OXBOX JMM4A0A18S21SA Wall Mount Air Handlers Ton Cooling Heat Pump User Manual
- June 13, 2024
- Oxbox
Table of Contents
OXBOX JMM4A0A18S21SA Wall Mount Air Handlers Ton Cooling Heat Pump
Product Information
- Model: JMM4A-SUB-1A
- Product Dimensions (inch):
- Height: 36-1/2 (928)
- Width: 20-1/2 (522)
- Width (W1): 17-2/5 (442)
- Depth: 15 (381)
- Depth (D1): 9-1/2 (242)
- Unit Weight/Shipping Weight (lbs/kg): 88/97 (40/44)
- Rated Volts/Ph/Hz: 208-230/1/60
- Indoor Coil Type: Plate Fin
- Indoor Fan Type: Centrifugal
- Filter Furnished: No
- Type Recommended: Throwaway
- Refrigerant: R-410A
- External Static Pressure (inwc.):
- Speeds:
- Low: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8
- Medium: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8
- High: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8
Product Usage Instructions
- Ensure that the unit is installed with the minimum clearance specified in the user manual.
- Connect the gas line with a 3/4-inch braze coupling.
- Connect the refrigerant line with a 3/4-inch gas coupling and a 3/8-inch liquid coupling.
- Install the recommended throwaway filter with dimensions 16x20x1 inch.
- Power the unit with the rated volts/ph/hz of 208-230/1/60.
- Adjust the external static pressure settings based on the desired airflow performance.
Dimensional and Clearance Data
MINIMUM UNIT CLEARANCE TABLE
| TO COMBUSTIBLE MATERIAL (REQUIRED)| SERVICE
CLEARANCE (RECOMMENDED)
SIDES| 0″| 0″
FRONT| 0″| 24″
BACK| 0″| 0″
INLET DUCT| 0″| 0″
OUTLET DUCT| 0″*|
- 0″ FOR THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTALLED
PRODUCT DIMENSIONS
PRODUCT DIMENSIONS inch (mm) | Unit weight/ Shipping Weight [LBS(kg)] |
---|---|
Height | |
H | W |
JMM4A0A18S21SA | 36-1/2″ (928) |
(242) | Orifice |
JMM4A0A24S21SA | 36-1/2″ (928) |
(242) | Orifice |
JMM4A0B30S21SA | 39-1/2″ (1004) |
(242) | Orifice |
JMM4A0B36S31SA | 39-1/2″ (1004) |
(242) | Orifice |
PRODUCT SPECIFICATIONS
Refrigerant Control | Orifice | Orifice | Orifice | Orifice |
---|---|---|---|---|
Drain Conn Size (in.) | 3/4 NPT | 3/4 NPT | 3/4 NPT | 3/4 NPT |
DUCT CONNECTIONS | See Outline Drawing | See Outline Dawing | See Outline | |
Drawing | See Outline Drawing | |||
INDOOR FAN — Type | Centrifugal | Centrifugal | Centrifugal | Centrifugal |
Diameter-Width (In.) | 10-5/6 X 6-1/7 | 10-5/6 X 6-1/7 | 10-3/5 X 9-10/7 | 10-3/5 |
X 9-10/7
No. Used
Drive – No Speeds CFM vs. in. w.g.
| 1
Direct – 3
See Fan
| 1
Direct – 3
See Fan
| 1
Direct – 3
See Fan
| 1
Direct – 3
See Fan
| Performance Table| Performance Table| Performance Table| Performance Table
No. Motors — H.P.| 1 – 1/6| 1 – 1/4| 1 – 1/3| 1 – 1/2
Motor Speed R.P.M.| 1075| 1075| 1075| 1075
Volts/Ph/Hz| 208-230/1/60| 208-230/1/60| 208-230/1/60| 208-230/1/60
F.L. Amps| 0.8| 1.0| 1.28| 1.8
FILTER
Filter Furnished?
|
No
| No|
No
|
No
Type Recommended| Throwaway| Throwaway| Throwaway| Throwaway
No.-Size-Thickness| 1 – 16X 20 – 1 in.| 1 – 16X 20 – 1 in.| 1 – 20X 20 – 1
in.| 1 – 20X 20 – 1 in.
