CG36FSAC02 3.00 Ton Inspiring Life Instruction Manual
- June 13, 2024
- CG
Table of Contents
FLOOR STANDING AC
INSTRUCTION MANUAL
Read this manual carefully before operation
Pictures in this manual are for reference only, the product in kind prevail.
CG-36FSACO02
Floor Type Room Air Conditioner
Preparation before use
Before using the air conditioner, be sure to check and preset the following.
-
Remote Controller presetting
Each time after the remote controller replaces batteries or is energized, remote controller auto presetting heat pump. If the air conditioner you purchased is a cooling only one, but you preset the remote controller as Heat pump, it doesn’t bring any matter. -
This air conditioner has been designed for the following temperatures.
Operate it within this range. Series| Model| Mode| Outdoor working temperature (°C)
---|---|---|---
maximum| minimum
Cooling only type| 18K| Cooling Operation| 43| 15
24K| Cooling Operation| 48| 15
Heat pump type| 24K/30K/36K| Cooling Operation| 52| 15
Heating Operation| 24| -10 -
Storage condition:
Temperature -25°C~60°C
Humidity 30%~80% -
NOTES
Heating and electric heating function are not available in single cooling only models.
CAUTION Statements
Alert Symbols:
DANGER: The symbol refers to a hazard which can result in severe personal
injury or death.
WARNING: The symbol refers to a hazard or an unsafe practice which may
result in severe personal
injury or death.
CAUTION: The symbol refers to a hazard or an unsafe practice which may
result in personal injury, product or property damage.
NOTE : It refers to the remarks and instruction to the operation,
maintenance and service.
-
We recommend that this air conditioner is installed properly by qualified installation technicians in accordance with the installation instructions provided with the unit.
-
Before installation, check if the voltage of the power supply at installation site is the same as the voltage shown on the nameplate.
-
The appliance shall also be installed in accordance with national wiring regulations.
DANGER:
-
Do not perform any alterations to this product, otherwise, it may possibly cause such consequences as water leakage, breakdown, short-circuit, electric shock, fire and S0 on.
-
Piping and welding work should be carried out far away from the flammable explosive material vessels, including the air-conditioner refrigerant, to guarantee the security of the site.
-
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salt water can splash directly onto it or in sulphurous air near a spa. Do not install the air conditioner where excessively high heat-generating objects are
placed.
WARNING:
-
If the supply cord is damaged, it must be replaced by the factory or its service department to avoid danger.
-
The place where this product is installed must have the reliable electrical earth facility and protections. Please do not connect the grounding of this product to various kinds of air-feeding ducts, drain piping, lightning protection facility as well as other piping lines to avoid receiving an electric shock and damages caused by other factors.
-
Wiring must be done by a qualified electrician. All the wiring must comply with the local electrical codes.
-
Consider the capacity of the electric current of your electrical meter and socket before installation.
-
The power wire where this product is installed should have independent leakage protective device and the electric current over-load protection device provided for this product.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge of using air-conditioner, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
-
Means for disconnection, which can provide full disconnection in all poles, must be incorporated in the fixed wiring in accordance with the wiring regulations.
-
The cord of the HO7RN-F type or the electrically equivalent type must be used for power connection and interconnection between outdoor unit and indoor unit. The size of the cord is detailed below.
-
Details of type and rating of fuses, or rating of circuit breakers / ELB is detailed below.
If the fuses in units burn up, please call the service agency to change it.
Please do not change it by yourself, or else may result in accident, for example shock. -
The wiring diagram with a clear indication of the connections and wiring to external control devices and supply cord are detailed below.
-
The method of connection of the appliance to the electrical supply and interconnection of separate components are detailed below.
-
It is necessary to allow disconnection of the appliance from the supply after installation.
The disconnection may be achieved by incorporating a switch in the fixed wiring in accordance with the wiring rules. -
CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out.
this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. -
The information of dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures is detailed below.
-
Instructions on addition charging of refrigerants are detailed below.
-
-
Read this manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
-
The air cond itioner is designed to provide you with comfortable room conditions. Use this unit only for its intended purpose as described in this instruction manual.
****WARNING:-
Never use gasoline or other inflammable gas near the air-conditioner, which is very dangerous.
-
When the air conditioner operation is abnormal, such as burnt smell, deformation, fire, smoke, etc., it is forbidden to continue using the air conditioner, the main power switch of the air conditioner must be cut off immediately and the agent must be contacted.
