSIS
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A FDD Modulation Analysis measurementsINNO Instrument
5G SMARTTM Handheld Spectrum Analyzer - MODULATION

MEASURING LTE-A FDD CONSTELLATION
The Constellation measurement displays the position of the demodulated signal on the IQ plot. 5G Pro and Smart measures and displays QPSK, 16 QAM, 64 QAM and 256 QAM. Measurement results include RSRP and EVM. INNO Instrument 5G
SMARTTM Handheld Spectrum Analyzer - CONSTELLsATION

MEASURING LTE-A FDD DATA CHANNEL
The Data Channel measurement displays the constellation of the selected Resource Block with the relevant parameters such as M-Type(Modulation type), RB Power and EVM(RMS and Peak). It also measures IQ offset in a received signal. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - Power
s

MEASURING LTE-A FDD CONTROL CHANNEL
The Control Channel measurement displays the constellation of the selected Control Channel with the relevant parameters such as M-Type(Modulation type) and PBCH EVM(RMS and Peak). It also measures Freq Offset and IQ offset in a received signal. INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
ANALYSCHANNEL S

MEASURING LTE-A FDD FRAME ANALYSIS
The Frame Analysis measurement displays the analysis results of the data and control channel of the selected subframe with the relevant parameters such as Frame Avg Power, OFDM Symbol Power, Data EVM(RMS and Peak) and EVM(RMS and Peak). It also measures Freq Offset and IQ Origin Offset in a received signal.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer -
data

MEASURING LTE-A FDD DATA ALLOCATION MAP
The Data Allocation Map measure displays data allocation in frames.INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - Map S

CONFIGURING LTE-A FDD CHANNEL SCANNER
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A FDD Channel Scanner measurements

MEASURING LTE-A FDD CHANNEL SCANNER
The Channel Scanner sequentially analyzes and displays the multi-channel signal coming through the antenna. INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - CHANNEL SCANNER

CONFIGURING LTE-A FDD ID SCANNER
Measure Setup key ( ) provides all available configurations (required settings) of the LTE-A FDD ID Scanner measurements

MEASURING LTE-A FDD ID SCANNER
The ID Scanner analyzes and displays multiple signals with different Cell IDs. Analysis results include IDs, RSRP, RSRQ, RS-SINR, RSSI, P-SS and S-SS. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - SCANNERc
S

CONFIGURING LTE-A FDD CONTROL CHANNEL
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A FDD Control Channel measurements ****

MEASURING LTE-A FDD CONTROL CHANNEL
The Control Channel provide analysis results of all control channels over time.INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - FDD CONTROL
CHANNEL S

CONFIGURING LTE-A FDD DATAGRAM
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A FDD Datagram measurementsINNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer -

MEASURING LTE-A FDD DATAGRAM
The Datagram displays a spectrum of changes in signal power over time.INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer - MEASURING LTE-A FDD
DATAGRAM

CONFIGURING LTE-A FDD CARRIER AGGREGATION
Measure Setup key (   ) provides all available configurations (required settings) of the LTE-A FDD Carrier Aggregation measurements

MEASURING LTE-A FDD CARRIER AGGREGATION
The Carrier Aggregation displays the measurement results of multiple LTE carriers used to provide high data rates.INNO Instrument 5G SMARTTM Handheld
Spectrum Analyzer - multiple

5GNR SIGNAL ANALYZER MODE
The 5GNR Signal Analyzer Mode is targeted for testing the transmitter of the Base Station according to following 3GPP standards (Release 15).
To enter the 5GNR signal analyzer mode, tab the Home ( ) key or Mode ( ) key and select the “5GNR Signal Analyzer” softkey in the corresponding menu.
The following measurements are available in 5GNR signal analyzer mode:

  • RF Analysis (Spectrum, Channel Power, Occupied Bandwidth).
  •  Beam Analysis (Multi Beam, Single Beam).

SCREEN LAYOUT AND ELEMENTS
The following illustrates the screen layout in 5GNR signal analyzer mode. It shows all elements that are the same for all operating modes of the 5GNR signal analyzer. Screen layouts that show specifics for each operating mode or measurement are provided in the corresponding sections of this guide. INNO
Instrument 5G SMARTTM Handheld Spectrum Analyzer -
corresponding

SETTING CENTER FREQUENCY AND SPAN
The center frequency (channel frequency) represents the frequency at the center of the transmitted channel of the transmitter. The channel center frequency and bandwidth can be set manually. When set to manual band, the ARFCN is unassigned. When a predefined ARFCN is selected, the uplink and downlink carrier frequencies are set automatically.