REFRIGERANT
Ref. Line Connections Coupling or Conn . Size — in.
| R-410A
Brazed
Gas 3/4
| R-410A
Brazed 3/4
| R-410A
Brazed 3/4
| R-410A
Brazed 3/4
Coupling or Conn . Size — in.| Liq. 3/8| 3/8| 3/8| 3/8
DIMENSIONS| H x W x D| H x W x D| H x W x D| H x W x D
Cr ated (In.)| 39-3/8×22-6/7×17-1/3| 39-3/8×22-6/7×17-1/3|
42-4/7×24-1/4×21-2/7| 42-4/7×24-1/4×21-2/7
Uncrated| 36-1/2×20-1/2×15| 36-1/2×20-1/2×15| 39-1/2×22×19| 39-1/2×22×19
WEIGHT| | | |
Shipping (Lbs.)/ Net (Lbs.)| 97/88| 97/88| 119/106| 119/106
Performance and Electrical Data
Performance and Electrical Data – JMM4A0A18–B36
AIR FLOW PERFORMANCE (Standard CFM)
Model Number | Motor Speeds | EXTERNAL STATIC PRESSURE (INWC.) | |
---|---|---|---|
0 | 0.1 | 0.2 | 0.3 |
JMM4A0A18S21SAA
| ****
Low
| CFM| 603| 562| 525| 485| 443| 393| —| —| —
Watts| 216| 212| 208| 202| 197| 190| —| —| —
Amps| 1.1| 1.1| 1.1| 1| 1| 1| –| –| –
Medium
| CFM| 695| 656| 620| 581| 540| 498| 440| 380| —
Watts| 227| 224| 220| 216| 210| 203| 196| 188| —
Amps| 1.2| 1.1| 1.1| 1.1| 1.1| 1| 1| 1| –
High
| CFM| 813| 775| 731| 692| 653| 609| 560| 501| 424
Watts| 284| 279| 273| 267| 261| 253| 245| 237| 227
Amps| 1.5| 1.4| 1.4| 1.4| 1.3| 1.3| 1.3| 1.2| 1.2
JMM4A0A24S21SAA
| ****
Low
| CFM| 676| 640| 602| 563| 523| 499| –| –| –
Watts| 238| 232| 226| 222| 217| 214| —| —| —
Amps| 1.2| 1.2| 1.2| 1.1| 1.1| 1.1| –| –| –
Medium
| CFM| 845| 801| 759| 716| 675| 626| 573| 510| –
Watts| 276| 271| 266| 261| 256| 252| 247| 242| —
Amps| 1.4| 1.4| 1.4| 1.3| 1.3| 1.3| 1.3| 1.2| –
High
| CFM| 947| 895| 847| 799| 753| 704| 655| 592| 530
Watts| 343| 336| 329| 322| 315| 309| 303| 297| 291
Amps| 1.8| 1.7| 1.7| 1.6| 1.6| 1.6| 1.5| 1.5| 1.5
JMM4A0B30S21SAA
| ****
Low
| CFM| 992| 952| 912| 873| 828| 782| 728| 656| 627
Watts| 327| 318| 308| 299| 290| 281| 273| 264| 256
Amps| 1.7| 1.6| 1.6| 1.5| 1.5| 1.4| 1.4| 1.4| 1.3
Medium
| CFM| 1211| 1165| 1114| 1065| 1016| 960| 899| 833| 748
Watts| 359| 353| 346| 338| 330| 321| 311| 300| 289
Amps| 1.8| 1.8| 1.8| 1.7| 1.7| 1.6| 1.6| 1.5| 1.5
High
| CFM| 1367| 1312| 1252| 1192| 1131| 1063| 990| 908| 821
Watts| 450| 440| 430| 420| 409| 397| 384| 371| 358
Amps| 2.3| 2.3| 2.2| 2.1| 2.1| 2| 2| 1.9| 1.8
JMM4A0B36S31SAA
| ****
Low
| CFM| 1149| 1105| 1056| 1008| 960| 909| 856| 791| 726
Watts| 392| 380| 368| 356| 344| 332| 321| 309| 297
Amps| 2| 1.9| 1.9| 1.8| 1.8| 1.7| 1.6| 1.6| 1.5
Medium
| CFM| 1298| 1252| 1198| 1147| 1094| 1037| 976| 910| 842
Watts| 400| 390| 380| 370| 360| 350| 340| 329| 319
Amps| 2| 2| 1.9| 1.9| 1.8| 1.8| 1.7| 1.7| 1.6
High
| CFM| 1397| 1345| 1290| 1263| 1196| 1116| 1051| 980| 907
Watts| 460| 452| 443| 433| 422| 410| 396| 382| 366
Amps| 2.4| 2.3| 2.3| 2.2| 2.2| 2.1| 2| 2| 1.9
Shaded boxes represent airflow outside the required 300-450 cfm/ton.
NOTES:
- Airflow based upon dry coil at 230V with no electric heat, no filter.