CAUTION
-
Do not turn the air conditioner on and off from the power main switch. Use the ON/OFF operation button.
-
Do not stick anything into the air inlet and air outlet of both the indoor and outdoor units. This is dangerous because the fan is rotating at a high speed.
-
Do not cool or heat the room too much if babies or invalids are present.
-
Precaution
Symbols in this Use and Care Manual are interpreted as shown below.
Be sure not to do.
Pay attention to such a situation.
Be sure to follow this instruction.
Grounding is essential.
Warning: Incorrect handling could cause a serious hazard, such as death, serious injury, etc.
Use correct power supply in accordance with the rating plate requirement
Otherwise, serious faults or hazard may occur or a fire maybe break out.|
Keep the power supply circuit breaker from dirt and connect the power supply
cord with it firmly and correctly, lest electric shock or fire be caused by a
wrong wiring| Do not clean the appliance with gasoline, basic or acid
detergent
---|---|---
Do not knit, pull or press the power supply cord, lest the power supply cord
be broken.
An electric shock or fire is probably caused by a broken power supply cord|
Never insert a stick or similar obstacle to the unit. Since the fan rotates
at high speed, this may cause an injury.| Itis harmful to your health if the
cool air reaches you for a long time. It is advisable to let the air flow be
deflected to all the room.
Stop the appliance and then turn off the power supply circuit breaker
immediately when something is wrong during operation.| Itis advisable to
install, repair or move the appliance by a licenced person.| Itis the user’s
responsibilty to make the appliance be grounded according to local codes or
ordinances by a licenced technician.
Do not employ the appliance to dry clothes or cool food, ete.| Do not put any
objects on the outdoor unit.| Itis the user’s responsibilty to make the
appliance be grounded according to local codes or ordinances by a licenced
technician.
Identification of parts
Indoor Unit
This figure is based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner you have
selected.
Display Introduction
Display and Button Introduction
- Button Operation
1. ON/OFF BUTTON
For turning on/off the appliance.
2. TEMPERATURE SETTING BUTTONS
Used to adjust the set temperature.
Every pressing button can raise the temperature by 1°C;
Every pressing button can reduce the temperature by 1°C.
3. MODE BUTTON
For selecting the operation mode.
Each time “MODE” button is pressed, the operation mode is changed in sequence:
4. FAN SPEED BUTTON
For selecting indoor fan speed.
Each time “FAN “/ “FAN SPEED” button is pressed, the fan speed is changed in sequence:
“AUTO” fan speed is invalid when select“FAN ONLY”mode.
“FAN”/ “FAN SPEED” button is invalid when select “DRY”mode.
“/”is unavailable in some models.
It can also used to unlock user interface.
The user interface will lock automatically if idle beyond 1 minute, then the
user interface will be locked;
Hold the “FAN” / “FAN SPEED” button for 3 seconds to unlock; The remote
control is still usable when the user interface has locked.
- Display Introduction
1. Auto mode display: Display during auto mode.
2. Cooling mode display: Display during cooling mode.
3. Dry mode display: Display during dry mode.
4. Fan only mode display: Display during fan only mode.
5. Heating mode display: Display during heating mode.
6. Temperature display: Display indoor set temperature or indoor temperature.
7. Heater display: It lights up during heating mode when electric heater is on (Only valid for models with electric heater).
8. 9. 10. 11. Fan speed set display.
8. Auto fan speed display: It lights up during the appliance is set with auto fan speed.
9. High fan speed display: It lights up during the appliance is set with high fan speed.
10.Medium fan speed display: It lights up during the appliance is set with medium fan speed.
11.Low fan speed display: It lights up during the appliance is set with low fan speed.
12. Signal Receptor.
13. Timer mode display: It lights up during timer on/timer off mode.
14.Sleep mode display: It lights up during sleep mode, and the LCD will stop lighting after 10 seconds.
15.Button locked display: It lights up when the user interface has been locked.
16.Temperature indicator:
Display indoor temperature when lights up;
Display outdoor temperature when lights up;
Display indoor set temperature when and all go off.
17.Temperature display:
Display indoor set temperature, indoor temperature or outdoor temperature.
Default display indoor set temperature.
18.Limit temperature set indicator:
It indicates that the set temperature allowed has reached the max. valve when & lights up;
It indicates that the set temperature allowed has reached the min. valve when lights up.