  1. Tab the Frequency key.
  2.  Select the “Center Freq” softkey.
  3. Enter the center frequency in an open field. The frequency you have entered becomes the new center frequency
    **** Span frequency in 5GNR mode
    In 5GNR mode, span frequency is automatically set by the channel bandwidth. If you select channel bandwidth from bandwidth key, then corresponding span is set automatically (see the table below for span per channel bandwidth)
Channel Bandwidth Span Frequency
5 MHz 15.36 MHz
10 MHz 15.36 MHz
15 MHz 30.72 MHz
20 MHz 30.72 MHz
25 MHz 30.72 MHz
30 MHz 61.44 MHz
40 MHz 61.44 MHz
50 MHz 61.44 MHz
60 MHz 122.88 MHz
70 MHz 122.88 MHz
80 MHz 122.88 MHz
90 MHz 122.88 MHz
100 MHz 122.88 MHz

SETTING REFERENCE LEVEL
The reference level is represented graphically by the grid line at the top of the measurement result window. The reference level sets the input signal gain up to the display stage. If the reference level is low, the gain is high. That means that even weak signals are displayed clearly.
If you are measuring strong signals, you have to set a high reference level to prevent an overload of the signal path of the analyzer and to keep the signal within the display range. If you are measuring the spectrum of a composite signal, make sure that the reference level is high enough to cover all signals and that all signals are within the amplitude range of measurement result window.

  1. Tab the Amplitude key.
  2.  Select the “Ref Level” softkey.
  3. Enter the reference level in an open field.
  4.  If you change the reference level, the 5GNR signal analyzer adjusts the position of the trace as you make the changes.

SETTING ATTENUATION
RF attenuation adjusts the input range inside the analyzer. It is coupled directly to the reference level. If you have set a high reference level, RF attenuation is turned on so that the input mixer always remains in the linear range.

  1. Tab the Amplitude key.
  2. Select the “Attenuation” softkey.
  3.  Enter the attenuation level in an open field (0 to 48 dB in 4 dB step).
  4.  If you change the attenuation, the 5GNR signal analyzer adjusts the position of the trace as you make the changes.

USING PREAMPLIFIER
To increase the input sensitivity, you can turn on internal pre-amplifier provides an ~20 dB gain. In the default state of the 5GNR signal analyzer, the preamplifier is turned off. If you want to measure signals with low powers, you can turn it on.

  1. Tab the Amplitude key.
  2.  Turn On and Off the “Preamp”.

SETTING DETECTOR
The number of measurement results collected in a single sweep usually is extremely high, especially if the span is large. However, the display of the 5GNR signal analyzer can display only 801 results in horizontal direction, as it is limited by the number of pixels that are available on the display. Therefore, it has to combine measurement results to fit them on the display. In that case, one pixel represents a frequency range = span /801.
The detector determines the way the 5GNR signal analyzer combines and displays the results for one pixel. The data base is the video voltage of the analyzer.

  1. Tab the Trace key.
  2.  Select the “Detector” softkey.
  3.  Select the detector from the submenu. If the “Auto Detector” selection is active, the selection of the trace detector is always “Normal.”

The 5GNR signal analyzer provides several types of detectors.

  • Positive Peak:
    If the positive peak detector is active, the 5GNR signal analyzer displays both the maximum power levels that were measured in the frequency range covered by a pixel.

  • Negative Peak:
    The min peak detector displays sine signals with the correct level and suppresses noise. Therefore it is useful to find sine signals in the vicinity of noise.

  • Sample:
    If the sample detector is active, the 5GNR signal analyzer shows one random power level that was measured in the frequency range covered by a pixel. The sample detector is useful for measurements in the time domain (span = 0 Hz) as it provides the only way to represent the timing of the video signal correctly.
    In the frequency domain, the sample detector is a good way to measure noise power because noise usually has a uniform spectrum with a normal amplitude distribution. Signals may get lost if you are using the sample detector for measurements with a span that is greater than “RBW x 801”.

  • Average Voltage:
    If the Average detector is active, the 5GNR signal analyzer measures the spectral power over one pixel. The Average detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the Average detector in combination with a high sweep time.

  •  RMS:
    If the RMS detector is active, the 5GNR signal analyzer measures the spectral power over one pixel. The RMS detector is best for measurements on digitally modulated signals because it provides stable and true power readings. In combination with a high sweep time, you can increase the display stability even more because the measurement time for each pixel increases. Noise measurements also provide stable results if you apply the RMS detector in combination with a high sweep time.

ADDING TRACE
Tab Trace key ( ) or press Trace Information box to add traces of the 5GNR spectrum measurement.
How to activate trace(s):

  1. Select Trace (from T1 to T6).
  2.  Select Trace Property (Clear Write, Max Hold, Min Hold, View (Capture), Average).
  3.  Turn Trace On.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - ADDING
tracesThe 5GNR signal analyzer provides the following trace modes.

  • Clear/Write:
    In its default state, the 5GNR signal analyzer overwrites the trace after each sweep. You can apply all detectors in this mode.

  • Average: The trace is the result of the moving average over several sweeps. The 5GNR signal analyzer calculates the (moving) average of the power levels for each pixel over a particular number of sweeps in the range from 1 to 10,000. Averaging reduces the effects of noise but has no effects on sine signals. Using the trace averaging therefore is a good way to detect signals in the vicinity of noise.

  • Max Hold:  The trace shows the maximum power levels that have been measured at each pixel. To overwrite a max hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the max hold trace mode is a good way to detect intermittent signals or the maximum values of fluctuating signals, for example.