- Airflow is equivalent for front or bottom return configurations.
- SCFM is nearly the same with cooling performance airflow, the gap is in the 1 to 2%.
JMM4A0A18S21SA – ELECTRICAL DATA
JMM4A0A18S21SA – ELECTRICAL DATA
Heater Model No
| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per
Circuit
| Minimum
Circuit Ampacity
| Maximum Overload
Protection
| Capacity| Heater Amps per
Circuit
| Minimum
Circuit Ampacity
| Maximum Overload
Protection
kW| BTUH| kW| BTUH
No Heater| | | | | 1.0| 15| | | | 1.0| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 27.1| 30| 3.8| 12800| 18.0| 23.6| 25
BAYHTRJ508BRKA| 1/1| 7.5| 25600| 31.2| 40.1| 45| 5.6| 19200| 27.1| 34.9| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 53.1| 60| 7.5| 25600| 36.1| 46.2| 50
JMM4A0A24S21SA – ELECTRICAL DATA
JMM4A0A24S21SA – ELECTRICAL DATA
Heater Model No
| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater
Amps per Circuit
| Minimum
Circuit Ampacity
| Maximum
Overload Protection
| Capacity| Heater
Amps per Circuit
| Minimum
Circuit Ampacity
| Maximum
Overload Protection
kW| BTUH| kW| BTUH
No Heater| | | | | 1.3| 15| | | | 1.3| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 27.3| 30| 3.8| 12800| 18.0| 23.9| 25
BAYHTRJ508BRKA| 1/1| 7.5| 25600| 31.2| 40.4| 45| 5.6| 19200| 27.1| 35.2| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 53.4| 60| 7.5| 25600| 36.1| 46.4| 50
JMM4A0B30S21SA – ELECTRICAL DATA
JMM4A0B30S21SA – ELECTRICAL DATA
Heater Model No
| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per
Circuit
| Minimum
Circuit Ampacity
| Maximum Overload
Protection
| Capacity| Heater Amps per
Circuit
| Minimum
Circuit Ampacity
| Maximum Overload
Protection
kW| BTUH| kW| BTUH
No Heater| | | | | 1.6| 15| | | | 1.6| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 27.7| 30| 3.8| 12800| 18.0| 24.2| 25
BAYHTRJ508BRKA| 1/1| 7.5| 25600| 31.2| 40.7| 45| 5.6| 19200| 27.1| 35.5| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 53.7| 60| 7.5| 25600| 36.1| 46.8| 50
JMM4A0B36S31SA – ELECTRICAL DATA
JMM4A0B36S31SA – ELECTRICAL DATA
Heater Model No
| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per
Circuit
| Minimum
Circuit Ampacity
| Maximum
Overload Protection
| Capacity| Heater Amps per
Circuit
| Minimum
Circuit Ampacity
| Maximum
Overload Protection
kW| BTUH| kW| BTUH
No Heater| | | | | 2.3| 15| | | | 2.3| 15
BAYHTRJ505BRKA| 1/1| 5| 17100| 20.8| 28.3| 30| 3.8| 12800| 18.0| 24.9| 25
BAYHTRJ508BRKA| 1/1| 7.5| 25600| 31.2| 41.4| 45| 5.6| 19200| 27.1| 36.2| 40
BAYHTRJ510BRKA*| 1/1| 10| 34100| 41.7| 54.4| 60| 7.5| 25600| 36.1| 47.4| 50
Mechanical Specifications
STANDARD FEATURES
- Front or bottom return air
- Painted finish on galvanized steel
- Sturdy polycarbonate drain pans
- The JMM4 wall mount air handler a has factory-installed drain pan and is shipped for upflow applications only.
- 208/230 – VAC operation
- Multi-speed direct drive blower
- PSC motor
- • Stud or wall mounting tabs
- Fully insulated cabinet
- 3/4″ NPT primary and secondary drains
- All – aluminum tubes & fins
OPTIONAL ACCESSORIES
- 5, 7.5, and 10 kW single phase electric heaters
- Circuit breakers are standard on all single phase 5, 7.5, and 10 kW heaters.
- R-410 TXV kit – 4AYTXVH3G2436
- R-22 TXV conversion kit – 2AYTXVH3G2436
- Front louver panel 20.5″ width – BAYFRTLOUPNL20 (1-Pack)
- Front louver panel 22″ width – BAYFRTLOUPNL22 (1-Pack)
- Return air / service wall panel – BAYTMMWALLPNL1 (20-Pack)
- Return air / service wall panel – BAYTMMWALLPNLS (1-Pack)
The Manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.