Maintenance
Maintain the indor unit
-
Cut off the power supply
-
Wipe the appliance with a soft and dry cloth.
The water temperature should be below 40°C. -
Never use volatile substance such as gasoline and polishing powder to clean the appliance.
-
Never sprinkle water to the indoor unit.
-
Dry the appliance.
Operate the appliance at FAN ONLY mode on a fine day for about half a day to dry the internal components of the indoor unit.
Clean the air filter
-
Switch off the power supply circuit and remove air filters as following.
The installation or remove of air filters must by an adult in order to avoid a hazard. -
Clean air filters
Wipe the air filters with a soft cloth or pat it lightly, or clean it with a dust arrester or warm water containing neutral detergent when it is very dirty. Then dry it in a shaded and cool place. -
Put the air filters back to the unit.
Clean the air filters when the appliance has operated for over 300 hours.
Clean the air filters every two weeks if the air conditioner operates in an extremely dusty environment.
Protection
Operating condition
The protective device may trip and stop if it is operated outside allowed
temperature range.
If the air conditioner runs in COOLING or DRY mode with door or window opened
for a long time when relative humidity is above 80%, dew may drip down from
the outlet.
Noise pollution
- Install the air conditioner at a place that can bear its weight and ensure the quiet operation.
- Install the outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbors.
- Do not place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level.
Features of protector
-
The protective device will work at following cases.
• Restarting the unit at once after operation stops or changing mode during operation, please wait for 3 minutes.
• Connect to power supply and turn on the unit at once, it may start 20 seconds later. -
• If all operation has stopped, press ON/OFF button again to restart, Timer should be set again if it has been canceled.
Features of HEATING mode
Preheating
At the beginning of HEATING operation, the airflow from indoor unit is
discharged 2-5 minutes later.
Defrosting
During HEATING operation the appliance will defrost automatically to improve
efficiency. This procedure usually lasts for 2-10 minutes. During defrosting,
fans stop operation. After defrosting completes, it returns to “HEATING” mode
automatically.
It is hard to increase the room temperature when outdoor temperature is very
low. It might take longer time if the working temperature range not closer to
the operation limits.
Heating is NOT available for cooling only air conditioner models.
Trouble Shooting
The following cases may not always be a problem, please check it before asking for service.
Trouble | Analysis |
---|---|
Does not run | • If the protector trips or fuse is blown. |
• If the leakage breaker trips.
• If the plug loosened.
• Sometimes it stops working to protect the appliance.
Not cool or warm enough | • Is the air filter dirty?
• Are the intakes and outlets of the air conditioner blocked?
• Is the temperature set properly ?
Ineffective control | • If strong interference (from excessive static
electricity discharge, power supply voltage abnormality)presents, sometimes
operation will be affected. In this case, switch off the breaker and switch
on it again 2~3 seconds later.
Does not operate immediately | • Shifting to other modes during operation,
wait 3 minutes to start.
Peculiar odor | • Odor may come from sources such as furniture or cigarette
and blown out by the unit.
A sound of running-water | • Caudsed by the‘flow of refrigerant inside the air
conditioner, not a failure.
A”pi-pa” sound can be heard | • Caused by the expansion or contraction of the
internal components due to temperature changes.
That is not a failure.
Blow mist from the outlet | • Room air is cooled down by the cold air blown
out from the unit and mist thus form during “COOLING” or “DRY” mode when
humidity is too high inside.
Installation Instructions
Installation diagram of air conditioner
Distance
a/mm| 100
b/mm| 300
c/mm| 100
d/mm| 350
e/mm| 500
- Please install the air conditioner according to international rules.
- Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased.
- Do not put any things that could cause fire in the label area.
Installation locations
-
Location for installing indoor unit
1. No obstacle around the air outlet and air flow can spread to the whole room.
2. ltis easy to arrange connection pipe and drill a wall hole.
3. Keep a required distance from the ceiling and wall as illustrated on the figure of the previous page.
4. Easy to take down and install the air filter.
5. Keep the unit a distance of over 1 meter away from a TV set, radio etc. that may arouse interference.
6. Do not put anything around the air intake.
7. Install it at a place that can bear the weight of it and would not increase noise and vibration during operation.
8. Avoid installing it where there is much oily smoke, salty, sulfide gas, dust and direct sunlight. -
Location for installing outdoor unit
1. Install it at a place where it is convenient for installation and well ventilated.
2. Keep the required distance away from the wall as required on the previous page when carrying on installation.
3. Pipe length and drop height should comply with the scope required below.Model| 18K| 24K| 30K/36K
---|---|---|---
Max. pipe length| 20m| 30m| 30m
Max. drop height| 15m| 15m| 20m
Oil trap| every 5m| | every 5m| every 5m
4. When operating at a special place, for example, a place of greasy dirt,
vulcanization gas or high-salty seashore, make sure to adopt an effective
isolation measure.