  • Min Hold: The trace shows the minimum power levels that have been measured at each pixel. To overwrite a min hold trace, change a parameter in a way that the results cannot be compared any more (e.g. the span). Using the min hold trace mode is a good way to highlight signals within noise or suppress intermittent signals.

  • View: The view trace mode freezes the current trace and aborts the measurement. Using the view trace mode is a good way to evaluate the trace, for example with markers.

ADDING MARKER
Tab Marker key ( ) or Tab Marker Shortcut – Peak Search ( ) to set markers on the 5GNR spectrum measurement. The marker is placed on the trace move marker position using finger (click and drag). When Marker is enabled, Marker Table will be displayed on the bottom of the measure result with the corresponding frequency and amplitude information.

INNO Instrument 5G SMARTTM Handheld Spectrum Analyzer - ADDING
Table

5GNR signal analyzer supports 6 markers, five of which can be used as either markers or delta markers.

  • Delta:
    Delta marker level is always a relative to the main marker level and so the delta marker level unit  is always dB. The delta marker frequency is always relative to the main marker. The delta marker frequency is the frequency difference between the frequency at the point marked by the main marker and the frequency at the point marked by the delta marker.
    Deactivating markers
    If you delete marker 1 (M1), all delta markers that are relative to that marker are also deleted.
    MOVING MARKER
    Tab and drag on the marker bar or icon to change the marker position in the trace window.

MARKER FUNCTION
In addition to the frequency and level readout, the 5GNR signal analyzer provides two additional marker functions in spectrum analyzer mode.

  • Noise Marker:
    The marker noise function calculates the noise power density at the marker position in dBm/Hz.
    This involves with the several variables in the calculation of the noise power density, including the trace pixel values, the resolution bandwidth, the detector, and the level display mode (absolute or relative).
    CONFIGURING 5GNR CHANNEL POWER
    Measure Setup key ( ) provides all available configurations (required settings) of the 5GNR channel power measurements

MEASURING 5GNR CHANNEL POWER
The channel power measurement selectively measures the power of modulated signals. Unlike a power meter that performs measurements over its entire frequency range, the channel power measurement measures the power of a specific transmission channel. Other signals in the frequency spectrum do not show in the results. It determines the total power of the channel by integrating the results on the trace.

CONFIGURING 5GNR OCCUPIED BANDWIDTH
Measure Setup key (   ) provides all available configurations (required settings) of the 5GNR occupied bandwidth measurements

MEASURING 5GNR OCCUPIED BANDWIDTH
The occupied bandwidth is defined as the bandwidth that contains a specified percentage of the entire power of the transmitter. Numerous standards require an occupied bandwidth of 99 which is also the default setting. If you need another percentage for the occupied bandwidth, you can set values from 10 % to 99.9 %.

CONFIGURING 5GNR DEMODULATION MEASUREMENT
Measure Setup key ( ) provides all available configurations (required settings) of the 5GNR demodulation measurements.INNO Instrument 5G SMARTTM
Handheld Spectrum Analyzer - ADDING MOVING BEAM

MEASURING 5GNR MULTI BEAM
The multi beam measurement provide a maximum 8 beams with the relevant parameters such as RSRP, RSRQ, SINR include Cell site information of Cell ID, Sector ID, and Group ID. It also measures frequency and time offset in a received signal.

MEASURING 5GNR SINGLE BEAM
The single beam measurement provides beam specific parameters such as EVM RMS and Peak. All 8 beams can be measured and you can navigate using page indicator on the bottom of the measurement result window.

UPGRADING SOFTWARE LICENSE
Upgrading software licenses for options consists of two main steps:

  1. Send the unit’s license information to INNO.
  2.  Import the new license file provided by INNO.

CHECKING A LICENSE INFORMATION

  1. Plug USB flash drive to the instrument.
  2.  Open the System menu (   ) from the shortcut icon.
  3.  Navigate to License Manager.
  4.  Tab SAVE LICENSE INFORMATION (This will export license information to USB flash drive).
  5.  Email the file to INNO.

IMPORTING SOFTWARE LICENSE

  1. After receiving a new license file from INNO, place the file on the USB flash drive in the top (root) level, not in any directory.
  2.  Plug USB flash drive contains the new license file to the instrument.
  3.  Open the System menu ( ) from the shortcut icon.
  4.  Navigate to License Manager.
  5.  Tab ENABLE OPTIONS USING FILE.
  6.  The instrument will search for a valid license file on the USB flash drive and apply the changes to the system.
  7.  Restart the instrument and ensure all changes are applied.

www.innoinstrument.com
Visit us at www.innoinstrument.com
Copyright ⓒ2019 INNO Instrument Inc. All rights reserved.
E-22F, 30, Songdomirae-ro, Yeonsu-gu, Incheon 21990, Republic of Korea
5G SMART & 5G PRO SPECTRUM ANAYZER USER GUIDE
101 tel 82 32 837 5600 fax 82 32 837 5601 5G SMART / 5G PRO Spectrum Analyzer User Guide Rev. 1.3
Product specifications and descriptions in this document subject to change without notice

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

iNNO INSTRUMENT User Manuals

Related Manuals