5. Avoid installing it on the roadside where there is a risk of muddy water.
6. Install it where your neighbors would not be annoyed by operating noise or
discharged hot air.
7.Install it on a fixed shelf that is not subject to increasing noise.
8. Install it at a place without blockage for air outlet.
Wall hole
- The hole should slide down towards outside for easy drainage.
- Install the wall sleeve into the wall hole to prevent the pipes and cables from being damaged.
- Put on the attached wall sleeve and sleeve cap to keep the wall tidy and clean.
Pipe direction
Indoor piping, drainage and wiring can be arrange at 3 optional directions
Select a most suitable one for installation convenience.
A. Backward direction | B. Left or right direction |
---|---|
Outdoor unit installation
1. Fix the outdoor unit with 4 bolts, 4 washers and 4 nuts to prevent it from
noise and vibration.
2. The installation dimensions are as following.
Model Capacity
(Btu/h)| A| B| C| D| E| F| d
---|---|---|---|---|---|---|---
18K| 810| 280| 510| 310| 338| 150| 10 X17
24K| 860| 310| 542| 341| 368| 168| 11 x 17
30K/36K| 890| 365| 662| 390| 414| 112| 12 x 18
Pipes connection
-
Remove the air intake grille
a. Loosen the 4 Philips screws and remove the air intake grille. b. Reinstall the air intake grille after piping connection of indoor unit has been finished. -
Remove the two flared nuts attached on indoor pipes.
a. Draw the connecting pipes from outside of the indoor unit cabinet to inside, and take away the plastic seal caps from their ends.
b. Itis convenient to connect to the indoor unit connector with a L-shape pipe. -
Connect the connecting pipes to indoor unit connectors.
a. Make sure to keep the indoor pipes and connecting pipes at the same axial line while connecting.
b. Turn the flared nuts clockwise with your hands at first, then tighten with torque wrenches.
c. Pay attention to the allowed torque as shown on right table to prevent the pipes, connectors and flared nuts from being deformed and damaged. -
Thermal insulation for connecting joints.
****Tube size| Torgue (N – m)
---|---
ø 6.35mm| 20
ø 9.52mm| 40
ø 12.7mm| 60
ø 15.88mm| 80
ø 19.05mm| 100
Itis advisable to wrap the connecting joints, lest condensate generates and drips. The liquid and gas pipes should be wrapped respectively.
- Connect the connecting pipes to the outdoor unit.
**** ****Model
Capacity(Btu/h),| as pipe| Liquid pipe
---|---|---
18K| ø 12.7mm| ø 6.35mm
24K/30K/36K| ø 15.88mm| ø 9.52mm
a. Remove the flared nuts from 2-way valve and 3-way valve.
b. Take away the plastic seal caps from the connecting pipes.
c. Tighten the flared nuts with your hands at first, and then with torque
wrenches, making sure connectors and the pipes are kept on the same axial
line. Pay attention to the torque required.
Air exhaust
Air and moisture remains inside the refrigeration system, may has the following bad effects:
- Rise of pressure inside the refrigeration system;
- Decrease of cooling (or heating) effect;
- Moisture frozen and blocking the refrigeration system;
- Rusting of certain parts of the system
After connecting the indoor and outdoor units, it is necessary to exhaust the air inside the pipes completely as follows:
Air exhaust process:
- Unscrew and remove caps from the stop valves.
- Connect vacuum pump flexible hose to the service valve.
- Start vacuum pump for 10-15 minutes until reaching a vacuum of 10mmHg absolutes.
- With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop vacuum pump.
- Open 2-way valve 1/4 turn then close it after 10 seconds. Check tightness of all joints using liquid soap or an electronic leak detector.
- Turn 2 and 3-way valves stem to fully the valves. Disconnect vacuum pump flexible hose.
- Replace and tighten all valve caps.
After exhausting, use electronic leakage detector or soapsuds to check all pipe connecting portions of outdoor and indoor units.
Charge additional refrigerant
The refrigerant charge volume for the unit is based on using a 5m connecting pipe. If the connecting pipe’s length is longer than 5m, it is advisable to charge additional refrigerant for the unit in order to achieve better operation.
Model
Capacity(Btu/h)| Additional Refrigerant
---|---
18K| (L5)X0.015 kg
24K/30K/36K| (L-5)X0.035 kg
(* “L” refers to length of connection pipe.)
The additional Refrigerant should be charged from the service port of the
3-way valve when the appliance is operating in cooling mode.
Do not allow air enter the refrigeration system while charging Refrigerant.
Drainage arrangement
- Arrange the drainage pipe from wall to outdoor.
- Slide down the drainage pipe for easy drainage.
- Connect the attached drain hose to indoor drainage pipe and stick them well to prevent condensate from leaking.
- Wrap the indoor part of drainage pipe with thermal insulation material.
Wrap the piping
- Wrap the connecting pipes and cables together with tape, but not including the drainage pipe. Drainage pipe can be fixed along them separately.
- Wrapping from the joint of outdoor unit to that of indoor unit, each round of tape should cover half of its previous one.
Wiring connection
-
Important notice
• It is the user’s responsibility to make external wiring connection be finished correctly.
• The external wiring must be conducted by a licensed electrician and complies with local codes or ordinances.
• Special attention must be paid to the power supply (as per rating plate).
• The Suitable power supply of your appliance has been shown on rating label.
• The appliance must ground correctly. The earth wire should be prepared by user.
• Never change the internal wiring of your appliance randomly. -
Steps of external wiring connection
1. Remove air intake grille and electric box cover of indoor unit.
2. Remove access door of outdoor unit.
3. Connect the power supply connecting cable between indoor and outdoor unit.
Please refer to the following pages for details.
4. Make sure the cables being fixed well with an effective anchorage after connecting.
5. Grounding work must be carried out for indoor and outdoor units.
6. Install the components removed back to the unit.
-
External wiring diagrams
-
Cable specification
Model Capacity (Btu/h)| Power Supply| ELB| Power Source Cable Size| Connecting Cable Size| Circuit Breaker(A)
---|---|---|---|---|---
Nominal Current(A)| Nominal Sensitive
Current (mA)| EN60335-1| EN60335-1
18K| 220-240V -,50Hz| 20| 30| 3 x 2. 5mm2| 3 x 1.5mm2| 20
24K (Cooling only type)| 220-240V -,50Hz| 25| 30| 3 x 2. 5mm2| 5 x 1.5mm2| 25
24K (Heat pump type)| 220-240V -,50Hz| 32| 30| 3 X 4. Omm2| 3 x O. 75mm2
3 X 1.5mm2
2 X 0.3mm| 32
30K/36K| 220-240V -,50Hz| 40| 30| 3 X 4. Omm2| 3 x 1. 5mm2
3 X 1. 5mm2
2 x 0.3mm2| 40
1. Above section area for cables is a minimum one. If the connection between
indoor and outdoor unit is very long, it is advisable to employ a cable with a
larger class to avoid decreasing of voltage.
2. The earth wire for the whole unit should be 4.0mm’, and prepared by user.
To be in compliance with IEC 61000-3-11, the product shall be connected only
to a supply of the system impedance:|Zsys| <0.018Q (for heat pump type).
Before connecting the product to public power network, please consult your
local power supply authority to ensure the power network meet above
requirement.
- Electrical work
Make sure that the color of wires of the outdoor unit and the terminal No. are the same as those of the indoor unit.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Test run
Before testing
a. Check if piping, drainage and external wiring have been finished correctly.
b. Check if the power supply complies with requirements; if there is
refrigerant leakage; if the all wires and cables are correctly connected and
well fixed.
Function test
a. After checking, energize your appliance and press the buttons on the
control panel to see if the buttons function;
b. If screen displays normally.
Notes
- Please read this operating and installation instructions carefully.
- Do not let air in or refrigerant out during installing or reinstalling the appliance.
- Test run the air conditioner after finishing installation and keep the record.
- The air conditioner operates safely when ambient static pressure is 0.8~1.05 standard atmosphere pressure.
- When charging refrigerant into the system, make sure to charge in liquid state.
- Otherwise, chemical composition of refrigerant inside the system may change and thus affect performance of the air conditioner.
- The circuit of fastness connecting to the user must have all poles broken device (contact clearance is 3mm).
A Quality Product
of Visitus at:/www.cginspiringlife.com/